Tender For Construction Work Of 220 Kv Gss, Rvpn, Salarpur, On Labor Rate Contract. Part -B (Non Bsr Item) Under This Office Tn-547/2026-27
Tender Value
55.19 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
1 days left
EMD
1.10 Lakhs
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Alwar → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Work Of 220 Kv Gss, Rvpn, Salarpur, On Labor Rate Contract. Part -B (Non Bsr Item) Under This Office Tn-547/2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Filtration of Transformer Oil of 220/132 KV, 160 MVA and two numbers 132/33 KV, 40/50 MVA Transformer at 220 KV GSS, Salarpur, with providing high vacuum filtration machine (10KL) and Oil testing kit having 100 KV Capacity, along with facility of 1 Tor Vacuum pressure. |
| 2 | Providing 20000/25000 Litter capacity transformer Oil Tank on per day rate basis Including Loading, Unloading and transportation charges (filtration of Oil transformer of Machine) |
| 3 | Line differential cum distance relay with required interface to connect digital protection coupler and all other accessories/items for retrofitting at PG Bhiwadi and PG Neemrana end. |
| 4 | Laying of Earth mesh with 25 mm /28 mm dia M.S. rod at a depth of 0.80 mtr. From top level of foundation, including excavation of trench of required depth and back filling of the same, transportation of M.S. rod of from site store to locations, welding of M.S. Rod to M.S Rod along the length at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints for the type of soil prevalent at 0.80 mtr. Below top level of foundation (M.S. Rod of above sizes and M.S. flat as required shall be made available by RVPN.(a) In case electricity is made available by RVPN without charges. (i) Any soil, Soft rock other than hard rock. |
| 5 | Laying of earthing risers of 50x6mm/50x10mm/50x12mm size M.S. flat at a depth of 0.80 mtrs. From top level of foundation, including excavation of trench of required depth and back filling of the same, transportation of m.s. flat from site store to locations, preparation of risers bending as per requirement (after heating if necessary) fixing on and welding/bolting to equipment/ structure and peaks of structures, laying in the trench, welding to the earth mesh of M.S. rod as per drawing including welding of extra length of M.S. Flat if required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surfaces of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 Mtrs. below top level of foundations. (M.S. Rod of above sizes and M.S. flat as required shall be made available by RVPN ) (a) In case electricity is made available by RVPN without charges. (i) Any soil, Soft rock other than hard rock. |
| 6 | Placing /driving of earth electrodes of 28mm dia MS Rod of length 3.30 Mtrs. Approx to a depth of 3.80 Mtrs. From the top level of the foundations including excavation of pit as required and back filling of the same, transportation of MS Rod from site stores to locations. Cutting of MS Rod to desired length, preparation of one end as spike if necessary, welding of earth electrodes to earth mesh of MS Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on the all welded joints for the type of soil prevalent at 3.80 Mtrs. below top level of foundation (MS Rod of above sizes and MS Flat as required shall be made available by RVPN)(a) In case electricity is made available by RVPN without charges. (i) Any soil, Soft rock other than hard rock. |
| 7 | ERECTION OF SUB STATION STEEL STRUCTURES, Columns, beams, lighting, mast and equipment structures (excluding Circuit Breakers) of all types including transportation of structure members, nuts & Bolts, washers etc. from site stores to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required, leveling and preparing for grouting as required, but excluding grouting, erection after grouting and lightening and punching of nuts & bolts. (Maximum height of structures up to 20 Mtrs.) |
| 8 | Bus bar work :-(A) Stringing of 220,132 KV/33KV bus bar of ACSR conductor including transportation of conductor disc Insulator & tension H/W from site store to location , laying & cutting required length of conductor cleaning and assembly of disc insulator as required along with filling of bolted type or compression type tension H/W as made available (compression machine shall be provided by RVPN on rent free basis) making up at one end string of conductor between the beams with the specified sag & tension also equalizing sag and tension also equalizing sag and fitting spacers & spacers T clamps or twin conductor for three phases of conductor in each bus section. 1. Any Single Conductor |
| 9 | Bus bar work :-(A) Stringing of 220,132 KV/33KV bus bar of ACSR conductor including transportation of conductor disc Insulator & tension H/W from site store to location , laying & cutting required length of conductor cleaning and assembly of disc insulator as required along with filling of bolted type or compression type tension H/W as made available (compression machine shall be provided by RVPN on rent free basis) making up at one end string of conductor between the beams with the specified sag & tension also equalizing sag and tension also equalizing sag and fitting spacers & spacers T clamps or twin conductor for three phases of conductor in each bus section. 2. Any Double Conductor |
| 10 | Jumpering of ACSR Conductor (03 Nos. Y type) between bus to equipment or between equipment to equipment or between bus to bus including transportation of conductor from site store to locations, cleaning and assembly of Disc Insulators as required along with fitting of suspension H/W & erection as required cutting required length of conductor, making connection, fixing of spacers & spacers T clamps as required tightening of clamps and connectors , dressing etc. for three phases (per jumper basis) 1 Any Conductor |
| 11 | STRINGING of Earth wire (Size 7/3.15mm or 7/4 mm) including Transportation of Earth wire, Tension Hardware etc. from site stores to locations, laying and cutting required length of earth wire, fitting of bolted type or compression type hardware as made available (Compression machine shall be provided by RVPN on rent free basis) making up at one end stringing of earth wire between structure peaks with specified sag and tension jumpering and connecting with earth bonds for single earth wire |
| 12 | ERECTION OF SUB STATION EQUIPMENTS :- erection of 33/0.4 s/s transformer up to 500 KVA on existing masonry platform including transportation of transformer & accessories from site store to location. Erection of horn gap fuse set jumpering from isolator to horn gap to transformer |
| 13 | Erection of Current transformer / Capacitive voltage transformer / Potential Transformer/Series Eactors/Residual Voltage Transformer/Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc. complete in all respects. i) 220 KV CT/PT/CVT |
| 14 | Erection of Current transformer / Capacitive voltage transformer / Potential Transformer/Series Eactors/Residual Voltage Transformer/Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc. complete in all respects. i) 132 KV CT/PT/CVT |
| 15 | Erection of Current transformer / Capacitive voltage transformer / Potential Transformer/Series Eactors/Residual Voltage Transformer/Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc. complete in all respects. i) 33 KV CT/PT/CVT |
| 16 | Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor , clamps & connectors, surge counter etc. from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc., complete in all respect. i) 220 KV |
| 17 | Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor , clamps & connectors, surge counter etc. from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc., complete in all respect. i) 132 KV |
| 18 | Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor , clamps & connectors, surge counter etc. from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc., complete in all respect. i) 33 KV |
| 19 | Erection of Isolators on already erected steel structure including transportation of base frame, P.I.’s contacts, mechanism box, clamps & connectors etc. from the site store to locations, minor fabrication as required and fixing of terminal connectors etc. adjustment/ alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering, Including erection of PI i) 220 KV a) Without Earth Blade |
| 20 | Erection of Isolators on already erected steel structure including transportation of base frame, P.I.’s contacts, mechanism box, clamps & connectors etc. from the site store to locations, minor fabrication as required and fixing of terminal connectors etc. adjustment/ alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering, Including erection of PI i) 220 KV a) with Single Earth Blade |
| 21 | Erection of Isolators on already erected steel structure including transportation of base frame, P.I.’s contacts, mechanism box, clamps & connectors etc. from the site store to locations, minor fabrication as required and fixing of terminal connectors etc. adjustment/ alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering, Including erection of PI i) 220 KV c) Tandom |
| 22 | Erection of Isolators on already erected steel structure including transportation of base frame, P.I.’s contacts, mechanism box, clamps & connectors etc. from the site store to locations, minor fabrication as required and fixing of terminal connectors etc. adjustment/ alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering, Including erection of PI i)132 KV a) Without earth blade |
| 23 | Erection of Isolators on already erected steel structure including transportation of base frame, P.I.’s contacts, mechanism box, clamps & connectors etc. from the site store to locations, minor fabrication as required and fixing of terminal connectors etc. adjustment/ alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering, Including erection of PI i)132 KV b) With single earth blade |
| 24 | Erection of Isolators on already erected steel structure including transportation of base frame, P.I.’s contacts, mechanism box, clamps & connectors etc. from the site store to locations, minor fabrication as required and fixing of terminal connectors etc. adjustment/ alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering, Including erection of PI i)33 KV a) Without earth blade |
| 25 | Erection of Isolators on already erected steel structure including transportation of base frame, P.I.’s contacts, mechanism box, clamps & connectors etc. from the site store to locations, minor fabrication as required and fixing of terminal connectors etc. adjustment/ alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering, Including erection of PI i)33 KV b) With single earth blade |
| 26 | Erection of Wave trap on already erected structure beam, including transportation of wave trap, disc insulators, hardware, clamps, and connectors, etc. from site store to locations, cleaning & assembly of disc insulators along with fitting of suspension arrangement and erection , fixing of terminal connectors etc . i)220 KV |
| 27 | Erection of 220KV ,132 kV Circuit Breaker, including transportation of equipment, structure members, nuts and bolts, clamps and connectors, accessories etc. from site store to location, assembly of support sturcture, their placving on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly/ placing of support columns/ poles, mechanism box/ control cubicle, and other accessories as per manufactures drawings, fitting of Safes pipeline as required, electrical wiring from pole to cubicle, fixing of terminal connectors as required , but excluding commissioning of CB, for alltypes of operating mechanism, as required. i)220 KV |
| 28 | Erection of 220KV ,132 kV Circuit Breaker, including transportation of equipment, structure members, nuts and bolts, clamps and connectors, accessories etc. from site store to location, assembly of support sturcture, their placving on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly/ placing of support columns/ poles, mechanism box/ control cubicle, and other accessories as per manufactures drawings, fitting of Safes pipeline as required, electrical wiring from pole to cubicle, fixing of terminal connectors as required , but excluding commissioning of CB, for alltypes of operating mechanism, as required. i)132 KV |
| 29 | Erection of 33 or 11 kV Circuit Breaker, including transportation of equipment, structure members, nuts and bolts, clamps and connectors, accessories etc. from site store to location, assembly of support structure, their placing on foundation, leveling and preparing for grouting as required, but excluding grouting, assembly/ placing of support columns/ poles, mechanism box/ control cubicle, and other accessories as per manufacturer drawings, fitting of terminal connectors as required , but excluding commissioning of CB. i) 33 or 11 kV CB (outdoor Type) VCB/ SF6 |
| 30 | Erection of Post Insulator on already erected structures including transportation of PI’s nuts & bolts, clamps & connectors etc. from site store to locations, fabrication of base frame & assembly if required, fixing of clamps, etc. 1) 220 KV |
| 31 | Erection of Post Insulator on already erected structures including transportation of PI’s nuts & bolts, clamps & connectors etc. from site store to locations, fabrication of base frame & assembly if required, fixing of clamps, etc. 1) 132 KV |
| 32 | Erection of Post Insulator on already erected structures including transportation of PI’s nuts & bolts, clamps & connectors etc. from site store to locations, fabrication of base frame & assembly if required, fixing of clamps, etc. 1) 33 KV |
| 33 | Erection of 220 kV Class EHV Transformer (Gas filled Tank already placed on foundation with wheels) including transportation of accessories from site store to location, erection of HV, IV, LV & Neutral Bushings, main & OLTC conservators, Radiators, Equalizing Pipeline, Marshaling kiosks etc. as per manufacturers drawing, preparation of oil, oil filling, de-hydration of transformer (Filter Machine, Oil tank & Operating staff shall be provided by RVPN), electrical wiring from individual equipments e.g. Buchholz Relay, MOLG, OSR, Fans & Pumps, Bushing CTs etc. to Marshaling Kiosk, etc. but excluding Testing and Commissioning of Transformer. a) If Electricity is available & arranged by RVPN without charges. |
| 34 | Erection of 132 kV Class EHV Transformer (Tank already placed on foundation with wheels) including transportation of accessories from site store to location, erection of HV, IV, LV & Neutral Bushings, main & OLTC conservators, Radiators, Equalizing Pipeline, Marshaling kiosks etc. as per manufacturers drawing, preparation of oil, oil filling, de-hydration of transformer (Filter Machine, Oil tank & Operating staff shall be provided by RVPN), electrical wiring from individual equipments e.g. Buchholz Relay, MOLG, OSR etc. to Marshaling Kiosk, etc. but excluding Testing and Commissioning of Transformer. a) Electricity is arranged by RVPN i) Transformer Received Oil Filled |
| 35 | Erection of Control & Relay Panels complete in all respects including transportation from site store to control room, placing on foundation/ cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side/ top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay as required. i) Duplex Panel |
| 36 | Erection of Control & Relay Panels complete in all respects including transportation from site store to control room, placing on foundation/ cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side/ top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay as required. ii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc. |
| 37 | Erection of Control & Relay Panels complete in all respects including transportation from site store to control room, placing on foundation/ cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side/ top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay as required. iii) LT Panel |
| 38 | Erection of marshalling kiosk/ line matching unit (LMU)/ line matching & distribution unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation/cable trench as per layout, preparing for grouting on foundation bolts but excluding grouting etc. 1) 220 KV or 132 KV Marshaling box |
| 39 | Erection of marshalling kiosk/ line matching unit (LMU)/ line matching & distribution unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation/cable trench as per layout, preparing for grouting on foundation bolts but excluding grouting etc. 2) 33 kV Marshaling Kiosks |
| 40 | BATTERY CHARGERErection of Battery Charger complete in all respects including transportation from site store to location, placing on foundation / cable trench as per layout etc. i) 220 V Volt DC,400 AH |
| 41 | BATTERY CHARGERErection of Battery Charger complete in all respects including transportation from site store to location, placing on foundation / cable trench as per layout etc. ii)48V Volt DC 600/400/200 AH |
| 42 | BATTERY SET:- assembly erection and commissioning of Lead acid Battery set, including transportation of cells, battery stand, Nuts &Bolts from site stores to Battery room, assembly of stand, placing of cell on stand, making their interconnection initial charging & discharging and final charging as per procedure recommended by Battery set Manufacturer: a) If electricity is available & arranged by RVPN without charges. i) 220 V Volt DC,400 AH |
| 43 | BATTERY SET:- assembly erection and commissioning of Lead acid Battery set, including transportation of cells, battery stand, Nuts &Bolts from site stores to Battery room, assembly of stand, placing of cell on stand, making their interconnection initial charging & discharging and final charging as per procedure recommended by Battery set Manufacturer: a) If electricity is available & arranged by RVPN without charges. ii)48V Volt DC 600/400/200 AH |
| 44 | LAYING AND TERMINATION OF CABLES. Control Cablesi)Laying of PVC insulated unarmored/ armored control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable trenches, cutting to required length, placing them on cable racks/ cable trays/ cable batten and dressing, including removing and re-fixing trench covers as required, making necessary connections testing, cable marking on both terminating ends, etc. as required for all size from 2c X2.5 sq.mm to 20c X2.5 sq mm , 4cX 4 or 6 sq mm 1) Unarmored control cable |
| 45 | LAYING AND TERMINATION OF CABLES. Control Cables :-Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS:12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates, etc. as required and including cost of cable glands, for each cable gland of size. a)19 mm unarmored control cable |
| 46 | LAYING AND TERMINATION OF CABLES. Control Cables :-Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS:12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates, etc. as required and including cost of cable glands, for each cable gland of size. b)25 mm unarmored control cable |
| 47 | LAYING AND TERMINATION OF CABLES. Control Cables :-Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS:12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates, etc. as required and including cost of cable glands, for each cable gland of size. c)32 mm unarmored control cable |
| 48 | Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell’s or equivalent make as approved by Engineer-in- Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc., as required, including cost of terminal ends for all wires for each cable at both ends for cable for the following size. a)2.5 sq.mm.for any number of core |
| 49 | Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell’s or equivalent make as approved by Engineer-in- Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc., as required, including cost of terminal ends for all wires for each cable at both ends for cable for the following size. b) 4 sq.mm.for any number of core |
| 50 | Laying of P.V.C. insulated unarmored/ armored L.T.cables(i)Laying of P.V.C. insulated unarmored/ armored L.T.cables of 1.1 kV grade with aluminum conductor as per IS: 1255 in ground / cable trench/ wall/ surface including transportation of cable drums from site store to locations and excavation of 30 cm. X 75ize cable trenches, providing 25 mm. thick under layer of sand & 2nd class brick covering & refilling earth in remaining portion, fixing as per approved spacing by means of M.S.U. - clamps, etc as per specifications as required including necessary connections & testing etc. as required for following size of cables. a) 3 ½ Core 300 MM.² Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 06, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayJul 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender