Water Resources and Irrigation Government Departments Closing in 6 days TDR #56319670

Tender For Providing Lis To Bhumti Dhar Brahmna From Gamber Khad In Tehsil Arki District Solan Hp Sh_ Laying Jointing Testing And Commissioning Of Hdpe & Gi Pipe Of Various Dia Class And Grades In Distribution Network Including Of Field Outlet Assemb

Issued by Government Departments · Solan, Himachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Jul 2026
6 days left
EMD
1.57 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Lis To Bhumti Dhar Brahmna From Gamber Khad In Tehsil Arki District Solan Hp Sh_ Laying Jointing Testing And Commissioning Of Hdpe & Gi Pipe Of Various Dia Class And Grades In Distribution Network Including Of Field Outlet Assemblies In 1St Call , Excavation In Trenches,Drain Chamber In Earth Work For Pipes Up To All Depths In All Classification Of Earth Work Such As Pick Work, Jumper Work, Saturated Soil Including Balling Or Pumping Out Water, Blasting Soft/Hard Rock Of Chiseling Soft/Hard Rock Where Blasting Is Prohibited In All Lifts Including Jungle Clearance Wherever Required, Trimming And Dressing Of Sides, Levelling Of Bends To Correct Grade Including Shoring/Strutting, Planking, Timbering & Dewatering Wherever Required Stacking The Useable/ Unusable Material/Soil Separately And After Laying, Jointing & Testing Of Pipes, Returning The Useable Soil In Trenches In 15Cm Layers Including Consolidating Of Such Deposited Layer By Ramming And Watering And Then Disposing Of All Surplus Excavated Soil/Unusable Material As Directed By The Engineer-In-Charge With In All Leads And Lifts Complete In All Respects With In All Leads And Lifts As Per Directions Of The Engineer-In-Charge. , Laying, Jointing, Testing And Commissioning At Site In Trenches ( To Level Or Grade) G.I. Pipes Of Following Dia. Heavy/Medium Class Confirming To Is-1239 ( Part-1)( Latest Up To Date Amendments) Of Grade And Wall Thickness As Specified Below Suitable To Withstand Required Hydraulic Test Pressure As Per Bis Code In Random Length Of 4M To 6M With Plain Ends And Jointed With Ms Flanges Conforming To Is-6392-1971 ( Latest Up To Date Amendments) And Welding Of Flanges As Per Is-816-1969 With Electrodes As Per Is-814-1991 Including Required No. And Size Of Ms Nut And Bolts As Per Is-1369-1967 And Compressed Asbestos Fiber Jointing Gaskets Sheets Not Less Than 3Mm In Thickness As Per Is-2712-1998 And Butt Welded Joints. The Welding Of Flanges To Be Done On Both Faces In Two Layers On Outer Face And One Layer On Inner Face To Make The Joints Leak Proof And To The Entire Satisfaction Of The Engineer-In-Charge. The Laying Of Pipes Should Be Confirmed To Is-5822-1994 ( With Latest Up To Date Amendments) And As Per Cpheeo Manual And Will Include All Operation Such As Cutting, Welding Dp Tests Of Butt Welded Joints , Making Pipe Bevelled For Butt Welding , Fabrication Of Bends, Tees, Specials Reducers Etc. And Jointing Including Flushing, Cleaning And Hydraulic Testing Complete In All Respect To The Entire Satisfaction Of Engineer-In-Charge Including Entire Carriage Of Materials Up To All Leads And Lifts. (Earthwork In Trenches, Ms Flanges And Butt Welded Joints To Be Measured And Paid For Separately) , G.I. Pipe As Per Is:1239 (Part-I) :- (Dia-65 Mm)(Medium) , Laying, Jointing And Commissioning Of Hdpe Pipe ( High Density Polyethylene Pipes) Of Following Diameter And Class Confirming To Is 4985-2016 With Butt Fusion Welding Process Including All Necessary Fitting In All Leads And Lifts To The Entire Satisfaction Of Engineer-In-Charge Satisfaction Of Engineer-In-Charge.( Earth Work In Trenches To Be Measured And Paid Separately). , Hdpe Pipe, Pn-4.0, Pipe Grade Pe-80, Pipe Dia 63 Mm , Hdpe Pipe, Pn-4.0, Pipe Grade Pe-80, Pipe Dia 75 Mm , Hdpe Pipe, Pn-4.0, Pipe Grade Pe-80, Pipe Dia 90 Mm , Hdpe Pipe, Pn-4.0, Pipe Grade Pe-80, Pipe Dia 110 Mm , Hdpe Pipe, Pn-6.0, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hdpe Pipe, Pn-6.0, Pipe Grade Pe-100, Pipe Dia 90 Mm , Hdpe Pipe, Pn-6.0, Pipe Grade Pe-100, Pipe Dia 110 Mm , Hdpe Pipe, Pn-6.0, Pipe Grade Pe-100, Pipe Dia 125 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 90 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 110 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 140 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 160 Mm , Hdpe Pipe, Pn-10.0, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hhdpe Pipe, Pn-10.0, Pipe Grade Pe-100, Pipe Dia 75 Mm , Hdpe Pipe, Pn-10.0, Pipe Grade Pe-100, Pipe Dia 90 Mm , Hdpe Pipe, Pn-10.0, Pipe Grade Pe-100, Pipe Dia 110 Mm , Hdpe Pipe, Pn-12.5, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hdpe Pipe, Pn-12.5, Pipe Grade Pe-100, Pipe Dia 75 Mm , Hdpe Pipe, Pn-16.0, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hdpe Pipe, Pn-16.0, Pipe Grade Pe-100, Pipe Dia 75 Mm , Hdpe Pipe, Pn-16.0, Pipe Grade Pe-100, Pipe Dia 125 Mm , Providing , Fixing And Welding M.S. Flanges At Suitable Point Conforming To Following Tables As Per Is:6392-1971( Latest Up To Date Amendments) As Per Is: 6392-1971( Latest Up To Date Amendments) And Welding Of Ms Flanges With G.I. Pipes/Mserw Pipes In Three Layers Two Layer Outer Fase And One Layer On Inner Face ) To Make The Joints Leak Proof ( The Cost Of Providing And Laying Of G.I. Pipes/Mserw Pipes To Be Measured Separately). The Welding Of Flanges Should Conforms To Is 816-1969 With Electrode As Per Is:814-1991 And Required Numbers Of Nuts And Bolts Confirming To Is:1364. The Thickness Of Gaskets Champion Sheet (Cnaf)Not Less Than 3.00 Mm Conforming To Is: 2712-1998. The Work Shall Be Done As Per Entire Satisfaction Of Engineer-In-Charge Including Entire Carriage Of Materials Up To All Leads And Lifts. , Ms Flanges Of Table-17( Dia 65 Mm) , Excavation In Foundation , Tranches Etc. Earth Work Lift Upto 1.5 Mtr. Stacking The Excavated Soil Not More Than 3.00 Mtr Clear From The Edge Of Excavation & Returning The Stacked Soil In 15Cm Layer , When Required Into Plinth Sides Of Foundation Etc. Consolidating Each Deposited Layer By Ramming & Watering & Then Disposing Of All Surplus Excavated Earth As Directed With In All Lead Of 20 Mtr Complete In All Respect As Per Entire Satisfaction Of Engineer-In-Charge. , Providing & Laying Cement Concrete 1:4:8 (1 Cement :4 Sand :8 Graded Stone Agg. 40Mm Nominal Size Curing Complete Encluding The Cost Of Form Work) In Foundation And Plinth As Per Direction & Entire Satisfaction Of Engineer-In-Charge. , Providing And Laying Cement Concrete 1:3:6(1 Cement :3 Sand : 6 Graded Stone Aggregate 40Mm Nominal Size Curing Complete Excluding The Cost Of Form Work) In Foundation And Plinth , As Per Direction & Entire Satisfaction Of Engineer-In- Charge. , Providing Form Work With Mild Steel Plates 3.15 Mm Thick Welded With Angle Iron In Frame 30X30x5mm, So As To Give A Fair Finish Including Centering, Shuttering, Strutting And Propping Etc. With Woodenbalies & Battens, Height Of Propping And Centering Below Supporting Floor To Ceiling Should Be Upto All Heights And Removal Of The Same In Situ -Reinforced Concrete And Plain Concrete Work In All Leads And Lifts I/C Carriage And As Per Direction And Entire Satisfaction Of The Engineer -In-Charge . , Vertical Surfaces Such As Walls(Any Thickness )Partition And The Like Including Attached Pillasters, Buttresses Plinth And String Courses And Like . , Providing And Fixing Fittings And Accesories For Field Outlets (Hdpe Fillings Etc. ) As Per Direction Of Engineer-In-Charge. , 75Mm Dia Pn-4/5/6/8 Hdpe Pipe , 75Mm Dia Pn-6 Hdpe Unequal Tee. , Providing And Fixing And Acessories For Field Outlets (G.I. Fittings) As Per Direction Of Engineer-In-Charge. , G.I. Pipe 65Mm Dia (Mg) , 40Mm Dia Elbow , G.I. Pipe 40Mm Dia , 40Mm Dia G.I. Nippls (6 Length) , 65Mm Dia X40mm Dia G.I. Reducer. , Providing And Fixing 40Mm Dia Ci Butterfly Wheel Valve Kirloskar/ Leader Make As Per Direction And To The Entire Satisfaction Of Engineer -In-Charge. , Providing And Fixing Clamp For Attaching Outlet Pipe As Per Dirction Of Engineer -In-Charge.

BOQ

Name of Work:- Providing LIS to Bhumti Dhar Brahmna from Gamber Khad in Tehsil Arki District Solan HP SH_ Laying Jointing Testing and Commissioning of HDPE & GI Pipe of various dia Class and Grades in distribution network including of field outlet assemblies in 1st call
Sl. No. Item Description
1Excavation in trenches,drain chamber in earth work for pipes up to all depths in all classification of earth work such as pick work, jumper work, saturated soil including balling or pumping out water, blasting soft/hard rock of chiseling soft/hard rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming and dressing of sides, levelling of bends to correct grade including shoring/strutting, planking, timbering & dewatering wherever required stacking the useable/ unusable material/soil separately and after laying, jointing & testing of pipes, returning the useable soil in trenches in 15cm layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil/unusable material as directed by the Engineer-in-Charge with in all leads and lifts complete in all respects with in all leads and lifts as per directions of the Engineer-in-charge.
2Laying, jointing, testing and commissioning at site in trenches ( to level or grade) G.I. pipes of following dia. Heavy/Medium Class confirming to IS-1239 ( Part-1)( latest up to date amendments) of grade and wall thickness as specified below suitable to withstand required hydraulic test pressure as per BIS code in random length of 4m to 6m with plain ends and jointed with MS Flanges conforming to IS-6392-1971 ( latest up to date amendments) and welding of flanges as per IS-816-1969 with electrodes as per IS-814-1991 including required no. and size of MS nut and bolts as per IS-1369-1967 and compressed asbestos fiber jointing gaskets sheets not less than 3mm in thickness as per IS-2712-1998 and butt welded joints. The welding of flanges to be done on both faces in two layers on outer face and one layer on inner face to make the joints leak proof and to the entire satisfaction of the engineer-in-charge. The laying of pipes should be confirmed to IS-5822-1994 ( with latest up to date amendments) and as per CPHEEO manual and will include all operation such as cutting, welding DP tests of butt welded joints , making pipe bevelled for butt welding , fabrication of bends, tees, specials reducers etc. and jointing including flushing, cleaning and hydraulic testing complete in all respect to the entire satisfaction of engineer-in-charge including entire carriage of materials up to all leads and lifts. (Earthwork in trenches, MS Flanges and butt welded joints to be measured and paid for separately)
3G.I. Pipe as per IS:1239 (Part-I) :- (Dia-65 mm)(Medium)
4Laying, jointing and commissioning of HDPE pipe ( High Density Polyethylene pipes) of following diameter and class confirming to IS 4985-2016 with butt fusion welding process including all necessary fitting in all leads and lifts to the entire satisfaction of Engineer-in-charge satisfaction of Engineer-in-charge.( Earth work in trenches to be measured and paid separately).
5HDPE pipe, PN-4.0, Pipe grade PE-80, Pipe dia 63 mm
6HDPE pipe, PN-4.0, Pipe grade PE-80, Pipe dia 75 mm
7HDPE pipe, PN-4.0, Pipe grade PE-80, Pipe dia 90 mm
8HDPE pipe, PN-4.0, Pipe grade PE-80, Pipe dia 110 mm
9HDPE pipe, PN-6.0, Pipe grade PE-100, Pipe dia 63 mm
10HDPE pipe, PN-6.0, Pipe grade PE-100, Pipe dia 90 mm
11HDPE pipe, PN-6.0, Pipe grade PE-100, Pipe dia 110 mm
12HDPE pipe, PN-6.0, Pipe grade PE-100, Pipe dia 125 mm
13HDPE pipe, PN-8.0, Pipe grade PE-100, Pipe dia 63 mm
14HDPE pipe, PN-8.0, Pipe grade PE-100, Pipe dia 90 mm
15HDPE pipe, PN-8.0, Pipe grade PE-100, Pipe dia 110 mm
16HDPE pipe, PN-8.0, Pipe grade PE-100, Pipe dia 140 mm
17HDPE pipe, PN-8.0, Pipe grade PE-100, Pipe dia 160 mm
18HDPE pipe, PN-10.0, Pipe grade PE-100, Pipe dia 63 mm
19HHDPE pipe, PN-10.0, Pipe grade PE-100, Pipe dia 75 mm
20HDPE pipe, PN-10.0, Pipe grade PE-100, Pipe dia 90 mm
21HDPE pipe, PN-10.0, Pipe grade PE-100, Pipe dia 110 mm
22HDPE pipe, PN-12.5, Pipe grade PE-100, Pipe dia 63 mm
23HDPE pipe, PN-12.5, Pipe grade PE-100, Pipe dia 75 mm
24HDPE pipe, PN-16.0, Pipe grade PE-100, Pipe dia 63 mm
25HDPE pipe, PN-16.0, Pipe grade PE-100, Pipe dia 75 mm
26HDPE pipe, PN-16.0, Pipe grade PE-100, Pipe dia 125 mm
27Providing , fixing and welding M.S. flanges at suitable point conforming to following tables as per IS:6392-1971( latest up to date amendments) as per IS: 6392-1971( latest up to date amendments) and welding of MS flanges with G.I. pipes/MSERW pipes in three layers two layer outer fase and one layer on inner face ) to make the joints leak proof ( The cost of providing and laying of G.I. pipes/MSERW Pipes to be measured separately). The welding of flanges should conforms to IS 816-1969 with electrode as per IS:814-1991 and required numbers of nuts and bolts confirming to IS:1364. The thickness of gaskets champion sheet (CNAF)not less than 3.00 mm conforming to IS: 2712-1998. The work shall be done as per entire satisfaction of Engineer-in-charge including entire carriage of materials up to all leads and lifts.
28MS Flanges of Table-17( Dia 65 mm)
29Excavation in foundation , tranches etc. Earth work lift upto 1.5 mtr. Stacking the Excavated soil not more than 3.00 mtr clear from the edge of excavation & returning the stacked soil in 15cm layer , when required into plinth sides of foundation etc. Consolidating each deposited layer by ramming & watering & then disposing of all surplus excavated earth as directed with in all lead of 20 mtr complete in all respect as per entire satisfaction of Engineer-in-Charge.
30Providing & laying cement concrete 1:4:8 (1 cement :4 sand :8 graded stone Agg. 40mm nominal size curing complete encluding the cost of form work) in foundation and plinth as per direction & entire satisfaction of Engineer-in-Charge.
31Providing and laying cement concrete 1:3:6(1 Cement :3 Sand : 6 graded stone aggregate 40mm nominal size curing complete excluding the cost of form work) in foundation and plinth , as per direction & entire satisfaction of Engineer-in- charge.
32Providing form work with mild steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centering, shuttering, strutting and propping etc. with woodenBalies & battens, height of propping and centering below supporting floor to ceiling should be upto all heights and removal of the same in situ -reinforced concrete and plain concrete work in all leads and lifts i/c carriage and as per direction and entire satisfaction of the Engineer -in-charge .
33Vertical surfaces such as walls(any thickness )partition and the like including attached pillasters, buttresses plinth and string courses and like .
34Providing and fixing fittings and accesories for field outlets (HDPE fillings etc. ) as per direction of Engineer-in-charge.
3575mm dia PN-4/5/6/8 HDPE Pipe
3675mm dia PN-6 HDPE unequal Tee.
37Providing and fixing and acessories for field outlets (G.I. Fittings) as per direction of Engineer-in-charge.
38G.I. Pipe 65mm dia (MG)
3940mm dia elbow
40G.I. Pipe 40mm dia
4140mm dia G.I. Nippls (6\\" length)
4265mm dia x40mm dia G.I. Reducer.
43Providing and fixing 40mm dia CI Butterfly wheel valve Kirloskar/ leader make as per direction and to the entire satisfaction of Engineer -in-charge.
44Providing and fixing clamp for attaching outlet pipe as per dirction of Engineer -in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56319670
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 13-07-2026
Authority
Authority Name Irrigation And Public Health Department
Work Description Tender for Providing Lis To Bhumti Dhar Brahmna From Gamber Khad In Tehsil Arki District Solan Hp Sh_ Laying Jointing Testing And Commissioning Of Hdpe & Gi Pipe Of Various Dia Class And Grades In Distribution Network Including Of Field Outlet Assemblies In 1St Call , Excavation In Trenches,Drain Chamber In Earth Work For Pipes Up To All Depths In All Classification Of Earth Work Such As Pick Work, Jumper Work, Saturated Soil Including Balling Or Pumping Out Water, Blasting Soft/Hard Rock Of Chiseling Soft/Hard Rock Where Blasting Is Prohibited In All Lifts Including Jungle Clearance Wherever Required, Trimming And Dressing Of Sides, Levelling Of Bends To Correct Grade Including Shoring/Strutting, Planking, Timbering & Dewatering Wherever Required Stacking The Useable/ Unusable Material/Soil Separately And After Laying, Jointing & Testing Of Pipes, Returning The Useable Soil In Trenches In 15Cm Layers Including Consolidating Of Such Deposited Layer By Ramming And Watering And Then Disposing Of All Surplus Excavated Soil/Unusable Material As Directed By The Engineer-In-Charge With In All Leads And Lifts Complete In All Respects With In All Leads And Lifts As Per Directions Of The Engineer-In-Charge. , Laying, Jointing, Testing And Commissioning At Site In Trenches ( To Level Or Grade) G.I. Pipes Of Following Dia. Heavy/Medium Class Confirming To Is-1239 ( Part-1)( Latest Up To Date Amendments) Of Grade And Wall Thickness As Specified Below Suitable To Withstand Required Hydraulic Test Pressure As Per Bis Code In Random Length Of 4M To 6M With Plain Ends And Jointed With Ms Flanges Conforming To Is-6392-1971 ( Latest Up To Date Amendments) And Welding Of Flanges As Per Is-816-1969 With Electrodes As Per Is-814-1991 Including Required No. And Size Of Ms Nut And Bolts As Per Is-1369-1967 And Compressed Asbestos Fiber Jointing Gaskets Sheets Not Less Than 3Mm In Thickness As Per Is-2712-1998 And Butt Welded Joints. The Welding Of Flanges To Be Done On Both Faces In Two Layers On Outer Face And One Layer On Inner Face To Make The Joints Leak Proof And To The Entire Satisfaction Of The Engineer-In-Charge. The Laying Of Pipes Should Be Confirmed To Is-5822-1994 ( With Latest Up To Date Amendments) And As Per Cpheeo Manual And Will Include All Operation Such As Cutting, Welding Dp Tests Of Butt Welded Joints , Making Pipe Bevelled For Butt Welding , Fabrication Of Bends, Tees, Specials Reducers Etc. And Jointing Including Flushing, Cleaning And Hydraulic Testing Complete In All Respect To The Entire Satisfaction Of Engineer-In-Charge Including Entire Carriage Of Materials Up To All Leads And Lifts. (Earthwork In Trenches, Ms Flanges And Butt Welded Joints To Be Measured And Paid For Separately) , G.I. Pipe As Per Is:1239 (Part-I) :- (Dia-65 Mm)(Medium) , Laying, Jointing And Commissioning Of Hdpe Pipe ( High Density Polyethylene Pipes) Of Following Diameter And Class Confirming To Is 4985-2016 With Butt Fusion Welding Process Including All Necessary Fitting In All Leads And Lifts To The Entire Satisfaction Of Engineer-In-Charge Satisfaction Of Engineer-In-Charge.( Earth Work In Trenches To Be Measured And Paid Separately). , Hdpe Pipe, Pn-4.0, Pipe Grade Pe-80, Pipe Dia 63 Mm , Hdpe Pipe, Pn-4.0, Pipe Grade Pe-80, Pipe Dia 75 Mm , Hdpe Pipe, Pn-4.0, Pipe Grade Pe-80, Pipe Dia 90 Mm , Hdpe Pipe, Pn-4.0, Pipe Grade Pe-80, Pipe Dia 110 Mm , Hdpe Pipe, Pn-6.0, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hdpe Pipe, Pn-6.0, Pipe Grade Pe-100, Pipe Dia 90 Mm , Hdpe Pipe, Pn-6.0, Pipe Grade Pe-100, Pipe Dia 110 Mm , Hdpe Pipe, Pn-6.0, Pipe Grade Pe-100, Pipe Dia 125 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 90 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 110 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 140 Mm , Hdpe Pipe, Pn-8.0, Pipe Grade Pe-100, Pipe Dia 160 Mm , Hdpe Pipe, Pn-10.0, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hhdpe Pipe, Pn-10.0, Pipe Grade Pe-100, Pipe Dia 75 Mm , Hdpe Pipe, Pn-10.0, Pipe Grade Pe-100, Pipe Dia 90 Mm , Hdpe Pipe, Pn-10.0, Pipe Grade Pe-100, Pipe Dia 110 Mm , Hdpe Pipe, Pn-12.5, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hdpe Pipe, Pn-12.5, Pipe Grade Pe-100, Pipe Dia 75 Mm , Hdpe Pipe, Pn-16.0, Pipe Grade Pe-100, Pipe Dia 63 Mm , Hdpe Pipe, Pn-16.0, Pipe Grade Pe-100, Pipe Dia 75 Mm , Hdpe Pipe, Pn-16.0, Pipe Grade Pe-100, Pipe Dia 125 Mm , Providing , Fixing And Welding M.S. Flanges At Suitable Point Conforming To Following Tables As Per Is:6392-1971( Latest Up To Date Amendments) As Per Is: 6392-1971( Latest Up To Date Amendments) And Welding Of Ms Flanges With G.I. Pipes/Mserw Pipes In Three Layers Two Layer Outer Fase And One Layer On Inner Face ) To Make The Joints Leak Proof ( The Cost Of Providing And Laying Of G.I. Pipes/Mserw Pipes To Be Measured Separately). The Welding Of Flanges Should Conforms To Is 816-1969 With Electrode As Per Is:814-1991 And Required Numbers Of Nuts And Bolts Confirming To Is:1364. The Thickness Of Gaskets Champion Sheet (Cnaf)Not Less Than 3.00 Mm Conforming To Is: 2712-1998. The Work Shall Be Done As Per Entire Satisfaction Of Engineer-In-Charge Including Entire Carriage Of Materials Up To All Leads And Lifts. , Ms Flanges Of Table-17( Dia 65 Mm) , Excavation In Foundation , Tranches Etc. Earth Work Lift Upto 1.5 Mtr. Stacking The Excavated Soil Not More Than 3.00 Mtr Clear From The Edge Of Excavation & Returning The Stacked Soil In 15Cm Layer , When Required Into Plinth Sides Of Foundation Etc. Consolidating Each Deposited Layer By Ramming & Watering & Then Disposing Of All Surplus Excavated Earth As Directed With In All Lead Of 20 Mtr Complete In All Respect As Per Entire Satisfaction Of Engineer-In-Charge. , Providing & Laying Cement Concrete 1:4:8 (1 Cement :4 Sand :8 Graded Stone Agg. 40Mm Nominal Size Curing Complete Encluding The Cost Of Form Work) In Foundation And Plinth As Per Direction & Entire Satisfaction Of Engineer-In-Charge. , Providing And Laying Cement Concrete 1:3:6(1 Cement :3 Sand : 6 Graded Stone Aggregate 40Mm Nominal Size Curing Complete Excluding The Cost Of Form Work) In Foundation And Plinth , As Per Direction & Entire Satisfaction Of Engineer-In- Charge. , Providing Form Work With Mild Steel Plates 3.15 Mm Thick Welded With Angle Iron In Frame 30X30x5mm, So As To Give A Fair Finish Including Centering, Shuttering, Strutting And Propping Etc. With Woodenbalies & Battens, Height Of Propping And Centering Below Supporting Floor To Ceiling Should Be Upto All Heights And Removal Of The Same In Situ -Reinforced Concrete And Plain Concrete Work In All Leads And Lifts I/C Carriage And As Per Direction And Entire Satisfaction Of The Engineer -In-Charge . , Vertical Surfaces Such As Walls(Any Thickness )Partition And The Like Including Attached Pillasters, Buttresses Plinth And String Courses And Like . , Providing And Fixing Fittings And Accesories For Field Outlets (Hdpe Fillings Etc. ) As Per Direction Of Engineer-In-Charge. , 75Mm Dia Pn-4/5/6/8 Hdpe Pipe , 75Mm Dia Pn-6 Hdpe Unequal Tee. , Providing And Fixing And Acessories For Field Outlets (G.I. Fittings) As Per Direction Of Engineer-In-Charge. , G.I. Pipe 65Mm Dia (Mg) , 40Mm Dia Elbow , G.I. Pipe 40Mm Dia , 40Mm Dia G.I. Nippls (6 Length) , 65Mm Dia X40mm Dia G.I. Reducer. , Providing And Fixing 40Mm Dia Ci Butterfly Wheel Valve Kirloskar/ Leader Make As Per Direction And To The Entire Satisfaction Of Engineer -In-Charge. , Providing And Fixing Clamp For Attaching Outlet Pipe As Per Dirction Of Engineer -In-Charge.
Basic Detail
Tender No ARK-SOL01-425-8213-63
Bidding Type Tender
Location
City Solan
State Himachal Pradesh
Key Dates
Publish Date 04 Jul 2026
Submission Date 13 Jul 2026
Open Date 13 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 2000
EMD 1.57 Lakhs
Exemption Not Available
Document List
2b87d0e8-77bf-4cd6-b5b7-36383de6b028.html
BOQ_204539.xls
Form_6_LIS_Bhumti_HDPE.pdf
Form_8_LIS_Bhumti_HDPE.pdf
Tendernotice_1.pdf
Term_Condition_LIS_Bhumti_HDPE.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

2b87d0e8-77bf-4cd6-b5b7-36383de6b028.html

xls

BOQ_204539.xls

pdf

Form_6_LIS_Bhumti_HDPE.pdf

pdf

Form_8_LIS_Bhumti_HDPE.pdf

pdf

Tendernotice_1.pdf

pdf

Term_Condition_LIS_Bhumti_HDPE.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders