Tender For Repair/ Maintenance Of Street Light, High Mast Light, Ug Cables, Oh Lines, Junction Boxes, Nature Switches And Connected Items At anganwadi center And C Area, Sarna Enclave, Vindhya Vihar, Demo Sqn, Goswami Enclave, Amn Dumps, Ace, Eme Wks
Tender Overview
Project Description
Tender for Repair/ Maintenance Of Street Light, High Mast Light, Ug Cables, Oh Lines, Junction Boxes, Nature Switches And Connected Items At anganwadi center And C Area, Sarna Enclave, Vindhya Vihar, Demo Sqn, Goswami Enclave, Amn Dumps, Ace, Eme Wksp, 11 Jak Li, Supply Depot, Demo Bty And Mes Colonies Under Ge (Awc) Mhow
BOQ
| Sl. No. | Item Description |
| 1 | Repair/Renewal/maintenance of street light feeder (over head conductors) after arranging elect shut down of street light feeders from sub station to remove oxidise part at the point of connection to street light from LT over head line and reconnect the same to LT over head line after removing the oxidise part all as specified and directed by Engr-in-charge . Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safety devices. |
| 2 | Attending complaint & Checking of street light feeder (under ground cables) from Junction box to fittings using elect tools, equipments and safety devices after arranging elect shut down of street light feeders from sub station to remove elect faults like tightning of loose jumpers, trimming of tree branches on a particular span, re-tightning of binding wires on insulators, re-tightning of cable lugs etc all as required at site and as directed. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safety devices.(ii) Materials like cables used for rectification of faults like will be measured and paid seperately. |
| 3 | M&L for Repair of Unsv street/security lights, flood lights , post top lanterns or any other external lights by taking down to ground, testing all the components/parts, wiring etc, identifying and replacing the defective components like choke (ballast), electronic driver (in case of LED Lights), ignitor, capacitor, lamp, lamp holder, connector, connection wires/ cable, MCB etc including refixing the fitting to its original position (if taken down), including repair/maint of street light control timer & junction box all as directed by Engr-in-charge for the complete contract period from the date of commencement of work. |
| 4 | Note:- (i) The rate against above mentioned item is deemed for cost of labour and minor spare parts. LED Driver if replaced will be measured & paid separately.(ii) The contractors representative will report to concerned JE E/M at 0900 hrs daily to collect the list of defective street light fittings and will submit the completion report on the same day before 1730hrs to JE E/M.(iii) The contractor has to rectify the defects/ repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him/his rep by the concerned JE E/M. In case the street light is not made funtional for whatsoever reason within the specified time limit, an amount of Rs. 150/- per such defective street light per day will be recovered from the amount due to him through RAR/Final Bill.(iv) Contractor shall arrange requisite and sufficient no transport and vehicle mounted hydraulic ladder at his own.(v) The contracor shall maintain proper record of repair/maint in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every monday or as and when askded for.(vi) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipment and clothings to his men and department shall not be repsonsible for any kind of mishap/accident/injury to his men. (vii) The contractor shall maintain sufficient stock of spares/material required for repair/maint of street lights with the concerned JE E./M against the supply only items here-in-below, required screws, insulating tapes, internal wiring wire, gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged and supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contrator under this item. |
| 5 | Description all as per ser item no. 3.00 & 3.01 above but for light fittings from Mini- mast Lights poles of 11 to 13 m long. |
| 6 | Taking down high mast fitting from high mast structure through motorised system of 16/20mtr high and checking all fittings including cleaning & lubricating of steel rope and repair the light fittings to make functional by replacing accessories like choke, ignitor, lamp holder etc as required. Note:- Accessories like choke, ignitor, lamp, capacitor, holder, connecting cable will be measured and paid for seperately under respective item of this BOQ. |
| 7 | Supply and fixing in replacement for LED flood light 120 watt 230 V AC outdoor type with high pressure die-cast aluminium housing and toughened glass in frant with unique flood optics to ensure uniform distribution with system efficacy more than 120 lm/watt, thermal management in multiple optics and equipped with IP66, IK10 protection with impact and corrosion resistant complete with driver and lamp all as specified. |
| 8 | Supply and fixing in replacement for LED flood light 150 watt 230 V AC outdoor type with high pressure die-cast aluminium housing and toughened glass in front with unique flood optics to ensure uniform distribution with system efficacy more than 120 lm/watt, thermal management in multiple optics and equipped with IP66, IK10 protection with impact and corrosion resistant complete with driver and lamp all as specified & directed. |
| 9 | Supply and fixing in replacement for LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with PC cover in front and lens for batwing light disttribution with system efficacy more than 140 lm/watt with IP 66, IK10 protection complete all as specified & directed. |
| 10 | Supply and fixing in replacement for LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with PC cover in front and lens for batwing light disttribution with system efficacy more than 140 lm/watt with IP 66, IK10 protection complete all as specified & directed. |
| 11 | Supply and fixing in replacement for post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 12 | Supply and fixing in replacement moulding compound Street light junction box of size 250 mm x 200 mm x 105mm complete with shock and rust proof, termite resistant, tamper proof , front openable type and including suitable provision for 3 phase 4 core incomming & outgoing loop -in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete. |
| 13 | Repair/Renewal/maintenance of junction box/control box of street light by disconnecting all connection and reconnect the same after dusting, proper insulation by LT tape, replacement of Lugs, nut, bolt ,wisher if required , Replacement of MCB 06 Amp if required and ensure the junction box must be closed all as specified and directed by Engr-in-charge. |
| 14 | S&F for LED driver for FLOOD LIGHT of capacity 150 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge. |
| 15 | S&F for LED driver for FLOOD LIGHT of capacity 120 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge. |
| 16 | S&F for LED driver for FLOOD LIGHT of capacity 80/100 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge. |
| 17 | S&F for LED driver for Street Lights,of capacity 60/70/90 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge . |
| 18 | S&F for LED driver for Street Lights,of capacity 30/36/45 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge . |
| 19 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm complete all as specifed and directed. |
| 20 | Supply and Fix, Two core PVC insulated copper cable with multistranded copper condutor of size 1.0 sqmm x two core, and drawing in to PVC Conduits & GI pipe bracket and connect to street light fittings complete all as specified and directed. |
| 21 | M&L for street light bracket made out of 40mm dia medium grade GI pipe of not more than 1.2m length, bent to required shape suitable for fixing street light / security light fitting on Steel tubular pole / RCC pole / building wall including two Nos clamps made out 30mm X 5mm flat with suitable nuts and bolts (clamp type - as per site requirement ) including two coats of aluminium paint over a coating of red oxide primer and complete all as directed. |
| 22 | M & L for Painting to street light pole of steel tubular swaged/ swan neck type with two coat of aluminium paint after cleaning to rusted portion of pole and finishing the surfaces including one coat primer top to bottom, painting on cross arms/FI clamps/street light brackets of any type including making alternative black and yellow strip with synthethic enemelled paint up to 1.5 Mtr height from ground level & writing of pole numbers with black paint on poles all as specified and directed. |
| 23 | M&L for painting of LT PCC poles 09 Mtr. with acrylic paint after apply two coat of cement base primer and making the surface smooth including painting of cross arms, clamps, etc with two coat of aluminium paint and providing alternative strip of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 m height, writing of pole numbers in yellow circle 15 cm with black paint on poles complete all as specified and directed. |
| 24 | Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with crimping of suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 4 core. |
| 25 | Description all as per item no. 23.00 above, but 16 Sqmm nominal cross section x 4 core complete all as specifed and directed. |
| 26 | Description all as per item no. 23.00 above, but 25 Sqmm nominal cross section x 4 core complete all as specifed and directed. |
| 27 | Description all as per item no. 23.00 above, but 35 Sqmm nominal cross section x 3.5 core complete all as specifed and directed. |
| 28 | Supply and fix in repairs MCB TPN, 415V, 40 Amps complete all as specifed and directed. |
| 29 | Supply and fix in repairs MCB TPN, 415V, 63 Amps complete all as specifed and directed. |
| 30 | Supply and fix in repairs MCB SPN, 415V, 40 Amps complete all as specifed and directed. |
| 31 | Supply only MCB SP 5 to 32 Amps 230 Volt complete all as specified and as direcetd by Engr-in-Charge |
| 32 | Supply, installation testing and commissioning replacement of street light control box as a pole mountable enclosure conforms to IP-64 suitable for 440/230V, AC, 50 Hz, consisting of a light sensitive control system, power contactor for load switching, MCB and terminal suitable for Single- phase, 8 KW load blocks all as specified Make:- Swadeep Nature Switch model No NAVDEEP-54-8KW1P or equivalent in CG/L&T/phillips |
| 33 | Supply, installation testing and commissioning replacement of street light control box as a pole mountable enclosure conforms to IP-64 suitable for 440/230V, AC, 50 Hz, consisting of a light sensitive control system, power contactor for load switching, MCB and terminal suitable for Three- phase, 12 KW load blocks all as specified. Make:- Nature Switch model No NAVDEEP-54-12KW3P or equivalent in CG/L&T/phillips |
| 34 | Supply and fixing in replacement Single phase contactor 5kW of load capacity 40 Amps, Incoming-Outgoing MCB rating 32-40 Amps & Circuit wiring minimum 10 Sqmm complete all as specified and as directed by Engr-in-Charge. |
| 35 | Supply and fixing in replacement Three phase contactor 8kW of load capacity 32-40 Amps, Incoming-Outgoing MCB (03 Nos each) rating 20-25 Amps complete all as specified and as directed by Engr-in-Charge |
| 36 | Supply and fix Nature switch sensor illuminate level for switching on is < 30 lux and for switching off > 10 lux alongwith part night operation facility of 4-12 Hrs. |
| 37 | Supply and fixing in repairs Digital Timer switch for 1x 24 Hrs for controlling street light timimng with 150 hrs back up. |
| 38 | Supply and fix in repairs PVC tubes, medium grade, 20mm bore for laying of sub-main wire/cable on Street Light Poles and on wall, incl necessary accessories & fixing arrangments like PVC band, clamps , nut -bolts etc.complete all as specified and as directed. |
| 39 | Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete. |
| 40 | Description all as per item no. 38.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.5 m. |
| 41 | M&L for Cement concrete 1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. |
| 42 | M&L for Cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. |
| 43 | M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size 300x300 mm or chamfered on edges all as specified and directed. |
| 44 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specifed and directed. |
| 45 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specifed and directed. |
| 46 | M&L for Sand cushioning with locally available dry unwashed sand in trenches for protection of cables complete all as specifed and directed. |
| 47 | Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed. |
| 48 | Supply and fixing Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete all as specifed and directed. |
| 49 | Supply and fixing Steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall complete all as specifed and directed. |
| 50 | M&L for dismantaling of old cracked /unserviceable PCC poles /MS pole struts any type and size incl deposited at a suitable locations not more than 50 RM away complete all as specified and as directed. |
| 51 | Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 ,9.0 metres long complete all as specified and as directed by Engr-In- Charge. |
| 52 | Taking down old unserviceable street light pole complete including dismantling of street light and shifting the same street light for fixing in another place not more than one km distance including bracket and nut bolt etc. complete all as specified and directed.Note - Excavation, concrete and copping shall be measured and paid separately. |
| 53 | Supply and fix in repair of 40 watt All-In-One Solar Street Light is compact & Fully integrated Intelligent designed Luminaire with Lithium Ferro Phosphate battery, solar panel and charger built into the luminaire,100% Solar Powered, 100% Energy saving,Solar panel Dusk to dawn Operation with Short circuit protection, Over charge protection, Deep discharge protection, Reverse voltage polarity protection and PV reverse voltage polarity protection,Modern portable Off Grid Connection design can be installed anywhere.Rust-proof Aluminum Extrusion housing, dust proof and waterproof,Solar Differential dimming profile :First 0 to 2 Hrs - 100%, Next 2 to 4 Hrs - 60%, Remaining Hrs - 30%,Luminaire efficacy* >150lm/w,Correlated Color Temperature 5665±355K,Color Rendering Index >70,Maintenance of lumen output 50,000 hrs.Operating Temperature Range -10C to 50C , Beam Angle 135° x 85° ,Charge controller MPPT ,Charge controller Efficiency >90% ,Autonomy** 2Days with Differential Dimming ,Charging Time# 1 day ,Ingress Protection IP 65 ,Impact Protection IK 07,Product Dimensions (AXBXC)(mm) 1012 x 500x 55 , MINUMUM weight should be 22 kg ,Luminous flux (lm) 6000lm, Solar panel 70Wp (Mono) 18V ,Battery-LiFePO4 460 Wh. Make : - Bajaj / Philips / Wipro/ Havells / C & S |
| 54 | S&F in repair of LED Tiranga Rope Light 18mtr length per roll , waterproof with IP66 rating & suitable for outdoor application in Indian Tricolour Strip light -Orange +White +Green colour in single strip around steel tubular pole upto 09 mtrs length including clamp, connections from existing junction box complete all as specified and directed. |
| 55 | Attending complaint & Checking of existing Tiranga light fittings using elect tools, equipments and safety devices after arranging elect shut down to remove elect faults like replacing unsv adapter as per existing, replacing unsv connectors as per existing, re-tightning of binding wires ,repairing etc all as required at site and as directed. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safty devices.(ii) Materials like adapters,connectors used for rectification of faults will be measured and paid seperately. |
| 56 | S&F Surya VL-L24 or equivalent Driver/Controller Outdoor type for Tiranga light weatherproof with IP66 rating, Input Voltage 240 volt,Output voltage 24 volt duly prewired suitable for mounting with existing light to make it functional complete all as specified & directed . |
| 57 | S&F Connector used for connecting Strip light with Adapter, Outdoor type weatherproof with IP66 rating duly prewired complete all as specified & directed, Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender