Environment and Forests Government Departments Closing in 6 days TDR #56316038

Tender For Cost Of Construction Of Solar Power Fencing At Kannammamodu Piyanippara In Neyyar

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
4.25 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
6 days left
EMD
10700
Bank guarantee accepted
Document Fee
1003
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Cost Of Construction Of Solar Power Fencing At Kannammamodu Piyanippara In Neyyar

BOQ

Name of Work:-
Sl. No. Item Description
1Supplying and Installation of Solar Panel & it; br & gt; 250w/24V with 10 year warranty
2Supply and Installation of Battery (Tubular) 150 Ah/ 12V, c-10 battery with 5 year warranty
3Battery Charge Controller & It; br & gt; Solar charge controller to regulate charging of battery 5 year warranty
4Energiser Safety standards with BIS 302-2-76 IEC 335-2-76, switch High - Medium- Low power setting. Solar panel option to recharge 12V battery, full and reduced power output terminals operate different fences independently
5Leadout cable double insulated with standing 15KV voltage and inner core wire must be hot dip galvanised
6Supply and fixing corner post assembly 8 ft 2', 14 guage thickness, including cost of GI pipe, cutting, welding, painting and fixing
7Supply and installation of supporting posts & It; br & gt; 8 ft 1 & #39; 14 guage thickness
8Intermediate posts 8 ft (25 mm x 25mm x 3mm) T post or 16 mm TMT rod, including cost of T post, Cutting welding charges etc.., (Limit to actual)
9Strain insulator & It; br & gt; Must of Polypropelene plastic rated for 15 KV, UV stabilised & It; br & gt;
10PP Reel Insulator & It; br & gt; Must be of virging plastic material polypropelene or equivalent & It; br & gt;
11Joint clamps with Nut and Bolts & It; br & gt; Spring steel capable of taking compression loads, galvanised & It; br & gt;
12Tension Spring & It; br & gt; 15 cm length with stand 300 kg & It; br & gt;
13Wire tightener in suit tightners for proper tensioning of wires should be made from alloy-nonrusting quality
14Gate set 02 Gate, with 05 steel rope with handle (Five handles for one gate) and spring assembly. Handle to be made of polythelene
15Earth Device Steel Road with earthing mixture (1.5\\" pipe) 6 ft pipe must contain earth mixture capable of retaining moisture and 8 mm dia copper plated IS -3043 rod non-rusting quality with earthing compound 10 kg/km
16Supply of 12 Guage ACSR wire & It; br & gt; 12 guage 2.5 mm wire dia & It; br & gt;
17Supply of C-clamp & It; br & gt; 60 Micron thick & It; br & gt;
1814 guage winding wire & It; br & gt; High quality zinc coated wire & It; br & gt;
19Warning sign boards & It; br & gt; polyethylene Plastic with statutory warning and signs & It; br & gt;
20Tool Kit & It; br & gt; Includes wire tighting handle, Twisting tool, Pilers, Double handed spanner & It;br & gt
21Base unit box with stand 18 guage thickness lockable GI steel box, GI sheet painted and fixed on 100 NB class and should be capable of housing Battery and Energiser
22Degital Volt meter must disply fence voltage, digitally upto 12KV, made of non-shocking material
232. Earth Work : Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
24Aligning the fence in the field as per the direction of departmental officers, clearing the fence line of all weeds to a width of 1.5 m, fixing the corner posts at an approximate distance 50 m in pits of size 30 cm x 30cm x 45cm in hard soil consolidated by ramming gravel and jungle stone pieces and supported by support posts, fixing intermediate posts by hammering the same in to hard earth to a depth of 45 cm, drawing the conducting wire through PP reel insulators tied to the intermediate posts using winding wire and stretching to required strength by connecting the ends to superstarin insulators tied to the corner posts in 5 strands, the bottommost line at an average height of 15 cms from the ground and the other stands at approximate intervals of 20 cm, 25 cm, 30 cm and 40 cm connecting conducting wire in every strand across each corner post by means of jointing clamps, fixing wire tightener in every strand at approximate interval of 200 m, connecting tension spring in the topmost two conductors at approximate interval of 200 m, providing flood chain set and flood control unit at rivercrossing points, connecting super earth kit to the earth conductor by means of lead out cable and jointing clamp, fixing vertical conducting wire in the forest side of the fence supported by semicircular conducting wire loop fixed to the conducting wire strand by means of joining clamp for protecting the post from wild animals, providing gate assembly at places as decided by the departmental officers by means of rope gate set fixed to corner posts acting as gate posts by means of superstrain insulators at the fixed end and conducting hook at the detachable end, providing line connection at the gate point through lead out cable laid underground and energizing the live conductors of the fence by means of the energiser fixed at suitable locations at approximate distance of 2 km along the fence, connected to the live wire earth wire by means of lead out cable providing sufficient number of earth kits in the line to the earth wire , connecting the tubular battery to the energizer through lead out cable and connecting the solar panel to the battery by means of 2 core wire through charge control unit and fixing lightning diverter in the circuit at appropriate location to protect the energizer from lightning voltage, providing and fixing stand for the solar panel and metallic box for safe storage of energizer and battery, testing the circuit for required current and voltage and commissioning the fence installation.
25Supply of lightning diverter of standard make having capacity to divert up to 20 KV Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56316038
AUTHORITY Government Departments
TENDER VALUE 4.25 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Forest Department
Work Description Tender for Cost Of Construction Of Solar Power Fencing At Kannammamodu Piyanippara In Neyyar
Basic Detail
Tender No KFDDO/42521/2025/A1
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 04 Jul 2026
Submission Date 14 Jul 2026
Open Date 16 Jul 2026
Finance
Tender Value 4.25 Lakhs
Tender Fee 1003
EMD 10700
Exemption Available
Document List
a0d8acda-9b6a-43a8-9f5d-40a051e998b8.html
BOQ_1452549.xls
Tendernotice_1.pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

a0d8acda-9b6a-43a8-9f5d-40a051e998b8.html

xls

BOQ_1452549.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders