| Sl. No. | Item Description |
| 1 | OD1718/2026-2027: Supply, erection, testing, and commissioning of V3F passenger cum freight lift 13 Person capacity (884 KG) suitable for installing 1900 X 2500 mm as per the Actual size of the lift well at the site and the following requirements.Number of Openings from cellar + Ground to four floors (C+G+1+2+3+4) Full Height Infrared Light curtain in the car door safety in full length. Door open and door close Buttons. Separate fan switch with timer cut off in the car. Indication of car and Landing call registration, Position indicator in the car, and all landings. Variable speed Door opening and closing time. Inverter-based Emergency alarm bell. Stainless Steel Cabin hairline finishing with half-portion glass Height toughened viewing glass suitable thickness of both car and Landing door with frame work etc., and also provide the facilities to fix advertisements on the two sides of the lift wall Signal Fixtures. Emergency LED Lights supported with an inverter. Call registering micro push button. intercom system, Door Pressure Limit Switch (Enhanced Door Safety). Serial communication-based LCE Controller. Special features Battery-operated rescue device for power failure Braille buttons for car and landing Lift Floor Announcement system Intercom. Speed 1.00 Meter/Second Type of Drive Variable Voltage Variable Frequency (VVVF) Imported. Location of Machine Room Above the Lift Well. Machine Motor Unit Three Phase, Induction Motor, 415V Location of Machine Room Above the Lift Well. Overload protection. Granite Flooring, SS handrail, etc., complete as per EI & KSEB rules. Necessary lift Approval and License shall be obtained from the EI as per the Contractor's scope; the Elevator shall be designed in line with the recommendation continued in the latest edition of applicable Indian Standards. The design / Construction /Installation codes shall confirm the latest edition of IS:14665(All parts) and also meet any additional requirements of IS: 4666, IS : 1860 and I S : 3534 and any other equivalent code |
| 2 | OD83067/2026-2027:Providing Comprehensive Annual Maintenance Contract (CAMC) for Passenger Lift for a period of 5 years after the Defect Liability Period (DLP), including monthly preventive maintenance, routine servicing, unlimited breakdown maintenance, testing, adjustment, and replacement of all consumables, spare parts, electrical, electronic, and mechanical components (including Drive, ARD, COP, LOP, control panel components, cabin lights, fans, alarm buzzer, door mechanisms, travelling cables, machine parts, ropes, guide shoes, and all other accessories) required for the safe and satisfactory operation of the lift. The rate shall include all labour, materials, tools, transportation, consumables, testing, and incidental charges complete. Statutory inspection fees, licence renewal fees, and insurance charges payable to Government/Statutory Authorities shall be borne by the Department. |
| 3 | ADDITIONAL ELECTRICAL WORK FOR LIFT WELL |
| 4 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 5 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 6 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 7 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 8 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 9 | 2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 10 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 11 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 12 | OD1726/2026-2027:Supply, providing, testing and commissioning of 7W to 9W PWD-approved make LED Bulb |
| 13 | OD1727/2026-2027:Supplying and fixing the following rating, four poles, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100mA in the existing MCB DB complete with connections, testing, and commissioning, etc. as required.100 amps |
| 14 | OD1728/2026-2027:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure Outdoor purpose (IP 66) for independent mounting of Isolator/ RCCB/ RCBO. It is suitable for one number 4 pole Isolator + one number 4 poleRCCB and facility to connect input and output cable Etc complete |
| 15 | OD1729/2026-2027:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure Outdoor purpose (IP 66) for independent mounting of Isolator/ RCCB/ RCBO. It is suitable for one number 2 pole Isolator + one number 2 pole RCCB and facility to connect input and output cable Etc complete Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender