Tender For Deposit Work (Sdf/2025/92) Restoration Of Rain Damages To Lis Brang Chanouta 3Rd Phase In Gp Chanouta In Tehsil Dhar Ur Distt. Mandi Hp (Sh:- supply erection Of Submersible Pumping Machinery At Booster Stage At Chanouta).
Tender Overview
Project Description
Tender for Deposit Work (Sdf/2025/92) Restoration Of Rain Damages To Lis Brang Chanouta 3Rd Phase In Gp Chanouta In Tehsil Dhar Ur Distt. Mandi Hp (Sh:- supply erection Of Submersible Pumping Machinery At Booster Stage At Chanouta).
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Submersible Pumping Set of Kirloskar/KSB/SU/Johnstion make comprising to latest relevant B.I.S. code. The Pump should be fitted with the bronze impeller of suitable alloys as per BIS 8034-376 with upto date ammendments suitable for clear water having greased packed bearing and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900/1450 of reputed make conforming to Kirloskar/Crompton/NGEF specification latest with upto amendments. The pump shall be fitted with a divice to take up expension of water with the heating of motor. The squirrel cage electric induction motor (Water-proof type of suitable H.P. motor of same make as that of pump confcorming to BIS-9287-1979 latest with upto date ammendments totally dust and water proof for submersible duty isolated from the pump by intermedaite casing with double mechanical seal in oil chamber and greased packed lubricated bearing and providing with stainless thurst bearing plate to with stand the vertical load with minimum wear and tear.It should also be fitted with a divice to take up expansion of water with the heating of motor. The pump should we include water level guards, erection clamps, cable clips and depth guage etc and suitable for operation on data given below:- |
| 2 | SITE CONDITIONS:- Static Head 25.00 mtrs Discharge required 20 LPS each set. No. of Pump required. 2 Nos Location of the site of installation of machinery: The site is located at Chanouta a distance of 25 Km from Dharampur. The Altitude of :- The Altitude of place is 600 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Static head in mtrs 19.00 mtrs. Length of R/main 200 mtrs Dia of Rising main 100 mm dia. No of working hours. 8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days. |
| 3 | Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge. |
| 4 | Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 15 Amp capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments. |
| 5 | Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of 0 - 500 Volts range for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments. |
| 6 | ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of 32 Amp. capacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments. |
| 7 | Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to IS: 8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating. |
| 8 | MCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto date amendments with neutral linked under voltage release. |
| 9 | 3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts. |
| 10 | 50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications. |
| 11 | Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer.Supply side Suitable sizes. |
| 12 | Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer). |
| 13 | Supply of suitable cable for water level guard |
| 14 | Supply of supporting clamps. |
| 15 | Supply of cable clips of required size. |
| 16 | Providing and fixing 3 core 6.00mm2 copper cable water proof of reputed make of Havells/Fenolex/L&T make with thimble & flexible pipe complete in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 17 | Erection of all equipment from Sr. No. 1 to 4,6,7,9,11 & 13 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender