Bids Are invited for Supply Laying Testing And Connecting Xlpe Sheathed Pvc Insulated Screened Pvc Size 3.5 Core 240 Sqmm Complete All As Specified And As Directed. - Supply, Laying, Testing And Connecting Xlpe Sheathed,Pvc Insulated Screened Pvc Bed
Tender Overview
Project Description
Bids Are invited for Supply Laying Testing And Connecting Xlpe Sheathed Pvc Insulated Screened Pvc Size 3.5 Core 240 Sqmm Complete All As Specified And As Directed. - Supply, Laying, Testing And Connecting Xlpe Sheathed,Pvc Insulated Screened Pvc Bedded,Galvanised Steel Strip Of Wire Armoured Electric Power Cable Heavy Duty With Stranded Aluminium Conductor 1100 Volt Grade Of Size 3.5 Core 240 Sqmm Complete All As Specified And As Directed. , Supply Installation Testing And Commissioning Of Silent Type Diesel Engine Driven Generating Set With Governing Class G2 Including Sound Reducing Canopy Sound Level Not More Than 75Db - Supply, Installation Testing And Commissioning Of Silent Type Diesel Engine Driven Generating Set With Governing Class G2 Including Sound Reducing Canopy (Sound Level Not More Than 75Db At A Distance Of 1 Mtr) 14 Guage As Per Guidelines Issued By Central Pollution Control Board (Cpcb Ivplus, 4Plus), 415 Volts, 3 Phase, 50 Hz Supply Complete, Control Panel Suitable For Giving An Output Of 250 Kva And Alternator Of Suitable Capacity And Rpm Coupled With Each Other With Flexible Coupling Mounted On Anti Vibration Pads On Foundation As Recommended By Manufacturer. The Dg Set Shall Comprise Of Self Starter With Batteries, Turbocharger, Water Cooler And Comprising All Standard Fittings, Fixtures & All Piping Etc. As Below (A) Alternator Directly Coupled With Engine And Suitable To Produce 415 Volts, 3 Phase, 4 Wire System, 50 Hz, 0.8 Pf 1500 Rpm Of Capacity 250 Kva All As Per Is 13364 And Upto Date Amendments With H Class Insulation, Self Excited, Self Regulated, Screen Protected Drip Proof Type With Two End Shield Ball / Roller Bearing With D Er Winding In Each Pole, Complete All As Specified And Directed. (B) Engine Water Cooled Diesel Engine (Cpcb Norms Iv Compliance) Developing 105 Bhp Having Self Start Engine (Including Batteries With Provn Of Charging The Batteries And Leads) Suitable To Drive Above Specified Alternator Complete With Foundation (Foundation Design As Per Oem) As Per Is 10001/10002, Coupled Directly Through Flexible Coupling, Multi Cylinder Four Stroke, Cold Starting, 1500 Rpm Industrial Type As Per Bs 649 Or Is 1601 With Ai Electronic Governor Suitable To Regulate Speed Of Dg Set From No Load To Full Load Complete With Fuel Tank Of Capacity As Per Manufacturer S Recommendation, Fuel Lines, Exhaust Pipe Duly Insulated With Asbestos Rope And With Support And Silencer Muffiers Etc. For Continuous Operation And Standard Accessories, Sump Pre Heaters, Cold Start Kit Etc. , M And L Earthing Complete With Gi Steel Earth Plate Electrode Of Size 600Mm X 600Mm X 6Mm Thick Burried Directly In Ground Earth Pit Not Less Than 2.25Mtr - M&L Earthing Complete With Gi Steel Earth Plate Electrode Of Size 600Mm X 600Mm X 6Mm Thick, Burried Directly In Ground, Earth Pit Not Less Than 2.25Mtr Deep Below Normal Ground Level With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To The Galvanised Iron Strip Of Size 25X4mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Steel And Earth Lead Protected By Provision Of 40Mm Bore Gi Pipe Medium Grade And Including Provision Of Concrete Pit In Pcc 1 2 4 Type B 1 (Using 20Mm Grade Crushed Stone Aggregate) With 40Mm Thcik Rcc (Type B 1) Cover Reinforced With 8Mm Dia Tmt Bar Both Ways With 12Mm Dia Round Bar Handle And Frame Of Angle Iron 25X25x3mm With Lugs 02 Nos And 20Mm Bore Gi Light Grade Watering Pipe With Funnel And Wiremesh And Filling Common Salt And Charcol And Test Point With Fixing Arrangements And Including Necessary Excavation In Any Type Of Soil, Returning Filling In And Removing Excavated Soil To A Distance Of 50Mtr From The Site, Complete All As Shown On Electrical Plate No 3 Of Mes Ssr Part I And Directed. , Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth Getting Out In Soft Loose Soil Complete All As Specified And As Directed. - Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth, Getting Out In Soft / Loose Soil, Complete All As Specified And As Directed. , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc. 250Mm In Soft Loose Soil Complete All As Specified And As Directed. - Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 250Mm In Soft/Loose Soil, Complete All As Specified And As Directed. , Removing Excavated Materials Soils Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil Complete All As Specified And As Directed. - Removing Excavated Materials (Soils) Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil, Complete All As Specified And As Directed. , M And L Sand Cushioning Dry In Trenches For Protection Of Ug Cables Below Above And Around The Ug Cable Laid In Trenches Of 230Mm - M&L Sand Cushioning (Dry) In Trenches For Protection Of Ug Cables (Below, Above And Around The Ug Cable Laid In Trenches) Of 230Mm Spread Thickness And Consolidated (Punned) Upto 180Mm Thickness, Complete All As Specified And As Directed.(Note For The Purpose Of Payment, Punned Thickness Of Sand Cushioning Only Shall Be Measured And Paid). , M And L For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable Complete All As Specified And As Directed. - M&L For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable, Complete All As Specified And As Directed. , S And F Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing - S&F Galvanised Iron Pipe 80Mm Bore (Dia) Light Grade For Protection Of Ug Cable, Laid In Floors/ Road Crossing, Fixing To Pole With Mild Steel Cl S, Nuts, Bolts, Etc., Complete All As Specified And As Directed. , S And F Hdpe Dwc Double Walled Corrugated Of Diameter 90 Mm Including Disconnection And Connection Of Cable - S & F Hdpe Dwc (Double Walled Corrugated) Of Diameter 90 Mm Including Disconnection And Connection Of Cable Near Panel/Oh For Pipe Fixing Including Joints Complete All As Directed. , Material And Labour For Manufacturing Installation Testing And Commissioning Of Factory Made And Tested Cpri Approved Amf - Material And Labour For Manufacturing, Installation Testing And Commissioning Of Factory Made And Tested, Cpri Approved Amf Panel For 250 Kva Dg Set, Indoor Type, Weather, Vermin Proof, Free Standing Floor Mounting Type Mounted Of Floor/Over The Duct, With Required Mounting Channel, Cable Alley For All The Feeders, Suitable For 440 Volts, 3 Phase 4 Wire 50Hz Ac Supply System, Conforming To Is 5039, Ip54 Class Protection And Made Of 3Mm Crca Mild Steel Sheet With 50X 50X6mm Angle Iron Frame, Hinged Doors, Front & Rear Opeing And Locking Arrangement With Necessary Bus Bar Arrangment With Insulated Al. Bus Bar 1000 S Rating For Phase & Neutral, 4 Strips, Installed On Epoxy Insulators Housed In Separated Bus Chambers Covered With Heat Shrinkable Sleeves With Necessary Bus Bar Tapings For Mccb With Suitable Capacity Of Al. Bus Bar Strips Including Heat Shrinkable Sleeves, And Providing Extended Bus Bars With Chember Arrangement For Outgoing Cables, Copper Control Wiring Of Required Size For Instruments Including Necessary Pcc In 1 2 4 Type B1 Using 20Mm Graded Stone Aggregate For Platform Of Suitable Size , Prewired With Copper Cable Of Suitable Size All As Standard Practice Of Manufacturer Specifications With The Following Acessories Incomer1 & 2 (Main & Dg)(A) Busbars 1000A Tpn 415Volts 3Phase 4 Wire Color Coaded Aluminium Busbars 1 Lot (B) Mccb 630A Fp Edo 50Ka Microprocessor Based ( O/C, S/C & E/F) Release With Motor, Closing & Shunt, Aux. Contact 4Noplus4nc 2 Nos. (C) Amf Relay (Econ) 1 Nos. (I) Digital Ammeter 1 Nos. (Ii) Digital Voltmeter 1 Nos. (Iii) Ct 1000/5A Cl1 10Va 1 Nos (Iv) Phase Indication Light Red 230V Ac 1 Nos. (V) Phase Indication Light Yellow 230V Ac 1 Nos. (Vi) Phase Indication Light Blue 230V Ac 1 Nos. (Vii) Indication L 22Mm Dia Color Red 240V Ac (On) 2 Nos. (Viii) Indication L 22Mm Dia Color Green 240V Ac (Off) 2 Nos. (Ix) Indication L 22Mm Dia Color Amber 240V Ac (Trip) 2 Nos. Etc. , M And L For Surface Excavation N.Exc Not Exceeding 30 Cm Deep And Averaging 15Cm Deep - M&L For Surface Excavation N.Exc (Not Exceeding) 30 Cmdeep And Averaging 15Cm Deep And Getting Out In Soft/Loose Soil Complete All As Specified And Directed. , M And L For Hardcore Using Broken Stone Or Boulders Of Gauge N Exc. 63 Mm Deposited Spread And Levelled In Layers N Exc. 15 Cm Thick - M&L For Hardcore Using Broken Stone Or Boulders Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface, All As Specified And As Directed. , M And L For Cement Concrete In Foundations Filling And Mass Concrete Type D2 1 4 8 - M&L For Cement Concrete In Foundations, Filling And Mass Concrete Type D2 1 4 8 (Using 40Mm Grade Aggregate) , M And L For Pcc 1 2 4 Type B1 Using 20Mm Grade Aggregate As In Coping For Pole Inclduing Form Work - M&L For Pcc 1 2 4 Type B1 (Using 20Mm Grade Aggregate) As In Coping For Pole Inclduing Form Work And Finishing The Surfaces Even And Smooth Etc Complete All As Specified And Directed. , M And L For Excavating In Post Holes Or Similar Holes Each N Exc 0.5 Cu. M Getting Out Returning Filling In And Ramming Earth - M&L For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm In Soft/Loose Soil Complete All As Specified And As Directed. , S And F For Steel Work In Tubular Trusses Cloumn Purlin Including Special Shaped Washer Nut Bolt Etc. - S & F For Steel Work In Tubular Trusses, Cloumn, Purlin Including Special Shaped Washer, Nut, Bolt Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I.S.1161 1979 Grade St.240 Complete All As Specified. , S And F Prepainted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick - S&F Prepainted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws As Specified , M And L For Preparation Of Steel Surfaces Of Any Description Over 10 Cm - M & L For Preparation Of Steel Surfaces Of Any Description Over 10 Cm In Width Or Girth Not Otherwise Described And Two Coat Of Synthetic Enamel Paint Over One Coat Of Red Oxide Complete All As Specified , M And L For Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 156582006 - M&L For Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 156582006 Of 60 Mm Thickness, M35 Grade With Grey Cement And Pigment All As Specified And Directed. , Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M25 Grade - Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1 3 (1 Cement 3 Coarse Sand), Including Marking Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not More That 5Mm), Including Making Drainage Opening Wherever Required Complete As Specified And As Directed. , M And L For Preparation Of Concrete Kerb Stone Or Plaster Surface Of Any Description Not Otherwise Described Over 10Cm - M&L For Preparation Of Concrete Kerb Stone Or Plaster Surface Of Any Description Not Otherwise Described Over 10Cm Width Or Girth And Applying Two Coat Of Water Based Floor Coat Paint Emulsion Over One Coat Of Self Priming Coat Emulsion By Diluting With 30% To 40% Water Complete All As Specified And Directed By Engrincharge. , S And F 4Pole 630 Changeover Switch With Enclosure Suitable For 415 V Ac 3Phase 4 Wire - S&F 4Pole, 630 Changeover Switch With Enclosure, Suitable For 415 V Ac, 3Phase, 4Wire, 50 Hz System, For Changeover Between Main Supply And Dg Set. The Switch Shall Be Heavyduty, Onload Type Conforming To Is/Iec 609473, With Silver Alloy Contacts And Adequate Breaking Capacity. The Unit Shall Be Mounted On A Sturdy Angle Iron Frame Fixed Over Pcc Block With Necessary Nuts, Bolts And Support Structure. Terminals Shall Be Suitable For Cable/Busbar Connection And Provision For Safe Manual Operation (Or Motorised Operation, If Required) Shall Be Included Complete With All Accessories, Mounting Hardware All As Specified And Directed. Total Quantity : 1424
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supply Laying testing and connecting XLPE sheathed PVC insulated screened PVC size 3.5 core 240 sqmm complete all as specified and as directed. | Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 240 sqmm complete all as specified and as directed. |
| 2 | Supply installation testing and commissioning of silent type Diesel Engine driven generating set with Governing Class G2 including sound reducing canopy sound level not more than 75db | Supply, installation testing and commissioning of silent type Diesel Engine driven generating set with Governing Class G2 including sound reducing canopy (sound level not more than 75db at a distance of 1 mtr) 14 guage as per guidelines issued by Central Pollution Control Board (CPCB IVplus, 4plus), 415 Volts, 3 Phase, 50 Hz supply complete, control panel suitable for giving an output of 250 KVA and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on anti vibration pads on foundation as recommended by manufacturer. The DG Set shall comprise of self starter with batteries, turbocharger, water cooler and comprising all standard fittings, fixtures & all piping etc. as below (a) ALTERNATOR Directly coupled with engine and suitable to produce 415 Volts, 3 Phase, 4 wire system, 50 Hz, 0.8 PF 1500 RPM of capacity 250 KVA all as per IS 13364 and upto date amendments with H Class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball / roller bearing with damper winding in each pole, complete all as specified and directed. (b) ENGINE Water cooled Diesel Engine (CPCB Norms IV compliance) developing 105 BHP having self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM) as per IS 10001/10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS 649 or IS 1601 with AI electronic governor suitable to regulate speed of DG set from no load to full load complete with fuel tank of capacity as per manufacturer s recommendation, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer muffiers etc. for continuous operation and standard accessories, sump pre heaters, cold start kit etc. |
| 3 | M and L earthing complete with GI steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground earth pit not less than 2.25mtr | M&L earthing complete with GI steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly in ground, earth pit not less than 2.25mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the galvanised iron strip of size 25x4mm by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by provision of 40mm bore GI pipe medium grade and including provision of concrete pit in PCC 1 2 4 type B 1 (using 20mm grade crushed stone aggregate) with 40mm thcik RCC (type B 1) cover reinforced with 8mm dia TMT bar both ways with 12mm dia round bar handle and frame of angle iron 25x25x3mm with lugs 02 Nos and 20mm bore GI light grade watering pipe with funnel and wiremesh and filling common salt and charcol and test point with fixing arrangements and including necessary excavation in any type of soil, returning filling in and removing excavated soil to a distance of 50mtr from the site, complete all as shown on electrical plate No 3 of MES SSR part I and directed. |
| 4 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in Soft / Loose Soil, complete all as specified and as directed. |
| 5 | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil complete all as specified and as directed. | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 6 | Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 7 | M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm | M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.(Note For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid). |
| 8 | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. | M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed. |
| 9 | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing | S&F Galvanised Iron Pipe 80mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 10 | S and F HDPE DWC Double Walled Corrugated of Diameter 90 mm including disconnection and connection of cable | S & F HDPE DWC (Double Walled Corrugated) of Diameter 90 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as directed. |
| 11 | Material and labour for manufacturing installation testing and commissioning of factory made and tested CPRI approved AMF | Material and labour for manufacturing, installation testing and commissioning of factory made and tested, CPRI approved AMF panel for 250 KVA DG set, indoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS 5039, IP54 class protection and made of 3mm CRCA mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement with necessary bus bar arrangment with insulated Al. bus bar 1000 Amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCB with suitable capacity of Al. bus bar strips including heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments including necessary PCC in 1 2 4 type B1 using 20mm graded stone aggregate for platform of suitable size , prewired with copper cable of suitable size all as standard practice of manufacturer specifications with the following acessories INCOMER1 & 2 (MAIN & DG)(a) BUSBARS 1000A TPN 415Volts 3Phase 4 Wire Color Coaded Aluminium busbars 1 Lot (b) MCCB 630A FP EDO 50KA Microprocessor Based ( O/C, S/C & E/F) Release with Motor, Closing & Shunt, Aux. Contact 4NOplus4NC 2 Nos. (c) AMF Relay (econ) 1 Nos. (i) Digital Ammeter 1 Nos. (ii) Digital Voltmeter 1 Nos. (iii) CT 1000/5A CL1 10VA 1 Nos (iv) Phase Indication Light RED 230V AC 1 Nos. (v) Phase Indication Light YELLOW 230V AC 1 Nos. (vi) Phase Indication Light BLUE 230V AC 1 Nos. (vii) Indication Lamp 22mm Dia Color Red 240V AC (ON) 2 Nos. (viii) Indication Lamp 22mm Dia Color Green 240V AC (OFF) 2 Nos. (ix) Indication Lamp 22mm Dia Color Amber 240V AC (trip) 2 Nos. Etc. |
| 12 | M and L for Surface excavation n.exc not exceeding 30 cm deep and averaging 15cm deep | M&L for Surface excavation n.exc (not exceeding) 30 cmdeep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 13 | M and L for Hardcore using Broken stone or boulders of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick | M&L for Hardcore using Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, all as specified and as directed. |
| 14 | M and L for Cement concrete in foundations filling and mass concrete type D2 1 4 8 | M&L for Cement concrete in foundations, filling and mass concrete type D2 1 4 8 (using 40mm grade aggregate) |
| 15 | M and L for PCC 1 2 4 type B1 using 20mm grade aggregate as in coping for pole inclduing form work | M&L for PCC 1 2 4 type B1 (using 20mm grade aggregate) as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed. |
| 16 | M and L for Excavating in post holes or similar holes each n exc 0.5 cu. m getting out returning filling in and ramming earth | M&L for Excavating in post holes (or similar holes) each n exc 0.5cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed. |
| 17 | S and F for Steel work in tubular trusses cloumn purlin including special shaped washer nut bolt etc. | S & F for Steel work in tubular trusses, cloumn, purlin including special shaped washer, nut, bolt etc. complete using ERW or induction butt welded tubes conforming to I.S.1161 1979 grade St.240 complete all as specified. |
| 18 | S and F Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick | S&F Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 19 | M and L for preparation of steel surfaces of any description over 10 cm | M & L for preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide complete all as specified |
| 20 | M and L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 156582006 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 156582006 of 60 mm thickness, M35 Grade with grey cement and pigment all as specified and directed. |
| 21 | Providing and laying at or near ground level factory made kerb stone of M25 grade | Providing and laying at or near ground level factory made kerb stone of M25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1 3 (1 cement 3 coarse sand), including marking joints with or without grooves (thickness of joints except at sharp curve shall not more that 5mm), including making drainage opening wherever required complete as specified and as directed. |
| 22 | M and L for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm | M&L for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm width or girth and applying two coat of water based floor coat paint emulsion over one coat of self priming coat emulsion by diluting with 30% to 40% water complete all as specified and directed by EngrinCharge. |
| 23 | S and F 4Pole 630 Amp Changeover Switch with enclosure suitable for 415 V AC 3phase 4 wire | S&F 4Pole, 630 Amp Changeover Switch with enclosure, suitable for 415 V AC, 3phase, 4wire, 50 Hz system, for changeover between Main supply and DG set. The switch shall be heavyduty, onload type conforming to IS/IEC 609473, with silver alloy contacts and adequate breaking capacity. The unit shall be mounted on a sturdy angle iron frame fixed over PCC block with necessary nuts, bolts and support structure. Terminals shall be suitable for cable/busbar connection and provision for safe manual operation (or motorised operation, if required) shall be included complete with all accessories, mounting hardware all as specified and directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender