Public Administrative Department Local Bodies Closing in 10 days TDR #56318435

Tender For Developement Of Krtrim Lake Under Shyama Prasad Mukherjee Scheme In Municipal Council Phalodi Area.

Issued by Local Bodies · Jodhpur, Rajasthan
Tender Value
2.58 Crore
Estimated cost
Bid Submission
28 Jul 2026
10 days left
EMD
5.16 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Developement Of Krtrim Lake Under Shyama Prasad Mukherjee Scheme In Municipal Council Phalodi Area.

BOQ

Name of Work:- Developement of Krtrim Lake under Shyama Prasad Mukherjee scheme in Municipal Council Phalodi area.
Sl. No. Item Description
1Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to a lead of 50 metres from road boundary including removal and disposal of top organic soil not exceeding 150 mm in thickness as directed by Engineer. In area of light jungle
2Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m.
3Fine dressing the ground. sqm 3.45
4Dismantling and re - erection of P.C.C./R.C.C. pole as per REC manual no 15/1979 conforming to IS: 2905/1966 as per requirementof sec3 in alignment, including excavation of pit and back filling with stone aggregate/boulders and soil in 0.45m consolidating each deposited layer of 0.45m by ramming and watering etc complete in all respect 9.0 Mtr (400 Kg) long as per Discom specification
5Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m.
6Carriage of Materials by mechanical transport including loading, unloading and stacking : Earth lead upto 1 km
7Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m
8Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size).
9Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:3 (1 cement : 3 coarse sand)
10Extra for random rubble masonry with hard stone in superstructure above plinth level and upto two stories
11Extra for random rubble masonry with hard stone in : Square or rectangular pillars
12Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in: Cement mortar 1 : 4 (1 cement : 4 coarse sand)
13Half brick masonry with FPS bricks of class desination 75 in Superstructure , above plinth level upto two stories. Cement mortar 1 : 4 (1 cement : 4 coarse sand) Extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry .
14Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
15Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.
16Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform.
17Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level :1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
18Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
19Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement:M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) -As per design mix)
20Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
21Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 1:3 (1 cement : 4 fine/ coarse sand)
22Providing, laying and compacting plain/ reinforced cement concrete of specified grade in foundation/ levelling course/ pile cap using concrete mixer and vibrater complete including cost of form work, as per drawing and technical specifications and as per clause 1100, 1500,1700,2100 of MoRT&H specification including all scaffolding material, labour, machinery. PCC Grade M -15
23Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. as per manufacturer's specification. Two or more coats on new work.
24Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibr cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately For the purpose of measurement the entire treated surface will be measured.
25Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
26Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces.
27Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel rimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
28Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
29Random rubble dry stone Kharanja (soling) under floor.
30Providing and fixing Tubular Steel Railing on Precast RCC posts, 1.2 m high above ground level Providing, fencing and erecting 50 mm dia G.I pipe railing in 3 rows on precast M20 grade RCC verticaln posts1.8 metres high (1.2 m above GL) with 3 holes 50 mm dia for pipe, fixed 2 metres centre to, complete as per approved drawing including all material, labour.
31Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with finesand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge.The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and brakingload etc. as per BS 6717:2001, Grey cement. 60mm thick
32Painting new letters and figures of specified size, of any shade with first quality synthetic enamel paint, black or any other approved colour to give an even shade as per clause 801 of MoRT&H Specification including all material, labour. Hindi (Matras, Commas and the like not to be measured and paid for. Half letters shall be counted as half).
33English and Roman (Hyphens, commas and the like not to bemeasured and paid for)
34Providing and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron posts 40 mm x 40 mm x 6 mm placed every 3 metres center to center founded in M15 grade cement oncrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 807 of MoRTH pecification & type \\"A\\" as per IS : 2781978 size designation 5 (line wire 2.24, point wire 2.00mm mass 97106 g/m) including all material, labour.
35Providing and fixing precast cement concrete M-20 grade (Usingmechanical Concrete Mixer) kerb stone top and bottom width 115 and 165 mm respectively, 250 mm high on 150 mm thick PCC M-10 grade foundation as per design, including fixing at site as per clause 408 of oRT&H Specification including all material, abour, machinery, lighting, guarding and maintenance of diversion.
36Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc.laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement :2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Green / Black Upto to 1500 Cm2 Tiles
37Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge togive high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work
38Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc.complete
39Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
40Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP3 class (with s/s ends) IS: 458 - 1988 (amended up to date) marked and pipes from 300 mm upto 2000 mm manufactured through vertical / vibrated casting process all levels with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as directed by Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. 1000 mm internal diameter
41Providing & Fixing in position, MS fabrication work using angles, sqr tubes, c channels etc for various partition frame as per Design & Instructions & Complete in all aspects . including all materials labour, finishing etc complete
42Making Mehrab's, Arches, pillars, highly decorative creepers, flower of small sizes etc.in lime Surkhi plaster (1:2) as per B248oldtraditional practices (Arches, Mehrab's) in three coats for base course and subsequent course and Loi tamping, beating till the shrinkage cracks are disappear than making ornamental flowering/design etc. The work is to done with all leads and lifts as per work of restoration nature as per Jaipur practice.
43Making Kangura on top of the wall as per Jaipur traditional practice with tile brick bats/stones in grinded Lime Surkhi mortar 1:2 thickness of kangoora 15cm & height 45cm, finishing with lime Surkhi mortar 1:2 complete in all respect up to 10.00 meter from ground level including all scaffolding, lead & lift.
44Providing new /restoration of decorative sandstone columns as per the original details found on site of size around 2.1 to 2.5 metres inheight & (square/ rectangular upto 200 mm x 400mm ). The damaged portions of the original column to be carefully dismantled without damaging the adjacent areas, & replacing the same with new detail of the same size & design. Sample of the terra cotta column to be shown to the Engineer in-charge for approvals beforeprocuring & fixing the same on site. Item to include all necessary anchoring details, scaffolding if required etc. complete. Mode ofMeasurement: Item to be paid each restored/new column for using plain
45Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for separately) : Red sand stone - Exposed face fine dressed with rough backing. 30 mm thick.
46S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 40 mm dia
47Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections,testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Single pole MCB 6 A to 32 A rating
4850A to 63 A rating
49Providing & Fixing of IK09 rating recessed/surface mounting heavy duty Vertical type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3 with provision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing , phosphatised ,powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate , testing etc. as required complete in all respect.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & Allas per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 4 Way(8+12)
5012 Way(8+36)
51Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured copper cable of 1.1 KV grade as per PWDspecification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity >99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 4sqmm, 3core arm
5210 sqmm, 4 core arm
53Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% ,THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . High Power LED Flood Light 14800 Lm
54Supply and erection of M.S. Galvanized Octagonal pole ( as perBSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ forMS plate for base flange )of following length and dimension as pertable P-01 with base plate on the cement concrete foundation of M20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.) 9 Mtr.
55Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Single arm overhang
56Providing & Fixing of IP-65 Protected LED aviation obstruction light luminaire comprising of die cast aluminium alloy housingwith olycarbonate enclosure having more than 200 No's Low Power LED's having minimum power consumption 15 watts complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . aviation obstruction LED light luminaire Min. 15 Watts
57Providing & Fixing of ISO certified company made IK10 IP65 protected Top/Bottom mounted LED Post top Light system. Fixture made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. driver current <1000mA shown in LM79 report. Fixture must be in compliance with BIS Standards and T.C . Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of roduct/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR 45 W LED Post Top Fixture
58Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . drivercurrent <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . LED Street Light fixture 120 Watt
59Providing and fixing of fuse box size 250(H) x 200(W) x 150(D) mm fabricated of 1.6mm MS sheet with hinged cover, dust and vermin proof, rubber gasket, locking arrangement, duly holded with 2 nos pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with anticorrosive treatment, finished with two coat of approved enamel paint. The box shall be provided with 2 / 4 nos copper bus bar 125 x 20 x 3 mm with brass screws suitable supports,earth terminal, inter connection, knock outs for 20 / 25 mm cable gland, 1 no. 16 Amp kitkat fuse complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
60Providing & Fixing of IP - 65 protected impact resistantpolycarbonate / Polysterene enclosures with knock out for cableentry/out including fixing with nut, bolt, fatner etc as requiredcomplete in all respect of following sizes. All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR .300 x 450 x 132 mm
61S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of > 100 Lumen perwatt.Bidder shall have in house R&D Laboratory which is recognised by ministry of Science & Technology department, Govt. OfIndia/ NABL. Bidder shall have inhouse pole & luminaire manufacturing facility. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab. Guarantee for total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. ompact Solar LED Street Light - 30 W LED Street Light fixture 30 Watt
62Provide and fixing of LED POST TOP fixture made form Die castaluminum graphite grey powder coated finished housing.Polycarbonate opal diffuser. Low power Warm White (WW) LEDsconnected in series and parallel combination with better Heatdissipation arrangement. Highly efficient constant current electronicdriver having operating voltage range from 140- 280 Volt AC; provided with high voltage, open and short circuit protection. Suitable for 60mm OD pipe entry with fixing bolts. Degree of protection IP65 LED Make – Nichia/Philips/Osram/Cree or Equivalent LED color temperature range form 3000-5700°K ±300°K. Voltage surge protection 5KV. the luminaire should bear 5 KV surge protection,PF >=0.9(HPF) and total harmonic distortion of THD(I) <10% voltage range of 140-280V. Manufacturer to provide certificate of LM 80 LM 79 form source manufacturer and should have in house adequate testing facilities ( approved by Govt. of India ministry of science and technology/NABL) . Approved Luminaire Make: Philips, Bajaj, Keselec. 30 W LED Post Top Fixture
63Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as perpre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Short point (up to 3 mtr.)
64Medium point (up to 6 mtr)
65Long point (up to 10 mtr)
66Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additionaltechnical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . On Board
67Short point (up to 3 mtr.)
68Medium point (up to 6 mtr)
69Long point (up to 10 mtr)
70S &F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III )vergin material PVC conduit as per PWD specification for electricalWorks along with its accessories (IS: 3419 ) as required in recessincluding cutting the wall, covering conduit and making good thesame as required. All relative and latest acceptance tests reports byany NABL accredited lab for the conduit shall be submitted beforeexecution & All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . 25 MMDIA
71Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
72Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling roses as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
73Providing & Fixing of ISI marked (IS:1258) 6 amp batten/angle lamp holder as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
74Providing & Fixing of following size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 5 Module
756 Module
768 Module
77Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 4-5 Module
786-8 Module
79Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 10 A one way switch
8016 A one way switch
81Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 6 A 3 pin shuttered socket
8216 A 6 pin shuttered socket
83Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 5 step fan regulator 120 watt 2 Module
84P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
85Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 380 mm sweep(900/1400 RPM)
86Mesh earthing as per IS:3043 with copper earth strip of size 20 mm x 3 mm to form a mesh of size 3000 mm x 1000 mm in horizontal formation to create equal sections of 500 mm x 500 mm by means of 10 mm brass bolts, & nuts with spring washer, embodying 1 mtr. Below the ground level, refilling the pit by alternative layers of charcoal & salt up to 500 mm with 20 mm dia, 20mm GI 'B' class watering pipe and 12 mm G I 'B' class pipe for the earth wire including all accessories like nuts, bolts, wire mesh funnel and brick masonary finished chamber covered with hinged CI cover and locking arrangement of size 300 mm x 300 mm complete in all respect.
87Rectangular LED Marker Light
88P & F of IP65 IK10 rated LED bulk head type light fixture made from CRCA sheet steel housing suitable for mounting LED tube system (integral driver), Power consumption of 10-15W , 500-600 lumens system lumen efficiency 70 lm/ watt output suitable for1x100 W GLS/9W CFL bulk head fixtures, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000° K,4000° K and 6000° K. Fixture shall be incompliance with CE & KEMA standards. LED Bulk head luminaire 9/10W
89Providing & Fixing of IK07 IP-66 protected high power LED floodlight system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Fixture shall be IS 10322 Compliant. All as per pre approved by Engineer in-charge. High Power LED Flood Light 30W
90P & F of IP68, IK10 protected LED Buried marker light /Step LightFixture. Fixture made of powder coated die cast aluminium withToughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral SMPS based electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency >85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards. Burial Light - 5W
91P & F of IP68, IK10 protected LED Buried marker light / Step Light Fixture. Fixture made of powder coated die cast alluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral SMPS based electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency > 85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards.
92Supply, Installation, Testing and Commissioning of Spike Light with 10 Degree Beam Deflection and 3000 K CCT. 12 Watt
93Supply, installation, testin and commissioning of 18W LED recess mounted LED ceiling light with die cast aluminium housing for thermal management. High efficiency diffuser for glare free uniform light distribution. • Integrated with COB light LED. • High PF >0.9 constant current LED driver with 2.5KV built in surge and thermal protection. Cable entries for through-wiring of mains supply cable. Suitable for operation on 240V, 50Hz single phase ac supply.
94Supply, installation, testing and commissioning of 18 watt LED 3000K, 4000K 240Vac CRI >80 MacAdam step 3 Input power : 18W Dimension Ø100 x 150mm Beam angle : 15° / 25° / 40° Electronic driver ON/OFF CE and BIS LUMINAIRE TYPE Ceiling Mounted Down Light. IP rating IP65 MATERIAL CHARACTERISTICS Extruded aluminium pipe (grade 6063 with test certificate) Ø100 x 2.5mm thickness & cast aluminium plate for surface mounting on ceiling (grade ADC12 with test certificate). SS fasteners. Silicone gasket. Mechanical resistance IK07. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. LIGHTING PERFORMANCE Hybrid optics with lens & reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.95, THD <10%, Surge protection 3KV.
95Providing and Fixing Panel Light for Celling 595x595 (48 Watt)complete as per standard spesification, as per Direction of Engineerin-charge.
96Decorative haritage pole in 4 Meter height. Pole upper section oflength 3mtr is of dia 76mm and 1 meter bottom section of dia114mm with decorative casting with base plate as per drawing.Provision for inside termination box with 4way connector & 1nos 6AMPS MCB for local isolation with cover.Complete in all aspectswith foundation bolts.
97Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non yellowish diffuser for uniform light distribution. High efficiency with2.5 KV internal/external surge protection BIS certified isolated driverhaving efficiency > 85% , with Short & Open circuit protection and incompliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. 36W LED light fixture 2'x2' with acrylic / prismatic front cover.
98Providing & Fixing of IP66 COLD White Narrow Sharp Focused Angle LED Spot Light 1w to 5w for sutaible arrangement complete as per standard spesification, as per Direction of Engineer in-charge.
99Trenching in specified soil upto a depth of 60 cm. including removal and stacking of serviceable materials and then disposal by spreading and neatly leveling within a lead of 50 metres and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and farm-yard manure before and after flooding with water (excluding cost of imported earth and sludge or farm-yard manure).
100Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking
101Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction
102Filling mixture of earth and sludge farm-yard manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or farm yard manure and labour for mixing not included in this rate).
103Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart.
104Supplying, erecting and fixing in position specified precast RCC bench made of RCC grade M-30 consisting of 2 Nos. “L” shaped base support of thickness 100 mm back height 1000mm, front height 450 mm, base width 420mm and 5 Nos. RCC planks of size of 1500x100 x 50 mm and 1 Nos RCC planks of 150x200x50mm including joining all parts with galvanised nuts and bolts of suitable size. All bolts to be sealed after assembly with nice finish and appearance and level complete in all respect as per direction of engineer in charge. Every bench should have a manufacture‘s logo of appropriate size Engraved at suitable place.
105Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 20mm nominal outer dia pipes
10640mm nominal outer dia pipes
10762.5mm nominal outer dia pipes
108Supply and planting following in poly bags / arthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. Wedelia trilobata ( SunFlower Family)
109Alternathera green (Parrot Leaf)
110Rhoeo spathacea 'Compacta‘ ( Oyster, Boat Lily)
111Golden duranta
112Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. Ficus panda
113Tabernaemontana variegated ( Chandni)
114Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 600 mm min. height hurbs at site in 0.45 m dia holes, 0.45 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. Rhaphis excelsa with 3-4 suckers ( Lady Palm)
115Furcaria with 10-12 leaves ( cactus)
116Phonenix sylvertris ( Date Palm)
117Supply and planting following species best quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. Plumeria alba ( Champa)
118Neem(Azadirachta indica)
119Erythrina variegata (Lantern Tree)
120Quis quallis indica ( Madhu Malti)
121Table palm
122Acacia senegal
123Moringa concanensis
124Tinospora cordiflia
125Supply and planting following species best quality container grown healthy trees of 3 mt. min. height, well established & free from disease at site in 1.20 m dia holes, 1.20 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. Plumeria alba ( Champa) 3 M height minimum
126Gulmohar(Delonix regia)
127Neem(Azadirachta indica)
128Bauhinia blakeana (Arckid)
129Erythrina variegata (Lantern Tree)
130Yucca Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56318435
AUTHORITY Local Bodies
TENDER VALUE 2.58 Crore
LAST DATE 28-07-2026
Authority
Authority Name Department Of Local Bodies
Work Description Tender for Developement Of Krtrim Lake Under Shyama Prasad Mukherjee Scheme In Municipal Council Phalodi Area.
Basic Detail
Tender No NPP/2026-27/2257
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 04 Jul 2026
Submission Date 28 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 2.58 Crore
Tender Fee 1000
EMD 5.16 Lakhs
Exemption Available
Document List
4b00ecab-ab96-4b33-b7f5-40c51497fe97.html
BIDDocumentsnew.pdf
BOQ_1019521.xls
FinalTechnicalBidLAKE.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

4b00ecab-ab96-4b33-b7f5-40c51497fe97.html

pdf

BIDDocumentsnew.pdf

xls

BOQ_1019521.xls

pdf

FinalTechnicalBidLAKE.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders