Tender for Construction Of Gramin Haat In The Parking Area Mc Building Near Lift Shimla ( Sh :- Dismantaling / Demolishing Of Existing Sheds And Construction Of Kiosks ( With Zmartbuild Q-Con Steel Reinforced Wall Of Nxtbloc And Stretch Fabric Cloth Roofing ) For Marketing Platform For Rural Development ) ( Ws& Si And Electrical Work Complete )
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)including carriage of materials within all leads and lifts. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 cement: 3 coarse sand): 6 graded stone aggregate 20mm nominal size) complete within carriage of material in all leads and lifts. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement: 2 coarse sand): 4 graded stone aggregate 20mm nominal size) complete within carriage of material in all leads and lifts. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:5:10(1 Cement: 5 coarse sand: 10 graded stone aggregate |
| 5 | Providing and fixing in position, Zmartbuid Q-con Steel reinfored wall of NXTBLOC making using necessary tools & equipments to install & fabricate the wall thin Cement mortar 1:3 and fastening the walls at end with steel angle and fasteners etc and making the wall smooth using sand paper etc and applying 2 coats of wall putty etc. completed in all respect as per drawings and specifications and under the overall direction of the Engineer-in-charge. |
| 6 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). |
| 7 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.00 mm Thick |
| 8 | Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). Pre-laminated with decorative laminationone side and other side balancing lamination exterior Grade - I MDF Board 25 mm thick confirming to IS:14587 |
| 9 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shaрe & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-inCharge. For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted |
| 10 | Providing and laying vitrified floor tiles of 600mm X 600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @3,30 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 11 | Providing and applying white cement based putty of average thickness 1.00mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including carriage of materials within all leads andlifts. |
| 12 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. including carriage of materials in all leads and lifts (i) Two Coats |
| 13 | Finishing walls with Acrylic Smooth exterior emulsion of required shade :(i) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including carriage of materials within all leads and lifts |
| 14 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 15 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.50 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters complete including carriage of materials within all leads and lifts. |
| 16 | Steel work welded in built up sections/ framed work, including hollow sections (round, square or Rectangular) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel and applying two coates of Deco paint of approved brand shade and manufacture etc complete including carriage of materials in all leads and lifts. (A) In trusses, beams joists, chanels, angles, tees, flats with connection plates or angle cleats as in main and cross beams, hip and jack rafter, purlins connected to common rafters and the like including carriage of materials in all leads and lifts. |
| 17 | Steel work welded in built up sections, including hollow section (Round, Square, or Rectangular) trusses and framed work, including cutting, hoisting xing in position and applying apriming coat of approved steel primer using structural steel and applying two coates of Deco paint of approved brand shade and manufacture etc completeincluding carriage of materials in all leads and lifts. :-In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works complete including carriage of materials within all leads and lifts. |
| 18 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Flashings/ Aprons.( Upto 600 mm) |
| 19 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 20 | Providing and fixing ACP. Sheet 3 mm Thick ceiling/Walls/ Doors/ Lining/Panelling of approved quality with necessary nails etc. complete (frame work to be paid separately) including carriage of materials within all leads and lifts |
| 21 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thickbase of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified andas directed by the Engineer-in-Charge: Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 22 | Providing and fixing Fibre Glass Reinforced Plastic (FRP) or Glass Reinforced concrete 8\\" wide Cornice as per design and drawing / technical specificaion including fixing and hoisting upto all heights including carriage of materials in all leads and lifts. |
| 23 | Second class half brick masonary in common burnt clay building bricks in superstructure upto floor all level.in cement mortar 1:4 (1 cement : 4 sand) including carriage of materials in all leads and lifts. |
| 24 | 15 mm cement plaster 1:6 (1 cement: 4 coarse sand) finished with a floating coat of neat cement on the rough side of half brick. including carriage of materials in all leads and lifts as per direction of the Engineer-in-Charge. |
| 25 | Providing and fixing Stretch Fabric Cloth roofing (of standard design,colour and shade) with screws or clips or all necessary arrangement required to fix the fabric intact with existing roof members including carriage with in all leads and lifts. |
| 26 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and |
| 27 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required |
| 28 | Providing and fixing wash basin with C.I. brackets, 15mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 29 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 30 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia |
| 31 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.(i) 15 mm nominal bore |
| 32 | Providing and fixing 15mm nominal bore C.P. brass angle cock of approved quality conforming to IS:8931 complete including carriage of materials within all leads and lifts. |
| 33 | Providing and fixing 30 cm length uplasticised PVC connection pipe with brass unions15 mm nominal bore complete including carriage of materials upto all leads and lifts and as directed by the Engineer in Charge. |
| 34 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. including carriage of materials within all leads and liftsExternal work (i)20 mm nominal outer dia |
| 35 | Providing and fixing 110 mm Dia PVC Finolex Plain Bend type-B ISI Marked including fixing with approved adhesive etc. complete including carriage of materials within all leads and lifts(i)110mm nominal Dia |
| 36 | Providing and fixing high pressure PVC Finolex type-B spigot and socket , waste and ventialing pipes ISI Marked including fixing with approved adhesive etc. complete including carriage of materials within all leads and lifts and as per the direction of Engineer-in-Charge.(i)110mm Dia |
| 37 | Provding and fixing flush door shutters interior grade, commercial type,core of black-board construction with frame of first class hardwood and well matched commercial ply veneering with bvertical grains of cross bands and face veneers on both faces of shutter including carriage of materials within all leads and lifts:- 35 mm thick including black enamelled M.s. BUTT HINGS |
| 38 | Dismantling steel work in built up sections in angles , tees,flats and channels including all gusset plates , bolts , nut, |Cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 39 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: GS sheet and BP sheet |
| 40 | Providing and laying heavy duty precast cement concrete inter locking paver blocks vibro compacted up to M-50 grade i/c border Or Kurb block grey Or Coloured over Sub- Base of Concrete with 25mm thick average thickness of cement mortar 1:4(1Cement :4 Sand) laid over and jointed with neat cement slorry mixed with pigment to match the shade of blocks including curing rubbing & Polishing Complete (Sub Base Concrete floor to be paid for seprayely (i) 60mm |
| 41 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in including carriage of materials within all leads and lifts. (i)Cement mortar 1:6 (1 cement: 6 Coarse Sand ) |
| 42 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with.polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating inimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified 2 mm thick corrugated (2.5\\" or 4.2\\" or 6\\") orstep-down (2\\" or 3\\" or 6\\") as specified complete within carriage of material in all leads and lifts. |
| 43 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 44 | Group B |
| 45 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 46 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 47 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 48 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 49 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 50 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 51 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 52 | SITC of following type prewired surface / recess mounted (minimum colour code 840) LED light fixture & integrated electronic driver including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. with minimum two years warantee complete as required. (Preferred Makes: Philips/SYSKA Wipro/ Havells/ Crompton/ Bajaj/ Osram) |
| 53 | Surface Type LED Batten 40 watts with Extruded Aluminium housing Suitable for Wall & Conduit Mounting having minimum lumen efficacy as 100 lumens/watt with accessories as required. (Preferred Makes: Philips Model BN 021 LED40S- 6500 PSU GR (4ft) or SS Make) |
| 54 | Surface Type LED Round/Square Panel / Downlighter 12/15 watts having minimum lumen efficacy as 100 lumens/watt with accessories etc. as required (Preferred Makes: Philips Model SM250C LED12S-6500 PSU WH or Similar Superior model of preferred make) |
| 55 | Supplying, installation, testing and commissioning of Surface mounted not more than 10 W LED bulk head fitting with efficacy not less than 100 lumens / watt, Minimum 1000 lumens output.CRI>80 and CCT= 5700-6500K with inbuilt Electronic Driver, THD should be less than 10% and IP-65 rated with suitable Aluminium dia cast/CRCA housing & poly carbonate diffuser and making connection with 1.5 sqmm FRLS Copper conductor single core cable i/c earthing etc. as required. |
| 56 | LED Street Light Luminaire 30 watts with single die ceramic base high power LED light source, IP66 protection, PDC housing with finless design and high impact resistance (IK08) polycarbonate cover with integrated street light optics. (Pole dia.: 32-40mm.) (Make: Philips Model: BRP331 LED36 CW R5N PC PSU S1 V1 OR similar superior model of preferred make) |
| 57 | Supplying and fixing of G.I bracket for mounting of LED street light fitting on wall fabricated out of 32mm dia G.I pipe (medium class) of 1 Meter length having suitable machine made curve with suitable size of reducers, 40mmx3mm flat iron clamp and shall be painted with two coats of red oxide and two coats of aluminium paint including numbering complete as required. |
| 58 | Supplying and fixing following way, horizontal type SPN / TPN, sheet steel, MCB distribution board, 240/ 415 volts, on surface/ recess, complete with metal door, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 59 | 8 Way SPN Double Door |
| 60 | Supplying and fixing following rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 61 | 5 amps to 32 amps, 240 volts Single pole. |
| 62 | 5 amps to 32 amps, 240 volts Double pole. |
| 63 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 64 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 65 | Providing and fixing 25mmx5mm GI strip on surface or in recess for connections etc as required |
| 66 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 67 | S.I.T.C. of compartment alised/cubical M.S. Sheet Metal, free standing Medium Voltage Panel of depth 350mm suitable for operation on 415 volts, 3 phase, 4 wire, 50HZ A.C. supply and fabricated out of 16 SWG MS sheet i/c suitable size /rating 4 strips Aluminum bus bars up to 400A , suitable capacity connection terminals for outgoings, cutting, welding, painting, & sign writings etc. as per specification attached and having arrangement for housing required number of Medium volatge Switchgears, cable entries, CTs, Multi functional meters, control fuses, LED type indication lamps, busbars & internal wiring, minor civil works etc. as per detailed specifications and drawings attached. (Note :- Measurement shall be done as per front surface area of panel) |
| 68 | Supplying and fixing following switchgear ( open executionable type) suitable for operation on 415 volts, 3 phase, 4 wire, 50HZ A.C. supply and metering Instruments for installation in the existing M.S. sheet steel , Medium Voltage, Cubicle Panel including drilling the holes in cubicle panel, making interconnections , etc. as required. |
| 69 | d) Three pole, 100A MCCB with variable Thermal-Magnetic Release, (Release range upto 80-100 Amp), breaking capacity 25KA at 415V with Neutral Link. (M/s L&T D-sine model DN0-100C or equivalent similar superior make) |
| 70 | RYB Indication lamps LED type with suitable size HRC fuses with base & carrier (LED of M/s Esbee L&T , or equivalent similar superior make ) |
| 71 | Supplying & Laying XLPE Aluminium conductor armoured cable of 1.1 KV grade of following sizes on surface/ existing cable tray/pipe etc. as required. |
| 72 | 2 x 10 Sq.mm. |
| 73 | 4 x 25 Sq.mm. |
| 74 | 3½ x 50 Sq.mm. |
| 75 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 76 | 2 x 10 Sq.mm.(19mm) |
| 77 | 4 x 25 Sq.mm.(32mm) |
| 78 | 3½ x 50 Sq.mm.(38mm) |
| 79 | Prepration of Detailed Architectural Drawings, Structural drawings,Working Drawings along with 3 D Plans, 5 No Site visits |
| 80 | Supply Installation and Commissioning of 62.5 KVA, Three Phase, Silent DG Set Engine Make: Greaves/ Kirloskar/ Eicher/ Alternator Make: Greaves/ Kirloskar/ Eicher Three Phase, Silent DG Set comprising of engine suitable, designed & tested on 50℃ ambient temp. and alternator, with AMF panel suitable for DG Set complete with Control cable mounted on a common base, complete with Fuel tank for 10 hour running capacity,Batteries and leads, hospital grade Silencer, Standard Panel, First fill of lube oil, AVM Pads, Acoustic Enclosure as per CPCB 4 norms. Engine Make: Greaves/ Kirloskar/ Eicher/ Alternator Make: Greaves/ Kirloskar/ Eicher Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender