Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56321021

Tender For Repair/ Maintenance To Building Lt Panels, Switch Gears And Cable Tray And Other Connected Items Under Ge (West) Colaba, Mumbai

Issued by Statutory Bodies & Commissions/Committees · Mumbai, Maharashtra
Tender Value
44.95 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
19 days left
EMD
89900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance To Building Lt Panels, Switch Gears And Cable Tray And Other Connected Items Under Ge (West) Colaba, Mumbai

BOQ

Name of Work:- Repair/ Maint to building LT panels, switch gears and cable tray and other connected items under GE (West) Colaba, Mumbai
Sl. No. Item Description
1Material & Labour for repairs/ Overhauling/Servicing to Existing Building LT Panels by taking shut down from appropiate authority including T&P for Attending Faults/Trippings and rectifing /repairing the faults in LT Panels Boards/Capacitor Panels Boaeds/ MCCB's/ Cable Connections/ Bus Bar etc including PVC insulating Tapes/Nut bolts, complete all as specified and directed by Engineer-In-Charge. (i) Tightning the loose connections and cleaning inside/out side complete replacing faulty insulation, thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactor, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting as aproved colour and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed .(Note : MCCB, Painting measured and paid separately under relevant items of this schedule.)
2Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch, 4Pole, 250 Amps, Open Execution (Closed Enclosure),ON LOAD type 415Volts, 50Hz AC including enclosure, complete all as specified and directed by Engineer-In-Charge.
3Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch, 4Pole, 320/400 Amps, Open Execution (Open Enclosure), ON LOAD type 415Volts, 50Hz AC including enclosure. complete all as specified and directed by Engr-in-charge.
4Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4Pole, 320/400 Amps, 35/36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
5Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4Pole, 250 Amps, 35/36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
6Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4 Pole, 200 Amps, 35/36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
7Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 200 Amps, 35/36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
8Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 160 Amps, 36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
9Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 100 Amps, 36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
10Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 100 Amps, 10kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
11Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 63 Amps, 36kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
12Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3Pole, 63 Amps, 10kA, 415Volts, 50Hz AC, complete all as specified and directed by Engr-in-charge.
13Dismantling of old damaged Meters and Supply & fix Digital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt, complete all as specified and directed by Engr-in-charge. Make:AE/MECO/ Elmeasure.
14Dismantling of old damaged Meters Supply & fixing Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, programmable type, complete all as specified and directed by Engr-in-charge. Make:AE/MECO/ Elmeasure.
15M&L Sub main wiring with two runs of 16 sqmm stranded copper conductor PVC unsheathed FRLSH wire along with 16 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 53 mm dia) for housing the wires from panel / Main DB to house SPN DB, complete all as specified & as directed by engr-in-charge.Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 16 sqmm cable and one run of 16 sqmm cable with PVC conduite shall be measured as one length.
16M&L Sub main wiring with two runs of 10 sqmm stranded copper conductor PVC unsheathed FRLSH wire along with 10 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 44 mm dia) for housing the wires from panel / Main DB to house SPN DB, complete all as specified & as directed by engr-in-charge.Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 10 sqmm cable and one run of 10 sqmm cable with PVC conduite shall be measured as one length.
17Supply, lay, fix on wall/pole, 10 Sqmm 3 core copper LT UG cable, 1100 volts grade, PVC insulated, with multistranded Copper conductors, armoured with galvanised steel wire or tape, gland, copper lugs of size 10 Sqmm 3 core, confirming to IS specifications suitable for LT panel including clamp, nut bolt, passing through 20/25mm pipes including cutting of wall / flooring and making good sarface, complete all as specified and directed.
18Supply, lay, fix on wall/pole, 6 Sqmm 3 core copper LT UG cable, 1100 volts grade, PVC insulated, with multistranded Copper conductors, armoured with galvanised steel wire or tape, gland, copper lugs of size 6 Sqmm 3 core, confirming to IS specifications suitable for LT panel including clamp, nut bolt, passing through 20/25mm pipes including cutting of wall / flooring and making good sarface, complete all as specified and directed.
19Supply, lay, fix on wall/pole, 4 Sqmm 3 core copper LT UG cable, 1100 volts grade, PVC insulated, with multistranded Copper conductors, armoured with galvanised steel wire or tape, gland, copper lugs of size 4 Sqmm 3 core, confirming to IS specifications suitable for LT panel including clamp, nut bolt, passing through 20/25mm pipes including cutting of wall / flooring and making good sarface, complete all as specified and directed.
20Taking down carefully copper/aluminum submain/ copper flexible cable wiring/ LT cable, complete all as specified and directed.
21S&F in repairs DB vertical type 8 way VTPN double door load line powder coated alongwith 200 Amp rated Bus bar fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.Note: Thimble/lugs of rating of MCCB should be used with wire for fixing in the MCB.
22S&F in repairs DB vertical type 6 way VTPN double door load line powder coated alongwith 200 Amp rated Bus bar fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.Note: Thimble/lugs of rating of MCCB should be used with wire for fixing in the MCB.
23S&F in repairs DB vertical type 4 way VTPN doubble door load line powder coated alongwith 200 Amp rated Bus bar fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.Note: Thimble/lugs of rating of MCCB should be used with wire for fixing in the MCB.
24S&F in repairs MCB TPN 63 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and directed.
25S&F in repairs MCB TPN 100 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and directed.
26S&F in repairs MCB TPN 125 amps, 'C' series, breaking capacity 16 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and directed.
27S&F in repairs MCB SP 240 volt, 16 to 63 Amps, C series, complete all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
28Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sqm on plan and n.exc 1.5 m in depth and getting out complete in soft/loose soil, complete all as specified and directed.
29All as per item No. 28 above but in hard/dense soil.
30Excavation in trenches not exc 1.5 m wide and not exc 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in hard rock/road cutting/RCC/PCC, complete all as specified and directed.
31Supply and providing sand for sand cushioning for cable protection or filling in trenches of sand in cable ducts after cleaning of ducts, complete all as specified and directed.Note:- for the purpose of payment punned thickness will be measured.
32Returning,filling in soft/loose soil including spreading, levelling, watering, well ramming in layers n.exc 25 cm, complete all as specified and directed.
33Removing of excavated material from the site of work and transporting out of MD land, complete all as specified and directed.
34Supply and providing unreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) of sizes Class LV type I, flat size 250x150x40 mm putting adjecent to each other, complete all as specified and directed.
35Supply and laying tubes light grade, galvanized, 50 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable, complete all as specified and directed.
36Supply and laying tubes light grade, galvanized, 40 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable, complete all as specified and directed.
37M&L cement concrete 1:2:4 type B-1 using 20mm graded aggregate in width for foundation/road filling including including rafts, footings, foundation beams plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
38Taking down for old XLPE UNSV cable from trench/wall/duct, complete all as specified and directed.
39Supplying, laying, commissioning & testing LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required on ground of following sizes:- (a) 300 Sqmm x 3.5 Core.
40All as per item No. 39 but for cable size 240 Sqmm x 3.5 Core.
41All as per sl item No. 39 but for cable size 185 Sqmm x 3.5 Core.
42All as per sl item No. 39 but for cable size 120 Sqmm x 3.5 Core.
43All as per sl item No. 39 but for cable size 95 Sqmm x 3.5 Core.
44All as per sl item No 39 but for cable size 70 Sqmm x 3.5 Core.
45All as per sl item No. 39 but for cable size 50 Sqmm x 3.5 Core.
46All as per sl item No. 39 but for cable size 35 Sqmm x 3.5 Core.
47All as per sl item No. 39 but for cable size 25 Sqmm x 3.5 Core.
48Material & Labour for cable fault detection & route tracing at various locations by all T & P, Equipments for LT CABLE XLPE aluminium conductor including testing and commissioning, complete all as specified and directed.
49Material & Labour for cable jointing kit, in repairs for LT CABLE XLPE aluminium conductor including testing and commissioning complete for the size of 35sqmm X 3.5 Core, complete all as specified and directed.
50All as above item No. 49 but of size 50sqmm X 3.5 Core.
51All as above item No. 49 but of size 70sqmm X 3.5 Core.
52All as above item No. 49 but of size 95sqmm X 3.5 Core.
53All as above item No. 49 but of size 120sqmm X 3.5 Core.
54All as above item No. 49 but of size 150 sqmm X 3.5 Core.
55All as above item No. 49 but of size 240sqmm X 3.5 Core.
56Taking out/down for old cable and rerouting, re laying, saddling the same after checking, meggaring complete LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty of size 10 sqmm X 2 Core to 70sqmm X 3.5 Core including connecting up electric power to panel/feeder box, complete all as specified and directed.
57Taking out/down for old cable and rerouting, re laying, saddling the same after checking, meggaring complete LT underground cables, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty of size 95 sqmm X 3.5 Core to 240 sqmm X 3.5 Core including connecting up electric power to panel/feeder box, complete all as specified and directed.
58Earthing complete with galvanized steel earth plate electrode 600 x 600 x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep Below ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead 25 x 3.15 mm dia by means of bolts, nuts, check nuts and washers of GI including PCC pit in PCC 1:2:4 type B-1 angle iron 40x40x3mm frame with pre-cast RCC 1:2:4 type B-1 cover with XPM weight not less than 4kg/sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal, dust and common salt light grade, GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore 05 metre long and earth wire up to main earthing of pole all as shown in Electrical Plate No 3 of SSR 2009 Part-I, to achieve earthing resistance within 1 Ohm all as specified and testing on completion. Note: Contractor should carry out the earths resistance test in presence of Eng-Incharge. Meggering value earth resistance should be less than 2 Ohm.
59Supply & Fix earth continuty conductor fixed to wall/surface or recess or burried in ground or any situation for loop earthing by 25 X 4 mm GI strip, complete all as specified and directed by Engineer-in-Charge.
60S&F in repairs steel perforated trunking system of size150x30 mm and providing sturdy nuts and bolts for connecting cable trunking steadily onto walls or lying in air steadily with help of metal frame, complete all as specified and directed.
61S&F in repairs PVC trunking system of size 60x30 mm and providing sturdy nuts and bolts for connecting cable as per requirment on site including necessary fixing arrangement, complete all as specified and directed.
62Supply, install, testing and commissioning of factory made LT Panel board outdoor type made totally enclosed dust & vermin proof single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on 'C' channel of appropriate size. Neccessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of apprppriate size. The panel shall be suitablr universal mounting arrengement of thermal protection MCCBs & shall comprise with 500 Amps capacity Aluminium TPN bus bar chamber having 3 phase 4 bus bar system fixed on porceilin insulator with suitable size Aluminium Bus Bar extension till cable chamber and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands. the pannel board shall confirm as per IP 52 complete all as directed with foliowing accessories including taking out old panel. (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item complete all as specified & directed). The panel shall be of complete bus bar system.
63INCOMING(a) Thermal Protection MCCB 4 pole, 415 Volts, 320 Amps, 36 KA with HRC Fuse(for Isolation), 415 V- 02 Nos. (b) Volt meter (digital type) 0-500 volts with selector switch - 01 No.(c) Ammeter (digital type) with 3 Nos CT and selector switch - 01 Set.(d) R,Y B Indicator lamp LED type - 01 Set.OUTGOING(a) Thermal Protection MCCB 3 pole 160 amps, 36 KA, 415 V- 02 No. (b) Thermal Protection MCCB 3 pole 100 amps, 36 KA, 415 V- 02 No. (c) Thermal Protection MCCB 3 pole 63 amps, 36 KA, 415 V- 02 No. (d) Street Light Time Switch - 01 No.(e) Power contactor 3 pole AC 3 rating 32 A - 01 No.
64Supply, install ,testing and commissioning of factory made LT Panel board indoor type made totally enclosed dust & vermin proof single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 2 mm thick as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on 'C' channel of appropriate size. Neccessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of apprppriate size. The panel shall be suitablr universal mounting arrengement of thermal protection MCCBs & shall comprise with 500 Amps capacity Aluminium TPN bus bar chamber having 3 phase 4 bus bar system fixed on porceilin insulator with suitable size Aluminium Bus Bar extension till cable chamber and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands. the pannel board shall confirm as per IP 52 complete all as directed with foliowing accessories including taking out old panel. (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item complete all as specified & directed). The panel shall be of complete bus bar system.
65INCOMING(a) Thermal Protection MCCB 4 pole, 415 Volts, 320 Amps, 36 KA with HRC Fuse(for Isolation), 415 V- 02 Nos. (b) Volt meter (digital type) 0-500 volts with selector switch - 01 No.(c) Ammeter (digital type) with 3 Nos CT and selector switch - 01 Set.(d) R,Y, B Indicator lamp LED type - 01 Set.OUTGOING(a) Thermal Protection MCCB 3 pole 160 amps, 36 KA, 415 V- 02 No. (b) Thermal Protection MCCB 3 pole 100 amps, 36 KA, 415 V- 02 No. (c) Thermal Protection MCCB 3 pole 63 amps, 36 KA, 415 V- 02 No. (d) Street Light Time Switch - 01 No.(e) Power contactor 3 pole AC 3 rating 32 A - 01 No.
66Supply, install, testing and commissioning of factory made LT Panel board indoor type made totally enclosed dust & vermin proof single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 2 mm thick as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size. Neccessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of apprppriate size. The panel shall be suitablr universal mounting arrengement of thermal protection MCCBs & shall comprise with 400 Amps capacity Aluminium TPN bus bar chamber having 3 phase 4 bus bar system fixed on porceilin insulator with suitable size Aluminium Bus Bar extension till cable chamber and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands. the pannel board shall confirm as per IP 52 complete all as directed with foliowing accessories including taking out old panel. (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item complete all as specified & directed). The panel shall be of complete bus bar system.
67INCOMING(a) MCCB 4 pole 250 amps , 36 KA ,415 V- 01 Nos. (b) Volt meter (digital type) 0-500 volts with selector switch - 01 No.(c) Ammeter (digital type) with 3 Nos CT and selector switch - 01 Set.(d) R,Y B Indicator lamp LED type - 01 Set.OUTGOING(a) Thermal Protection MCCB 3 pole 100 amps, 36 KA ,415 V- 02 No. (b) Thermal Protection MCCB 3 pole 63 amps, 36 KA ,415 V- 03 No. (c) MCB TPN 40 Amp, 415 V - 02 Nos. (f) MCB 2 pole, 240 Volts, 40 Amps - 4 No.
68Supply, install ,testing and commissioning of factory made LT Panel board outdoor type made totally enclosed dust & vermin proof single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size. Neccessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of apprppriate size. The panel shall be suitablr universal mounting arrengement of thermal protection thermal protection MCCBs & shall comprise with 300 Amps capacity Aluminium TPN bus bar chamber having 3 phase 4 bus bar system fixed on porceilin insulator with suitable size Aluminium Bus Bar extension till cable chamber and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands. the pannel board shall confirm as per IP 52 complete all as directed with foliowing accessories including taking out old panel. (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item complete all as specified & directed). The panel shall be of complete bus bar system.
69INCOMING(a) Thermal Protection MCCB 4 pole 125 amps , 36 KA ,415 V- 01 Nos. (b ) Volt meter (digital type) 0-500 volts with selector switch - 01 No.(c) Ammeter (digital type) with 3 Nos CT and selector switch - 01 Set.(d) R,Y, B Indicator lamp LED type - 01 Set.OUTGOING(a) Thermal Protection MCCB 3 pole 63 amps, 36 KA ,415 V- 02 No. (b) MCB 2 pole 40 amps, 10 KA, 240 V- 16 No.
70Supply, install ,testing and commissioning of factory made LT Panel board indoor type made totally enclosed dust & vermin proof single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 2 mm thick as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size. Neccessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of apprppriate size. The panel shall be suitablr universal mounting arrengement of thermal protection MCCBs & shall comprise with 300 Amps capacity Aluminium TPN bus bar chamber having 3 phase 4 bus bar system fixed on porceilin insulator with suitable size Aluminium Bus Bar extension till cable chamber and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands. the pannel board shall confirm as per IP 52 complete all as directed with foliowing accessories including taking out old panel. (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item complete all as specified & directed).
71INCOMING(a) Thermal Protection MCCB 4 pole 160 amps, 36 KA, 415 V- 01 Nos. (b ) Volt meter (digital type) 0-500 volts with selector switch - 01 No.(c) Ammeter (digital type) with 3 Nos CT and selector switch - 01 Set.(d) R,Y, B Indicator lamp LED type - 01 Set.OUTGOING(a) MCB 2 pole 40 amps, 10 KA, 240 V- 4 Nos. (b) MCB 2 pole 32 amps, 10 KA, 240 V- 12 Nos. (c) MCB single pole 32 amps, 10 KA , 240 V- 10 Nos. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56321021
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.95 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance To Building Lt Panels, Switch Gears And Cable Tray And Other Connected Items Under Ge (West) Colaba, Mumbai
Basic Detail
Tender No 8281/E8
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 06 Jul 2026
Submission Date 27 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 44.95 Lakhs
Tender Fee 500
EMD 89900
Exemption Available
Document List
8281TenderPages.pdf
BOQ_869723.xls
Tendernotice_1 (2).pdf
543d5407-f4ab-43d5-b1ca-933b6e73d3cd.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
pdf

8281TenderPages.pdf

xls

BOQ_869723.xls

pdf

Tendernotice_1 (2).pdf

html

543d5407-f4ab-43d5-b1ca-933b6e73d3cd.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender