Tender For Repair/Replacement /Cleaning Of Sewage Line, Manholes, Wc Pan, Gully Traps And Pipes In Sewage Ducts Etc In Area-Ii Of Age (B/R) Central Under Ge (West) Colaba, Mumbai
Tender Value
50 Lakhs
Estimated cost
Bid Submission
25 Jul 2026
17 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement /Cleaning Of Sewage Line, Manholes, Wc Pan, Gully Traps And Pipes In Sewage Ducts Etc In Area-Ii Of Age (B/R) Central Under Ge (West) Colaba, Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | Material & Labour for attending complaints for cleaning of all blockages of nahni trap/floor trap, bottle traps, gully traps, P or S traps of WCs, 100mm / 75 mm CI pipes and stacks up to Ist manhole, CI/SGSW pipes between gully trap and first manhole, CI Tee/door bends, sewage lines of any dia and depth including opening of cover slabs and and recovering after completion, by passing/rodding ropes, knots, bamboo/ wire/ kandi, rotary cleaning rods or with mechanical process, and removal of sludge/ mud/dry silt etc. in foul position to outside defence land etc between two manholes to maintain internal sewage system on all working days from 0900 Hrs to 1700 Hrs in the area II of AGE B/R Central with manual / pressure cleaning pumps & flexible roads and other necessary equipments, complete all as specified and directed. |
| 2 | Material & Labour for attending complaints for cleaning of all blockages of nahni trap/floor trap, bottle traps, gully traps, P or S traps of WCs,100mm / 75 mm CI pipes and stacks up to Ist manhole, CI/SGSW pipes between gully trap and first manhole, CI Tee/door bends, sewage lines of any dia and depth including opening of cover slabs and and recovering after completion, by passing/rodding ropes, knots, bamboo/ wire/ kandi, rotary cleaning rods or with mechanical process, and removal of sludge/ mud/dry silt etc. in foul position to outside defence land etc between two manholes to maintain internal sewage system from 0900 Hrs to 1700 Hrs in the area II of AGE B/R Central with manual/ pressure cleaning pumps & flexible roads and other necessary equipments but on emergency basis on Sunday/ closed holiday/Gazetted holidays on call of Engr-in-charge/JE, complete all as specified and directed. |
| 3 | M&L for cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for any width of drains and depth of drains n.exc 0.45m, complete all as specified and directed. |
| 4 | Cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers and completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for any width of drains and depth exc 45 cm but n.exc 90 cm, complete all as specified and directed. |
| 5 | Demolition brickwork or stone/boulder masonry, build incement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 6 | Material and labour for brick work with sub class 'B' brick straight curved on plan exceeding 6 metre mean radius with old size bricks built in CM 1:6 of manholes,septic tank, soak pits etc, complete all as specified and directed. |
| 7 | Taking down cement plaster from inside/outside of existing septic tank/manhole/walls etc including racking out joints, hacking for key scrubbing down with water and removal of rubbish off the premises, complete all as specified and directed. |
| 8 | Material & Labour for 15 mm thick rendering in cement mortar 1:4 mixed with liquid waterproofing admixture as per manufactures instructions inside and outside wall of manhole of brick work/ concrete surface and finishing fair and even inside and even and smooth inside without using extra cement mortar as per manufactures instructions, complete all as specified and directed.Note: (i) WPC shall be measured and paid for separately as 'Supply only'.(ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction. |
| 9 | Supply only integral water proofing, complete all as specified and directed. |
| 10 | Firstly old loose spelled concrete should be chiseled from roof ceiling with the help of scrapers chisel & hammer after that cleaning of rust from mild steel rod and applying cement spry 3.00 Kg per sqm by paint brush over cleaned surfaces and Material and Labour for 12-15 mm thick ready mix plaster in Multi layer for ceiling on fair faces of brick wall or concrete surfaces, finished even and fair Including three coat white wash, complete all as specified and directed by Engr-in-charge. |
| 11 | Dismantling wrought iron or mild steel of any description not othervise specifically provided for, complete all as specified and directed. |
| 12 | M & L for framed work such as grills, gratings, manhole/drain covers etc.with end of bars shouldered and/or rivetted, framed guard bars and similar works conforming to Fe-290, Gde- E 165, complete all as specified and directed. |
| 13 | M & L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment as in manhole or drain cover and similar works conforming to Fe-410, Gde-E 250, complete all as specified and directed by Engr -in- charge. |
| 14 | Material & Labour for preparation of new surfaces of steel and iron work of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 15 | Material & Labour for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth and applying one coats of synthetic enamel paint, complete all as specified and directed. |
| 16 | M&L preparing old painted brick or conc surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of floor coat emulsion paint, complete all as specified and directed. |
| 17 | Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B-1, smooth finished and reforming benching as required for internal pipe of dia 150 mm, complete all as specified and directed. |
| 18 | Demolition, breaking and removing from underground trenches/ wall/ floor, drain pipe (SGSW/RCC etc) set in cement mortar of internal dia 150 mm including demolition of surrounding concrete hauching and bedding, complete all as specified and directed. |
| 19 | Demolition, breaking and removing from underground trenches/ wall/floor, drain pipe (SGSW/RCC etc) set in cement mortar of internal dia 200 mm including demolition of surrounding concrete hauching and bedding, complete all as specified and directed. |
| 20 | Demolition, breaking and removing from underground trenches/ wall/floor, drain pipe (SGSW/RCC etc) set in cement mortar of internal dia 300 mm including demolition of surrounding concrete hauching and bedding, complete all as specified and directed. |
| 21 | Material & Labour for PCC 1:3:6 type C-2, (using 40 mm graded aggragate) as in concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes after pipe laid and tested, complete all as specified and directed. |
| 22 | Material & Labour for 150 mm bore (internal dia of pipe) reinforced concrete pipes, Class NP-2 laid in trenches and jointed with Cement mortar (1:1), complete all as specified and directed. |
| 23 | Material & Labour for PCC 1:3:6 type C-2, (using 40 mm graded aggragate) as in concrete bed to 200 mm bore drain pipe including packing under and haunching against the sides of pipes after pipe laid and tested, complete all as specified and directed. |
| 24 | Material & Labour for 200 mm bore (internal dia of pipe) reinforced concrete pipes, Class NP-2 laid in trenches and jointed with Cement mortar (1:1), complete all as specified and directed. |
| 25 | Material & Labour for PCC 1:3:6 type C-2, (using 40 mm graded aggragate) as in concrete bed to 300 mm bore drain pipe including packing under and haunching against the sides of pipes after pipe laid and tested, complete all as specified and directed. |
| 26 | Material & Labour for 300 mm bore (internal dia of pipe) reinforced concrete pipes, Class NP-3 laid in trenches and jointed with Cement mortar (1:1), complete all as specified and directed. |
| 27 | Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position, complete all as specified and directed. |
| 28 | Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil, complete all as specified and directed. |
| 29 | Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed. |
| 30 | Demoletion of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided, complete all as specified and directed. |
| 31 | S&F in repair Factory made precast RCC drain cover of size 900 x 600mm / 600 x 450mm and fixed to drain in CM (1:4), complete all as specified and directed. |
| 32 | S&F Factory made precast (SFRC) Cover slab, Squre/ rectangular/ circular in shape and size as required of medium duty of 75 mm thickness ISI marked with load carrying capacity of 5T/Sqm, complete all as specified and directed. |
| 33 | Dismantling of PVC pipe of any dia with fitting, complete all as specified and directed. |
| 34 | Supply & Fixing for 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls, complete all as specified and directed. |
| 35 | Supply & Fixing for 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls, complete all as specified and directed. |
| 36 | S & F PVC (SWR) gully trap in repair 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed. |
| 37 | Supply & Fixing for 75mm dia PVC (SWR) bends, complete all as specified and directed. |
| 38 | Supply & Fixing for 110 mm dia PVC (SWR) bends, complete all as specified and directed. |
| 39 | Supply & Fixing for 75 mm dia PVC (SWR) junction single, (single T) equal or unequal provided, complete all as specified and directed. |
| 40 | Supply & Fixing for 110 mm dia PVC (SWR) junction single, (single T) equal or unequal provided, complete all as specified and directed. |
| 41 | Supply & Fixing for 75 mm dia PVC (SWR) vent cowl, complete all as specified and directed. |
| 42 | S&F for PVC (SWR) reducers, 110 mm bore, complete all as specified and directed. |
| 43 | S&F for PVC (SWR) reducers, 75 mm bore, complete all as specified and directed. |
| 44 | S&F for PVC (SWR) branch piece, single (single Y) equal or unequal radius, 110 mm bore, complete all as specified and directed. |
| 45 | S&F for PVC (SWR) branch piece, single (single Y) equal or unequal radius, 75 mm bore, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 46 | S&F for PVC (SWR) branch piece, single (single Y) equal or unequal radius, 75 mm bore, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender