Tender For Provision Of 03 X High Mast Light Unit Location Of Demo Bn Under Ge (Awc) Mhow
Tender Value
25.24 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
22 days left
EMD
50500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of 03 X High Mast Light Unit Location Of Demo Bn Under Ge (Awc) Mhow
BOQ
| Sl. No. | Item Description |
| 1 | Supply, install, testing and commissioning of 20 Mtr motorised High mast shaft in two sections, internally and externally hot dip galvanised with average 70 microns, designed for 50M/Sec wind speed, comprising of raising and lowering system, 6mm dia stainless steel wire ropes 3 no for Lantern carriage and 2 no for winch, head frame, double drum winch with luminaire mounting arm, lantern carriage suitable to install 9 to 12 Nos luminaires in symmetrical arrangement, trailing cable 1100 volts grade ISI marked multistranded copper conductor cable 6 core 2.5 sq mm, connector, integral power tool suitable for handling the total head load, , pully assembly, LED aviation obstruction light, lightning arrester spike including necessary foundation with RCC M-25 grade concrete for high mast considering the safe soil bearing capacity at site as 10T/sqm at 2 metre depth as per manufacture's design complete all as specified and as directed. |
| 2 | Supply & Fixing of Led Flood Light fitting 200 Watt having efficacy >120 lm/w system output of minimum 48000 lumens,THD< 10% PF>.95 CRI >70 CCT 5700-6400k With IP 66 protection single piece die cast aluminium housing having pc with IK 08 luminaries. Led driver should be potted and Encapsuled.Surge protection should 4kv and 10 kv external SPD housed in luminaries. LM 79 and LM 80 report submitted at the time of product approval And only well reputed LED chip make install in fixture Cree,Osram,Brdgelox,Nexon etc complete all as specified and directed. |
| 3 | Supply Installation & Commissioning of outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals, mounted on suitable foundation complete all as specified and as directed. |
| 4 | Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation ,laying of cable or pipe (wherever provided for protection of cable or fixing poles) and stay and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 6 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 7 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed. |
| 8 | Supply and laying fine sand for cable protection in layers incl punning complete all as specified and as directed.Note :- Punned thickness shall be measured for the payment. |
| 9 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core in trenches / under PCC/interlocking tiles incl making good of surface with PCC/ cementing incl connecting to existing LT panel board and VTPN DBs complete all as specifed and directed. |
| 10 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core in trenches / under PCC/interlocking tiles incl making good of surface with PCC/ cementing incl connecting to existing LT panel board/ OH Lines and VTPN DBscomplete all as specifed and directed. |
| 11 | M&L for Tubes, 'light grade,galvanised, with all fitting of size 50 mm ;laid in trenches or fixed in wll with saddles for cable protection/ mounting security lights incl bending and cutting to required length complete all as specifed and directed. |
| 12 | M&L for providing under ground boring using mechanical pneumatic drilling equipment / manually for passing electric cables through by providing HDPE pipe of 100mm dia heavy quality, pressure rating 6 kg/cm2 under the existing bituminous/WBM road/PCC hard standings, depth range not more than 1.5mtr deep and making good the distrubed surfaces is to match with its existing specifications all as specified and directed.Note : Any damage to the existing cables/water pipes/structures shall be made good by the contractor at his own expense. |
| 13 | Supply , fix , test & commissioning in replacement of LT weather proof panel board powder coated out door type double door shutter type made out of CRCA sheet 3.15 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar of cap 200 Amp with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc.The bottom portion of enclosure shall be minimum 30 cm above ground level of legs of angle iron ) Consisting of following accessories :- a) Aluminium bus bar capacity 200 Amps for Phase-R-Y-B-3 Nos & 200 Amps for neutral -1 No . Neutral link-01 Nob) MCCB TPN 25 KA, 160 Amp - 1 No (I/C) c) MCCB TPN 25 KA, 100 Amp-01 No (O/G) d) MCB TPN 63 Amps- 02 Nos (O/G) (e) MCB SP 20 Amps -06 Nos( O/G) |
| 14 | Supply and fix in repair of automatic street light switch using infrared sensor based on nature switch and voltage monitoring system (VMS) series for automatic switching of street lights. Nature switch operation should be based on nature light lux level. Required illumination level for switching ON is <30 lux and for switching OFF >10 lux.VMS should have adjustable over & under voltage trip level and protection against phase loss, neutral loss & phase reverse. The nature switch along with suitable power contactors , incoming and outgoing MCBs should be enclosed in a pole/ wall mountable enclosure made of rust proof , electric shock proof and FR grade SMC junction box with hinged lid confirming to IP 54 complete all as specified for the following: -a) Suitable of three phase load of 8-12 kw with contactors (single phase 3Nos), incoming& OutgoingMCB SP (6 Nos),rating of 32 Amps per phase & circuit wiring of min 10 sqmm. |
| 15 | Material and labour for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 Metre below normal ground level connected to galvanised strip 32 x 6 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 use 20 mm graded stone aggregate chamber including necessary formwork / mould for fair and even surfaces, precast RCC 1:2:4 type B0 use 12.5 mm graded stone aggregate chamber cover slab, GI funnel, with GI watering pipe 20 mm bore medium graded, wire mesh, protection pipe 40 mm bore GI pipe light grade for earth lead upto 7.50 metre long salt, charcoal including testing complete all as specified and directed by Engineer-in-Charge. Note : (i) GI strip beyond 7.5 metre will be measured and paid sepeartely. (ii) Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & user. (iii) The earth resistance should be less than 5 Ohm. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender