Tender for Provision Of 36M High Antenna Tower At 29Q Det(New Location) And Provision Of High Mast Light At Uhq 42 Weu At Under Ge (Af) Tvm
BOQ
| Sl. No. | Item Description |
| 1 | PROVISION OF 36M HIGH ANTENNA TOWER AT 29Q DET(NEW LOCATION) |
| 2 | Excavation over areas, not exc exc 1.5 m deep and getting out in hard rock, complete all as specified and directed. |
| 3 | Excavation over areas, exc 1.5 m but not exc 3.00 m deep and getting out in hard rock, complete all as specified and directed. |
| 4 | M&L for PCC type B2, 1:2:4 (40mm graded aggregate) as in foundation, footing and mass concrete complete all as specified and directed. |
| 5 | S&F mild steel TMT bar 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm including clips, complete all as specified and directed. |
| 6 | S&F mild steel TMT bar 6 to 8mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm including clips, complete all as specified and directed. |
| 7 | M&L, formwork to Rough finished surfaces of concrete , sides of pillars, posts, struts, piers, tie beams, columns and stanchions rough finished square, rectangular or polygonal surfaces of concrete, complete all as specified and directed. |
| 8 | M&L, for Reinforced cement concrete (design mix) RCC M-30 (using 20 mm graded stone aggregate ) in foundation footing , plinth beams, base of column , under reamed piles and mass concrete, complete all as specified and directed. |
| 9 | M&L Reinforced cement concrete (design mix) M-30 (using 20 mm graded stone aggregate ) Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 10 | S&F mild steel work as in Antenna towers and similar work in platforms at top of the tower conforming to Fe.IS 2062/8500 using Angle Iron130*130*10mm/110*110*10mm/100*100*8mm/100*100*6mm/90*90*6mm/75*75*6mm/50*50*5mm/40*40*5mm or nearest size as directed by GE before commencement of work. The work has to be carried out for a ht of 36M from base. The contractor has to provide all the safety precautions for working and erection of tower and also crane/machinery kept at site for rescue operations /assistance all as specified and directed. etc. Note: (i)The work has to be carried out in remote area near 29Q DET Kanyakumari Therefore one supervisor to be provided for the execution of work exclusivelyii) The steel section shall be structural steel grade Fe IS 2062 for quality and IS 8500 forhigh strength requirement.(iii) The structural steel shall be obtained directly from the manufacturer or approvedstockist and not to be taken from approved dealer.(iv) Nut and bolt for the fixing the base plate to concrete shall be measured separately.But the antenna structure all nut and bolt is included in the unit rate requested.(v). The contractor should see the site and fully be aware of the requirement of materialand labor required for the work. Nothing extra will be entertained at a later stage.(vi)A rough indication or detail of antenna is given in the PS for guidance. The exactdimension and sketch shall be recommended by AGE and approved by GE beforecommencement. |
| 11 | S&F MS bolts machine made with hexagonal or square head one end screwed the other or screwed both end complete all as specified and directed |
| 12 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment etc complete all as specified and directed. |
| 13 | Removing excavated material exc .250m but n exc 500 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. |
| 14 | Returning filling in including spreading leveling watering and well ramming in layers not exc 25 complete all as specified and directed |
| 15 | M&L Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying corrosion treatment using hot dip galvanized (as per IS 2629/IS 4579) with a minimum uniform coating of 85 microns to structural steel members complete all as specified and directed . Note : The contractor should see the site and fully be aware of procurement of items at site. The galvanizing to the structural steel member to be done before incorporating in this work i.e. Pre-fabrication stage. This is a special type of anti corrosive treatment. Therefore contractor has to quote unit rate correctly all as specified and directed.. |
| 16 | M&L Preparation of New steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of epoxy coating as per the directions of Engr-in-charge/GE complete all as specified and directed. |
| 17 | Supply & fixing , testing and commissioning of complete Aviation Obstruction Lighting System for 36 m high antenna tower including supply and installation of LED aviation obstruction warning light of approved make 30watt, 230 V,50 Hz AC operation and mounting at top of tower with necessary GI mounting accessories, complete with wiring using suitable size 3 runs of FRLS PVC insulated round copper conductor cable(80RM) from control point to aviation light routed through tower structure, including all terminations, cable glands, lugs, ferrules, saddles, protective conduit/trunking wherever required, supply and fixing of suitable SP MCB 6A inside weatherproof Syntex/FRP enclosure box (IP-65) with neutral and earth terminals, waterproof entries, testing, commissioning and satisfactory operation, complete in all all as specified and directed.Make; Havells/Bajaj/ seimens/C&S/Luker or any cam |
| 18 | Dynasphere lightning conductor stainless steel as per IEC 61024. The Air terminal shall be placed using the \\" Collection Volume Method / Field Intensification Method\\" placement methodology as specified in IEEE‐998. Make ERICO Cat Part No: D/SMKIVSS or techno-commercially equivalent of SIEMENS/ HARGER complete all as specified and as directed by Engr-in-Charge. Brief features/ specifications of the same is as follows:(a) Impulse Tested, at least for 40 KA both +ve and -ve, 8/20 micro-second, resistance between the terminal tip and the sphere should be a minimum 10 MΩ before and after the test all as specified and directed.(b) Free from the Corona effect.(c) Trigger an upward streamer when there is a downward stream.(d) The dome must be insulated from the rod but connected to ground via a dynamic variable impedance.(e) The centre-grounded electrode tip shall be at least 20 mm in diameter.(f) The terminal must be isolated from the structure using an insulated support mast, making an isolated lightning protection system.(g) The Air terminal should not be dependent upon batteries or external power supplies for any partof its operation.(h) Streamer Emission should not be ESE type. |
| 19 | 5M elevation pole made of AL(aluminum) (Part No. ALU-5M)with a dia of 60mm with an M20 thread at the top to fix the Air terminal unit Make ERICO Cat Part No: FRP- 2.3M or techno-commercially equivalent of SIEIMENS/ HERGER, complete all as specified and directed. |
| 20 | Air terminal Adaptor made up of Brass/SS ( INTCPT-ADM4/4UNC ) for the connectivity between the terminal & Mast with a suitable terminal clamp made up of SS all as specified and directed.. |
| 21 | Guy wire support and all required fixing equipment's. Make ERICO Cat Part No: IGUYKIT7MGRIP complete all as specified and as directed . |
| 22 | 2 Run of Copper Bonded Steel Down Conductor ( Part No CBSC - 8MM), Minimum copper bonding shall be 254microns having Continues Coin form. The conductor core consists of a low-carbon steel grade for improved flexibility in the field. The copper surface of the conductor provides high conductivity and corrosion-resistance properties. The Conductor should be certified by UL & IEC® 62561-2, The life of the CBSC conductor should be 30 years in most of conditions. The part numbers and compliance markings stamped should be directly on the conductor at each and every meter all as specified and directed. |
| 23 | Supply of Clamp Holder made up of 304 grade SS with SS bolt/ nut ( PART NO. CBSC-8 SADDLE) The clamp Suitable for double run of Copper bonded Steel round conductor size of 8-mm. providing every 1 meter all as specified and directed. |
| 24 | Supply, Installation, Commissioning and Testing of Maintenance Free Radial -MAT Earthing system comprising of the following: |
| 25 | Copper Bonded Steel Earth Rod of size 5 feet x 5/8 inch diameter of 4 Nos, earthing system required excavation of 100 mm width x 150 mm depth x 5000 mm length in Square paten Mat radials should be 10 meters apart, Auger 4 Nos hole of diameter 4 inch and 5 feet depth in the soil, Placing the Earth rods in to the augured hole, hammering the rods to 1 feet depth, Readymade FRP Heavy duty earth chamber (450mm x 450mm) Top Cover with minimum 25 ton load bearing capacity, removing excavated material. Complete all as specified and as directed . Brief features/ specifications of CBSE Rod are as follows:-(a) The outer surface must be molecularly bonded with a uniform layer of 250-micron Copper, 99.9% pure electrolytic copper coating.(b) A nickel interface must be provided between the copper and steel to avoid galvanic corrosion.(c) Must be capable of withstanding fusing current of 20 KA.(d) Earth rod must be in compliance with IEC 62305- 2.(e) Tensile strength greater than 80000 PSI on 12 mm.(f) High resistance to corrosion. |
| 26 | Ground Enhancement Material (GEM) , Per Bag -11.33 Kgs ,Conforming to IEC 62561-7 Standard, , Premixing the GEM into slurry form using water( not more than 5 L to 6 L per bag), Pouring the GEM mixture in the augured hole and filling. Make ERICO Cat Part No: GEM 25A- 25-1lb or techno-commercially equivalent of SEIMENS/ HARGER complete all as specified and as directed. Brief features/ specifications of the same is as follows:-(a) Must be carbon based superior conductive material.(b) Resistivity must be less than 2 Ω-cm.(c) Must not cause corrosion to copper when in contact.(d) Must not expand or experience any shrinkage once set.(e) Must not depend on the continuous presence of water / moisture / salt to maintain its conductivity.(f) Must not decompose or leach out with time.(g) Must not contain hazardous chemicals as per IEC 62561-7 standard.(h) Flexural and possess compressive strength as per relevant standard.(j) Sulphur content must be less than 2%. |
| 27 | Cadweld Materials for Connections between Ground Rod with CBSC conductor by Exothermic reaction. Connections to be made with a semi-permanent graphite mould, which shall hold the conductors to be welded. Weld metal must be a mixture of copper oxide and aluminum. Make ERICO Cat Part No: 150 PLUS F20 complete all as specified and as directed . |
| 28 | 8 mm Copper Bonded Steel Round Conductor, minimum copper bonding shall be 254 microns having continuous coin form, the conductor core consists of a low-carbon steel grade for improved flexibility. The copper surface of the conductor should provide high conductivity and corrosion resistance properties, well‐suited as a lightning protection conductor in accordance with the IEC 62305‐3 Edition 2.0 standard. Including excavation depth 30 cm for laying round conductor, removing excavated material, return filling. Make ERICO Cat Part No: CBSC - 8MM complete all as specified and as directed . |
| 29 | S&F Lightning Event Counter, Installed on down conductor, Non resettable mechanical counter, Non electronic without battery or external power source, IP67 enclosure, Triggering impulse < 2 KA, 8/20 micro second, Warning sticker should be provided near to the Down conductor in a visible place. Make ERICO Cat Part No: LEC-IV complete all as specified and as directed . |
| 30 | PROVISION OF HIGH MAST LIGHT AT UHQ 42 WEU AT UNDER GE (AF) TVM |
| 31 | Supply and fixing of High galvanized mast light suitable for 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pulley assembly, aviation obstruction light, cabling for luminaries, lightning arrester spike including RCC foundation as per height 20 meter complete all as specified and directed.. |
| 32 | Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.. |
| 33 | Supply laying jointing cable XLPE insulated PVC sheathed strip wire armored 1100 volt 4 core 25 sqmm multi stranded aluminum conductor laid in trenches/wall/ducts etc. including necessary fixing arrangement such as cable lugs glands etc. complete after removing/taking out ext. unsv cable to the entire all as specified and directed. |
| 34 | Supply , installation, commissioning and testing of outdoor LT feeder pillar kiosk type made out of CRCA sheet 3.15 mm thick vermin proof factory made CPRI approved, with copper bus bar of capacity 100 Amps for 3 phase and neutral with nessary angle iron 50 x 50 x 6 mm support frame including two coats powder painting over a coat of red oxide primer and grout in PCC complete all as specified and directed comprising of the following complete all as specified and directed :-(A)INCOMING :MCCB 40 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA-01 NoIndicator lamps RYB LED type(Set of Three)-01 No(B)OUTGOING :MCCB 32 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA-01 NoMCB DP 6-32 A -01 NoWiring of above accessory with suitable size of copper conductor cableNote :-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel. |
| 35 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level , connected to galvanized earth strip 32x6 mm thick by means of bolts nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No -4 connected to machinery /panel complete including PCC pit in PCC(1:3:6) type C-1, pre cast RCC(1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel deformed bar 15cc and suitable handle of 10 mm Dia round bar including necessary excavation earth work in soft/loose soil and disposal of soil to a distance n.exc 50m all as specified and directed. |
| 36 | Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 meter in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified and directed. |
| 37 | Returning and filling of excavated soil up to a depth of 30 cm after riddling the excavated soil for Cushioning of cable and refilling of trench with normal excavated soil all as specified and directed :- |
| 38 | Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed. |
| 39 | M&L for providing sand cushioning for protection og UG Cable in trenches with dry(coarse) sand approved quality including filling, spreading and punning down to desired thickness complete all as specified and as directed. |
| 40 | M&L for road cutting including excavation , returning filling in, spreading, leveling, well ramming in layers, hardcore with store aggregates received from dismantling the road for 100mm thick and finishing with PCC 1:2:4 with 20mm aggregate for 100mm thick and compacted complete all as directed and match to the existing finish at site .Note:PCC Will measure and paid separately under respective items all as specified and directed.. |
| 41 | M & L in GI pipe of 50 mm dia light grade laid in trenches at road crossings/foot paths complete all as specified and directed. |
| 42 | M&L for Plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregates as in coping including finishing to exposed concrete surfaces even and fair and provision of necessary form work for rough finished surfaces complete including demolition of old damaged pole copings all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender