Housing Urban and Rular Development Government Departments Closing in 0 days TDR #56315755

Tender For Providing And Fixing Of Water Cooler, Ro And Air Conditioner At Ncc Bhawan, Sector-19, Rohini, Delhi

Issued by Government Departments · Delhi, Delhi
Tender Value
11.92 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
0 days left
EMD
23855
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Providing And Fixing Of Water Cooler, Ro And Air Conditioner At Ncc Bhawan, Sector-19, Rohini, Delhi

BOQ

Name of Work:- Providing and Fixing of Water Cooler, RO and Air Conditioner at NCC Bhawan, Sector-19, Rohini, Delhi
Sl. No. Item Description
1Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control and suitable all accessories like stand, fastner, nut bolt etc for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling onlya) 1.5 TR with 5 Star BEE Rating (Minimum cooling capacity 5200 Watt)
2Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.Inverter Type- Cooling onlya) 2.0 TR with 5 Star BEE Rating (Minimum cooling capacity 6300 Watt)
3Supply, installation, testing & commissioning of floor mounted 150 ltrs storage capacity water cooler with nominal cooling capacity of 150 ltrs per hour, all outer panels, water storage tank & trough to be of Stainless steel Grade 304 with anti corrosive pre coating, provided with 2 nos. water outlet chrome plated brass faucets, fitted with energy efficient rotary compressor, suitable for operation on 230 V/50 Hz single phase AC supply complete as reqd. at site.
4Supplying, installation, testing & commissioning of Supply of Reverse Osmosis Purification System with capacity of 50 LPH for providing clean, safe & pure drinking water. Multi- Stage Purification Process Ensures every drop of water is pure and safe for consumption, Auto flusing of membranes ensures the water purifiers clean themselves from time to time, to maintain good hygiene. Makes water both chemically and micro- biologically potable by reducing hardness, TDS. Heavy metal contaminants and water –borne pathogenic microtganisms. Dimensions )WxDxH)=530mm x 340 mm x 450mm, weight- 27 kgs approx., outer body CRCA Steel, Purified Water recovery 50%. The Company is having their NABL Accredited Lab Testing facilities in Delhi. Our Product Is ISO 9001 , Indian Medical Association Certified GC (Green Company) Mark BIS certificate,ISO 14001, ISO17025, ISO9001., with water inlet & outlet connections, suitable for operation on 230 V/50 Hz single phase AC supply complete as reqd. at site.
5Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 5/8\\"and 3/8\\" suitable for 1.5/2 TR STAC duly insulated by nitrile rubber, covered with MS pipe for safety of the pipe along with necessary support, clamps, brackets as required as per site requirement.
6Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 1/2\\"and 1/4\\" suitable for 1.5/2 TR STAC duly insulated by nitrile rubber, covererd with MS pipe for safety of the pipe along with necessary support, clamps, brackets as required as per site requirement.
7Supplying of following accessories for the existing 1.5 TR/ 2 TR. capacity WTAC / STAC unit, using existing man power for replacement on day to day maintenance work: a) 15 Amp 3 Pin plug Top (ISI Marked)
8b) 3 core PVC insulated PVC sheathed copper wire 2.5 Sq.mm copper flexible
9Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
10Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
11Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm
12b) 25 mm
13Supplying and fixing of following sizes of U-PVC feeder trunking with cover whereever necessary as per length of run on the existing wall i/c band, tee, Coupler, Elbow and others items etc. as required at site. a) 100 mm x 50 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56315755
AUTHORITY Government Departments
TENDER VALUE 11.92 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Providing And Fixing Of Water Cooler, Ro And Air Conditioner At Ncc Bhawan, Sector-19, Rohini, Delhi
Basic Detail
Tender No 33/EE(E)/NWED/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 04 Jul 2026
Submission Date 13 Jul 2026
Open Date 13 Jul 2026
Finance
Tender Value 11.92 Lakhs
Tender Fee Ref. Documents
EMD 23855
Exemption Available
Document List
53c45eac-bf6f-4626-b8c0-cf2b66e98ec8.html
BOQ_392197.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
html

53c45eac-bf6f-4626-b8c0-cf2b66e98ec8.html

xls

BOQ_392197.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders