Tender For Dd - T.T.C. & Kalwa...M&R To Fire Station In Ttc Indl. Area Annual Maintenance Of Electrical Installation At Fire Stations In R & D-Block In Ttc Indl. Area For One Year.
Tender Value
23.32 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
6 days left
EMD
23400
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Dd - T.T.C. & Kalwa...M&R To Fire Station In Ttc Indl. Area Annual Maintenance Of Electrical Installation At Fire Stations In R & D-Block In Ttc Indl. Area For One Year.
BOQ
| Sl. No. | Item Description |
| 1 | Sub Estimate |
| 2 | Providing 1 licensed electrician & 1 helper for all days in a month for day to day requirement & Maintenance of electrification provided at R&D Block fire station Complex including fencing lighting , alteration in existing wiring operation complete with all necessary tools as per direction of engineer-in-charge, Maintenance of entire L.T. electrical installation including , parking lights etc including providing licensed electrician wireman & labour for day to day checking , identifying & rectifying the faults in the L.T. electrical system including replacing of burnt accessories such as fixtures, cable, wire, pipes, brackets, feeder pillars, Tube, Fans etc & direction by Engineer-in-charge ( Material such as Tube, Fans, Fittings, MCB , Box, wire, cable etc will be supplied by MIDC ) |
| 3 | Indoor LED Fittings (FG-IDF/LED) |
| 4 | Supplying LED square / circular Max. 18 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 5 | Supplying LED square / circular Max. 25 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 6 | Supplying LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 7 | Accessories for Indoor Fittings (FG-AS) |
| 8 | Supplying ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block / sunmica block of suitable size. |
| 9 | Supplying electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. |
| 10 | Highbay LED Fittings (FG-ODF/LED) |
| 11 | Supplying integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/LED. |
| 12 | Accessories for Outdoor Fittings (FG-BKT) |
| 13 | Supplying Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC. |
| 14 | Lamps and Tubes for Indoor & Outdoor (FG-LP) |
| 15 | Supplying ready to use Retrofit T8 LED, 18 / 20 watt tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary as per specification No. FG-LP/RET. |
| 16 | Fans (FG-FN) |
| 17 | Supplying regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF. |
| 18 | Providing air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. |
| 19 | Supplying cabin fan of A.C. 230 V. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. |
| 20 | Supplying exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF |
| 21 | Accessories for Fans (FG-FAS) |
| 22 | Supplying condenser 2.5 micro farad for ceiling fan |
| 23 | Supplying electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 24 | Bunch of Wires (WG-MA/BW) |
| 25 | Supplying mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW |
| 26 | Mains on GI Bare Wire (WG-MA/GB) |
| 27 | Supplying mains with WP 3 x 6 sq. mm. 1.1kV. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. |
| 28 | Modular switches and Accessories |
| 29 | Supplying modular type switch 6A/10A on provided plate and box with wiring connections complete. |
| 30 | Supplying modular type switch 16A on provided plate and box with wiring connections complete. |
| 31 | Supplying modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 32 | Supplying PVC Surface modular switch box with double mounting plate for 3 module complete. |
| 33 | Supplying PVC Surface modular switch box with double mounting plate for 6 module complete. |
| 34 | Supplying PVC Surface modular switch box with double mounting plate for 12 module complete. |
| 35 | LT - MCBs/ MCB Change Over Switch (SW-MCB) |
| 36 | Supplying & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 37 | Supplying & marking SP MCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 38 | Supplying & marking DP MCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 39 | Supplying & marking TP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 40 | Measuring Instruments (CP-MI) |
| 41 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 42 | Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 43 | Accessories |
| 44 | Supplying selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs. |
| 45 | Supplying, erecting, testing & commisioning 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee. |
| 46 | Supplying LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 47 | Rewinding |
| 48 | Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types and makes and overhauling including minor repairs lubricating of ball bearings & bush bearing, replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year. |
| 49 | Rewinding of electric motor above 3 HP upto 5 HP three phase upto 1400 RPM of all types and makes with copper wire confirming to IS 13730 : 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 50 | Rewinding of submersible pump motor in borewell of all types and makes above 5 HP up to 25 HP with coated copper wire conforming to IS 13730: 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed, H.P. and no load consumption & guarantee for one year. |
| 51 | Replacement |
| 52 | Replacing the existing driving end bearing of original make for electric motor AC single phase / three phase 3 HP to 7.5 HP of all types with required alignment of the shaft and testing the same.. |
| 53 | Replacing the existing driving end bearing of original make for electric motor AC single phase / three phase 10 HP of all types with required alignment of the shaft and testing the same. |
| 54 | Replacing the existing non driving end bearing of original make for electric motor AC single phase / three phase 3 HP to 7.5 HP of all types with required alignment of the shaft and testing the same. |
| 55 | Replacing the existing non driving end bearing of original make for electric motor AC single phase / three phase 10 HP of all types with required alignment of the shaft and testing the same |
| 56 | LT- Air -Circuit Breaker |
| 57 | Providing maintenance of ACB of all range with ACB maintenance kit by ACB manufacturer consisting of all these essential consumable like greases, cleaning spray, dusters, scrubbers and hardware required and carrying out necessary corrective maintenance of ACB complete. |
| 58 | Providing fully comprehensive annual maintenance service for 80/120/150 ltr. water cooler unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares including minor electrical parts within 48 hours. 4) refrigerant charging if required. 5) if failed to rectify the fault within 48 hrs penalty shall be charged Rs.50/- per day.The job exclude sheet metal work and plastic material. |
| 59 | Supply of Spares for LT ACB |
| 60 | Supply of Terminal adaptor for Draw out type OMEGA, L&T ACB, 400A-2000A N/S/IH, (Vertical / Horizontal). |
| 61 | Supply of closing release coil (CR) 220-240V AC /220-250V DC for Draw out type OMEGA,L&T ACB, 400A-2000A |
| 62 | Supply of Shunt release coil (SR) 220-240V AC/ 220- 250V DC for Draw out type OMEGA,L&T ACB, 400A- 2000A. |
| 63 | \\"Supply of under voltage coil for 400/800/1600 Amp ACB.\\" |
| 64 | Supply of Jaw contact for 400/800/1600 Amp ACB |
| 65 | Supply of spring set for Omega L &T ACB 400 Amp to 2000 Amp. |
| 66 | Accessories for AC & Water cooler |
| 67 | Providing annual comprehensive maintenance contract for 2 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. |
| 68 | Comprehensive maintenance of street lights, providing licensed electrician, wireman and labor for day to day checking, identifying, reporting and rectifying the faults in the street light system, including replacing of burnt accessories of poles, cable, wires, pipes, brackets, feeder pillars and directed by Engineer-in-charge. The rate of the item includes cost of all labors and spares such as, wires, pipes, trench, cables, FP etc complete during the maintenance period (Rate excluding GST). |
| 69 | Submersible pumps for Openwells (WP-OSP) |
| 70 | Supplying, erecting, testing and commissioning of minimum three & above star rated 3 phase, 415 V, 50 Hz, submersible pump set of 7.5 kW/10HP suitable for erection on open well, pump having delivery head from 60 to 28 m and discharge from 120 to 840 litres per minute & 65 mm suction/50 mm delivery dia. as per specification no. WP-OSP. |
| 71 | Dismantling |
| 72 | Dismantling the existing submersible pump with GI pipeline upto 10 m depth. (For additional depth of each 3 m or part thereof add Rs. 50/- per 3 m, in the rates) |
| 73 | Supplying and fixing M.S. Pipe 80 mm diameter ( 4.85 mm thick ) heavy type drilled on top and painted with one coat of epoxy primer and two coats of epoxy finish paint having black and white bands of 25 cm, last part of the post 0.75 mt. below ground level is painted with three coats of red lead paint with two Nos. of high tensile G.I. bolt and nut of size 10 mm die of 25 mm long including transportation etc. complete. |
| 74 | Valves (FF-VL) |
| 75 | Sluice Valve |
| 76 | Supplying and erecting 75/80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 77 | Non Return Valve ( NRV ) |
| 78 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 79 | Supply, installation, testing & commissioning of LT Starter Panel complete with 125A, 3P+N, 25kA TMD based MCCB incomer with rotary handle and spreader link set, aluminium bus bars (Ph/N/E – 1x25x6mm), digital voltmeter & ammeter with 125/5A Class-1 CTs, RYB indication lamps with terminal fuse, and outgoing feeders comprising for 6 nos of outgoing 7.5 to 10HP DOL starters each complete with 32A 3P 10kA MCB, 32A 3P power contactor, 10–16A bimetal overload relay, ON/OFF/TRIP indication lamps, START/STOP push buttons, 6A control MCB with neutral link set, power & control terminals, internal wiring, earthing, labels, MPP type 4 KVAR Capacitor bank and all accessories required for satisfactory operation, complete and spare parts shall have approved make & Panel Size- L-1100 x H-1200 x D-300mm with powder coted RAL-7035 for R-block fire station. |
| 80 | Supply, installation, testing & commissioning of LT Starter Panel complete with 125A, 3P+N, 25kA TMD based MCCB incomer with rotary handle and spreader link set, aluminium bus bars (Ph/N/E – 1x25x6mm), digital voltmeter & ammeter with 125/5A Class-1 CTs, RYB indication lamps with terminal fuse, and outgoing feeders comprising for 4 nos of outgoing 7.5 to 10HP DOL starters each complete with 32A 3P 10kA MCB, 32A 3P power contactor, 10–16A bimetal overload relay, ON/OFF/TRIP indication lamps, START/STOP push buttons, 6A control MCB with neutral link set, power & control terminals, internal wiring, earthing, labels, MPP type 4 KVAR Capacitor bank and all accessories required for satisfactory operation, complete and spare parts shall have approved make & Panel Size- L-1100 x H-1200 x D-300mm with powder coted RAL-7035 for D-block fire station |
| 81 | Accessories |
| 82 | Supplying, erecting, testing and commissioning of flat flexible 3 core 16 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 83 | LT Cables (Aluminum) (CB-LT/AL) |
| 84 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 85 | Cable Enclosures (CB-CE) |
| 86 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 87 | Plate, Pipe type Earthing (EA-EP) |
| 88 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 89 | Credit for Dismantled Material |
| 90 | Ceiling/cabin/bracket/pedestal/table fan. |
| 91 | Exhaust Fan 12\\" Sweep |
| 92 | Accessories such as tube starter / bell / holder / ceiling rose / MCB / MCCB / Contactor / PT etc. |
| 93 | Water pump sets. |
| 94 | All types of LED Tube and Fixtures Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender