Tender For Improvement And Augmentation Of Water Supply System By Way Of Creation Of Manifold, Upliftment Of Valves And Plugging Of Leakage At 20000 Gallons Oht Logate Near Railway Line Under District Capex
Tender Value
5.20 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
1 days left
EMD
10400
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kathua → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Improvement And Augmentation Of Water Supply System By Way Of Creation Of Manifold, Upliftment Of Valves And Plugging Of Leakage At 20000 Gallons Oht Logate Near Railway Line Under District Capex
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavatedearth as directed:All kinds of soil. |
| 2 | Providing and laying in position cement concrete of 1:4:8 mix (1 cement 4 coarse sand 8 graded stone agg. 40 mm nominal size) excl. cost of centring and shuttering all work up to plinth level (using crushed stone agg.) |
| 3 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate |
| 4 | Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled &honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 23.23.1 For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level in 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) (using crushed stone agg.) |
| 6 | Finishing walls with water proofing cement paint of required shade on new work (two or more coats) applied @ 3.84 Kg/10 Sqm |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 8 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge : Above 40 mm nominal bore |
| 9 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc.100mmφ(L) |
| 10 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc.80mmφ(L) |
| 11 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc.65mmφ |
| 12 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc.40 mmφ |
| 13 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc.32 mmφ |
| 14 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc.25 mmφ |
| 15 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc.20 mmφ |
| 16 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc.15 mmφ |
| 17 | Laying and fitting of G.I. pipes (all classes) complete excluding cost of pipes, fittings and Earth work.80 mm dia (m) |
| 18 | Laying and fitting of G.I. pipes (all classes) complete excluding cost of pipes, fittings and Earth work. 65 mm dia (m) |
| 19 | Laying and fitting of G.I. pipes (all classes) complete excluding cost of pipes, fittings and Earth work. 40 |
| 20 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)40 MMDIA |
| 21 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 MMDIA |
| 22 | Lettering with black Japan paint of approved brand and manufacture. |
| 23 | Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately)80mm dia |
| 24 | Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately)65mm dia |
| 25 | Welding of joints by electric arc welding including, testing and commissioning of joints including carriage of set and all other accessories including making arrangement for electric supply/arrangement for Generator etc complete |
| 26 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 27 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup andlock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration asapproved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured fr payment purpose. The payment will bemade once irrespective of duration of scaffolding Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayJul 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender