Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56321038

Tender For Special Repair/Replacement Of Street Light Timer And Connected Works, Provn Of Security Lights At Various Loc Of 3 Corps Zonal Wksp And Provn Of 30 Kva Stabilizer Of Bldg No T-10 In ‘M Zone At Rms.

Issued by Statutory Bodies & Commissions/Committees · Wokha, Nagaland
Tender Value
46 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
20 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Wokha → Nagaland
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair/Replacement Of Street Light Timer And Connected Works, Provn Of Security Lights At Various Loc Of 3 Corps Zonal Wksp And Provn Of 30 Kva Stabilizer Of Bldg No T-10 In ‘M Zone At Rms.

BOQ

Name of Work:- SPECIAL REPAIR/REPLACEMENT OF STREET LIGHT TIMER AND CONNECTED WORKS, PROVN OF SECURITY LIGHTS AT VARIOUS LOC OF 3 CORPS ZONAL WKSP AND PROVN OF 30 KVA STABILIZER OF BLDG NO T-10 IN ‘M ZONE AT RMS.
Sl. No. Item Description
1S&F in replacement nature switch smart timer based automatic street light control panel, suitable enough to take three phase load for 12-15Kw, 32 Amps per phase with Hensal enclosure, confirming to IP-66 (Navdeep 66 series Nature switches)complete with timer, contactor, relays and incoming outgoing MCBs complete all as specified and as directed.
2S&F in replacment nature switch smart timer based automatic street light control panel, suitable enough to take single phase load for 5-7kW, 32 Amps per phase with Hensal enclosure, confirming to IP-66 (Navdeep 66 series Nature switches)complete with timer, contactor, relays and incoming outgoing MCBs complete all as specified and directed.
3M&L for Earthing complete with galvanized steel earth plate 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less than 2.70 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI SWG wire 6mm dia size up to test point by means of nuts, bolts, check nuts and washers of GI, with and including excavation and earth work, PCC (1:3:6) type C-1 pit, 20mm bore dia GI pipe medium grade pipe for watering arrangement and 15mm bore dia GI pipe, light grade for protection of earth wire, 50mm thick RCC (1:2:4) type B-1 cover, reinforced with 8mm dia TMT bars @ 15cm C/C both ways and with handle made out of 10mm dia bars, funnel, wire mesh etc. as shown in electrical Plate No. 03 of SSR Part-I connected to earthing test point including taking down old unserviceable material and testing on completion complete all as specified and as directed.Note : The all earthing pits resistance result is must to maintain within site required range.
4M&L for Earth continuity conductor or main earthing lead fixed to wall/pole on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6mm dia galvanised iron or steel wire complete all as specified and directed. .
5Supply, laying and testing XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
6Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and as directed.
7Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and as directed.
8Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and as directed.
9M&L for spread fine river sand in trenches complete all as specified ans as directed. Note: Punned thickness shall be measured and paid.
10M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
11Supply, erection and fixing of 7 meter high Hot Dip Galvanised (HDG) Octagonal pole with top dia 70mm and bottom dia 130 mm with pole shaft thickness of 3 mm, base plate 200mmx200mm x12mm thick, hole dimensions 24X32mm, with single arm bracket 70mm dia of 1500mm long with 4 Nosx 20mm dia foundation bolts 600mm long, Projects Bolt length 100 mm long, EN8 grade of size M20x600mm long J type, with connector block complete all as specified and as directed by Engr-in-Charge.
12S&F in replacement of LED street light fitting 60 Watts, IP 66, having pressure die cast alumnium alloy housing with heat resistant with individual peanut LED lenses and Driver shall be IP-66 for water protection, including surge protection device 5 KV including suitable size of GI bracket, clamps, nuts, bolts, washers etc complete all as per specified and as directed.
13S&F 2 core FRLSH PVC insulated stranded aluminium conductor cable of size 2.5 sq mm, 1100 volts grade ISI marked complete all as specified and directed.
14M & L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete for pole foundation complete all as specified and as directed.
15Supply, installation, testing and commissioning of Servo controlled voltage stabilizer Capacity 30 KVA (Confirming to BIS 9815:Part-I :1994 reaffirmation 2019 latest version) Three phase,four wire (RBYN),50 Hz, Naturally Oil cooled , indoor , unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks two nos , digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- (a) Capacity - 30 KVA. (b) Type - Suitable for unbalanced load and unbalanced input. (c) Input voltage - 360V-480V, input frequency 50 Hz. (d) Output voltage - stabilized at any designed/ desired voltage 415 - ± 1% (e) Rated Frequency - 50Hz. (f) Wave form distortion -Nil (g) Response time - not to exceed 20 milli seconds. (h) Sensitivity - (+/-) 1% (j) Rate of correction - Not less than 6 Volt/ second between phase and Neutral (k) Efficiency - more than 95% (l) Type of load - three phase, unbalanced type (m) Metering- Digital display Voltmeter/ Ammeter with multi - functional meter (n) Operating Temperature - For indoor use upto max ambient temp + 55 C (o) Dimmer rating 20 Amp (p) Dimension of tanks - (43 x 22 x 40) in inches (q) Oil capacity 160 (Ltrs) (r) Class of insulation - Class F
16Item 15.00 Contd...(s) Mode of operation Automatic/ manual (t) Winding Temperature rise - Max 55 degree Celsius(10 degree Celsius above operating temp) (u) Transformer oil - IS 335 marked (v) Core - CRGO M4 Grade / CRNO (Cold Roll Grain Oriented)/ ( Cold Rolled Non Oriented) (w) Auto Transformer (Variac) - 100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z) Protection - (i) Over load protection (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change/ phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g. Marking plate, lifting lugs, CI Rollers, Earthing Terminals etc cable box.
17Supply, laying Rigid non-metallic PVC conduit 32 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56321038
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair/Replacement Of Street Light Timer And Connected Works, Provn Of Security Lights At Various Loc Of 3 Corps Zonal Wksp And Provn Of 30 Kva Stabilizer Of Bldg No T-10 In ‘M Zone At Rms.
Basic Detail
Tender No 9034/C/E8
Bidding Type Tender
Location
City Wokha
State Nagaland
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 46 Lakhs
Tender Fee 500
EMD 92000
Exemption Not Available
Document List
727dc6dd-abee-4282-9a0f-768cf3a2b7f9.html
BOQ_869735.xls
Tender9034.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

727dc6dd-abee-4282-9a0f-768cf3a2b7f9.html

xls

BOQ_869735.xls

pdf

Tender9034.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders