Tender For Repair To Roof Treatment Joinery Sunken Portion Flooring Chajja Facia Sanitary Fittings And Plaster Etc And Allied Works In Aor Of Mh And Adjoining Area Under Age B/R-Ii Of Ge (Army) No 2 Jodhpur As Per Cpp Ser No 18
Tender Overview
Project Description
Tender for Repair To Roof Treatment Joinery Sunken Portion Flooring Chajja Facia Sanitary Fittings And Plaster Etc And Allied Works In Aor Of Mh And Adjoining Area Under Age B/R-Ii Of Ge (Army) No 2 Jodhpur As Per Cpp Ser No 18
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete/mud phuska of any description and in any position not otherwise specifically provided for (such as copings, bands of any type, roof padding, kerbs, sunken etc; overall thickness and removing the dust debris etc to a distance not exc 250 meter from site and disposing the same complete all as specified and as directed by Engineer in charge. |
| 2 | M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates as over roof, for sunken treatment etc. for making good depression/ undulation to make the existing roof surfaces as filling in depression of roof slab/ floor padding/ roof kerbs rounded or chamfered on edges coping etc; complete all as specified and as directed. |
| 3 | M&L for carrying out water proofing treatment for roofs in the following stages -(i) Rendering 10mm thick in cement mortar (1:4), mixed with integral water proofing liquid all as per manufacturer's instructions over concrete surfaces finished even and smooth with out using extra cement. Note : (WPC shell be measured separately and paid for under respective item of schedule).(ii) First coat of bitumen primer confirming to IS 3384 @0.300 Kg/ Sqm over plastered surafces(iii) Second layer of 3.0 mm thick APP modified polymeric membrane with centre core of Single non woven polyster reinforcement and having weight 3 Kg/ Sqm with mineral gravel finish on top complete laid with blown type bitumen confirming to IS 702-1988 grade 85/25 @ 1.20 Kg/ Sqm complete all as specified and as directed.(iv) Finally applying two protective coats of bituminous aluminium based reflective paint to safeguard against UV, including preparing of surfaces of APP modified polymeric membrane (second coat apply after 24 hrs or as per manufacturing instructions). |
| 4 | Dismantling of stone/ brick work masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stone work, serviceable stone aside for reuse and removing unserviceable material in low laying area complete all as specified and as directed. |
| 5 | M&L for squared rubble walling jodhpur type, brought upto course, well bonded bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed. |
| 6 | All as per serial Item No 05 as above item but, except stone complete all as specified and as directed. |
| 7 | Extra over for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling,Jodhpur type, brought upto courses all as specified and as directed. |
| 8 | M&L for brick work with fly ash bricks, built in CM (1:6) straight or curved exceeding 6mtr mean radius complete all as specified and directed. |
| 9 | M&L for Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified. |
| 10 | Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and as directed |
| 11 | M&L for rendering 15 mm thick in CM 1:6 over stone masonary, concrete surfaces, finished even and smooth (without using extra cement), all as specified and as directed. |
| 12 | M&L for 15 mm thick rendering on stone masonary wall surfaces in CM 1:4 finished fair and even all as specified and as directed. |
| 13 | M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 14 | Preparing new plastered surfaces and M&L for applying chalk whitening/ concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of Distemper oil Emulsion on new plastered surfaces complete all as specified and as directed. |
| 15 | Preparing new plastered surfaces and M&L for applying concrete primer and /or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and M&L two coats of cement base paint on new plastered surfaces complete all as specified and as directed. |
| 16 | Preparation of new plastered surfaces of ceiling etc. & applying three coats of lime white wash on ceiling complete all as specified and as directed. |
| 17 | S&F in repair PVC hollow wall lining interlocking type 5-7mm thick plain/ coloured, fitted into the wall with PVC rawal plugs and steel screws including fillets on joints as per manufacturers instruction complete all as specified and directed by Engineer in charge. (Note:- If any minor electricial fittings and fixtures disturbed their-in will be match and fixed as existing.) |
| 18 | S&F in repair Gypsum board 6-8mm thick in ceilling fixed with screw as per manufacturer's instructions, plain/ colour fixed with steel snap grid (powder coated bottom side) with 'T' and 'L' (25mmx30mmx1.00mm thick) section of size 600mm x 600mm placed in ceiling 'L' section fixed to wall with PVC rawal plugs and steel screws @ 600mm centre to center, including provided 5.0 mm dia galvanised bars/ wire suspended @ 1.80 mtr centre to center both sides proper hanging arrangements and maintain levels with adjustable clips, complete all as specified and directed. (Note:- If any minor electricial fittings and fixtures disturbed their-in will be match and fixed as existing). |
| 19 | M&L for Attending complaints of leaking / unserviceable pillar cock, Wall mixer, WHB Mixer, bib taps,two way bib taps, stop valves, 15mm - 20mm dia for making it fully functional and leak proof by carefully including taking down, replacing minor unserviceable parts such as rubber washer, leather washers, jumpers brass 15mm - 20mm size complete all as directed and specified. Note: Major parts such as Spindles / phases of CP pillar cocks, wall mixer, WHB mixer,Two way bib taps,CP bib cocks , Angle cocks replaced if any shall be measured and paid for separately under respective item.(incl adjoining area) |
| 20 | M&L for Attending complaints of leaking / unserviceable , low level flushing cisterns, PVC or chinaware for making it fully functional and leak proof by replacing the defective parts such as rubber washers,PVC levers, PVC/ CP knobs if required complete all as directed and specified. (incl adjoining area) |
| 21 | M&L for Attending complaints of internal water supply pipes,fittings and bottle traps for removing of blockages etc of any description incl removing & clearing of air locks etc., by pressure pump or any other means including taking down and refixing of pipes & fittings and replacing old unserviceable pipes and fitting with new ones complete all as specified and as directed. Note: New GI pipes replaced if any shall be measured and paid under respective item of this schedule as S&F. This item includes for labour part only for removal of blockages of air lock etc. |
| 22 | M&L for Attending complaints for Securing glass of any description in existing wooden frames glazed with putty/ beads including removing loose or decayed putty/ beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work (New lengthof frame reputtied shall be measured) (incl adjoining area) complete all as specified and as directed. |
| 23 | M&L for Attending complaints for Repair to steel Vents/ Doors/ mild steel chowkats or frames/ grills / window & door shutters by replacing unserviceable hinges , handles , peg stay etc by way of welding etc as required , oiling to hinges, setting right and easing of shutters to function properly and painting at welded portion to match the existing surfaces all as specified and directed. |
| 24 | M&L for Welding in repairs exc 2.5cm but n.exc 5cm in length and metal thickness n.exc 6mm of any description and in any position complete all as specified and directed. Note: Supply only hinges etc., shall be measured and paid for separately under respective item. |
| 25 | M&L for Attending complaints for Resecuring/ re-fixing of wooden / PVC shutters of any description and size not exceeding 2.00 Sqm each including taking down (if reqd), easing and adjusting and refixing where ever required and fixing new steel screws complete all as directed and as specified. (incl adjoining area) |
| 26 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150.00mm complete all as specified. |
| 27 | S&F in repair PVC covers for water tanks incl hingeing device & hasp and staple for locking of capacity 500 liters to 1000 liters tanks complete all as specified. |
| 28 | M&L for Attending complaints for Resecuring/ re-fixing of Aluminium door/ window/ vents of any description and size by taking down shutter from frame, opening out joints after taking down glass or particle board, replacing the corner piece & defective section members jointing again refixing the glass pane/ particle board etc and complete all as specified and directed by engineer in charge. Note: (i) Floor spring , door closer , lock , glazing , rubber gasket , aluminum glazing , defective aluminium part, and aluminium beading measured & paid seprately. |
| 29 | Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 30 | Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 31 | Taking down 25mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 32 | S&F 15mm bore steel water tubing medium grade galvanised with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 33 | S&F 20mm bore steel water tubing medium grade galvanised with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 34 | S&F 25mm bore steel water tubing medium grade galvanised with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 35 | Fixing only 15mm bore steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 36 | Fixing only 20mm bore steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 37 | Fixing only 25mm bore steel water tubing any grade with all new fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specifide. |
| 38 | Disconnecting existing PVC tank exc 500 Ltrs and not exc1000 Ltrs setting aside (or lowering if required) for repairs, cleaning, etc; and hoisting if required reconnecting refixing in position complete all as specified and directed. |
| 39 | Disconnecting existing PVC tank exc 250 Ltrs and not exc 500 Ltrs setting aside (or lowering if required) for repairs, cleaning, etc; and hoisting if required reconnecting refixing in position complete all as specified and directed. |
| 40 | S&F in repair 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layered and in white colour hoisted and fixed in position including 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified. |
| 41 | S&F in repair 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layered and in white colour hoisted and fixed in position including 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified. |
| 42 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4.00 sqm each and removing from site or to store, complete all as specified and as directed. |
| 43 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing from site or to store, complete all as specified and as directed. |
| 44 | Taking down shutters any description exc 1.00 sqm but not exc 2.00 Sqm each and removing from site or to store, complete all as specified and as directed. |
| 45 | Taking down shutters any description exc 1.00 sqm but not exc 2.00 Sqm each and refixing the shutter in same opening after easing and adjusting, complete all as specified and as directed. |
| 46 | S&F of pressed steel framed made out of 1.25mm thick MS sheet, of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and as directed. |
| 47 | S&F of pressed steel framed made out of 1.25mm thick MS sheet, of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and as directed. |
| 48 | M&L for cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats etc., complete all as specified and as directed. |
| 49 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in lintels upto 1.50 m clear span, cills , steps, seismic and other similar bands, copings, kneelars, apex stones, bed plates, bed blocks of hold fasts etc including necessary form work , complete all as specified and as directed. |
| 50 | S&F for flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, 30 mm thick, ISI marked, complete all as specified. |
| 51 | S&F of factory made 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated , complete all as specified and as directed. |
| 52 | S&F of Factory made steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed Skeleton shutter jointed internally with flat iron 40x4mm complete including grill of 8/10mm square bars as directed by Engineer incharge, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. (with provision of fixing for cooler if required) all as shown on drawing No CEJZ/TD/20 sheet 1/3 to 3/3 fixed in repairs i.e, incl taking down and removal of old steel windows from site or to store, complete all as specified and as directed. Note:- Guard bar/ grill shall be measured and paid separately under respective item of Sch 'A'. |
| 53 | M&L for fabrication of aluminium powder coated window and door, partitions or similar items any pattern & design (openable with hinges, sliding, tilt and turn, casement , fixed type, villa type, ventilators) fabricated with anodized aluminium rectangular or any type section in frame with approved design & patterns including provn of fixing galvanised mild steel wire cloth on the outer side of frame etc; fixed in position, complete all as specified and as directed. Note:- Glass pane & galvanised mild steel wire cloth shall be measured and paid separately under respective Items of Sch 'A'. |
| 54 | S&F of sheet glass ordinary quality 4 mm thick and glazing with oil putty or fixed with wooden beads or fixed with rubber gasket in squares any size of pane, complete all as specified and as directed. |
| 55 | All as per Ser Item No 58 above item but 4mm thick frosted glass, complete all as specified and as directed. |
| 56 | S&F of galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed. |
| 57 | S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs i.e. Incl removal of old unserviceable wire cloth complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 58 | S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs i.e. Incl removal of old unserviceable wire cloth complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents