Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56303875

Tender For Provision Of 100 Kva Sub Station At Nfs Node At Anantnag High Ground Under Ge 861 Ews

Issued by Statutory Bodies & Commissions/Committees · Sabarkantha, Gujarat
Tender Value
33.81 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
20 days left
EMD
67636
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sabarkantha → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of 100 Kva Sub Station At Nfs Node At Anantnag High Ground Under Ge 861 Ews

BOQ

Name of Work:- PROVISION OF 100 KVA SUB STATION AT NFS NODE AT ANANTNAG HIGH GROUND UNDER GE 861 EWS
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation of poles/stay/cable etc and getting out in Hard/dense soil complete all as specified and directed.
2Description all as above item Ser No 01 but for soft /disintegrated rock complete all as specified and directed
3Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m deep for foundation of poles/stay/cable etc including getting out in hard/dense of soil complete all as specified and directed.
4Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
5Removing surplus excavated material/surplus soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
6Supplying and laying unreinforced precast concrete cable cover, Class HVP, type 2 with peak, size 450mm x 180mm x 40mm, complete all as specified and directed.
7M&L washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling and hard punning complete all as specified and directed.
8M&L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed.
9Supply and fixing GI tubing, 80 mm bore, light grade with all fittings/clamps of suitable size and nuts and bolts, including one coat of red oxide primer and painting two coats of synthetic enamal paint complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed.
10Supply and fixing GI tubing, 100 mm bore, light grade with all fittings/clamps of suitable size and nuts and bolts, including one coat of red oxide primer and painting two coats of synthetic enamal paint complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed.
11Supply, laying, commissioning, testing of XLPE under ground HT cable 11000 volts grade (Earthed) of size 95 Sqmm 3 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall with the help of clamp, under road crossing through protection pipe etc complete all as specified and directed.
12Supply, laying, commissioning and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed.
13Supply and fixing cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and directed.
14Supply and fixing cable jointing kit for 11 KV grade cable for Straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and directed.
15Supply & errect Steel tubular swaged pole complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP -55 11 Meter Long Galvanised steel tubular/hexagonal pole Each consisting of pole with anti climbing device. including painting of pole with one coat of primer and applying two coats of aluminium paint and painting strips 30 cm wide with Black and yellow colour alternate up to 1.5 from bottom complete all as specified and directed.
16Supply, fixing and testing gang operated air breaker switch , triple pole , mechanically operated mounted on isulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe for current rating 200 Amps, out door type ( confirming to IS specifications) HT 11 KV, tripple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, 12 insulators type mounted on MS channel operating rod with pad lock arrangement complete all as specified and directed.
17S&F disc type insulator, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts including taking down old unserviceable complete all as specified and directed.
18S&F Pin type, porcelain, vitreous, white, brown or green insulator including one Each galvanised old steel spindle, two galvanished iron washers and one galvanised iron nut. 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
19S&F Shackle type, Porcelain, vitreous, white, brown or green insulator 11000 Volts height 150 mm, max dia 150 mm with galvanised mild steel straps of 38 x 5 mm and dia of bolt 20 mm including washers and nuts complete all fixing arrangement all as specified and directed.
20M&L Aluminum conductor steel reinforced any type complete all as specified and directed.
21S&F Galvanised steel wire 3.15 or 4 mm dia complete all as specified and directed.
22M&L Stay assembly complete with accessories as shown in electrical plate No 1 with stay rod of 20 mm dia (loop type insulator, stay clamps excavation and concrete shall be measured separately) complete all as specified and directed.
23S&F loop type insulator, vitreous procelain , white, brown large size with overall dimensions 90mm x 140 mm clearance of hole 25.5 mm complete all as specified and directed.
24S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
25S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
26S&F lightning arrestors expulsion type complete with all fittings, suitable for volts 11000V and discharge capacity 65 Kilo Amps complete all as specified and directed.
27M&L earthing complete with galvanised earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level earth plate connected with GI strip of size 32x6mm by means of lugs, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 40mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to panel, including excavation, earth work, salt and charcoal dust mixed, GI pipe medium grade 20mm nominal bore for watering, funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 with suitable lifting handle and pit/chamber in PCC 1:3:6 type CI, including testing on completion complete all as specified and directed.
28M&L earthing complete with galvanised earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level earth plate connected with GI wire 4 mm dia by means of lugs, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 20 mm bore light grade upto7.5 mtrs all as shown in elect plate No.3 of SSR part I connecting to panel, including excavation, earth work, salt and charcoal dust mixed, GI pipe medium grade 20mm nominal bore for watering, funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 with suitable lifting handle and pit/chamber in PCC 1:3:6 type CI, including testing on completion complete all as specified and directed.
29Supply, installation, testing and commissioning of CPRI approved LT distribution panel outdoor type of suitable size weather/vermin proof, made out of 3.15mm thick CRCA sheet duly powder coated, mounted on 65x65x6mm (ISA6565) iron angles frame of hight 45 cm from PCC bedding, factory assembled compartmentalized construction, free standing type, including 3 phase and neutral 300 amps current carrying capacity bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting bus bar connection/linkage complete and conforming to IS 8623 and IP 54 class of protection as per IS 2147 complete, including making connection of cables of incoming and outgoing with thimble/lugs, including the accessories as below complete and mountig the panel on ground/floor with PCC(1:3:6) bedding upto a height of 30 cm above ground level and 30 cm in foundation complete all as specified and directed directed.(a) Aluminium bus bar 300 amps for 3 phase & neutral -1 set(b) MCCB 4 Pole 200 Amps 35 KA -01 no(incoming)(c) MCCB 4 Pole, 63 Amps 16 KA - 02 Nos (outgoing)(d) MCB 4 Pole, 32 Amps -02 Nos (outgoing)(e) LED type Phase Indicator with controlling fuses for RYB-01 set(f) 3 P multi function energy energy meter 1-125A and energy (voltage 0-500 volt ampere consumption in KWH including CT's and PT's)
30Supply, installation, testing and commissioning of CPRI approved LT distribution panel outdoor type of suitable size weather/vermin proof, made out of 3.15mm thick CRCA sheet duly powder coated, mounted on 65x65x6mm (ISA6565) iron angles frame of hight 45 cm from PCC bedding, factory assembled compartmentalized construction, free standing type, including 3 phase and neutral 300 amps current carrying capacity bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting bus bar connection/linkage complete and conforming to IS 8623 and IP 54 class of protection as per IS 2147 complete, including making connection of cables of incoming and outgoing with thimble/lugs, including the accessories as below complete and mountig the panel on ground/floor with PCC(1:3:6) bedding upto a height of 30 cm above ground level and 30 cm in foundation complete all as specified and directed directed.(a) Aluminium bus bar 100 amps for 3 phase & neutral -1 set(b) MCCB 4 Pole 200 Amps 35 KA -01 no (incoming)(c)MCCB 4 Pole, 32 Amps 16KA -0 2 Nos (outgoing)(d) LED type Phase Indicator with controlling fuses for RYB-01 set
31M&L loose filling and spread with broken stone aggregate of gauge 40 to 80 mm complete all as specified and directed.
32Supply and Spreading in area graded coarse aggregate of size 20 mm complete all as specified and directed.
33Tools and labour required for trimming of tree branches required for installation of Overhead HT line and clearing the open space not less than 5 metre both sides from over head conductor and sub stn area complete as required on site to installation of over head stratiching OH line complete all as specified and directed.Note : Complete site for OH HT line shall be cleared for further execution of work and nothing extra amount shall be paid .
34M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) (using 40 mm graded crushed stone aggregate) complete all as specified and directed.
35M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) (using 40 mm graded crushed stone aggregate) complete all as specified and directed.
36M&L PCC 1:2:4 , type B-1 (using 20mm graded crushed stone aggregate) in walls, retaining walls, coping complete all as specified and directed.
37Supply, installation, testing and commissioning of highly energy efficient, out door type oil immersed naturally cooled (ONAN) transformer, copper wound type of capacity 100 KVA as per latest IS code/specification conforming to IS-1180, Level-III with off laod tap changover on primary side to vary secondary voltage within limit (+) 5% to (-) 7.5% in step to 2.5% including standard fittings and first filling to transformer oil as per IS-335 of 1980 with cooling system. The transformer shall be provided with cable termination box to terminate outdoor type termination of suitable size on HT side 11 KV & LT side 1100 volt. Transformer step down ratio 11000 volts/433 volts, 3 phase , 4 wire impedance as per oil type, ONAM cooled suitable for outdoor installations and double wound core type with cold rolled grain oriented silicon shell insulated laminations and clamped to minimize vibration for full load current and with stand the thermal and electromagnetic stresses arising due to the through fault current vector group shall be DYN 11 including supply of all standard fittings/fixtures and comprising of the following and all specified and direced. (a) HT cable termination box.(b) LT cable termination box.(c) Rating and diaphragam plate(d) Earthing terminal(e) Lifting lugs(f) Oil level indicator with minimum level marking.(g) Thermometer bocket.(h) Conventional conservator with oil filling hole with cap and drain cum sampling valve.(j) Air release plug.(k) Silica gel breather.(l) Off circuit tap changer with locking provision.(m) Bi-directional rollers.(n) Jacking pads.(o) Radiators/Fins and all (Epoxy painted).(p) Danger notice board.
38M&L plinth for transformer of size 3m x 3m x 1 m above ground level and 0.30 m in foundation, including excavation in for foundation, including brick work with sub class B bricks, pcc work, earth filling work, plastring work etc for placing of transformer complete all as specified and directed.
39Excavating in post holes (or similar holes) each not exceeding 0.5 cum getting out returning, filling and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm out in any type of soil complete all as specified and directed.
40S&F hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars for doors, balusters, nosing to steps including embedding in concrete and screwing etc wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching or wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 grade E-165 complete all as specified and directed.
41S&F mild steel screw bolts (machine made) with hexagonal or square heads 11 to 15 mm dia at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut not exceeding 5 cm long complete all as specified and directed.
42S&F TMT steel bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe-410W (grade E-250) quality A or Fe-290 (Grade E-165) complete all as specified and directed.
43Fixing only chain link fencing including line wires any mesh size and type to any type of standard, rails, straining bolts etc including provisions of binding wire complete all as specified and directed.
44Supply only chain link MS galvanised fencing any size or type complete all as specified and directed.
45S&F galvanised s strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured) complete all as specified and directed.
46S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and directed.
47M&L preparation of newly steel surface of any description over 10 cm in width and girth nor otherwise described with two coats of synthetic enamel (ordinary tint) (each coat) over a coat of red oxide zinc chrome primer complete all as specified and directed.
48M&L preparation of newly steel surfaces of any description not exceeding 10 cm in width and girth when unconnected with other painting or when painted in a different tint using two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56303875
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 33.81 Lakhs
LAST DATE 29-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of 100 Kva Sub Station At Nfs Node At Anantnag High Ground Under Ge 861 Ews
Basic Detail
Tender No 134WE-35(T)/2026-27
Bidding Type Tender
Location
City Sabarkantha
State Gujarat
Key Dates
Publish Date 04 Jul 2026
Submission Date 29 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value 33.81 Lakhs
Tender Fee 500
EMD 67636
Exemption Not Available
Document List
67310bef-d1ae-4b98-8349-fd6c234a2085.html
BOQ_869515.xls
PS35.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

67310bef-d1ae-4b98-8349-fd6c234a2085.html

xls

BOQ_869515.xls

pdf

PS35.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender