Power Government Departments Closing in 17 days TDR #56323552

Tender For Installation Of Additional 4 Mva Power Transformer Laying At Site At 33/11 Kv 1X6.3 Mva Receiving Station, Mahanpur (Billawar)

Issued by Government Departments · Kathua, Jammu and Kashmir
Tender Value
65 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
17 days left
EMD
1.30 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kathua → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Installation Of Additional 4 Mva Power Transformer Laying At Site At 33/11 Kv 1X6.3 Mva Receiving Station, Mahanpur (Billawar)

BOQ

Name of Work:- Installation of Additional 4 MVA Power Transformer laying at site at 33/11 KV 1x6.3 MVA Receiving Station, Mahanpur (Billawar)
Sl. No. Item Description
1Installation of Additional 4 MVA Power Transformer laying at site at 33/11 KV 1x6.3 MVA Receiving Station, Mahanpur (Billawar)
2SITC of 36kV,1250A,26.2KA,3phase Outdoor Type Vaccum Circuit Breaker alonwith supportstructure, marshalling box and required accessories complete and connection with existing CR panel after laying of various control cables.
3SITC of 33kV,1250Amp,25kA,double break centre rotating type DBCR)without Earthing Blade,G.O Isolator along with support insulators,operatingmechanism ,base channel down pipe & all required accessories complete (3 no.s)
4SITC of 33 kV CurrentTransformer(33kV Multi Ratio, Multi Core Single Phase(1No. Per Phase) Outdoor & all required accessories complete CT ratio 200/100/5-5A (3 no.s)
5SITC of Gapless Surge arrestor ,33kV,10kA,Lightening Arrestors LA with Polymer housing & all required accessories complete class-2 confirming to IEC- 60099-4 withsurge counter (3 no.s)
6SITC of 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annuciation Wingows withAnnunciation relays, 3-Phase Tri-Vector meter-5Amps, DLMS Compliant with RS-485 port
7SITC of 33 kV Voltage Transformer (33 kV/110 V, Single Phase, Multi Core Outdoor) & all required accessories complete 0.2S class (3 no.s
8SITC of 33KV Post insulator Polymer, 36 KV,235 KV Impulse, creepage distance 1224mm as per TS
9Nominal Bore 200, 5.9mm thick
10Providing and erection Galvanized Steel Structure asper approved drawing
11Galvanized Nuts & Bolts
12Supplying, Laying and connection of 12 Core2.5mm ²Control cable copper Armoured,1.1kV Grade,ISI,FRLS.
13Supplying, Laying and connection of 6 Core 2.5mm²Control cable copper Armoured,1.1kV Grade,ISI,FRLS.
14Supplying, Laying and connection of 2Core2.5mm²Control cable copper Armoured,1.1kVGrade,ISI,FRLS.
15Lugs., ferrule etc
16Supplying, Laying and connection of 200 mm square ACSR Panther conductor as bus bar in transformer bay.
17sitc of T clamps/Pad Clamps
18Installation, Testing and Commissioning of 4 MVA 33/11KV Power Transformer laying at site
19Supplying, Laying and connection of 12 Core2.5mm ²Control cable copper Armoured,1.1kV Grade,ISI,FRLS.
20Supplying, Laying and connection of 6 Core 2.5mm²Control cable copper Armoured,1.1kV Grade,ISI,FRLS.
21Supplying, Laying and connection of 2Core2.5mm²Control cable copper Armoured,1.1kVGrade,ISI,FRLS.
22SITC of 11kv VCB panel Board (12kv.1250A,25KA, Indoor) with O/C, E/F relays SCADA Compatible (IEC61850), Mimic Diagram, voltmeter, ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector-5Amps, DLMS. Compliant with RS-485 port. The relay should have sensitive ground fault pickup feature. CT ratio -750/375/5-5A, outgoing VCB 400-200/5-5A. The dimension of the VCB incomer should be compatible with the size of existing panel set at sub station .(1+2 Panels)
23SITC of 11kv, Gapless Surge Arrestor,9 KV ,10 KA, LA with Polymer housing, Stn. Type (4 Sets)
24SITC of 11kv XPLE Power Cables-
2511 kV 3- Core XLPE 185 mm² armored, FRLS
26SITC of 11 kV Heat Shrinkable Cable Termination Kit for incoming Cable
2711 kV Indoor Heat Shrinkable Cable Termination Kits
2811 kV Outdoor Heat Shrinkable Cable Termination Kits
29SITC of 11 kV Heat Shrinkable Cable Termination Kit for Outgoing Cable
3011 kV Indoor Heat Shrinkable Cable Termination Kits
3111 kV Outdoor Heat Shrinkable Cable Termination Kits
32SITC of 11 kV Isolator, double break,3-pole, 600Amp, horizontal mounting Type, with Earth Switch.
33SITC of 9 Mtr. Long Pole (ST-410 SP33)
34SITC of Galvanized iron of sorts
35SITC of 120 mm² PVC LT Cable 4 Core, armored, FRLS
36Supply and Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole
37SITC and Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip
38sitc of MCCB - 200 Amps
3933/11 kV Power Transformer Foundation RCC M-20 (1:1.5:3)
4033 kV Equipment Foundation & Gantry foundation RCC M-20 (1:1.5:3)
41Laying of Earthing Mat GI Flat 50mmx8mm as per approved drawings
42Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip/flats 50mmx6mm.
4333 kV Yard Concreting/Metalling
44Borewell with submersible pump
45Yard Lightening
46Rubber Mat 1mx2m 19mm thick Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56323552
AUTHORITY Government Departments
TENDER VALUE 65 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Power Development Department
Work Description Tender for Installation Of Additional 4 Mva Power Transformer Laying At Site At 33/11 Kv 1X6.3 Mva Receiving Station, Mahanpur (Billawar)
Basic Detail
Tender No STD-III/e-NIT/2026-27/6 Dated 04.07.2026
Bidding Type Tender
Location
City Kathua
State Jammu and Kashmir
Key Dates
Publish Date 06 Jul 2026
Submission Date 30 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 65 Lakhs
Tender Fee 3000
EMD 1.30 Lakhs
Exemption Not Available
Document List
3b5fa655-268a-4379-aca1-11de7c68b9d0.html
BOQ_1019298.xls
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.