Tender For Special Repair To Bldg No T-215 And T-222 (Ors Living) Of 219 (I) Fd Wksp (Spl) At Pratapur Under Ge 873 Ews
Tender Overview
Project Description
Tender For Special Repair To Bldg No T-215 And T-222 (Ors Living) Of 219 (I) Fd Wksp (Spl) At Pratapur Under Ge 873 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Jul-2026 | BOQ | BOQ | 25-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation board/slabs/ blanket any thickness including cover filllets. |
| 2 | M&L 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in ceiling complete all as specified. |
| 3 | M&L 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in Wall complete all as specified. |
| 4 | Dismantling timber framed in fillets,rails, posts rafters,purlines, etc under 40 sq cm in section complete all as specified. |
| 5 | M&L second class Hardwood plain filllets, rectangular in section, clean sawn, secured with nails exc 13 and n.exc 25 Sqm complete all as specified. |
| 6 | M&L 18/19mm teak wood lipping 6mm thick for block board or veneered particle board complete fixed with nails complete all as specified. |
| 7 | Dismantling of plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed by Engr-in-charge. |
| 8 | Dismantiling Wrought iron or mild steel work of any description not otherwise provided for all as specified. |
| 9 | S & F Roof trusses Fe 410W (grade-E-250)quality A (framed )trussed ,purlins crane gantries rails etc(beam tee angle channel or flat sections) complete all as specified. |
| 10 | S&F Galvanised MS sheeting of 0.63 mm thick corrugated ISI Marked and made of shakti with two cougation side laps and fixed with J hookes two framed work with PVC and steel washers as in roof & wall all as spd and as drected by Engr-in-Charge |
| 11 | S&F Plain, galvanised, mild steel sheeting of 0.63 mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 all as spd and as drected by Engr-in-Charge |
| 12 | M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide premier.(camouflage pattern) all as specified. |
| 13 | Demolition Cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified. |
| 14 | M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) complete all as specified. |
| 15 | M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4 complete all as specified. |
| 16 | M&L for 50 mm cement concrete type-C1 using 1:3:6 as in plinth protection finished even and smooth , without using extra cement incl necessary form work complete all as specified. |
| 17 | M&L 75 mm Cement concrete type D- 2, 1:4:8(40mm graded aggregate) as in sub base complete all as specified. |
| 18 | M & L Sand filling under floors or in foundations including watering and consolidation complete all as specified. |
| 19 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete all as specified. |
| 20 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified. |
| 21 | Taking down chowkhat or door frames including shutters exc 1.5 sqm n exc 4 sqm each complete all as specified. |
| 22 | S&F plain, solid, straight chowkats of second class hard wood and frames, wrough, framed rebated on the solid, rounded or chemfered, put together with glue pinned at joints complete all as specified. |
| 23 | S & F 35mm thick, 2nd class HW, plain framed, panelled shutter (one panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified |
| 24 | M&L for preparation of new wooden surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of pink primer.complete all as specified. |
| 25 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified. |
| 26 | M&L Sheet glass of 5.5 mm thick,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified. |
| 27 | S&F mild steel 30cm long hold fast conforming to Fe.290. Gde-E-165 of Sectiion complete all as specified.. |
| 28 | M&L for Providing cement concrete type B-0, 1:2:4 ( using 20mm graded crushed stone aggregate) Ditto, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified. |
| 29 | S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified. |
| 30 | S&F 100 mm long butt hinges medium weight cold rolled MS and fixed complete all as specified. |
| 31 | S&F 150 mm MS anodised,barrel tower bolts of extruded section and fixed complete all as specified. |
| 32 | S&F 200 mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified. |
| 33 | S&F 150mm Aluminium handles, cast type, anodised complete all as specified. |
| 34 | S&F in repair Door closer hydraulically regulated,designation No. 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified. |
| 35 | S & F 30 mm thick, 1st class plain framed, panelled shutter (any number panels ) with in panels of timber flat on both sides (feather edged ) or of veneered particle medium density ,wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified. |
| 36 | S&F 2nd class soft wood 30 mm thickness Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete al as specified &directed by Engr-In- Charge. |
| 37 | S&F mild steel, cold rolled, medium weight butt hinges 75mm, fixed with screws to wooden frames or fixed with welding to iron frames complete all as specified and directed. |
| 38 | S&F 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed. |
| 39 | S&F for 4 mm thick sheet glass ,ordinary quality and glazing with oil puttyin square n.exe 0.5 sqm each panes complete all as specified & directed. |
| 40 | Demolition of Brickwork or stone/ boulder masonry/ PCC block masonary , built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. |
| 41 | M&L Precast cement concrete block masonry with solid blocks exc 10 cm in width and set in cm 1:6, type C1 1:3:6 (20 mm graded aggregate) complete all as specifeid. |
| 42 | Taking down cement or cement lime plaster of any description on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and as directed |
| 43 | M&L, Rendering 15mm thick on fair faces of brick work finished even and fair in CM 1:4, complete all as specifeid. |
| 44 | M&L, for prepartion of newly plastered wall surfaces of any description applying Two coat of cement base paint /over a wall of primer complete all as specifeid and direct |
| 45 | M & L for 100 mm thick PCC 1:4:8 type D-2(40 mm graded crushed stone agg) in sub base coarse omplete all as specifeid and direct |
| 46 | M&L for chequered cement concrete tiles 20cm x 20 cm x 25cm thick , set jointed 20mm screed bed in CM 1:4 and pointed in neat cement slurry in floor with grey pigment cement and pigment complete as spd and directed by Engineer -in -charge. |
| 47 | M&L for providing cement concrete 1:2:4 type B-1 (20 mm graded crushed stone aggregate ) in rounded or chamferd on edges bed plates kerbs water troughsand the like including slightly rounded or chamfered angles as directed. |
| 48 | M&L for Providing cement concrete type C-1, 1:3:6 ( using 20mm graded crushed stone aggregate), 75mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays complete all as specified and directed. |
| 49 | Taking down carefully damaged copper/aluminum point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, cassing & capping, pendants, sockets, light fitting etc and making good disturbed surfaces of wall/roof complete all as specified and directed. |
| 50 | Taking down of MCB DB/TPN 8 way including mcb sp and spn and making good of wall complete all as specified and directed. |
| 51 | M&L Point wiring with 1.5 Sqmm (nominal area) copper conductor FRLS-H cable (multi-stranded) PVC insulated and unsheathed electric cable 1100 volts drawn through PVC Casing & Caping of suitable size (as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including steel sunken box/Gang Box of suitable size and shape with modular cover plate ISI marked complete all as specified and directed by Engr-in-Charge. |
| 52 | (a) One light/fan point controlled by one 5 Amps one way switch |
| 53 | (b) One 3 pin socket outlet 5 Amps on independent board |
| 54 | (c) One 3 pin socket outlet 5 Amps on same board |
| 55 | M&L point wiring for power point with 4 sqmm (nominal area) copper conductor FRLS-H cable ( multi-stranded) PVC insulated and unsheathed cable conductor 1100 Volts drawn through PVC Casing & Caping of suitable size(as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 2.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including steel sunken box/Gang Box of suitable size and shape with modular cover plate ISI marked complete all as specified and directed by Engr-in-Charge. |
| 56 | S & F Switch piano flush button single pole one way 5 Amps, 240 Volts complete all as specfied and directed by Engr-in-Charge. |
| 57 | S&F Socket outlet 2 in 1, 3 pin, 6A (multipurpose) suitable for 3 pin / 5 pin plug complete all as specified and directed by Engir-in-Chage. |
| 58 | S&F switch socket combination 3 pin, 5 Amps, 2 in 1 flush type (multipurpose) suitable for 2 pin / 3 pin plug complete all as specified and directed by Engir-in-Chage. |
| 59 | S&F switch socket combination 2 in 1, 3 pin, 5/15 Amps, flush type (multipurpose). Complete all as specified and directed by Engr-in-Charge. |
| 60 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge. |
| 61 | Supply and fixing Rechargeable LED Bulb 9 W ,220 V, white color all as specified and as directed. |
| 62 | Supply and fixing Stellar Bright LED T-Bulb 12 W ,220 V, white color all as specified and as directed. |
| 63 | S&F surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver tube light fitting 20W, 4 ft long, 220 Volts , and connecting to ceiling rose with two core twisted flexible copper cable of suitable size complete all as specified and directed. |
| 64 | S&F Ceiling rose surface backelite ISI marked with 3 terminal including connecting and testing complete all as specified and directed. |
| 65 | S&F MCB DB sheet enclosure,Double door type, single pole and neutral 240V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed. |
| 66 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and currentcarrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed. |
| 67 | Supply and fixing MCB SPN 240V, 10KA 'C' curve (40-63) Amp current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed. |
| 68 | Supply & Fixing LED light fitting 1X10W bulkhead luminaires including LED light and driver holder connecting up with two core flexible copper conductor cable of suitable size all as specified and directed. |
| 69 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed. |
| 70 | Deduct Schedule of Credit of as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender