Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56321005

Tender For Repair/Replacement Of Old Electric Meter Panels With Polycarbonate Panel At Dinjan Mil Stn Under Ge Dinjan

Issued by Statutory Bodies & Commissions/Committees · Tinsukia, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Jul 2026
18 days left
EMD
77600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Old Electric Meter Panels With Polycarbonate Panel At Dinjan Mil Stn Under Ge Dinjan

BOQ

Name of Work:- REPAIR/REPLACEMENT OF OLD ELECTRIC METER PANELS WITH POLYCARBONATE PANEL AT DINJAN MIL STN UNDER GE DINJAN
Sl. No. Item Description
1Taking down existing meter Box with all MCCBs/MCBs and Meters and keping the meters in safe custidy for refixing in new panel and making good the disturbed suface by plastering and painting and matching with existing color complete all as specified and directed.
2Demolition of brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
3M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar in 1:4 complete all as specified and directed
4M&L for rendering 10 mm thick internal wall on fair faces of brick work or concrete surfaces in cement Mortar in 1:6 and finished even and smooth (without using extra lime or cement) complete all as specified and directed.
5M&L for two coats of distemper oil emulsion with white or tinted over one coat of primer over and incl 3mm thick wall care putty to make the surface even and smooth on walls complete all as specified and directed.
6M & L for Sub main wiring with two runs of 6 sqmm (Nominal area) single core cable FR PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through providing (new) casing-caping of suitable size, fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, FR PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point complete all as specified and directed. (Note : (a) Casing-caping, two run cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.)
7M&L for Wall Mounting high quality Polycarbonate PC - GFS insulated Panel os size 680 x 950 x - Protection Class II with IP 54 according to IEC 60 529, and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 960 degC in accordance with IEC 60 695-2-11 UL subject 94; Impact strength IK 08(5 Joule) in accordance with DIN EN 50 102. The Panel is in accordance with IEC 61 439-1 & 2.The material should conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1The OEM of board / panel shall be submitted a copy of TYPE TEST REPORT( in accordance with ASTA certification' by CPRI ) of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily with: Temperature Rise. Dielectric Properties. Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current. Degree of Protection Clearance & Creepage Distance. Mechanical Operation Effectiveness of Protective Circuits Degree of ProtectionThe Distribution board Unit should have padlock facility for positive isolation. For avoiding condensation or formation of water droplets inside the Distribution Unit, measures must be taken following safety standard IEC 60364-5-52 using Passive Solutions. For that moisture absorbent material should be considered made of synthetic rubber, super absorbent polymer and nonwoven fabric which should have absorbency of 0.8g (H2O)/1g (product) @25deg C and 95% RH or Higher. The manufacturer / OEM of the Polycarbonate Enclosure and Panel should be same. With supplied Panel, manufacturer Routine test certificate should be submitted and all mentioned type test certificate of the Panel should be for same MOC as mentioned in specification i.e. Thermoplastic Polycarbonate.including of the following Incomer- 125A 4P 25kA MCCB- 1 NoOutgoing - 63A TPN 10kA MCB - 4 Noswith the provision for fixing of 4 Nos Single Phase Energy Meter Complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56321005
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 25-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Old Electric Meter Panels With Polycarbonate Panel At Dinjan Mil Stn Under Ge Dinjan
Basic Detail
Tender No C/8178/E8
Bidding Type Tender
Location
City Tinsukia
State Assam
Key Dates
Publish Date 06 Jul 2026
Submission Date 25 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 77600
Exemption Available
Document List
BOQ_869656.xls
d8a3e2cf-c267-4657-90b4-b7980cb2c37f.html
TENDERFINAL8178.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_869656.xls

html

d8a3e2cf-c267-4657-90b4-b7980cb2c37f.html

pdf

TENDERFINAL8178.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders