Tender for Tender for The Work Of Establishment Of One In The Court Chambers Of District And Sessions Judge And Additional Judge Of District Court Kushinagar And Associated Retiring Chambers.
Tender Overview
Project Description
Tender for The Work Of Establishment Of One In The Court Chambers Of District And Sessions Judge And Additional Judge Of District Court Kushinagar And Associated Retiring Chambers.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Jul-2026 | corrigendum | Date | 27-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | (PART - A) Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering. All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only. Incommer 630 Amp, FP MCCB-01 No, Outgoing 200 Amp, FP MCCB - 01 No. & 100 Amp, FP MCCB -2 Nos. 63 Amp, FP MCCB -2 Nos.32 Amp, FP MCCB -1 No |
| 2 | same as sr.no. 1 Incommer - 200 Amp, FP MCCB -01 No and Outgoing- 63 Amp FP MCCB - 03 Nos. |
| 3 | same as sr.no. 1 Incommer - 100 Amp, FP MCCB -01 No and Outgoing 63 Amp FP MCCB - 02 Nos. |
| 4 | S&F of 630 Amp. 4 Pole Change Over Switch on 50mm x 50mm x 6mm angle iron frame, Including the cost of labour, T&P, Painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 800 Amp. 4 Pole on 50mm x 50mm x 6mm angle iron frame. |
| 5 | S&F of 200 Amp. 4 Pole Change Over Switch on 50mm x 50mm x 6mm angle iron frame, Including the cost of labour, T&P, Painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 800 Amp. 4 Pole on 50mm x 50mm x 6mm angle iron frame. |
| 6 | S&F of 100 Amp. 4 Pole Change Over Switch on 50mm x 50mm x 6mm angle iron frame, Including the cost of labour, T&P, Painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 800 Amp. 4 Pole on 50mm x 50mm x 6mm angle iron frame. |
| 7 | Supplying and fixing following way, horizontal typethree pole and neutral, sheet steel, MCB distributionboard, 415 V, on surface/ recess, complete withtinned copper bus bar, neutral bus bar, earth bar, dinbar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator).2.4.1 4 way (4 + 12), Double door |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the 2X 6sq.mm+1X6sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 9 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 10 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 Amodular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, Double Pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 12 | Supplying and fixing of 63 Amp. 4 Pole MCB complete in all respect. |
| 13 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 Amodular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (Less cost of single pole MCB |
| 14 | Supply and laying of Al. Conductor PVC Insulated armoured served sheathod cables 1100V grade at a depth of 400mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall ne fixed on M.S Clamps etc of suitable size or as directed by Engineer in Charge complete in all respect inculuding excavation and refilling. The armouning of the cable shall be properly connected with the earth conductor by clamps etc. (i) 630sq. mm 3-1/2 Core |
| 15 | same as sr.no 14. (ii) 150 sq. mm 3-1/2 Core |
| 16 | same as sr.no 14. (ii) 70 sq. mm 3-1/2 Core |
| 17 | same as sr.no 14. (ii) 25 sq. mm 3-1/2 Core |
| 18 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 19 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 20 | Providing and fixing 6 SWG dia G.I. wire on surfaceor in recess for loop earthing as required. |
| 21 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 22 | Providing and laying of 1800 mm X 900mm X 12 mm thick chequered matting of tested quality. |
| 23 | (PART - B ) SITC of Air cooled high wall split - inverter AC of Make- Carrier/Panasonic/Blue Star/LG of followings capacity with complete indoor unit, Outdoor unit, concealed copper refrigerant piping with proper cooling capacity and insulation . The AC shall be able to operate and function properly up to 52 degree Celcius ambient temperature. a) 2.0 TR 5 Star BEE rating |
| 24 | SITC of Air cooled high wall split - inverter AC of Make- Carrier/Panasonic/Blue Star/LG of followings capacity with complete indoor unit, Outdoor unit, concealed copper refrigerant piping with proper cooling capacity and insulation . The AC shall be able to operate and function properly up to 52 degree Celcius ambient temperature. b) 1.5 TR 5 Star BEE rating |
| 25 | SITC of 5 KVA Voltage Stablizer for 2.0 TR 5 Star BEE rating AC Upto V ( 130 - 300 Volt) Copper Winding. |
| 26 | SITC of 4 KVA Voltage Stablizer for 1.5 TR 5 Star BEE rating AC Upto V ( 130 - 300 Volt) Copper Winding. |
| 27 | Supplying and fixing of 2.5 sqmm, 3 core Round cable for Connection of power point to Stablizer to indoor unit of AC. |
| 28 | Supplying and fixing of 2.5sqmm, 4 core Connecting Round cable for indoor to Outdoor of AC. |
| 29 | Supplying, laying and fixing of suction / Discharge Copper pipe line in split A.C unit 2.0 ton capacity including cost of brazing, nitrile rubber insulation 9 mm thick class O etc comlete 3/8\\" (9.50 mm) and 5/8\\" (15.90 mm) |
| 30 | Supplying, laying and fixing of suction / Discharge Copper pipe line in split A.C unit 1.5 ton capacity including cost of brazing, nitrile rubber insulation 9 mm thick class O etc comlete 1/4\\" (6.40 mm) and 1/2\\" (12.70 mm) |
| 31 | Supplying, laying and fixing of heavy duty CPVC 32 mm OD pipe for condensed water drain with cost of clipping, accessories complete in all respect. |
| 32 | Supplying and fixing of stand for Out Door Unit of split A.C |
| 33 | Supplying, Fabrication and installation of M.S. wired cage size 1300 mm X 600 mm X 1200 mm for protection of outdoor unit from animal /theft with complete in all respect. |
| 34 | Supplying and fixing of Door Closer. :- ii) GST @ 18% Extra Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender