Public Administrative Department Local Bodies Closing in 19 days TDR #56316957

Tender For Measles No. Residual Construction Work In Kalyan Mandap At 160, Village Bahadurpur, (Shankarpurwa 1St Ward), Kursi Road.

Issued by Local Bodies · Lucknow, Uttar Pradesh
Tender Value
3.35 Crore
Estimated cost
Bid Submission
29 Jul 2026
19 days left
EMD
10.05 Lakhs
Bank guarantee accepted
Document Fee
4366
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Measles No. Residual Construction Work In Kalyan Mandap At 160, Village Bahadurpur, (Shankarpurwa 1St Ward), Kursi Road.

BOQ

Name of Work:- Khasra No. 160, Gram Bhadurpur, (Shankerpurva 1st ward), Kursi road mein Kalyan mandap mein avsesh nirman karya.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge., All kinds of soil DSR 2023- 2.6.1
2Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR 2023- 2.27
3Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials., All kinds of soil. DSR 2023- 2.26.1
4Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) :, Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :, With Chlorpyriphos /Lindane E.C. 20% with 1% concentration. DSR 2023- 2.35.3.1
5Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378), 250x10 mm DSR 2023- 9.63.1
6Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378), 125 mm DSR 2023- 9.66.1
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). DSR 2023- 4.1.8
8Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth. DSR 2023- 4.17
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR 2023- 4.1.2
10Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete., Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate DSR 2023- 11.3.1
11Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). DSR 2023- 4.10
12Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. DSR 2023- 4.13
13Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-550D or more. - MR-Steel Fe-500D
14Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). DSR 2023- 10.28
15Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer., Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). DSR 2023- 10.15.1
16Centering and shuttering including strutting, propping etc. and removal of form for :, Centering and shuttering including strutting and propping and removal of items for: Foundations, footings, base of columns, etc DSR 2023/5.9.1 DSR 2023- 5.9.1
17Centering and shuttering including strutting, propping etc. and removal of form for :, Suspended floors, roofs, landings, balconies and access platform DSR 2023- 5.9.3
18Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)., Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) DSR 2023- 5.11.1
19Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement, All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 2023- 5.33.1.1
20Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement, All works above plinth level upto floor V level, Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 2023- 5.33.2.1
21Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 2023- 5.1.2
22Centering and shuttering including strutting, propping etc. and removal of form for :, Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers DSR 2023- 5.9.5
23Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:, Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 2023- 6.1.2
24Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level., Cement mortar 1:4 (1 cement :4 coarse sand) DSR 2023- 6.13.2
25Providing & Filling of O.B. brick ballast 25 mm to 40 mm size inside of upper layer in soak pit. 2.25+BRICK BALLAST
26Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :, Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 2023- 6.4.2
2712 mm cement plaster of mix :, 1:6 (1 cement: 6 coarse sand) DSR 2023- 13.4.2
286 mm cement plaster of mix :, 1:3 (1 cement: 3 fine sand) DSR 2023- 13.16.1
2915 mm cement plaster on rough side of single or half brick wall of mix :, 1:6 (1 cement: 6 coarse sand) DSR 2023- 13.5.2
30Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:, New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR 2023- 13.47.1
31Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 2023- 13.80
32Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :, Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture DSR 2023- 13.48.3
33Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR 2022 E-M- 1.11
34Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/PVC conduit as required., 2 Pair DSR 2022 E-M- 1.18.2
35Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. DSR 2022 E-M- 1.19
36Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 20 mm DSR 2022 E-M- 1.21.1
37Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 25 mm DSR 2022 E-M- 1.21.2
38Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 32 mm DSR 2022 E-M- 1.21.3
39Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 15/16 A switch DSR 2022 E-M- 1.24.3
40Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 3 pin 5/6 A socket outlet DSR 2022 E-M- 1.24.4
41Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 6 pin 15/16 A socket outlet DSR 2022 E-M- 1.24.5
42Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., TV antenna socket outlet DSR 2022 E-M- 1.24.7
43Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR 2022 E-M- 1.26
44Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 1 or 2 Module (75mmX75mm) DSR 2022 E-M- 1.27.1
45Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 3 Module (100mmX75mm) DSR 2022 E-M- 1.27.2
46Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 4 Module (125mmX75mm) DSR 2022 E-M- 1.27.3
47Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 6 Module (200mmX75mm) DSR 2022 E-M- 1.27.4
48Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 8 Module (125mmX125mm) DSR 2022 E-M- 1.27.5
49Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required., 12 Module (200mmX150mm) DSR 2022 E-M- 1.27.6
50Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required., Up to 450 mm sweep DSR 2022 E-M- 1.50.1
51Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. DSR 2022 E-M- 1.51
52Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required., 1 run of cable DSR 2022 E-M- 1.53.1
53Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. DSR 2022 E-M- 1.57
54Supplying and fixing PVC batten/ angle holder including connections etc. as required. DSR 2022 E-M- 1.58
55Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 A switch DSR 2022 E-M- 1.24.1
56Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR 2022 E-M- 1.25
57Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required., 100 A.30KA.FPMCCB DSR 2022 E-M- 2.2.13
58Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator), 4 way (4 + 12), Double door DSR 2022 E-M- 2.4.1
59Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator), 6 way (4 + 18), Double door DSR 2022 E-M- 2.4.2
60Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator), 8 way (4 + 24), Double door DSR 2022 E-M- 2.4.3
61Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.), 4 way (4 + 12), Double door DSR 2022 E-M- 2.5.1
62Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., Single pole DSR 2022 E-M- 2.10.1
63Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. DSR 2022 E-M- 2.11
64Supplying and fixing following rating, double pole, the existing MCB DB complete with connections, testing and commissioning etc. as required., 63 A DSR 2022 E-M- 2.12.2
65Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required., 63 A DSR 2022 E-M- 2.13.2
66Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. DSR 2022 E-M- 2.21
67Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR 2022 E-M- 5.4
68Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR-E/M 5.6
69Supplying and laying 6 SWG G.l. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required. DSR 2022 E-M- 5.7
70Supplying and laying 25 mm X 5 mm G.l. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm) DSR 2022 E-M- 5.9
71Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. DSR 2022 E-M- 5.14
72Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. DSR 2022 E-M- 5.15
73Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required. DSR 2022 E-M- 5.16
74Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. DSR 2023- 10.18
75Supply & Fixing of AC 1400mm Sweep, 230/250 Volts, 50 Hz ceilling fan without regulator, standard down rod, blades etc. complete as required. (Standard - Plain Ceiling Fans) A.R. - 1.1
76Supply & Fixing of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan without regulator, standard down rod, blades etc. complete as required. (Standard - Plain Ceiling Fans) A.R. - 1.2
77Supply & Fixing of AC 300mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Heavy Duty) with blades,cover etc. complete as required. A.R. - 6
78Supply & Fixing of AC 230mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Light Duty) with blades,cover etc. complete as required. A.R. - 7
79Supply & Fixing of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including making connection.Complete in all respect. A.R. - 8
80DOWN LIGHT LUMINAIRES Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect., CAT- AAA SOR 2018 (E-M)- 14.1403.a
81DOWN LIGHT LUMINAIRES Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects., CAT- AAA SOR 2018 (E-M)- 14.1404.a
82DOWN LIGHT LUMINAIRES Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial, CAT-AAA SOR 2018 (E-M)- 14.1406.a
83DOWN LIGHT LUMINAIRES Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect., CAT-AA SOR 2018 (E-M)- 14.1413.b
84DOWN LIGHT LUMINAIRES Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect., CAT- AAA SOR 2018 (E-M)- 14.1417.a
85Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 16 sq. mm 4 core SOR 2018 (E-M)- 5.501.(i)
86Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 35 sq. mm 3-1/2 core SOR 2018 (E-M)- 5.501.(k)
87Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 300 sq. mm 3-1/2 core SOR 2018 (E-M)- 5.501.(s)
88Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge., 16 sq. mm 4 core SOR 2018 (E-M)- 5.503.(i)
89Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge., 35 sq. mm 3-1/2 core SOR 2018 (E-M)- 5.503.(k)
90Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge., 300 sq. mm 3-1/2 core SOR 2018 (E-M)- 5.503.(s)
91Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 16 sq. mm SOR 2018 (E-M)- 5.504.(d)
92Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 35 sq. mm SOR 2018 (E-M)- 5.504.(f)
93Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 300 sq. mm SOR 2018 (E-M)- 5.504.(n)
94Supply and fixing of vertical air termination final rod comprising of 300mm long x 25mm dia. Copper rod with one pointed prong and 100mm dia x 3 mm thick base plate etc. complete in all respect. SOR 2018 (E-M)- 7.712 (A)
95Supply and fixing of horizontal air termination (roof conductor) of 25mm x 3mm G.I. strip, G.I. clamps on surface complete in all respects as approved by Engineer-in-charge. SOR 2018 (E-M)- 7.710
96Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. SOR 2018 (E-M)- 7.718
97Supply and fixing of testing joint of copper strip 32mm x 6mm and 150mm long with tinned of brass bolts and nut etc. complete in all respect. SOR 2018 (E-M)- 7.720
98Cubical Panel Board ( MCCB Type) Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. (Incoming - 400 Amp MCCB -1 No), Outgoing -100 Amp.MCCB-3Nos. & 63 Amp.MCCB-2Nos., Cat. B.Pannel Cubicle Type SOR 2018 (E-M)- 8.813.(e).(ii)
99Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required., 63 A TP&N DSR 2022 E-M- 2.1.2
100Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator), 6 way , Double door DSR 2022 E-M- 2.3.1
101Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required., 63 A DSR 2022 E-M- 2.15.3
102Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conformington MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, netmetering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10years and 80% at the end of 25 years. b)Power Conditioning Unit (PCU) of 350-800VDC Input voltage range and 400VAC, three phase, 4wire, 50Hz+/-2.5Hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0to50degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for in coming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection.f)Connections & Inter connections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 1kWp D.S.R-2022/25.1
103Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. 651 (SOR 2018, E/M)
104Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect., 40 A TPN SOR 2018 (E-M)- 8.807.(f) (ii)
105SOR EM 2018 1423 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above protection complete in all respect. - PSR.02.
106Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 10 sq. mm 4 core SOR 2018 (E-M) (Labour Rate)- 5.501.(h)
107FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL), Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic, Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (includin, Ten Loop Panel. DSR 2022 E-M- 17.2.1.1
108FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL), Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic, Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (includin, Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. DSR 2022 E-M- 17.2.2
109FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL), Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic, Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (includin, Supplying, installation, testing & commissioning of addressable fire control module complete as required. DSR 2022 E-M- 17.2.10
110FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL), Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic, Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (includin, Supplying, installation, testing & commissioning of addressable manual call point complete as required. DSR 2022 E-M- 17.2.14
111FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL), Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic, Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (includin, Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. DSR 2022 E-M- 17.2.15
112FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL), Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic, Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (includin, Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. DSR 2022 E-M- 17.2.17
113FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL), Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic, Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (includin, Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. DSR 2022 E-M- 17.2.19
114Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads., 900 lpm at 35 m Head DSR 2022 E-M- 43191
115PIPES & ACCESSORIES Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required., 150 mm. Dia DSR 2022 E-M- 18.6.2
116Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :, 80 mm dia DSR 2022 E-M- 18.7.6
117Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :, 100 mm dia DSR 2022 E-M- 18.7.7
118Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :, Single headed Stainless steel DSR 2022 E-M- 18.9.2
119Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :, 80 mm dia DSR 2022 E-M- 18.11.4
120Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :, 100 mm dia DSR 2022 E-M- 18.11.5
121Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. DSR 2022 E-M- 18.13
122Supply and fixing of heavy duty cadmium plated copper connector with end plate complete in all respect., Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. SOR 2018 (E-M)- 11.11.1131
123Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. (K) 35 sq. mm 3-1/2 core. A.R.-20
124Supplying, installation, testing and commissioning of silent type DG sets, AMF panel, bus ducting/ cables from DG sets to essential panel, synchronizing panel where required, DG set enclosure room sound insulation/ventilation/smoke exhaust as required, earthing of DG set system, control cabling, fuel tank/piping, DG set exhaust piping/ exhaust chimney as per CPCB norms, civil works connected with DG sets including foundation as required. 6.3.1
125Supply & installation of Split Direct Expansion Air-Conditioners suitable for operation on A/C supply single phase 50HZ 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitor, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High Wall Chorded/Cordless) Suitable Capacity 3 Core sheathed/ PVC copper cable and a battery operated wireless remote unit., 1.5 TR, BEE Star Rated: 5 Star, EER 3.4 SOR 2018 (E-M)- 15.1503.(B).(i)
126Supply & installation of Split Direct Expansion Air-Conditioners suitable for operation on A/C supply single phase 50HZ 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitor, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High Wall Chorded/Cordless) Suitable Capacity 3 Core sheathed/ PVC copper cable and a battery operated wireless remote unit., 2.0 TR, BEE Star Rated: 5 Star, EER 3.4 SOR 2018 (E-M)- 15.1503.(C).(i)
127Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 @3795.00
128Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). DSR - 2020 (Horticulture)- 2.1
129Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). DSR - 2020 (Horticulture)- 2.2
130Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :, Screened through sieve of I.S. designation 16 mm DSR - 2020 (Horticulture)- 2.4.2
131Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge DSR - 2020 (Horticulture)- 2.9
132Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately)., With grass Turf DSR - 2020 (Horticulture)- 2.10.2
133Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately), Holes 90 cm dia, and 90 cm deep DSR - 2020 (Horticulture)- 2.14.2
134Fine dressing of the ground. DSR - 2020 (Horticulture)- 2.7
135Providing and fixing SS sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm. SOR-2020-21 chap-1 item no. 10(g) - SS Sliding Bolt01
136Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm- S/F Brass tower bolts
137Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete., 125mm DSR 2023- 9.165.1
138Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:, 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DSR 2023- 9.21.1
139Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I), On one side only. DSR 2023- 9.22.1
140Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). DSR 2023- 9.23
141Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made., Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ heat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 125 mm. DSR 26.86.6
142Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately), Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick. DSR 26.87.1
143Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds., Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body., Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body., Two and half track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body., Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body., Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system, (Height upto 1.8m). DSR 2023- 9.147.A4.2
144Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):, With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) DSR 2023- 21.3.2
145Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia. 0.50 mm all complete., With 12 mm mild steel U beading. DSR 2023- 9.135.2
146Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :, \\"(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR 22.7.1\\"
147Providing & fixing of 12 mm Toughened Glass Door with all hardware as per design with edge polish m/c top and bottom pivot and bottom lock with handle all complete as per drawing, specification and direction as approved by Engineer -in-Charge. PSR
148Providing & fixing of 12 mm Toughened Glass Partition with all hardware as per design with edge polished all complete as per drawing, specification and direction as approved by Engineer -in-Charge. MR
149Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20mm made of 0.5mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip intiles into spring 'T' with :, GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. DSR 2023- 12.54.1
150Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. DSR 2023- 11.39
151Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR 2023- 8.31
152Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete., Size of Tile 600x600 mm DSR 2023- 11.41.2
153Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete., Size of Tile 600x600 mm DSR 2023- 11.46.2
154Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :, Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick. DSR 2023- 11.26.1
155Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels., Granite stone slab colour black, Cherry/Ruby red, Area of slab over 0.50 sqm DSR 2023- 8.2.2.2
156Providing and fixing glass strips in joints of terrazzo/ cement concrete floors., 40 mm wide and 4 mm thick. DSR 2023- 11.13.1
157Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:, Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: New work (two or more coats) over and including Water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. DSR 2023- 13.41.1
158Providing /laying of light cinder filling/ 25 TO 40 mm O.B. brick ballast under floor of toilet /sunken roofs. PSR
159Cost of Filtration tank (2.5 m dia 3.00 deep)
160Cost of pvc pipe drain
161Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. DSR 2023- 16.19
162Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). DSR 2023- 5.3
163Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality, L D - 2.5, Square shape 450 mm internal dimensions DSR 2023- 19.19.1.2
164Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :, With 20x20 mm square bar DSR 2023- 19.15.1
165Providing and fixing soil, waste and vent pipes :, 100 mm dia., Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. DSR 2023- 17.35.1.2
166Providing and fixing plain bend of required degree., 100 mm dia, Sand cast iron S&S as per IS : 3989 DSR 2023- 17.39.1.2
167Supplying and fixing C.I. cover without frame for manholes :, 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg. DSR 2023- 19.18.2
168Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer., Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). DSR 2023- 10.13.1
169Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete., Fixed to steel windows by welding DSR 2023- 9.48.1
170Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement., 18 mm thick. DSR 2023- 11.6.1
171Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :, Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture DSR 2023- 13.48.2
172Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:, White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests DSR 2023- 17.1.1
173Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :, W.C. pan with ISI marked white solid plastic seat and lid DSR 2023- 17.2.1
174Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :, Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern DSR 2023- 17.4.3
175Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:, White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap DSR 2023- 17.7.4
176Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. DSR 2023- 17.16A
177Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :, Rectangular shape 453x357 mm DSR 2023- 17.32.2
178Providing and fixing soil, waste and vent pipes :, 75 mm diameter :, Centrifugally cast (spun) iron socketed pipe as per IS: 3989. DSR 2023- 17.35.2.2
179Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and includingcement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :, For 100 mm dia. Pipe DSR 2023- 17.37.1
180Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and includingcement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :, For 75 mm dia. Pipe DSR 2023- 17.37.2
181Providing and fixing toilet paper holder :, C.P. brass DSR 2023- 17.34.1
182Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete., 75 mm dia, Sand cast iron S&S as per IS- 3989 DSR 2023- 17.38.2.2
183Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete., 100 mm dia, Sand cast iron S&S as per IS - 3989 DSR 2023- 17.38.1.2
184Providing and fixing heel rest sanitary bend, 100 mm dia, Sand cast iron S&S as per IS - 3989 DSR 2023- 17.40.1.2
185Providing and fixing double equal plain junction of required degree., 100x100x100x100 mm, Sand cast iron S&S as per IS - 3989 DSR 2023- 17.42.1.2
186Providing and fixing double equal plain junction of required degree., 75x75x75x75 mm, Sand cast iron S&S as per IS - 3989 DSR 2023- 17.42.2.2
187Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter:, 100 mm DSR 2023- 17.58.1
188Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter:, 75 mm DSR 2023- 17.58.2
189Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. DSR 2023- 17.71
190Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. DSR 2023- 17.22A
191Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :, 100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS: 3989. DSR 2023- 17.60.1.1
192Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour., 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. DSR 2023- 17.73.2
193Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :, 150 mm diameter DSR 2023- 18.22.2
194Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :, Kitchen sink with drain board, 510x1040 mm bowl depth 250 mm. DSR 2023- 17.10.1.1
195Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc., 15 mm nominal outer dia .Pipes. DSR 2023- 18.8.1
196Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc., 20 mm nominal outer dia .Pipes. DSR 2023- 18.8.2
197Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc., 25 mm nominal outer dia .Pipes. DSR 2023- 18.8.3
198Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :, 25 mm nominal bore DSR 2023- 18.17.1
199Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :, 20 mm nominal bore. DSR 18.17.1A
200Providing and fixing uplasticised PVC connection pipe with brass unions :, 45 cm length, 20 mm nominal bore DSR 2023- 18.21.2.2
201Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931:, 15 mm nominal bore. DSR 2023- 18.49.1
202Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :, 15mm nominal bore DSR 2023- 18.53.1
203Making khurras 45x45 cm with average minimum thickness of5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. DSR 2023- 12.22
204Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes., 110 mm diameter DSR 2023- 12.41.2
205Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion., Coupler, 110mm DSR 2023- 12.42.1.2
206Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion., Shoe (Plain), 110 mm Shoe DSR 2023- 12.42.6.2
207Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete., 110 mm DSR 2023- 12.43.2
208Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :, Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 2023- 19.7.1.1
209Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:, 100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 2023- 19.4.1.1
210Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. DSR 2023- 18.48
211Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required., Group C DSR 2022 E-M- 1.10.3
212Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required., 2 X2.5 sq. mm + 1X2.5 sq. mm earth wire DSR 2022 E-M- 1.14.2
213Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required., 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR 2022 E-M- 1.14.3
214Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required., 2 X 6 sq. mm + 1 X 6 sq. mm earth wire DSR 2022 E-M- 1.14.4
215Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required., 4 X 6 sq. mm + 2 X 6 sq. mm earth wire DSR 2022 E-M- 1.14.9
216Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required., 4 X 10 sq. mm + 2X6 sq. mm earth wire DSR 2022 E-M- 1.14.10
217Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required., 4 X 16 sq. mm + 2 X 6 sq. mm earth wire DSR 2022 E-M- 1.14.11
218Providing/FixProviding & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts.(30) As per Quotation ing Fire man axe. Make.MR
2191200x900 mm (Indoor Cabinet) Only Frame (E)
220Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. (54) As per Quotation
221Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. SOR 2018 (E-M)- 11.1132
222Supply Installation , Testing & Commissioning of 20 Passenger,0.75 mps,3 stops , 3 Openings.LIFTS with power operated centre opening doors and AC variable voltage & variable frequency control,car safety & Governor, Guides, guide rails, ropes, car platform, cabin finishes (stainless steel), car & landing doors (stainless steel), hoist motors, braking system, Automatic Rescue Device (ARD) etc. complete as per the CPWD Specifications and realated IS standards upto date. PAR-2023 3.1.4
223Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (K) 35 sq. mm 3-1/2 core A.R.-19
224Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. DSR 2023- 16.68
225Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. DSR 2023- 11.27 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56316957
AUTHORITY Local Bodies
TENDER VALUE 3.35 Crore
LAST DATE 29-07-2026
Authority
Authority Name Lucknow Development Authority
Work Description Tender for Measles No. Residual Construction Work In Kalyan Mandap At 160, Village Bahadurpur, (Shankarpurwa 1St Ward), Kursi Road.
Basic Detail
Tender No 65/E-NIVIDA/C.E./2026-27/3
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 06 Jul 2026
Submission Date 29 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 3.35 Crore
Tender Fee 4366
EMD 10.05 Lakhs
Exemption Not Available
Document List
BOQ_2188021.xls
TENDER.pdf
Tendernotice_1.pdf
586da89c-afd8-4aed-a62f-0fd34e30bc63.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2188021.xls

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

html

586da89c-afd8-4aed-a62f-0fd34e30bc63.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders