Power Government Departments Closing in 16 days TDR #56314428

Tender For Augmentation Of Gss Kathua From 3X50mva To 4X50mva By Way Of Supply Installation Testing and Commissioning of One 132/66Kv,50Mva Power Transformer With Allied Works, Construction Of New 132 Kv Line Bay, Conversion Of Existing Line Bay To T

Issued by Government Departments · Kathua, Jammu and Kashmir
Tender Value
15.22 Crore
Estimated cost
Bid Submission
24 Jul 2026
16 days left
EMD
30.44 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kathua → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Augmentation Of Gss Kathua From 3X50mva To 4X50mva By Way Of Supply Installation Testing and Commissioning of One 132/66Kv,50Mva Power Transformer With Allied Works, Construction Of New 132 Kv Line Bay, Conversion Of Existing Line Bay To Transformer Bay, Uprating Of Existing Twin Bus Bar From Acsr Zebra To Twin Moose Conductor At 66 Kv Yard,Extension Of Control Room Building, Supply Installation Testing and Commissioning of Battery Bank And Charger (300 Ah, 110V), Replacement Of Old And Obsolete Ac,Dc Board And 250 Kva Auxilliary Transformer At 132/66 Kv Grid Station Kathuaand Allied Works.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Jul-2026 CORRIGENDUM 01 Other 24-Jul-2026

BOQ

Name of Work:- Augmentation of GSS Kathua from 3x50MVA to 4x50MVA by way of SITC of one 132/66KV,50MVA Power Transformer with allied works, Construction of new 132 KV Line Bay, Conversion of existing Line bay to Transformer Bay, Uprating of existing Twin Bus Bar from ACSR Zebra to Twin Moose conductor at 66 KV yard,Extension of control room building, SITC of Battery Bank and Charger (300 AH, 110V), replacement of old and obsolete AC,DC board and 250 KVA Auxilliary transformer at 132/66 KV Grid Station Kathuaand allied works.
Sl. No. Item Description
1Design Engineering, Manufacture, testing at manufacture’s work place, packing and forwarding, insurance. Supply of Main Equipments /materials at 3x50MVA 132/66KV Grid Station Kathua
2Cost of 40/50 MVA, 132/66 KV Three PhasePower Transformers with OLTC, SCADA Compatible RTCC, NIFPS, HV and LV connectors and other required accessories and fittings with online DGA monitoring kit, online dehydration kit and maintenance free automatic Breathers as per detailed technical specs, Mandatory spares as per SBD (current density for HV/LV winding not more than 2.4 A/sq mm. Core flux density not more than 1.5T)
3Galvanised Structures
4Galvanised Nuts and Bolts
55 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS,alvanized steel wire/ strip armoured stranded copper conductor control cable complete
616 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, alvanized steel wire/ strip armoured stranded copper conductor control cable complete
719 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, alvanized steel wire/ strip armoured stranded copper conductor control cable complete
83.5 Core, 25 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, alvanized steel wire/ strip armoured stranded copper conductor control cable complete
9400 sq mm ACSR ZEBRA,(a) Alumunium=54/3.18 mm(b) Steel=7/3.18 mm Overall dia 28.62mm.Approximate Wt 1621Kg/Km Ultimate breaking Load=130.32 KN
10Single Tension Fittings For Single Zebra shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN.
11Single Suspension Fittings For Single Zebra shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.Minimum Ultimate strength (Tensile strength) shall be 70 KN.
12T Clamps Twin 0.4 / Twin 0.4, made of Alluminium Alloy and shall comply in all respects with IS:55611970 (latest edition
13Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected
147/3.15 mm G.I. Wire for ground conductor
15Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding conductivity of GSS ground wire
16Earth Mat (40mm dia steel bars) as per approved design, Galavanised Iron (75mm x 12mm/ 50mm x 6 mm) risers for Equipment and Structural Earthing
17Rail Track
18Erection Testing and Commission of Main Equipments for installation of 50MVA transformer at GSS Kathua
19cost of 40/50 MVA, 132/66 KV Three PhasePower Transformers with OLTC, SCADA Compatible RTCC, NIFPS, HV and LV connectors and other required accessories and fittings with online DGA monitoring kit, online dehydration kit and maintenance free automatic Breathers as per detailed technical specs, Mandatory spares as per SBD (current density for HV/LV winding not more than 2.4 A/sq mm. Core flux density not more than 1.5T)
20Galvanised Structures
21Galvanised Nuts and Bolts
225 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS,alvanized steel wire/ strip armoured stranded copper conductor control cable complete
2316 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, alvanized steel wire/ strip armoured stranded copper conductor control cable complete
2419 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, alvanized steel wire/ strip armoured stranded copper conductor control cable complete
253.5 Core, 25 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, alvanized steel wire/ strip armoured stranded copper conductor control cable complete
26400 sq mm ACSR ZEBRA,(a) Alumunium=54/3.18 mm(b) Steel=7/3.18 mm Overall dia 28.62mm.Approximate Wt 1621Kg/Km Ultimate breaking Load=130.32 KN
27Single Tension Fittings For Single Zebra shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN.
28Single Suspension Fittings For Single Zebra shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.Minimum Ultimate strength (Tensile strength) shall be 70 KN.
29T Clamps Twin 0.4 / Twin 0.4, made of Alluminium Alloy and shall comply in all respects with IS:55611970 (latest edition
30Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected
317/3.15 mm G.I. Wire for ground conductor
32Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding conductivity of GSS ground wire
33Earth Mat (40mm dia steel bars) as per approved design, Galavanised Iron (75mm x 12mm/ 50mm x 6 mm) risers for Equipment and Structural Earthing
34Rail Track
35Civil works for transformer
36Concreting of yard & Laying Of Gravel
37Laying of Transformer foundations for Three phase 50 MVA Transformer (as per Drawing)
38nstruction of Oil sump & Tank for Three phase 50 MVA Power Transformer (as per drawing)
39Laying of 132 KV Column foundations (as per Drawing)
40Supply of Main Equipments and allied materials for Construction of 132KV line bay and conversion of existing line bay to transformer bay complete job
413 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 2500 Amps or higher, of 3 phase, 50 c/s and 40 KA for 1 second) along with supporting structures etc. complete in all Respects SS BODY,UNIVERSAL SPRING CHARGING MOTOR WITH MANDATORY SPARES
42145kV, 50c/s , 2500 A, SCADA Compatible, 40 KA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Switch. COPPER FIXED AND MOVING CONTACTS/ COPPER CURRENT CARRYING PARTS, GALVANISED IRON MECHANISM BOX.
43145kV, 50c/s , 2500 A, SCADA Compatible, 40 kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Switch. COPPER FIXED AND MOVING CONTACTS/ COPPER CURRENT CARRYING PARTS, GALVANISED IRON MECHANISM BOX
44Single phase, 50 c/s 145KV Current Transformers (600-300-150/1-1-1-1-1 A or 1200600-300/1-1-1-1-1A or 2000-1600-1200/1-1-1-11A or as per site specifications), 40 KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA 3 NO PS CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
45Neutral Current Transformer with Current Rating 1A/5A and VA Burden 15VA Ratio as per site specifications. 02 No PS class cores, 01 No 0.2s core, GALVANISED TANK 31.5KA for one second, rated dynamic current 31.5KA(peak), including first fill of transformer oil plus 20% extra and all accessories, auxiliaries Etc.
46Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor, class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
47132KV Control and Relay Panel for Transformer bay simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER with IEC 61850 compatibility, including Differential Protection, Directional O/C & E/F Protection (on HV & LV side), numerical communicable REF protection relay, Over Fluxing Protection Local Breaker Backup (LBB) Protection separate relays for primary and backup protection
48132KV Post Insulators Solid Core Type/ Polymer Type, Power Frequency Withstand Voltage 275 KV RMS Dry lightning impulse withstand voltage ± 650 (KVP)
49Single phase, 50 c/s, 72.5 kV Current Transformers (1600-1200-800/1-1-1-1-1 A or 1200-800-400/1-1-1-1-1A or 2000-1600-1200/1-11-1-1 A or as per site specifications), 31.5 KA for one second, Class A insulation, Burden 20 VA 3 NO PS CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill of transformer oil plus 20% extra and all accessories, auxiliaries Etc. Complete in all respects
50Single phase, 50 c/s, outdoor, metal oxide gapless type, 60 kV (rms), class 3 arresters including surge counters / monitors, insulating base and all associated accessories, auxiliaries, complete in all respects as specified in the technical specification.
51Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/ (110/√3)V, One min power freq withstand 275KVrms GALVANISED TANK. Acc Class 0.2
52Galvanised Structures
53Galvanised Nuts and Bolts
542 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS ,galvanized steel wire/ strip armoured stranded copper conductor control cable complete
555 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
568 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS ,galvanized steel wire/ strip armoured stranded copper conductor control cable complete
5712 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
5816 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
5919 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
604 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS ,galvanized steel wire/ strip armoured stranded copper conductor control cable complete
6110 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
622 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
63Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self-supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly shoved. The paint thickness shall be at least 50 microns.
64400 sq mm ACSR ZEBRA,(a) Alumunium=54/3.18 mm(b) Steel=7/3.18 mm Overall dia 28.62mm.Approximate Wt 1621Kg/Km Ultimate breaking Load=130.32 KN
65Single Tension Fittings For Single Zebra shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN.
66Single Suspension Fittings For Single Zebra shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm.Minimum Ultimate strength (Tensile strength) shall be 70 KN.
67T Clamps Twin 0.4 / Twin 0.4, made of Alluminium Alloy and shall comply in all respects with IS:55611970 (latest edition
68P G Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
69Disc Insulators 70 KN,Ball& Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
70Disc Insulators 120 KN,Ball& Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected
717/3.15 mm G.I. Wire for ground conductor
72Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding conductivity of GSS ground wire
73Lugs, Ferrules, Welding Material, Cotton Waste etc
74Erection Testing and commissioning of Main Equipments and allied materials for Construction of 132KV line bay and conversion of existing line bay to transformer bay complete job
753 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 2500 Amps or higher, of 3 phase, 50 c/s and 40 KA for 1 second) along with supporting structures etc. complete in all Respects SS BODY,UNIVERSAL SPRING CHARGING MOTOR WITH MANDATORY SPARES
76145kV, 50c/s , 2500 A, SCADA Compatible, 40 KA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Switch. COPPER FIXED AND MOVING CONTACTS/ COPPER CURRENT CARRYING PARTS, GALVANISED IRON MECHANISM BOX.
77145kV, 50c/s , 2500 A, SCADA Compatible, 40 kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Switch. COPPER FIXED AND MOVING CONTACTS/ COPPER CURRENT CARRYING PARTS, GALVANISED IRON MECHANISM BOX
78Single phase, 50 c/s 145KV Current Transformers (600-300-150/1-1-1-1-1 A or 1200600-300/1-1-1-1-1A or 2000-1600-1200/1-1-1-11A or as per site specifications), 40 KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA 3 NO PS CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
79Neutral Current Transformer with Current Rating 1A/5A and VA Burden 15VA Ratio as per site specifications. 02 No PS class cores, 01 No 0.2s core, GALVANISED TANK 31.5KA for one second, rated dynamic current 31.5KA(peak), including first fill of transformer oil plus 20% extra and all accessories, auxiliaries Etc.
80Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor, class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
81132KV Control and Relay Panel for Transformer bay simplex/duplex as per requirement, completely wired including Substation automation supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER with IEC 61850 compatibility, including Differential Protection, Directional O/C & E/F Protection (on HV & LV side), numerical communicable REF protection relay, Over Fluxing Protection Local Breaker Backup (LBB) Protection separate relays for primary and backup protection
82132KV Post Insulators Solid Core Type/ Polymer Type, Power Frequency Withstand Voltage 275 KV RMS Dry lightning impulse withstand voltage ± 650 (KVP)
83Single phase, 50 c/s, 72.5 kV Current Transformers (1600-1200-800/1-1-1-1-1 A or 1200-800-400/1-1-1-1-1A or 2000-1600-1200/1-11-1-1 A or as per site specifications), 31.5 KA for one second, Class A insulation, Burden 20 VA 3 NO PS CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill of transformer oil plus 20% extra and all accessories, auxiliaries Etc. Complete in all respects
84Single phase, 50 c/s, outdoor, metal oxide gapless type, 60 kV (rms), class 3 arresters including surge counters / monitors, insulating base and all associated accessories, auxiliaries, complete in all respects as specified in the technical specification.
85Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/ (110/√3)V, One min power freq withstand 275KVrms GALVANISED TANK. Acc Class 0.2
86Galvanised Structures
87Galvanised Nuts and Bolts
882 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS ,galvanized steel wire/ strip armoured stranded copper conductor control cable complete
895 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
908 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS ,galvanized steel wire/ strip armoured stranded copper conductor control cable complete
9112 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
9216 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
9319 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
944 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS ,galvanized steel wire/ strip armoured stranded copper conductor control cable complete
9510 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
96Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanized steel wire/ strip armoured stranded copper conductor control cable complete
97Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self-supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly shoved. The paint thickness shall be at least 50 microns.
98400 sq mm ACSR ZEBRA,(a) Alumunium=54/3.18 mm(b) Steel=7/3.18 mm Overall dia 28.62mm.Approximate Wt 1621Kg/Km Ultimate breaking Load=130.32 KN
99Single Tension Fittings For Single Zebra shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN.
100Single Suspension Fittings For Single Zebra shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm.Minimum Ultimate strength (Tensile strength) shall be 70 KN.
101T Clamps Twin 0.4 / Twin 0.4, made of Alluminium Alloy and shall comply in all respects with IS:55611970 (latest edition
102P G Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
103Disc Insulators 70 KN,Ball& Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
104Disc Insulators 120 KN,Ball& Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected
1057/3.15 mm G.I. Wire for ground conductor
106Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding conductivity of GSS ground wire
107Conversion of 132KV line bay to transformer bay& Lugs, Ferrules, Welding Material, Cotton Waste etc
108Civil works for 132KV line bay and conversion of existing line bay to transformer bay
109Cable Ducts With Covers: Main Duct of Size 1200mm x 1200mm with 6 mm M.S Chequered Trench Covers of size 1300x500 mm
110Main Duct of Size 1200mm x 1200mm with 75mm Concrete Covers grade M15 of size 1300x500 mm M15 of size 1300x500 mm
111Sub Main Duct of Size 600mm x 600mm with 75mm Concrete Covers grade M15 of size 700x500 mm
112Tee off Duct: 150mm sand filled HDPE pipes from Sub main to Equipments in the outdoor area
113Earth Mat (40mm dia steel bars) as per approved design, Galavanised Iron (75mm x 12mm/ 50mm x 6 mm) risers for Equipment and Structural Earthing
114Concreting of yard & Laying Of Gravel
115Laying of 132KV Column foundations (as per Drawing)
116Laying of 132KV Isolator foundations (as per Drawing)
117Laying of 132KV SF6 Breaker foundations (as per Drawing)
118Laying of 132KV CT foundations (as per Drawing)
119Laying of 132KV NCT foundations (as per Drawing)
120Laying of 132KV LA foundations (as per Drawing)
121Laying of 132KV Post Insulator foundations (as per Drawing)
122Laying of 66KV CT foundations (as per Drawing)
123Laying of 66KV LA foundations (as per Drawing)
124CABLE TRAYS/CABLE RACKS/ACCESSORIES Cable Trays of size 400mm x 3000mm made of M.S angles 40x40x6mm,40x6 Flat.
125Cable Trays of size 300mm x 2500mm made of M.S angles 40x40x6mm,40x6 Flat.
126Supply of Main Equipments and allied materials for twinning of bus bar of 132KV and 66KV Yard with ACSR double moose conductor at Grid station Kathua
127500mm2 ACSR Moose (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
128Single Tension Fittings For Twin Moose shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN
129Single Suspension Fittings For Twin Moose shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm.Minimum Ultimate strength (Tensile strength) shall be 70 KN.
130T Clamps Twin 0.5 / Twin 0.5, made of Alluminium Alloy and shall comply in all respects with IS:55611970 (latest edition)
131Disc Insulators 120 KN,Ball& Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
132Disc Insulators 70 KN,Ball& Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
133Spacers for Twin ACSR Conductor
134P G Clamps 0.5 made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
135P I Clamps 0.5 made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
136Erection testing and commissioning of Main Equipments and allied materials for twinning of bus bar of 132KV and 66KV Yard with ACSR double moose conductor at Grid station Kathua
137500mm2 ACSR Moose (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
138Single Tension Fittings For Twin Moose shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN
139Single Suspension Fittings For Twin Moose shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm.Minimum Ultimate strength (Tensile strength) shall be 70 KN.
140Single Suspension Fittings For Twin Moose shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm.Minimum Ultimate strength (Tensile strength) shall be 70 KN.
141Disc Insulators 120 KN,Ball& Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
142Disc Insulators 70 KN,Ball& Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
143Spacers for Twin ACSR Conductor
144P G Clamps 0.5 made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
145P I Clamps 0.5 made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
146Supply of Battery bank and battery charger at grid Station Kathua
147Battery Bank 110 V, 300 AH, of 55 No. cells of 2 V each, sealed maintenance free VRLA type, High impact Polyprophelene copolymer container, flame retardant.
148Battery charger (Three phases): Battery charger as well as Automatic Regulators shall be of static type compatible with VRLA Batteries. Should also have necessary temperature sensors. Should have both Automatic and Manual control of output voltage and current. 110 V/30 A FC & 40 A FCBC 3 phase 4 wire for 300 AH VRLA Battery
149Erection testing and commissioning of Battery bank and battery charger at Grid Station Kathua
150Battery Bank 110 V, 300 AH, of 55 No. cells of 2 V each, sealed maintenance free VRLA type, High impact Polyprophelene copolymer container, flame retardant.
151Battery charger (Three phases): Battery charger as well as Automatic Regulators shall be of static type compatible with VRLA Batteries. Should also have necessary temperature sensors. Should have both Automatic and Manual control of output voltage and current. 110 V/30 A FC & 40 A FCBC 3 phase 4 wire for 300 AH VRLA Battery
152Supply of old obsolete AC and DC distribution boards at grid Station Kathua
153DC Distribution Panel (110V, DC) with 1 No.10Amp. Air break Circuit Double pole for battery incoming supply with DP MCBs & indicating Lamps etc.
154AC Distribution panel (415V,AC) complete with Circuit Breakers, indicating lamps etc for 132/66 KV Grid station Kathua
155100 KVA servo stabilizer 3-phase 4 wire copper wound indoor type, input voltage range 220-460V, output 400V ± 1%,in two parts of oil cooled and air voltage range 220-460V, output 400V ± 1%,in two parts of oil cooled and air cooled having, Digital control, Response time <10ms, Automatic Switch-Off against:• Under / Over-Voltage• Over-Load & Short - Circuit• Single Phasing, Class C Type Secondary surge Protection
156Power cables for AC/DC network in Control room for 132/66 KV Grid Station. The armoured XLPE insulated 1100 V grade power cables shall be of FRLS type, of category C1 conforming to IS: 7098 Part I (as amended up to date). The conductor shall be stranded aluminum, circular / shaped and compacted. In multi core cables, the core shall be identified by red, yellow, blue and black colored strips or coloring of insulation. A distinct inner sheath shall be provided in all multi core cables. For multi core cables the inner sheath shall be of extruded PVC of type ST-2 of IS: 5831. Armoring for single core cables shall be aluminum strips/wires. Outer sheath for all cables shall be extruded PVC of type ST- 2 of IS: 5831
157Erection testing and commissioning of old obsolete AC and DC distribution boards at grid Station Kathua
158DC Distribution Panel (110V, DC) with 1 No.10Amp. Air break Circuit Double pole for battery incoming supply with DP MCBs & indicating Lamps etc.
159AC Distribution panel (415V,AC) complete with Circuit Breakers, indicating lamps etc for 132/66 KV Grid station Kathua
160100 KVA servo stabilizer 3-phase 4 wire copper wound indoor type, input voltage range 220-460V, output 400V ± 1%,in two parts of oil cooled and air voltage range 220-460V, output 400V ± 1%,in two parts of oil cooled and air cooled having, Digital control, Response time <10ms, Automatic Switch-Off against:• Under / Over-Voltage• Over-Load & Short - Circuit• Single Phasing, Class C Type Secondary surge Protection
161Power cables for AC/DC network in Control room for 132/66 KV Grid Station. The armoured XLPE insulated 1100 V grade power cables shall be of FRLS type, of category C1 conforming to IS: 7098 Part I (as amended up to date). The conductor shall be stranded aluminum, circular / shaped and compacted. In multi core cables, the core shall be identified by red, yellow, blue and black colored strips or coloring of insulation. A distinct inner sheath shall be provided in all multi core cables. For multi core cables the inner sheath shall be of extruded PVC of type ST-2 of IS: 5831. Armoring for single core cables shall be aluminum strips/wires. Outer sheath for all cables shall be extruded PVC of type ST- 2 of IS: 5831
162Supply of 250KVA transformer for provision of alternate 11KV supply at 132/66KV grid Station Kathua
163Allied items of 11 KV Tapping Point
16411 KV XLPE Cable Single Circuit Three Core 120 sq.mm
165250 KVA,11/0.4 KV,3Ph LT Transformer ( Platform Mounted)
166Provision of Change Over Switch, 3.5 core 185mm2 LT cable, MCBs etc.
16711 KV Outdoor Heat Shrinkable Cable Termination Kits
168Erection testing and commissioning of 250KVA transformer for provision of alternate 11KV supply at 132/66KV grid Station Kathua
169Installation of 11 KV Tapping Point
170Erection of 11 KV XLPE Cable Single Circuit Three Core 120 sq.mm
171nstallation of 250 KVA,11/0.4 KV,3Ph LT Transformer ( Platform Mounted)
172Provision of Change Over Switch, 3.5 core 185mm2 LT cable, MCBs etc.
17311 KV Outdoor Heat Shrinkable Cable Termination Kits
174Supply of Marshaling Kiosk as per specifications
175(132 KV)/66KV Marshalling kiosk with Kiosk frames Stainless steel/HotDip Galvanised structural sections for pressed and shapedcold-rolled sheet steel, thickness not less than 2.0 mm.Shall be provided with a degree of protection of IP: 55,with Copper Bar earthing for 132 kV.as per specifications
176Erection Testing and commissioning of Marshaling Kiosk
177(132 KV) /66KV Marshalling kiosk with Kiosk frames Stainless steel/HotDip Galvanised structural sections for pressed and shapedcold-rolled sheet steel, thickness not less than 2.0 mm.Shall be provided with a degree of protection of IP: 55,with Copper Bar earthing for 132 kV.as per specifications
178Supply of Auxilliary transformer and allied materials
17966/0.433 KV, 1000 KVA , 3-Phase Transformer With Bimetallic Terminal connectors Energy Level-2 Copper Wound
180630 mm2 single core cable 1.1 KV Grade, Armoured, XLPE Insulated Stranded conductor FRLS type
18172.5 kV, 50 c/s, 1600 Amps, 31.5 kA for 3 second, AC Motor Operated horizontal double break, outdoor type isolators with all accessories including solid core post insulators, auxiliaries, marshalling boxes, other essentials, complete in all respects as specified in the technical specification mentioned in SBD( With one Earthing Blades)
182Post Insulators complete in all respects as specified in the technical specification mentioned in SBD( 70 KV)
183Single phase, 50 c/s, 72.5 kV Current Transformers (50-25-12.5/1-1-1 A or as per site specifications), 31.5 KA for one second, Class A insulation, Burden 20 VA 3 NO PS CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill of transformer oil plus 20% extra and all accessories, auxiliaries Etc. Complete in all respects
184Single phase, 50 c/s, outdoor, metal oxide gapless type, 60 kV (rms), class 3 arresters including surge counters / monitors, insulating base and all associated accessories, auxiliaries, complete in all respects as specified in the technical specification.
185Galvanised Structures
186Galvanised Nuts and Bolts
187Supply Erection Testing and commissioning of Auxilliary transformer
18866/0.433 KV, 1000 KVA , 3-Phase Transformer With Bimetallic Terminal connectors Energy Level-2 Copper Wound
189630 mm2 single core cable 1.1 KV Grade, Armoured, XLPE Insulated Stranded conductor FRLS type
19072.5 kV, 50 c/s, 1600 Amps, 31.5 kA for 3 second, AC Motor Operated horizontal double break, outdoor type isolators with all accessories including solid core post insulators, auxiliaries, marshalling boxes, other essentials, complete in all respects as specified in the technical specification mentioned in SBD( With one Earthing Blades)
191Post Insulators complete in all respects as specified in the technical specification mentioned in SBD( 70 KV)
192Single phase, 50 c/s, 72.5 kV Current Transformers (50-25-12.5/1-1-1 A or as per site specifications), 31.5 KA for one second, Class A insulation, Burden 20 VA 3 NO PS CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill of transformer oil plus 20% extra and all accessories, auxiliaries Etc. Complete in all respects
193Single phase, 50 c/s, outdoor, metal oxide gapless type, 60 kV (rms), class 3 arresters including surge counters / monitors, insulating base and all associated accessories, auxiliaries, complete in all respects as specified in the technical specification.
194Galvanised Structures
195Galvanised Nuts and Bolts
196Civil works for Aux. transformer
197Foundation plate form for Aux. Transformer (as per Drawing)
198Laying of 66KV Isolator foundations (as per Drawing)
199Laying of 66KV Post Insulator foundations (as per Drawing)
200Construction of Store Shed at Grid station Kathua
201Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:
202Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
203Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
204Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
205Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
206Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
207Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete 50 mm thick with 20mm nominal size stone aggregate.
208Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. welded
209Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter withbitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved urface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.50 mm thick with zinc coating not less than 275 gram/m2
210Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointedtogether at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters.
211Electrification of Shed
212Construction of Toitet at Grid station Kathua
213Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:
214Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
215Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
216Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts up to floor five level including curing but excluding cost of cantering shuttering, finishing and reinforcement. 1:1½:3 (1 cement: 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)) including providing and placing PVC pipes 100 mm dia for weep holes
217Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more.
218Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
219Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
220Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
221Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.
222Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.
223Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.of angle iron size 50x5x6
224Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.e.In colour such as White, Ivory, Grey, Fume Red Brown.
225Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
226Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws
227Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
228Painting of doors and windows with ready mixed synthetic enamel paint of approved brand and manufacture in all shades.
229Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps.
230Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
231Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 18.3.1 W.C. pan with ISI marked white solid plastic seat and lid.
232Providing and fixing brass bib cock of approved quality. 15 mm nominal bore
233Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
234Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
235Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia. 19.49.1 Circular type
236Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour
237Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall: 19.4.2.1 15 mm dia. nominal bore
238Providing and placing on terrace polyethylene water storage tank ISI:12701 marked indicating BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet ,outlet and overflow pipes but without fitting and the base support for tank (syntex,star,lotus or equivalent having valid ISI License.
239Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre
240Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Bend 87.5° 110 mm bend
241Carraige of material by MT at an average distance of 20 kms: Cement
242Aggregate
243Bricks
244Carraige of material by HL at an average distance of 100 mtr: Cement
245Aggregates
246Bricks
247Electrification of Toilet
248Extension of Control Room Grid Station Kathua
249Extension of control room as per specification of SBD (as per drawing)
250Dismantling of Existing Control room walls
251Bore well at GSS Kathua
252Deep drilling of bore hole 125 mm dia. as per the strata encountered including installation, testing and commissioningof M-II Hand Pump as per IS specifications by using ODEX method. The job includes extraction of MS Casing Pipe if any required during the drilling work and construction of platform as per site conditions.
253Providing of 125 mm dia. M.S. Casing Pipe. The 125mm dia. M.S. Casing Pipe ISI marked should have thickness of 5.4mm conforming to as per IS 4270/2001 medium class (Part-1) 2004 (Heavy C Class, weight per mtrs 18.11 kg) electric resistance welded beveled ended inside beed free pipes. Two coats of anti-corrosive paint. No circumferential weld.
254Providing, fitting,installation, testing and commissioning of Submersible,pump set along with Stand-By pump set (02-03 HP) & amp; LT 1.00 No. 210000 /No. 210,000.00 control panel.Includes Reputed make KSB,Crompton,Kirlosker,etc.). Lowering via HDPE Pipe, submersible cable, rope, clamp,nuts, bolts.Fabrication and fitting of well cap,tripod stand, chain block, and electrical connections.
255Supply of T&P Items
256Telescopic Ladder - Aluminum 6 m height
257Arc Welding machine electronic (9/10 KVA)
258Hand Drilling Machine
259Safety belt, minimum 2 m rope length along with scaffold hook - Class-A material suitable for EHV Transmission Line maintenance staff (PN56 & 351)(Double lanyard with padded straps and supports)
260Thermovision Camera low end
261Digital Earth resistance meter
262Tong tester/clamp meter AC/DC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56314428
AUTHORITY Government Departments
TENDER VALUE 15.22 Crore
LAST DATE 24-07-2026
Authority
Authority Name Power Development Department
Work Description Tender for Augmentation Of Gss Kathua From 3X50mva To 4X50mva By Way Of Supply Installation Testing and Commissioning of One 132/66Kv,50Mva Power Transformer With Allied Works, Construction Of New 132 Kv Line Bay, Conversion Of Existing Line Bay To Transformer Bay, Uprating Of Existing Twin Bus Bar From Acsr Zebra To Twin Moose Conductor At 66 Kv Yard,Extension Of Control Room Building, Supply Installation Testing and Commissioning of Battery Bank And Charger (300 Ah, 110V), Replacement Of Old And Obsolete Ac,Dc Board And 250 Kva Auxilliary Transformer At 132/66 Kv Grid Station Kathuaand Allied Works.
Basic Detail
Tender No TLMD-II/09 of 2026-27 dated 04-07-2026
Bidding Type Tender
Location
City Kathua
State Jammu and Kashmir
Key Dates
Publish Date 06 Jul 2026
Submission Date 24 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 15.22 Crore
Tender Fee 10000
EMD 30.44 Lakhs
Exemption Not Available
Document List
BOQ_1019044.xls
e4dae625-0433-40c4-b1de-dad6fb82ee39.html
Tendernotice_1.pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 24, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Jul 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days