Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56320959

Tender For Repair/Maint To Internal Wiring Fitting/Fixtures For The South Zone At Dipatoli Mil Stn Under Ge Dipatoli

Issued by Statutory Bodies & Commissions/Committees · Ranchi, Jharkhand
Tender Value
30 Lakhs
Estimated cost
Bid Submission
25 Jul 2026
13 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint To Internal Wiring Fitting/Fixtures For The South Zone At Dipatoli Mil Stn Under Ge Dipatoli

BOQ

Name of Work:- REPAIR/MAINT TO INTERNAL WIRING FITTING/FIXTURES FOR THE SOUTH ZONE AT DIPATOLI MIL STN UNDER GE DIPATOLI
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
2M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit medium grade of size not less than 25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box and suitable size modular plate for fitting switch, socket etc complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :-
3One light point controlled by one, one way switch 5 Amps
4One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
5One light point controlled by one, two way switch 5 Amps
6One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
7One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
8One bell point controlled by one, bell switch 5 Amps
9Description all as per item No 2 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH, PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH, PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
10S & F for modular Switch flush type single pole 5/6 amp, one way single module 230 Volts complete all as specified and directed at site.
11S & F for modular Switch flush type single pole 5/6 amp, two way single module 230 Volts complete all as specified and directed at site.
12S & F for modular Switch flush type single pole 15/16 amp, 230 Volts complete all as specified and directed at site.
13S & F for modular socket outlet 2/3 pin, 5/6 Amp (2 module) 230 Volts complete all as specified and directed at site.
14S & F for modular socket outlet 2/3 pin, 06/16 Amp (2 module) 230 Volts complete all as specified and directed at site.
15S & F for modular bell push 6 Amp, single module 230 Volts complete all as specified and directed at site.
16S & F for modular fan regulator 2 module complete all as specified and directed at site.
17S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
18S & F for Ceiling rose, surface Bakelite with 3 terminals PVC ISI marked for batten fitting complete all as specified
19S & F for lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
20Supply and fix in replacement Polycarbonate Modular AC Box with 20 to 32Amps Single Pole MCB, enclosure and Heavy Duty ISI Plug Top (White) with indicator and connecting complete all as specified and directed.
21S&F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt batten decorative type high tranmissitvity diffuser, luminous efficacy not less than 110 lumen/watt,THD <10% , Glare Free, natural white, power factor greater than 0.95, Color Temp 6500K(Cool white), CRI 80, In-built surge protection of 4 KVA, 230 volts complete with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
22S & F in replacement wall mounted LED tube light fitting 20 Watts batten for surface mounted, anodized extruded aluminium housing, high tranmissitvity diffuser, luminous efficacy not less than 120 lumen/watt,THD <10% , Glare Free, natural white, power factor greater than 0.95, Color Temp 6500K(Cool white), CRI 80, In-built surge protection of 4 KVA, 230 volts complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 mm from ceiling rose to fitting complete all as specified and as directed.
23S&F in replacement Decorative wall light fixture with brushed Nickel or Brass finish metal design, suitable for B-22 base LED bulb within the frosted glass soft glow body, weather proof, environmental friendly, energy efficient complete with all accessories, prewired complete all as specified and directed.
24S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency 120 lm/W, PMMA diffuser soft glare free light, CRI not less than 80, Surge Protection 4.0kva, IP-65 complete with driver, holders & LED lamp daylight/cool day light (5700K/6500K) suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete.
25S&F in replacement LED light fitting 1x9W/1X10W aluminium body bulkhead luminaires with built-In power LED driver, power factor >0.97, IP-65, Voltage Surge Protection Circuit up to 4 KVa, 100 lumens/watt including connecting up with three core flexible copper conductor cable of suitable size.
26S & F in replacement for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP66 & IK07 for security light fitting luminaire (120 lm/watt), with toughened glass, CRI>80, Power Factor >0.95 with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
27Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed complete all as specified and as directed including taking down old fan and deposit old unsv ceiling fan to MES store yard of AGE E/M Dipatoli
28S & F for energy efficient exhaust fan Copper winding of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection & body earth connection with ceiling rose and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed including taking down old exhaust fan and deposit old unsv exhaust fan to MES store yard of AGE E/M Dipatoli
29Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and as directed including taking down old exhaust fan and deposit old unsv exhaust fan and deposit old unsv exhaust fan to MES store yard of AGE E/M Dipatoli
30S & F in replacement MCCB DB VTPN 4 way 250A rated with metal double door, IP:43 protection, Isolated neutral bar, Insulated busbar assembly, Door earthing, Mechanical impact strength IK 09 suitable for upto 160A 4P MCCB as I/C (Frame 2) and suitable for MCBs as outgoing including grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
31S & F in replacement for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with push/slide locking system suitable for provision of incoming as 4P MCB and outgoing MCBs including filling any blank slot with blanking plates & necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
32S & F in replacement for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with push/slide locking system including filling any blank slot with blanking plates & necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
33S & F in replacement for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with push/slide locking system including filling any blank slot with blanking plates & necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
34Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed.
35S & F in replacement MCB TPN/FP 40 to 100 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
36S & F in replacement MCB SPN 40 to 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
37S & F in replacement MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
38M & L for in replacement for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
39M & L in replacement for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit
40M & L for in replacement for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of 6 sqmm cable, two run of 6 sqmm cable and one run of PVC conduit will be measured as one unit Please Enable Macros to View BoQ information
41M & L for in replacement for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of 6 sqmm cable, two run of 6 sqmm cable and one run of PVC conduit will be measured as one unit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56320959
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 25-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint To Internal Wiring Fitting/Fixtures For The South Zone At Dipatoli Mil Stn Under Ge Dipatoli
Basic Detail
Tender No 8000/2208/E8
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 04 Jul 2026
Submission Date 25 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
Tendernotice_1 (2).pdf
4721733d-0400-490a-845d-5673ddcba9d3.html
BOQ_869478.xls
TENDER2208.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1 (2).pdf

html

4721733d-0400-490a-845d-5673ddcba9d3.html

xls

BOQ_869478.xls

pdf

TENDER2208.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders