Tender For Work Of Painting Of Various Equipments , Boxes Structures , Pale Fencing And Other Associated Works At 132 Kv S/S Kauriram And 132 Kv S/S Maharajganj Under Etd-Ii, Gorakhpur
Tender Value
4.38 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
11 days left
EMD
4400
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gorakhpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Work Of Painting Of Various Equipments , Boxes Structures , Pale Fencing And Other Associated Works At 132 Kv S/S Kauriram And 132 Kv S/S Maharajganj Under Etd-Ii, Gorakhpur
BOQ
| Sl. No. | Item Description |
| 1 | Scraching of old and rusted painted surface of cubicles and applying putty on holds then providing red oxide primer of luxol burger make in 02 coats. Applying spray painting of smoke grey colour enamel paint in 02 coats after 12 hour interval of Berger , Nerolac Asian make along with brush painting of inner surface by white grey colour and then writing of nomenclature details on 220/132/33 isolator MOM boxes 220/132/33 kV CT, PT ,CVT junction boxes , 220/132/33 KV Circuit Breakers Marshalling boxes , A.C. supply Cubicle boxes using radium sheet with all cost of men , material T&P etc. required to complete the job as per details given bellow. |
| 2 | 132 KV S/S MAHRAJGANJ |
| 3 | 132 KV Circuit Breaker Mechanism Boxes |
| 4 | A.C. Power Supply Cubicles of size 1300×800×400 mm |
| 5 | A.C. Power Supply Cubicles of size 1100×900×300 mm |
| 6 | 132KV Current Transformers. |
| 7 | 132KV C.T. Junction Boxes |
| 8 | 132KV P.T. Junction Boxes |
| 9 | 132KV Isolator MOM Boxes (LSI/BSI/Tandem) |
| 10 | 33 KV Current Transformers |
| 11 | 33 KV CT junction boxes |
| 12 | 33 KV Potential Transformers |
| 13 | 33 KV PT Junction boxes |
| 14 | 33 KV Isolator MOM boxes (Drive box LSI, BSI, Tandem) |
| 15 | Writing of nomenclature details on various control and relay panels, ACDB, ACLDB Panels, Battery charger panels, mulsifire system Panels, DG Set panel, CTR Panel, RTCC Panel and RTU Panel installed at 132KV S/S Mahrajganj control room in white colour synthetic enamel paint with all cost of men, materials and T&P for the work as per direction of UPPTCL Supervisor/Engineer. |
| 16 | Writing of nomenclature details on various Ways/ Lines of, 132 kV and 33kV, Marshalling boxes , 40MVA ad 63 MVA , STN T/F and Capacitor bank installed at 132 kV substation Mahrajganj in white colour synthetic enamel paint with all cost of men, materials and T&P for the work as per direction of UPPTCL Supervisor/ Engineer. |
| 17 | Spray painting of substation transformer |
| 18 | Sparay Painting of Cage / Net Fencing of Capacitor Bank |
| 19 | Spray painting of following with one coat of red oxide primer and two coats of standard make light grey/bus green synthetic enamel paint 608-4 of first quality after cleaning of rust ,dust and oily surface including cost of all material , labour and T&P as per technical specification. |
| 20 | Earthing strip 75X10 mm size |
| 21 | Earthing strip 50X6 mm size |
| 22 | Earthing strip 25X6 mm size |
| 23 | Painting of Pale Fencing |
| 24 | Repairing and Fixing of pale fencing by providing new nuts and bolts wherever required and welding of upright and runner, damaged/ broken/rusted pales as per actual needs including all cost of materials, labour T&P at 132KV S/S Mahrajganj |
| 25 | 132 KV S/S KAURIRAM |
| 26 | 132 KV Circuit Breaker Mechanism Boxes |
| 27 | A.C. Power Supply Cubicles of size 1300×800×400 mm |
| 28 | A.C. Power Supply Cubicles of size 1100×900×300 mm |
| 29 | 132KV Current Transformers. |
| 30 | 132KV Potential Transformers. |
| 31 | 132KV C.T. Junction Boxes |
| 32 | 132KV P.T. Junction Boxes |
| 33 | 132KV Isolator MOM Boxes (LSI/BSI/Tandem) |
| 34 | 33 KV Current Transformers |
| 35 | 33 KV CT junction boxes |
| 36 | 33 KV Potential Transformers |
| 37 | 33 KV PT Junction boxes |
| 38 | 33 KV Isolator MOM boxes(LSI, BSI, Tandem) |
| 39 | Writing of nomenclature details on various control and relay panels, ACDB, ACLDB Panels, Battery charger panels, mulsifire system Panels, DG Set panel, CTR Panel, RTCC Panel and RTU Panel installed at 132KV S/S Kauriram control room in white colour synthetic enamel paint with all cost of men, materials and T&P for the work as per direction of UPPTCL Supervisor/Engineer. |
| 40 | Writing of nomenclature details on various Ways/ Lines of, 132 kV and 33kV, Marshalling boxes , 40MVA ad 63 MVA , STN T/F and Capacitor bank installed at 132 kV substation Kauriram Gorakhpur in white colour synthetic enamel paint with all cost of men, materials and T&P for the work as per direction of UPPTCL Supervisor/ Engineer. |
| 41 | Spray Painting of Cage / Net Fencing of Capacitor Bank |
| 42 | Spray painting of following with one coat of red oxide primer and two coats of standard make light grey/bus green synthetic enamel paint 608-4 of first quality after cleaning of rust ,dust and oily surface including cost of all material , labour and T&P as per technical specification. |
| 43 | Earthing strip 75X10 mm size |
| 44 | Earthing strip 50X6 mm size |
| 45 | Earthing strip 25X6 mm size |
| 46 | Painting of Pale Fencing |
| 47 | Repairing and Fixing of pale fencing by providing new nuts and bolts wherever required and welding of upright and runner, damaged/ broken/rusted pales as per actual needs including all cost of materials, labour T&P at 132KV S/S Kauriram Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender