Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #56320943

Tender For Comprehensive Day To Day Maintenance/Repair/Rewiring As Applicable For Internal Electrification And Winter Appliances Such As Internal Light Fittings & Fixtures, Point Wiring, Submain Wiring, Flameproof Wiring, Lightening Protection Sysyte

Issued by Statutory Bodies & Commissions/Committees · Jabalpur, Madhya Pradesh
Tender Value
77 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
23 days left
EMD
1.41 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Comprehensive Day To Day Maintenance/Repair/Rewiring As Applicable For Internal Electrification And Winter Appliances Such As Internal Light Fittings & Fixtures, Point Wiring, Submain Wiring, Flameproof Wiring, Lightening Protection Sysytem And Replacement Of Mcbs, Dbs, Repair Of Ceiling/Exhaust Fans & Other Allied Works Of Restricted Area Of Cod And 506 Abw Under Ge (East) Jabalpur

BOQ

Name of Work:- COMPREHENSIVE DAY TO DAY MAINTENANCE/REPAIR/REWIRING AS APPLICABLE FOR INTERNAL ELECTRIFICATION AND WINTER APPLIANCES SUCH AS INTERNAL LIGHT FITTINGS & FIXTURES, POINT WIRING, SUBMAIN WIRING, FLAMEPROOF WIRING, LIGHTENING PROTECTION SYSYTEM AND REPLACEMENT OF MCBS, DBS, REPAIR OF CEILING/EXHAUST FANS & OTHER ALLIED WORKS OF RESTRICTED AREA OF COD AND 506 ABW UNDER GE (EAST) JABALPUR
Sl. No. Item Description
1Supply and fixing in Replacement of switch piano flush button single pole one way, 6 Amps, 240 V for attending day to day complaint including taking down old one complete all as directed.
2Supply and fixing in Replacement of bell push piano flush type 6 amps , 240 V for attending day to day complaint including taking down old one complete all as directed.
3Supply and fixing in Replacement of buzzer door bell, AC 230 volts Single Phase attending day to day complaint including taking down old one complete all as directed.
4Supply and fixing in Replacement of socket outlet 2-in-1 3 pin, 6 Amps flush type for day to day complaint complete including taking down old one complete all as directed.
5Supply and fixing in Replacement of Switch socket combination 2-in-1 3 pin 6 Amps flush type for day to day complaint including taking down old one complete all as directed.
6Supply and fixing in replacement of Switch piano flush button single pole one way, 16 Amps, 230/240 V for day to day complaint including taking down old one complete all as directed.
7Supply and fixing in Replacement of Socket outlet 2-in-1 3 pin, 6 & 16 Amps flush type for day to day complaint including taking down old one complete all as directed.
8Supply and fixing in Replacement of Switch socket combination 3 pin , 6A and 16 Amps flush type universal for day to day complaint including taking down old one complete all as directed.
9Supply and fixing in Replacement of Fan regulator socket type stepped type (electronic ) 1200/1400mm sweep AC ceiling fan for day to day complaint including taking down old one complete all as directed.
10Supply and fixing in Replacement of modular type switch, one way 6 Amps , 1 module for day to day complaint all including taking down old one complete all as directed.
11Supply and fixing in Replacement of modular type socket 3 pin, 6 Amps combined 2 module complete including taking down old one complete all as directed.
12Supply and fixing in Replacement of modular type socket 3 pin, 6 /16 Amps combined 2 module for day to day complaint including taking down old one complete all as directed.
13Supply and fixing in Replacement of modular type switch, one way 16 Amps, 1 module for day to day complaint including taking down old one complete all as directed.
14Supply and fixing in Replacement of PVC plug top 3 pin with easy grip white matte finish tested as per IS 1293, 6 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed.
15Supply and fixing in Replacement of PVC plug top 3 pin with easy grip white matte finish tested as per IS 1293, 16 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed.
16Supply and fixing in replacement of metalic plug top 3 pin with easy grip white matte finish tested as per IS 1293, 15/16 Amp capacity ISI marked for day to day complaint including taking down old one complete all as directed.
17Supply and fixing in Replacement of fan capacitor 2.5 mfd to 3.15 mfd for day to day complaint including taking down old one complete all as directed.
18Material and labour in Replacement of modular sheet cover plate with frame of size 12 module for day to day complaint including taking down old one complete all as directed.
19Material and labour in Replacement of modular sheet cover plate with frame of size 8 module for day to day complaint including taking down old one complete all as directed.
20Material and labour in Replacement of modular sheet cover plate with frame of size 6 module for day to day complaint including taking down old one complete all as directed.
21Material and labour in Replacement of modular sheet cover plate with frame of size 3 module for day to day complaint including taking down old one complete all as directed.
22Material and labour in Replacement of modular sheet cover plate with frame of size 2 module for day to day complaint including taking down old one complete all as directed.
23Material and labour in Replacement of modular sheet cover plate with frame of size 1 module for day to day complaint including taking down old one complete all as directed.
24Material and labour in Replacement of GI/pressed steel terminal switch board of size 12 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
25Material and labour in Replacement of GI/pressed steel terminal switch board of size 8 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
26Material and labour in Replacement of GI/pressed steel terminal switch board of size 6 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
27Material and labour in Replacement of GI/pressed steel terminal switch board of size 4 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
28Material and labour in Replacement of GI/pressed steel terminal switch board of size 3 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
29Material and labour in Replacement of GI/pressed steel terminal switch board of size 1/2 module for day to day complaint including necessary provision for inserting the termial box in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall, electric connection same as existing and taking down old one complete all as directed.
30S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm and 50 mm deep for day to day complaint including taking down old one complete all as directed.
31S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 175 mm x 100mm and 50 mm deep for day to day complaint including taking down old one complete all as directed.
32S&F in Replacement of PVC rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep for day to day complaint including taking down old one complete all as directed.
33S&F in Replacement of old unserviceable 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat/circular of size 10 Sqmm incl taking down old service connection and removing from the side for day to day complaint including taking down old one complete all as directed.
34S&F in Replacement of old unserviceable 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat/circular of size 16 Sqmm incl taking down old service connection and removing from the side for day to day complaint including taking down old one complete all as directed.
35Note : The contractor shall attend to the office of Engr-in-Charge daily in persion or through his authorised representative with necessary T&P and collect the day to day complaint with respect to the area of contract against Item No. 1 to 34 and deposite the complent slip to complent cell after complete the work with user signature.
36Taking down carefully copper/aluminium point wiring ( light,fan,power point or bell point etc) complete including fixture and fitting such as switches,ceiling rose holders & regulators light fittings etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
37Taking down carefully copper/aluminium Sub Main wiring/service connection of any size from surface/connected/existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
38Taking down carefully any type of DBs including MCCBs and MCBs for keeping the old materials into safe custody or for taking credit and making good to the disturbed surface etc complete all as specified and directed.
39M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for One light point controlled by one switch 5/6 Amps.
40ditto as per item No. 38 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps.
41ditto as per item No. 38 but for one Bell Point controlled by one switch 5/6 Amps.
42ditto as per item No. 38 but for one socket point 5 Amp controlled by one switch on same board.
43ditto as per item No. 38 but for one socket point 5 Amp controlled by one switch on Independent board.
44ditto as per item No. 38 but for one light point controlled by two way switch 5/6 Amps.
45All as per item No. 38 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
46Material & Labour for point wiring with PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn through existing concealed/open PVC conduits medium grade not less than 20mm( ISI marked) and including PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch 5/6 Amps.
47ditto as per item No. 40 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps.
48ditto as per item No. 40 but for one Bell Point controlled by one switch 5/6 Amps.
49ditto as per item No. 40 but for one socket point 5 Amp controlled by one switch on same board.
50ditto as per item No. 40 but for one socket point 5 Amp controlled by one switch on Independent board.
51ditto as per item No. 40 but for one light point controlled by two way switch 5/6 Amps.
52All as per item No. 40 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
53M&L point wiring with FRLS PVC insulated unsheathed multistranded copper conductor,conforming to IS-694 of size 1.50 sqmm nominal cross sectional area single core drawn in and including 20 mm size 'medium grade' PVC doubled lock Casing-Capping/PVC conduit and fittings, including, pressed steel concealed terminal switch boxes not less than 1.2mm thick of reqd size factory made duly painted inside and outside with two coats of black bituminous paint over one coat red oxide primer, 3mm thick plastic laminated sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories and making good the disturbed surfaces and match with the existing surfaces complete all as specified and directed for One light Point controlled by one switch 5/6 Amps.
54ditto as per item No. 42 but for one Ceiling fan/Exhaust fan Point controlled by one switch 5/6 Amps.
55ditto as per item No. 42 but for one Bell Point controlled by one switch.
56ditto as per item No. 42 but for one socket point 5 Amp controlled by one switch on same board.
57ditto as per item No. 42 but for one socket point 5 Amp controlled by one switch on Independent board.
58ditto as per item No. 42 but for one light point controlled by two way switch.
59All as per item No. 42 here in above but drawing in with casing caping or conduit on surface all as directed complete with point wiring using 2.5 Sqmm (Nominal area)triple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
60Material and labour for point wiring for explosive atmosphere with 1100 volts grade, PVC insulated single core FRLS cable with stranded copper conductor of size 1.5 sqmm drawn through and including ERW rigid stove enamelled steel conduit of size 25 mm dia with bends, elbows, couplings etc., duly approved by CMRI Dhanbad and as per IS, fixed with PVC FRLS, insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm as an earth wire connected to common earth and earth dolly as per IS specification for one light point controlled by one switch complete all as directed.
61ditto as per item No. 44 but for one Exhaust Fan/Ceiling fan Point controlled by one switch.
62ditto as per item No. 44 but for one socket point 5 Amp controlled by one switch on same board.
63ditto as per item No. 44 but for one socket point 5 Amp controlled by one switch on Independent board.
64Ditto as per item No. 44 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
65Ditto as per item No. 44 here in above but with 1100 Volts grade copper stranded conductor FRLS cable of size 4 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
66Material and labour in replacement for wiring with two single core 6.0 sqmm multi stranded copper conductor, FRLS, PVC insulated, unsheathed cable, ISI marked, drawn into ERW Steel conduit including 6.0 sqmm FRLS, PVC insulated and unsheathed stranded copper conductor as earth wire in surface/recess and making good to the disturbed surfaces to match the existing colour surfaces complete all as specified and directed.Note:- Two runs of 6.0 sqmm copper conductor cable, one run of 6.0 sqmm copper conductor and one run of steel conduit will be measured as one unit.
67Supply and fixing flame proof rotory switch, LM-6 aluminium body enclosure with threaded cover and switch operated by a shrouded knob, single pole, 16 amps, 250 V capacity with double entries way suitable for 20 mm dia ERW threaded rigid steel conduit duly approved by CMRI Dhanbad complete all as directed.
68S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth
69S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth
70S & F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
71S & F bell push flush type 5 Amp complete all as specified and directed
72S & F switch piano flush type 15 Amps, 230 volts, single pole, two way, ISI marked, complete all as specified & directed.
73S & F 5 pin socket outlet, 5/6 Amps / 3 pin 5/6 Amps, flush type, ISI marked, complete all as specified and directed
74S & F switch socket combination 2 in 1, 3 Pin, 5 A flush type , ISI marked, complete all as specified and directed
75S & F switch socket combination 2 in 1, 3 Pin, 15 A flush type universal, ISI marked, complete all as specified and directed
76S & F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed.
77S&F Ceiling Fan regulator electronic type 120 Watt capacity of polycarbonate body ISI marked complete all as specified & directed.
78S & F for modular Switch, single pole, one way and 5/6 Amp, single modular complete all as specified and directed
79S & F for modular Switch, single pole, one way and 15/16 Amp, single modular complete all as specified and directed
80S & F for Bell push modular 6 Amps single module complete all as specified and directed.
81S & F modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amps and 2 pin, 5/6 Amp, 2 module piano flush type complete complete all as specified and directed
82S & F modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amps and 3 pin, 5/6 Amp, 2 module piano flush type complete complete all as specified and directed
83S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed.
84S&F Lamp holder, PVC/polycarbonate type with back plate suitable for battan fittings, complete all as specified & directed.
85S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 Hz, AC supply etc, complete all as specified & directed.
86S&F modular cover plate 1 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
87S&F modular cover plate 2 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
88S&F modular cover plate 3 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
89S&F modular cover plate 4 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
90S&F modular cover plate 6 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
91S&F of modular cover plate 8 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
92S&F modular cover plate 12 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
93S&F modular cover plate 16 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
94S & F Metal flush box 1/2 module complete all as specified and directed.
95S & F Metal flush box 3 module complete all as specified and directed.
96S & F Metal flush box 4 module complete all as specified and directed.
97S & F Metal flush box 6 module complete all as specified and directed.
98S & F Metal flush box 8 module complete all as specified and directed.
99S & F Metal flush box 12 module complete all as specified and directed.
100S & F Metal flush box 16 module complete all as specified and directed.
101S&F in replacement of 3 mm thick Hylam sheet of size 300mm x 250mm including brass screws and washers etc as per required at site complete all as specified and as directed.
102S&F in replacement of PVC insulated, unsheathed twin twisted copper conductor wire of nominal size 23/0.0076, 1100 volt grade, ISI marked, complete all as specified and directed.
103Material and labour for concealed sub-main wiring alongwith earth wire of size of 4 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. Note :- Four runs (with Red, Blue, Yellow colour for Phase + Black colour for Nutral) of 6.0 Sqmm cable, one run ( with Green colour for Earth) of 4.0 Sqmm cable and one run of PVC conduit will be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles.
104Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. NOTE : Two runs of 6.0 sqmm conductor for main and one run of 4.0 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
105Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, all as specified and as directed. NOTE : Two runs of 4.0 sqmm conductor for main and one run of 2.5 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
106S&F in replacement of LED Bulb 5 star rating 230V AC 12 watt warm/cool day light 6500K as per the direction/requirement of site complere all as specified and directed by Engineer-in -charge.
107S & F in replacement LED 9W bulkhead with IP66 protection and IK09 impact resistance suitable surface/wall mounting applications including connecting up with three core flexible copper conductor cable of suitable size from ceilig rose comnplete all as specified and directed.
108S & F in replacement round shape 12 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specefied and directed.
109S&F in replacement IP 20, Class I, LED Mirror light fitting10 W, (or nearest next higher wattage) min 120 LM/watt, natural white/ cool white (6500k), wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size etc complete all as specified.
110S&F in replacement IP 20, Class I, Smart bright Batten Series, LED luminaire using LEDs 20 watt min 120 LM/watt, natural white / cool white (6500k), with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall/ceiling mounting fixed with 02 Nos of PVC round/ square blocks, screws etc(supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification.
111S & F LED luminaire cool day light/warm white as required of size 1'x4' rectangular LED panel 35/36 watt, 220V recessed/Surface mounted type with high efficieny PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
112S & F for LED luminaire cool day/warm white as required 600 mm x 600 mm square LED panel 35/36 watts, 220V recessed/surface type with high efficieny PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
113Supply & fix in replacement of LED Security Light Luminaire 35 watt with 2500 or more lumen warm white/cool day ligh with, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of wall fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint, including pvc flexible hose pipe. complete all as specified and as directed.
114S&F fix in replacement energy saving environmental friendly and robust , open type vertical highbay long life, exclusive innovative die-cast aluminium IP 65/66 industrial light with high power COB LEDs as light source, suitable for highlighting retails space 100 watt LED replacement metal halide industrial light luminarie complete with all accessories, connecting up with twin core twisted flexible copper conductor cable all as specified and directed.
115Supply and fixingfix in replacement LED flood light 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp incl connecting with cable from junction box to light fitting all as per required and directed by Engr-in-charge.
116Supply and fix in replacement of flame proof LED fttings 1X 40 watts, 4' length aluminium alloy, LM-6 ,IP-65/66 protection with wire guadr including provision of two Nos. angle iron on wall suitable size for fixing of FLP fittings and connected to junction box with 1.5 sqmm PVC single copper conductor multi stranded along with flame proof flexible metalic hose conduit all as per manufacturers instructions, duly approved by CMRI Dhanbad complete all as directed.Note: Flame proof flexible hose conduit shall be measured and paid Separately.
117Suuply and fix in replacement of LED flameproof well glass/Flat glass type 30 watt ,230 V,die casting aluminium housing with heat resistant toughned glass /domeglass/external reflector IP-65/66 protection fittings to be fixed in hanging with ceiling/fixing in wall any type and providing some hanging /fixing arrangements for the same all a per required and specified by engg in charge.
118Suuply and fix in replacement for LED flameproof floodlight with superior thermal management, durability and unmatched lumen output with secondary optics and industry leading 120 lm/w system efficacy well glass/Flat glass type 150 watt ,230 V,die casting aluminium housing with heat resistant toughned glass /domeglass/external reflector IP-65/66 protection fittings to be fixed in hanging with ceiling/fixing in wall any type and providing some hanging /fixing arrangements for the same all a per required and specified by engg in charge.
119S & F fix in replacement sheet metal enclosure MCCB DB VTPN 4 Way vertical type 250 A Copper Busbar for each phase Fully insulated busbar & shrouded Neutral bars with provision for DPX³ 160 MCCB as incomer and SP/TP MCB's as outgoing Reversible Door for IP 43 IK-09 DB's system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
120S & F fix in replacement sheet metal enclosure MCB DB TPN 4 Way type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
121S & F fix in replacement sheet metal enclosure MCB DB SPN 8 Way type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
122S&F fix in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with and including one double pole MCB 20A, 10 KA 240 volt and including necessary provision for inserting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directedcomplete all as specified and as directed.
123S&F fix in replacement TPN enclosure with 3P+N+E plug and socket complete with and including one four pole MCB 63 A, 415 volt,IK-08, including necessary provision for inserting in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directedcomplete all as specified and as directed.
124Supply and fix in replacement FLP DB TPN 4 way of die casting aluminium housing with ,IP 66 degree protection ,with proper fixing arrangements with Incoming cable size upto 3.5 core 50 sqmm. With MCB 63 Amps as a incoming TPN, outgoing with 12 Nos of MCB SP rating 6-32 A complete all as specified and directed.
125Supply and fix in replacement FLP DB SPN 6 way of die casting aluminium housing with ,IP 66 degree protection ,with proper fixing arrangements with Incoming cable size upto 3.5 core 50 sqmm. With MCB 63 Amps as a incoming TPN, outgoing with 02 Nos of MCB SP rating 6-32 Acomplete all as specified and directed.
126Suppy and fix in replacement FLP junction boxes 4 way, 100 mm dia as per requirement of all flameproof gas category CMRI approved all as per required and directed by engg in charge.
127Supply and fixing in replacement FLP-WP MCB SP up to 25 Amps, 240 V, 50 HZ Complete all as specified and directed
128Supply and fixing in replacement FLP-WP MCB SPN up to 25 Amps, 240 V, 50 HZ Complete all as specified and directed
129Supply and fixing in replacement FLP-WP MCB FP up to 32 Amps, 415 V, 50 HZ Complete all as specified and directed
130Supply and fixing in replacement FLP-WP MCB TP up to 32 Amps, 415 V, 50 HZ Complete all as specified and directed
131Supply and fixing in replacement FLP-WP Isolator with direct entry SP up to 16 Amps, 240 V, 50 HZ Complete all as specified and directed
132Supply and fixing in replacement FLP-WP Isolator with direct entry DP up to 16 Amps, 240 V, 50 HZ Complete all as specified and directed
133S & F MCB triple Pole and neutral rated capacity 63 Amps, 415 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed.
134S & F MCB single Pole and neutral rated capacity 40 Amps, 240 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed.
135S & F MCB single Pole and neutral rated capacity 5 to 32 Amps, 240 Volts, breaking capcity 10 KA \\"C\\" curve complete all as specified and directed.
136Supply and fix in replacement flexible metalic hose conduit from junction box to tube light fittings of size M20/3/4\\" conduit M x M / FM x M / F 1000mm duly approved by CMRI Dhanbad complete all as directed.
137Taking down ceiling fan sealing cable end, dismantling blades and removing fan and blades to store for repair work complete all as specified and directed.
138Taking down exhaust fan sealing cable end, dismantling blades and motor removing blades and motor to store for repair work including re-fixing at same location complete all as specified by Engr in charge
139M & L for rewinding of Ceiling fan of 1200/1400 sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed.
140Material and labour for rewinding air circulator/wall fan of 450/600 mm sweep with supper enamelled copper wire of existing gauge and turns after dismantling with super enamelled bare insulated copper winding wires including cleaning the slots properly, and testing complete all as directed.
141Material and labour for rewinding padestal fan of 400/450 mm sweep with supper enamelled copper wire of existing gauge and turns after dismantling with super enamelled bare insulated copper winding wires including cleaning the slots properly, and testing complete all as directed.
142M & L for rewinding of Exhaust fan of 300/450 sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed. Please Enable Macros to View BoQ information
143M & L for rewinding of Exhaust fan of 300/450 sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56320943
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 77 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Day To Day Maintenance/Repair/Rewiring As Applicable For Internal Electrification And Winter Appliances Such As Internal Light Fittings & Fixtures, Point Wiring, Submain Wiring, Flameproof Wiring, Lightening Protection Sysytem And Replacement Of Mcbs, Dbs, Repair Of Ceiling/Exhaust Fans & Other Allied Works Of Restricted Area Of Cod And 506 Abw Under Ge (East) Jabalpur
Basic Detail
Tender No 82766/E8
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 04 Jul 2026
Submission Date 01 Aug 2026
Open Date 08 Aug 2026
Finance
Tender Value 77 Lakhs
Tender Fee 1000
EMD 1.41 Lakhs
Exemption Available
Document List
963a7920-5447-4c18-b0ce-88b1444c0aa8.html
BOQ_869553.xls
TENDER.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Aug 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 30 days

Tender Documents

Download All (ZIP) ↓
html

963a7920-5447-4c18-b0ce-88b1444c0aa8.html

xls

BOQ_869553.xls

pdf

TENDER.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders