Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56320922

Tender For Repair/Maint Of Summer Appliances With Plant And Accessories At Af Station Kanheri Hills Under Ge (Af) Thane.

Issued by Statutory Bodies & Commissions/Committees · Thane, Maharashtra
Tender Value
10 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
2 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Summer Appliances With Plant And Accessories At Af Station Kanheri Hills Under Ge (Af) Thane.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Jul-2026 REVISED BOQ BOQ 23-Jul-2026

BOQ

Name of Work:- REPAIR/MAINT OF SUMMER APPLIANCES WITH PLANT AND ACCESSORIES AT AF STATION KANHERI HILLS UNDER GE (AF) THANE.
Sl. No. Item Description
1AMC for, servicing, maintanence, repairing complete for Package type Air conditioning plant of capacity 8.75 TR condensing unit, Model :- DSA1052R1, Make Blue star and kept it in 100% serviceable condition at all times with temperature/ humidity control (temperature 24 degree + 2 degre with RH 55% + 5%) in Equiptment room at AF station Kanheri hill at Technical Area.The following scope of work including the above work. (No. of plant=3 Nos, 2 Nos running one standby) (i) Testing, Checking, serviceing the indoor and out door units, Fresh air duct and return air ducts, all the filter, dumper, grill, electric control panel, Intelligent Microprocessor controller complete. (ii) Three Nos AC plants to be made serviceable condition, Two number will running at at time and one number stand alternatively through auto control switch. (iii) Checking and serviceablity of all controlling equiptment, Push button , ON -OFF switch , Selector switch on PLC Panels for various mode of operation.. (iv) Checking all the connection of cables end termination for any damge or Loose connection .(v) Checking of compressor, condensing coil, Solenoid valves , auto control switch, Automation system. (vi) Checking the pressure of Condensing gas and if required charging the gas.(vii) Checking of all insulating material and repair/replace.(viii) Checking Fresh air /Return duct,dumper,Grill, repair/maintanence/Replace if needed.(ix) Cheking installation of equiptment and repair if found unserviceable. Complete all as specified and directed by Engineer-in-Charge. Note:-(a) Spares for repair including Gas will be measured and paid seperatly in respectively items.(b)Serviceing to be done every month, if additional vist required the same will be born by contractor in his own cost.
2Supply and fixing PCB circuit for intelligent cooling ambient sensor suitable for 8.75 TR AC plant, complete all as specified and directed by Engineer-in-Charge.
3Supply and fixing DLT, HP/LP sensor suitable for 8.75 TR AC plant, complete all as specified and directed by Engineer-in-Charge.
4Supply and fixing thermostate suitable for 8.75 TR AC plant, complete all as specified and directed by Engineer-in-Charge.
5Supply and fixing blade for condenser blower motor suitable for 8.75 TR AC plant, complete all as specified and directed by Engineer-in-Charge.
6Supply and fixing Filter suitable for 8.75 TR AC plant, complete all as specified and directed by Engineer-in-Charge.
7Supply and fixing expansion valve for 8.75 TR AC plant, complete all as specified and directed by Engineer-in-Charge.
8Taking down and dismantling outdoor fan motor of 8.75 TR AC plant and material and labour for rewinding with supper enamelled copper winding wire as per existing pattern including replacement of gun metal bushes, shaft, clamps including testing and commissioning , complete all as specified and directed by Engineer-in-Charge.
9Supply and fixing outdoor (condensor) fan motor of existing capacity and size for 8.75 TR AC plant ,complete all as specified and directed by Engineer-in-Charge.
10S&F in replacement insulation (closed cell elastomeric insulation in tubing) over copper tubing (suction or discharge) wherever required using approved material & size and thickness of insulation as per manufacturers recommendation for 8.75 TR AC plant, complete all as specified and directed by Engineer-in-Charge.
11Dismantling/taking out defective compressor unit and supply and fixing re-appropriated company sealed compressor scroll type of 4.38TR (suitable for 8.75 TR capacity AC plant) obtained from the factory outlet / authorised dealer under their replacement scheme complete including connecting fitting and fixtures making brazing work and leak test and recharging refrigerant including solering of copper pipes, replacement of foundation rubber bushes, nuts, bolts etc complete all as specified and directed by Engineer-in-Charge.Note :- This item shall not include cost of gas and gas charging which shall be measured and paid for separately under respective items .
12Supply only Refrigerant R-22 refrigerant gas. (Note :- Charges for gas charging shall be paid in respective AMC item No.1 & 11.00 of Sch A ), complete all as specified and directed by Engineer-in-Charge.
13Taking down carefully existing storage type geyser 25/35/50 ltr capacity and disconnection of inlet and outlet water connection taking out all accessories inside the body removing nut bolt from base plate assembly cleaning of inside of stainless steel/copper tank with the help of brush, checking any leakage testing of each unserviceable parts/spairs for its functioning and replacement of unserviceable parts, re fixing the same after cleaning and making proper functioning to maintain proper water temperature, complete all as specified and directed by Engineer-in-Charge.Note: (i) The accessories/spare parts which are required to be replaced shall be measured and paid for separately as \\"Supply only\\" under respective items of BOQ.
14Taking out leakage storage type water heater 25/35/50 ltr cap dismantling and taking out the inner tank, find out the leakage point brazing the leakage point and replacement of glass wool insulations using glass wool and refixing the same after testing, complete all as specified and directed by Engineer-in-Charge.
15Supply only heating element of capacity 2/1.5 KW including rubber washer, bolts, clamps etc for geysers of 50/25 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information
16Supply only heating element of capacity 2/1.5 KW including rubber washer, bolts, clamps etc for geysers of 50/25 ltr capacity of any type & make complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56320922
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10 Lakhs
LAST DATE 23-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Summer Appliances With Plant And Accessories At Af Station Kanheri Hills Under Ge (Af) Thane.
Basic Detail
Tender No GE (AF) T-15 OF 2026-27(8621)
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 17 Jul 2026
Submission Date 23 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 10 Lakhs
Tender Fee 500
EMD 20000
Exemption Available
Document List
12faad43-5dc1-4a20-958d-2478d25245b5.html
BOQ_869584.xls
TD8621.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

12faad43-5dc1-4a20-958d-2478d25245b5.html

xls

BOQ_869584.xls

pdf

TD8621.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders