BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of ACSR or AAC conductor from pole of any size and capacity, complete all as specified and as directed. |
| 2 | Taking down of old unsv UG cable from trench of any size and capacity, complete all as specified and as directed. |
| 3 | Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtrs wide and n.exc 1.5 mtr. in deep for foundation of poles, stays, cables pipe etc and getting out, complete all as specified and as directed. |
| 4 | Returning filling in, of excavated soil in trenches incl spreading, leveling, watering and well ramming in layers each layers n.exc 25cm thick in soft/loose soil, complete all as specified and as directed. |
| 5 | Removal surplus spoil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point , complete all as specified and as directed. |
| 6 | Supply and spread river sand to required width at bottom and top for cable cushioning all as specified in clause 19.75 of SSR part – I (Note :- thickness of sand will be measured after punning) |
| 7 | Supply and lay common burnt bricks of sub class B old size laid at right angle on the cable complete in trenches for cable protection, complete all as specified and as directed. |
| 8 | Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 25 Sqmm 3.5 core, complete all as specified and as directed. |
| 9 | Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 35 Sqmm 3.5 core, complete all as specified and as directed. |
| 10 | Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 50 Sqmm 3.5 core, complete all as specified and as directed. |
| 11 | Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT electric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 70 Sqmm 3.5 core, complete all as specified and as directed. |
| 12 | Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bots, nuts and screws as specified type 410 SP-31 (09 metres long) including two coat of black bituminous paint internally throughout and externally upto embedded portion and applying two coatsof synthetic enamel paint over a coat of red oxide primer with black and white strip of 30 cm each upto 1.50 metre height and two coats of aluminium paint over a coat of red oxide primer externally on remaning exposed surface after preparation of surface and eraction in position, complete all as specified and as directed. (For Security lights) |
| 13 | Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holesetc not exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out of Hard/dense soil, complete all as specified and as directed. |
| 14 | M & L for cement concrete for foundation fillings and mass conctere type D2 1:4:8 using 40 mm graded aggregate, complete all as specified and as directed. |
| 15 | M & for cement concrete for coping of poles using B1 1:2:4, 20 mm graded aggregate, smooth finishing without using extra cement, complete all as specified and as directed. |
| 16 | M & for cement concrete for foundation fillings and mass conctere type C2 1:3:6 using 40 mm graded aggregate, complete all as specified and as directed. |
| 17 | Supply and fixing 70 W LED New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device, complete all as specified and as directed. |
| 18 | Supply and fixing GI pipe, bracket for street light fittings made out of GI Pipe medium grade 40 mm dia 1.20 m long bent to required angle/shape with and including necessary clamps, nuts, bolts & washers of suitable size and two coats of aluminium paint with a base coat of red oxide primer, complete all as specified and as directed. |
| 19 | Supply and fix PVC insulated unsheathed copper cable of size 1.5 Sqmm 3 core FR PVC for service connections from junction box to light fitting, complete all as specified and as directed. |
| 20 | Supply and fix loopin loopout fuse junction box of made out of thermo plastic Polycarbonate with IP 66/67 weather proof for outdoor installation of size 155x210x92 mm (with knockouts of cable entry) protection with terminals and locking screw fitted with 3 phase with neutral copper Bus Bar, 415 Volts, 50Hz and 6A MCB SP, suitable for cables off sizes and fixing on steel tubular pole at a height not less than 1.5m above ground level with the help of clamps two nos of F1 20 x 3 mm and suitable nuts and bolts, complete all as specified and as directed. |
| 21 | Supply and laying GI pipe 50mm dia light grade for cable protection on pole/road/culvert crossing and for on pedestal, complete all as specified and as directed. |
| 22 | Supply and laying GI pipe 25mm dia light grade for cable protection inside the coping with pole for junction box cable, complete all as specified and as directed. |
| 23 | Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT elctric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 16 Sqmm 2 core, complete all as specified and as directed. |
| 24 | Supply, laying, jointing and testing LT XLPE and PVC insulated, screened, armoured, LT elctric power cables (heavy duty) with aluminium conductor, 1100 Volts Grade conforming to IS-1554 laid in trenches, pole,road crossing walls, floor etc. cross sectional area of 10 Sqmm 2 core, complete all as specified and as directed. |
| 25 | Supply, installation, testing and commissioning of 4 m height Heritage / Zylo series ornamental lighting pole with antique garden lamp, complete in all respects.The pole shall be fabricated from high-quality cast aluminium / cast iron / MS (as approved) with decorative heritage design and suitable for outdoor applications. The pole shall be provided with single ornamental arms and finished with anti-corrosive treatment, powder coating in antique black The fixture shall consist of heritage-style LED garden lantern with minimum 40-60 W LED, having IP 65 protection, high lumen output, and suitable for energy-efficient outdoor lighting. The luminaire shall be complete with driver, diffuser, and all internal wiring.The pole shall be base plate mounted / foundation embedded (as required) including:Foundation bolts, nuts, and washers,Internal wiring with suitable copper cable,Earthing provision,Junction box and necessary accessories,The work includes complete installation, alignment, testing, commissioning, and handover, as per site conditions and direction of Engineer-in-Charge. |
| 26 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH front side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 240 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-(Servent Qtr) |
| 27 | (a) INCOMING |
| 28 | (i) MCCB 4 Pole 415 volts grade 160 Amps rating and 36 KA rupturing capacity - 01 No |
| 29 | (ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 30 | (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No |
| 31 | (iv) CTs ratio 100/5A class ISI marked sets of three each |
| 32 | (v) Indicating lamp-01 set of three |
| 33 | (b) OUTGOING |
| 34 | (i) MCCB 4 Pole 415 volts grade 63 Amps rating and 16 KA rupturing capacity - 04 No |
| 35 | (ii) MCB Double pole 32 AMP rating 30mA - 02 Nos |
| 36 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH front side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 150 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :- (HWP) |
| 37 | (a) INCOMING |
| 38 | (i) MCCB 4 Pole 415 volts grade 100 Amps rating and 16 KA rupturing capacity - 01 No |
| 39 | (ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 40 | (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No |
| 41 | (iv) CTs ratio 100/5A class ISI marked sets of three each |
| 42 | (v) Indicating lamp-01 set of three |
| 43 | (b) OUTGOING |
| 44 | (ii) MCCB 4 pole 63 AMP - 01 Nos |
| 45 | (ii) MCB Double pole 32 AMP - 05 Nos |
| 46 | Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH front side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 600 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-(Major Block) |
| 47 | (a) INCOMING |
| 48 | (i) MCCB 4 Pole 415 volts grade 400 Amps rating and 36 KA rupturing capacity - 01 No |
| 49 | (ii) Digital Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No |
| 50 | (iii) Digital Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No |
| 51 | (iv) CTs ratio 100/5A class ISI marked sets of three each |
| 52 | (v) Indicating lamp-01 set of three |
| 53 | (b) OUTGOING |
| 54 | (i) MCCB 4 Pole 415 volts grade 200 Amps rating and 36 KA rupturing capacity - 01 No |
| 55 | (ii) MCCB 4 Pole 415 volts grade 100 Amps rating and 36 KA rupturing capacity - 02 No |
| 56 | (iii) MCCB 4 Pole 415 volts grade 63 Amps rating and 36 KA rupturing capacity - 02 No |
| 57 | (iv) MCB Double pole 32 AMP rating 30mA - 06 Nos |
| 58 | Dismantling and taking down existing unserviceable/damage HPSV/MH/LED Security light/Flood fitting of any sizes and capacity,complete all as specified and as directed. |
| 59 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 60 | All as per above serial No. 59 but 60 watt capacity complete all as specified and as directed. |
| 61 | All as per above serial No. 59 but 70 watt capacity complete all as specified and as directed. |
| 62 | All as per above serial No.59 but 90 watt capacity complete all as specified and as directed. |
| 63 | Supply and fixing in replacement Garden Light LED type 20 Watt 230 Watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.Note :- The Make, Model & Design Shall be as approved by the Engr-in-Charge. |
| 64 | S&F CS mounted high intensity LED search light, long range, manually & Automatic swiveling in all direction, 250W, beam range 700 meters, Single, LED efficiency>140 lm/w, PF>0.95, CCT 5500K-6500K, Optical grade PMMA/PC lens/reflector efficency >95%, multiple circuit to avoid complete run-down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, average lux at 5 meter -15000 with circle of approx 600mm, working temp : -20 to +60 degree C, input Volt 150-270 V, 50 Hz P.F >0.95, IP -66, confirming to LM79/LM80 as per IS : 10322/ IS:13383. The stand of this search light should be suitable for fixing on railing/platform of watch tower or other plain surface. It is made by steel and suitable for manual rotation of the light on the horizontally (more than 360 degrees) and vertically (more than 45 degrees) with provision of both locking arrangement at desired position. complete all as specified and as directed.Make : Kalin, Cat No - LRFLL-25PC25 or any other make as approved by GE. |
| 65 | Supply and Fixing LED Driver for security lights of Watts upto 20/30/45W to suit the Existing Make, complete all as specified and as directed. |
| 66 | Supply and Fixing LED Driver for security lights of Watts upto 60/70/90 W to suit the Existing Make, complete all as specified and as directed. |
| 67 | S&F GI Bracket bend to shape 1.2mtr long of size 40/32/25mm GI Pipe suitable for LED Street Light Fitting of size 35/60/70W including necessary fittings such as screw, clamps, hold fast etc, complete all as specified and as directed. |
| 68 | Note:- Schedule of credit Rs 48,840.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender