Housing Urban and Rular Development Government Departments Closing in 11 days TDR #56317065

Tender for Tender for Establishment Work Of One In Nyalaya Kachho And Vyam Kachho Of Family Court Of District Court, Maharajganj.

Issued by Government Departments · Maharajganj, Uttar Pradesh
Tender Value
16.92 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
11 days left
EMD
1.70 Lakhs
Bank guarantee accepted
Document Fee
854
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Maharajganj → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Establishment Work Of One In Nyalaya Kachho And Vyam Kachho Of Family Court Of District Court, Maharajganj.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Jul-2026 corrigendum Date 28-Jul-2026

BOQ

Name of Work:- tuin U;k;ky; egjktxat ds QSfeyh dksVZ ds U;k;ky; d{kksa ,oa foJke d{kksa esa ,0lh0 LFkkiuk dk dk;ZA
Sl. No. Item Description
1Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering. All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only. Incoming: Incomer- 100 Amp- 1 Nos MCCB Outgoing- , 63 Amp - 2 Nos MCCB
2S&F of 100 Amp. 4 Pole Change Over Switch on 50mm x 50mm x 6mm angle iron frame, Including the cost of labour, T&P, Painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 800 Amp. B6:B154 Pole on 50mm x 50mm x 6mm angle iron frame. AR
3Supplying and fixing following way, horizontal typethree pole and neutral, sheet steel, MCB distributionboard, 415 V, on surface/ recess, complete withtinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator).2.4.1 4 way (4 + 12), Double door DSR 2.4.1
4Wiring for circuit/ submain wiring alongwith earth wire with the 2X 6sq.mm+1X6sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. DSR 1.14.6
5Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire DSR 1.14.10
6Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole DSR 2.10.3
7Supplying and fixing of 63 Amp. 4 Pole MCCB complete in all respect. AR
8Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 Amodular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.Less Cost Of Single Pole MCB DSR 1.57 (2.10.1)
9Supply and laying of Al. Conductor PVC Insulated armoured served sheathod cables 1100V grade at a depth of 400mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall ne fixed on M.S Clamps etc of suitable size or as directed by Engineer in Charge complete in all respect inculuding excavation and refilling. The armouning of the cable shall be properly connected with the earth conductor by clamps etc. (i)- 70 sq. mm 3-1/2 Core DSR 20.1.13
10Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. DSR 5.2
11Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15
12Providing and fixing 6 SWG dia G.I. wire on surfaceor in recess for loop earthing as required. DSR 5.16
13Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. DSR 2.21
14Providing and laying of 1800 mm X 900mm X 12 mm thick chequered matting of tested quality. TS
15Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 52 0C. Min 5 year Original Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating. a) Capacity 1.5 Ton
16same as above SITC of Split AC . b) Capacity 2.0 Ton
17SITC of 4 KVA Voltage Stablizer for Air Conditioner Upto 1.5TR (Range 130 - 300 Volt) Copper Winding. QR
18SITC of 5 KVA Voltage Stablizer for Air Conditioner Upto 2.0TR (Range 130 - 300 Volt) Copper Winding. QR
19Supllying and fixing of 2.5 sqmm, 3 core Round cable for Connection of power point to to Stablizer to indoor unit of AC .QR
20Supllying and fixing of 2.5sqmm, 4 core Connecting Round cable for indoor to Outdoor of AC. QR
21Supllying and fixing of suction/Discharge Copper pipe line in split A.C unit 2.0 ton capacity including cost of brazing,nitrile rubber insulation 9mm thick class O etc comlete 3/8\\" (9.50mm) and 5/8\\" (15.90) QR
22Supllying and fixing of suction/Discharge Copper pipe line in split A.C unit 1.5 ton capacity including cost of brazing,nitrile rubber insulation 9 mm thick class O etc comlete 1/4\\" (6.40mm) and 1/2\\" (12.70) QR
23Supllying and fixing of heavy duty CPVC 20/25 mm OD pipe for condensed water drain with cost of clipping, accessories complete in all respect. QR
24Supllying and fixing of heavy duty CPVC 32 mm OD pipe for condensed water drain with cost of clipping, accessories complete in all respect. QR
25Supply Fabrication and Installation of MS cage for protection of outdoor unit from animal / theft LXWH 1300 mm x 600 x 1200 mm complete in all respect. QR
26Supply and fixing of stand for Out Door Unit of split A.C. QR
27Supllying and fixing of Door Closer. QR Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56317065
AUTHORITY Government Departments
TENDER VALUE 16.92 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Establishment Work Of One In Nyalaya Kachho And Vyam Kachho Of Family Court Of District Court, Maharajganj.
Basic Detail
Tender No 952/Nivida Suchna GKP-Zone-E/M Circle/2026-27 Dt 22.06.2026
Bidding Type Tender
Location
City Maharajganj
State Uttar Pradesh
Key Dates
Publish Date 15 Jul 2026
Submission Date 28 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 16.92 Lakhs
Tender Fee 854
EMD 1.70 Lakhs
Exemption Not Available
Document List
Tendernotice_3 (2).pdf
b22fed1a-7c6a-465a-9e0e-d128dc4d286d.html
BOQ_2188089.xls
Tendernotice_1.pdf
Tendernotice_2 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 11 days
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_3 (2).pdf

html

b22fed1a-7c6a-465a-9e0e-d128dc4d286d.html

xls

BOQ_2188089.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders