Power Government Departments Closing in 16 days TDR #56301890

Tender For Procurement Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar (2X600 Mw)

Issued by Government Departments · Jhalawar, Rajasthan
Tender Value
54.28 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
16 days left
EMD
1.08 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jhalawar → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Procurement Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar (2X600 Mw) , Pt Turbine Stm Prs After Gov Stage1 Unit: Mpa Measuring Range: 0 To 15 User Range/Calibration Range: 0 To 15 , Pt No1 Hph Interlocking Stm Prs Unit: Mpa Measuring Range: 0 To 10 User Range/Calibration Range: 0 To 10 , Pt Hpbp Behind Stm Prs 1, Hp Turb Exhaust Stm Left Prs, Hpturb Exhaust Stm Right Prs, Hp Turb Exhaust Stm Hdr Pipe Prs, Reater Interlocking Stm Prs, Crh To Bept Stm Prs, Rh O/Lstm Press, Rh O/L Stm Press, Rh O/L Stm Press, No2 Hphi/L Stm Prs, Crh To Bfpt Stm Prs, Cold Rh Stm To Aux Stm Prs, No 2 Hph Interlocking Stm Unit: Mpa Measuring Range: 0 To 6 User Range/Calibration Range: 0 To 6 , Pt Dearator Press 1,4 Sect. Extr. To Aux Stm Prs, 4 Sect. Extr. To Dea Mov Frt Prs, 4# Extr. To Mfpt Press, Aux Stm To Bfpt, Stm Prs., Mfpt A Interlocking Stm Prs., Aux Stm To Bfpt Stm Prs, Gen Stat Cw Interlocking Wtr Flow, No5 Lph Interlocking Stm Prs, Turb Hp&Ip Gas Gland Stm Prs. 1, Gen Entering Hydrogen Pr. No5 Lph Interlocking Stm Prs Unit: Mpa Measuring Range: 0 To 2 User Range/Calibration Range: 0 To 2 , Pt Lpbp Vlv(Hp) Behind Stm Prs 1, Lpbp Vlv (Lp) Behind Stm Prs 1 Unit: Mpa Measuring Range: -0.2 To 2 User Range/Calibration Range: -0.1 To 2 , Pt No7 Lph A&B Interlocking Stm Prs, No8 Lph A&B Interlocking Stm Prs 1 Unit: Mpa Measuring Range: -0.1 To 0.1 User Range/Calibration Range: -0.1 To 0.1 , Pt Cp Inl Press Unit: Mpa Measuring Range: -0.1 To 0.5 User Range/Calibration Range: -0.1 To 0.5 , Pt Lub Oil Of Turb Prs Unit: Kpa Measuring Range: 0 To 5500 User Range/Calibration Range: 0 To 5500 , Pt Hp Cond Vacuum Pres 1, Lp Cond Vacuum Press 1, Hp Cond Vacuum Prs 1, Lp Cond Vacuum Prs 1, Bfpt B Exhaust Vac Press, Bfpt A Exhaust Vac Press Unit: Kpa Measuring Range: -100 To 100 User Range/Calibration Range: -100 To 100 , Dpt Tdbfbp A Interlocking Filter Dp, Tdbfbp B Interlocking Filter Dp, Tdbfbd O/L Feed Wtr Flow 2, Tdfpa Interlocking Filter Dp, Tdfp A Interlocking Filter Dp, Mbfbp Interlocking Filter Dp, Mbfp Interlocking Filter Dp, Rh Spray Wtr Flow, Sh Spray Wtr Flow 1, 4# Extr. To Aux Stm Flow, 4# Extr. To Mfpt Unit: Kpa Measuring Range: 0 To 100 User Range/Calibration Range: 0 To 100 , Pt Trub Self-Sealing Gland Htr Prs Unit: Kpa Measuring Range: -100 To 600 User Range/Calibration Range: -100 To 600 , Dpt Gen Stat Cw Flow, Seal Oil Dp, Hp Bpv In Steam Flow Unit: Kpa Measuring Range: 0 To 250 User Range/Calibration Range: 0 To 250 , Dpt Tdbfbp A O/L Feed Wtr Flow 1, Tdbfbp B O/L Feed Wtr Flow 1, Tdbfbp B O/L Feed Wtr Flow 3, Mbfbp O/L Feed Wtr Flow 1 Unit: Kpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 40 , Dpt Drum Level Tx. Unit: Mmh2o Measuring Range: -800 To 800 User Range/Calibration Range: -600 To 500 Mmh2o , Dpt Pa Flow, Aph Pa Inlet & Outlet Dp, Secondary Air Flow, Aph Sa Inlet & Outlet Dp Unit: Kpa Measuring Range: -2.0 To 2.0 User Range/Calibration Range: 0.1 To 1.5 , Dpt Feed Control Stn In & Out Dp Unit: Mpa Measuring Range: -0.12 To 10.0 User Range/Calibration Range: 0 To 10.0 , Pt Furnace Press Tx., Aph Inlet And Outlet Gas Press, Esp Intel Gas Press, Id Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa Measuring Range: -8.0 To 8.0 User Range/Calibration Range: -8.0 To 1.0 , Pt Main Feedwater Press, Drum Press Tx., Sh Out Press, Main Steam Press, Sh Spray Water Press., Main Feedwater Mov Front Press., Construction Blowdown Tank Press. Unit: Mpa Measuring Range: -0.1 To 40.0 User Range/Calibration Range: 0 To 30.0 , Pt Secondary Air Pressure Tx., Aph Inlet Sec Air Press, Fd Fan Out Press, Furnace Sec. Air Box Press, Furnace Pressure Unit: Kpa Measuring Range: -60 To 60 User Range/Calibration Range: -7.0 To 7.0 , Pt Cw/Acw Header Pressure, Instrument Air Pressure, Cw Outlet Pressure Iac/Cac Air Pressure Unit: Mpa Measuring Range: 0 To 1.5 User Range/Calibration Range: 0 To 1.5 , Pt Ldo , Hfo Supply And Return Press (With Capillary) Unit: Mpa Measuring Range: 0 To 05 User Range/Calibration Range: 0.1 To 05 , Pt Prds Hdr Press Unit: Mpa Measuring Range: 0 To 6.3 User Range/Calibration Range: 0 To 5 , Pt Mill Loading Oil Pressure Unit: Mpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 25 , Dpt Mill Sealing Air Dp, Sadc/Cadc Press Dp Unit: Kpa Measuring Range: -60 To 60 User Range/Calibration Range: 0 To 5 , Dpt Hfo Filter Dp (With Capillary) Unit: Kpa Measuring Range: -500 To 500 User Range/Calibration Range: -100 To 100 , Dpt Lo Filter Dp (With Capillary) Unit: Kpa Measuring Range: -160 To 160 User Range/Calibration Range: 0 To 100 , Dpt Mill Separator Inlet/Outlet Dp Unit: Kpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 20 , Dpt Scanner Fan Dp Unit: Kpa Measuring Range: 0 To 8 User Range/Calibration Range: 0 To 6.2 , Pt Scanner Fan Press., Mill Separator Outlet Pressure, Mill Seal Air Pressure, Mill Pa Pressure Unit: Kpa Measuring Range: -100 To 400 User Range/Calibration Range: 0 To 30 , Pt Mill Lube Oil Pressure Line Unit :Mpa Measuring Range :-0 To 0.5 User/Calibration Range :-0 To 0.2

BOQ

Name of Work:- Procurement of pressure transmitter (PT) and Differential Pressure transmitter (DPT) at KaTPP, Jhalawar (2x600 MW)
Sl. No. Item Description
1PT Turbine STM PRS After Gov Stage1Unit: Mpa Measuring range: 0 to 15User Range/calibration Range: 0 to 15
2PT No1 HPH I/L STM PRSUnit: Mpa Measuring range: 0 to 10User Range/calibration Range: 0 to 10
3PT HPBP Behind STM PRS 1, HP Turb Exhaust STM LEFT PRS, HPTurb Exhaust STM Right PRS, HP Turb Exhaust STM HDR Pipe PRS, Reater I/L STM PRS, CRH to BEPT STM PRS, RH o/LSTM Press, RH o/L STM Press, RH o/L STM Press, No2 HPHI/L STM PRS, CRH TO BFPT STM PRS, Cold RH STM To AUX STM PRS, No 2 HPH I/L STM Unit: Mpa Measuring range: 0 to 6User Range/calibration Range: 0 to 6
4PT Dearator Press 1,4 Sect. Extr. To Aux STM PRS, 4 Sect. Extr. To Dea Mov FRT PRS, 4# Extr. To MFPT Press, Aux STM To BFPT, STM PRS., MFPT A I/L STM PRS., AUX STM To BFPT STM PRS, GEN STAT CW I/L WTR Flow, No5 LPH I/L STM PRS, Turb HP&IP Gas Gland STM PRS. 1, GENEntering Hydrogen Pr. No5 LPH I/L STM PRS Unit: Mpa Measuring range: 0 to 2 User Range/calibration Range: 0 to 2
5PT LPBP VLV(HP) Behind STM PRS 1, LPBP VLV (LP) Behind STM PRS 1Unit: Mpa Measuring range: -0.2 to 2 User Range/calibration Range: -0.1 to 2
6PT No7 LPH A&B I/L STM PRS, No8 LPH A&B I/L STM PRS 1 Unit: Mpa Measuring range: -0.1 to 0.1User Range/calibration Range: -0.1 to 0.1
7PT CP INL Press Unit: MpaMeasuring range: -0.1 to 0.5 User Range/calibration Range: -0.1 to 0.5
8PT Lub oil of Turb PRS Unit: KpaMeasuring range: 0 to 5500 User Range/calibration Range: 0 to 5500
9PT HP Cond Vacuum Pres 1, LP Cond Vacuum Press 1, HP COND VACUUM PRS 1, LP COND VACUUM PRS 1, BFPT B Exhaust vac Press, BFPT A Exhaust Vac Press Unit: Kpa Measuring range: -100 to 100User Range/calibration Range: -100 to 100
10DPT TDBFBP A I/L Filter DP, TDBFBP 'B' I/L Filter DP, TDBFBDO/L Feed WTR flow 2, TDFPA I/L Filter DP, TDFP 'A' I/L Filter DP, MBFBP I/L Filter DP, MBFP I/L Filter DP, RH Spray WTR Flow, SH Spray WTR FLOW 1, 4# Extr. To Aux STM Flow, 4# Extr. To MFPTUnit: Kpa Measuring range: 0 to 100 User Range/calibration Range: 0 to 100
11PT Trub Self-Sealing Gland HTR PRS Unit: KpaMeasuring range: -100 to 600 User Range/calibration Range: -100 to 600
12DPT GEN STAT CW Flow, Seal oil DP, HP BPV IN Steam flow Unit: Kpa Measuring range: 0 to 250 User Range/calibration Range: 0 to 250
13DPT TDBFBP 'A' o/L Feed WTR Flow 1, TDBFBP 'B' O/L Feed WTR Flow 1, TDBFBP B O/L Feed WTR Flow 3, MBFBP O/L Feed WTR Flow 1 Unit: Kpa Measuring range: 0 to 40 User Range/calibration Range: 0 to 40
14DPT Drum Level Tx. Unit: mmH2O Measuring range: -800 to 800 User Range/calibration Range: -600 to 500 mmH2O
15DPT PA Flow, APH PA inlet & outlet DP, secondary air flow, APH SA Inlet & Outlet DP Unit: Kpa Measuring range: -2.0 to 2.0User Range/calibration Range: 0.1 to 1.5
16DPT Feed Control Stn In & Out DP Unit: MpaMeasuring range: -0.12 to 10.0 User Range/calibration Range: 0 to 10.0
17PT Furnace Press Tx., APH Inlet and Outlet Gas Press, ESP Intel Gas Press, ID Fan Inlet Press, Gas Press Fur. Cavity Unit: KpaMeasuring range: -8.0 to 8.0 User Range/calibration Range: -8.0 to 1.0
18PT Main Feedwater Press, Drum Press Tx., SH Out Press, Main Steam Press, SH Spray water press., Main feedwater MOV front press., Cont. blowdown tank Press. Unit: Mpa Measuring range: -0.1 to 40.0User Range/calibration Range: 0 to 30.0
19PT Secondary Air Pressure Tx., APH Inlet sec air press, FD Fan Out Press, Furnace sec. air Box Press, Furnace Pressure Unit: KpaMeasuring range: -60 to 60 User Range/calibration Range: -7.0 to 7.0
20PT CW/ACW Header Pressure, Instrument Air Pressure, CW outlet pressure IAC/CAC air pressure Unit: Mpa Measuring range: 0 to 1.5User Range/calibration Range: 0 to 1.5
21PT LDO , HFO SUPPLY AND RETURN PRESS (WITH CAPILLARY)Unit: MPa Measuring range: 0 to 05 User Range/calibration Range: 0.1 to 05
22PT PRDS HDR PRESS Unit: Mpa Measuring range: 0 to 6.3 User Range/calibration Range: 0 to 5
23PT MILL LOADING OIL PRESSUREUnit: Mpa Measuring range: 0 to 40User Range/calibration Range: 0 to 25
24DPT MILL SEALING AIR DP, SADC/CADC PRESS DP Unit: Kpa Measuring range: -60 to 60User Range/calibration Range: 0 to 5
25DPT HFO FILTER DP (WITH CAPILLARY)Unit: Kpa Measuring range: -500 to 500User Range/calibration Range: -100 to 100
26DPT LO FILTER DP (WITH CAPILLARY)Unit: Kpa Measuring range: -160 to 160User Range/calibration Range: 0 to 100
27DPT MILL SEPARATOR INLET/OUTLET DPUnit: Kpa Measuring range: 0 to 40User Range/calibration Range: 0 to 20
28DPT SCANNER FAN DPUnit: Kpa Measuring range: 0 to 8User Range/calibration Range: 0 to 6.2
29PT SCANNER FAN Press., Mill Separator outlet Pressure, mill seal air pressure, mill PA pressureUnit: Kpa Measuring range: -100 to 400User Range/calibration Range: 0 to 30
30PT MILL LUBE OIL PRESSURE LINE Unit :MpaMeasuring range :-0 to 0.5 user/calibration range :-0 to 0.2 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56301890
AUTHORITY Government Departments
TENDER VALUE 54.28 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Rajasthan Rajya Vidyut Prasaran Nigam Ltd
Work Description Tender for Procurement Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar (2X600 Mw) , Pt Turbine Stm Prs After Gov Stage1 Unit: Mpa Measuring Range: 0 To 15 User Range/Calibration Range: 0 To 15 , Pt No1 Hph Interlocking Stm Prs Unit: Mpa Measuring Range: 0 To 10 User Range/Calibration Range: 0 To 10 , Pt Hpbp Behind Stm Prs 1, Hp Turb Exhaust Stm Left Prs, Hpturb Exhaust Stm Right Prs, Hp Turb Exhaust Stm Hdr Pipe Prs, Reater Interlocking Stm Prs, Crh To Bept Stm Prs, Rh O/Lstm Press, Rh O/L Stm Press, Rh O/L Stm Press, No2 Hphi/L Stm Prs, Crh To Bfpt Stm Prs, Cold Rh Stm To Aux Stm Prs, No 2 Hph Interlocking Stm Unit: Mpa Measuring Range: 0 To 6 User Range/Calibration Range: 0 To 6 , Pt Dearator Press 1,4 Sect. Extr. To Aux Stm Prs, 4 Sect. Extr. To Dea Mov Frt Prs, 4# Extr. To Mfpt Press, Aux Stm To Bfpt, Stm Prs., Mfpt A Interlocking Stm Prs., Aux Stm To Bfpt Stm Prs, Gen Stat Cw Interlocking Wtr Flow, No5 Lph Interlocking Stm Prs, Turb Hp&Ip Gas Gland Stm Prs. 1, Gen Entering Hydrogen Pr. No5 Lph Interlocking Stm Prs Unit: Mpa Measuring Range: 0 To 2 User Range/Calibration Range: 0 To 2 , Pt Lpbp Vlv(Hp) Behind Stm Prs 1, Lpbp Vlv (Lp) Behind Stm Prs 1 Unit: Mpa Measuring Range: -0.2 To 2 User Range/Calibration Range: -0.1 To 2 , Pt No7 Lph A&B Interlocking Stm Prs, No8 Lph A&B Interlocking Stm Prs 1 Unit: Mpa Measuring Range: -0.1 To 0.1 User Range/Calibration Range: -0.1 To 0.1 , Pt Cp Inl Press Unit: Mpa Measuring Range: -0.1 To 0.5 User Range/Calibration Range: -0.1 To 0.5 , Pt Lub Oil Of Turb Prs Unit: Kpa Measuring Range: 0 To 5500 User Range/Calibration Range: 0 To 5500 , Pt Hp Cond Vacuum Pres 1, Lp Cond Vacuum Press 1, Hp Cond Vacuum Prs 1, Lp Cond Vacuum Prs 1, Bfpt B Exhaust Vac Press, Bfpt A Exhaust Vac Press Unit: Kpa Measuring Range: -100 To 100 User Range/Calibration Range: -100 To 100 , Dpt Tdbfbp A Interlocking Filter Dp, Tdbfbp B Interlocking Filter Dp, Tdbfbd O/L Feed Wtr Flow 2, Tdfpa Interlocking Filter Dp, Tdfp A Interlocking Filter Dp, Mbfbp Interlocking Filter Dp, Mbfp Interlocking Filter Dp, Rh Spray Wtr Flow, Sh Spray Wtr Flow 1, 4# Extr. To Aux Stm Flow, 4# Extr. To Mfpt Unit: Kpa Measuring Range: 0 To 100 User Range/Calibration Range: 0 To 100 , Pt Trub Self-Sealing Gland Htr Prs Unit: Kpa Measuring Range: -100 To 600 User Range/Calibration Range: -100 To 600 , Dpt Gen Stat Cw Flow, Seal Oil Dp, Hp Bpv In Steam Flow Unit: Kpa Measuring Range: 0 To 250 User Range/Calibration Range: 0 To 250 , Dpt Tdbfbp A O/L Feed Wtr Flow 1, Tdbfbp B O/L Feed Wtr Flow 1, Tdbfbp B O/L Feed Wtr Flow 3, Mbfbp O/L Feed Wtr Flow 1 Unit: Kpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 40 , Dpt Drum Level Tx. Unit: Mmh2o Measuring Range: -800 To 800 User Range/Calibration Range: -600 To 500 Mmh2o , Dpt Pa Flow, Aph Pa Inlet & Outlet Dp, Secondary Air Flow, Aph Sa Inlet & Outlet Dp Unit: Kpa Measuring Range: -2.0 To 2.0 User Range/Calibration Range: 0.1 To 1.5 , Dpt Feed Control Stn In & Out Dp Unit: Mpa Measuring Range: -0.12 To 10.0 User Range/Calibration Range: 0 To 10.0 , Pt Furnace Press Tx., Aph Inlet And Outlet Gas Press, Esp Intel Gas Press, Id Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa Measuring Range: -8.0 To 8.0 User Range/Calibration Range: -8.0 To 1.0 , Pt Main Feedwater Press, Drum Press Tx., Sh Out Press, Main Steam Press, Sh Spray Water Press., Main Feedwater Mov Front Press., Construction Blowdown Tank Press. Unit: Mpa Measuring Range: -0.1 To 40.0 User Range/Calibration Range: 0 To 30.0 , Pt Secondary Air Pressure Tx., Aph Inlet Sec Air Press, Fd Fan Out Press, Furnace Sec. Air Box Press, Furnace Pressure Unit: Kpa Measuring Range: -60 To 60 User Range/Calibration Range: -7.0 To 7.0 , Pt Cw/Acw Header Pressure, Instrument Air Pressure, Cw Outlet Pressure Iac/Cac Air Pressure Unit: Mpa Measuring Range: 0 To 1.5 User Range/Calibration Range: 0 To 1.5 , Pt Ldo , Hfo Supply And Return Press (With Capillary) Unit: Mpa Measuring Range: 0 To 05 User Range/Calibration Range: 0.1 To 05 , Pt Prds Hdr Press Unit: Mpa Measuring Range: 0 To 6.3 User Range/Calibration Range: 0 To 5 , Pt Mill Loading Oil Pressure Unit: Mpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 25 , Dpt Mill Sealing Air Dp, Sadc/Cadc Press Dp Unit: Kpa Measuring Range: -60 To 60 User Range/Calibration Range: 0 To 5 , Dpt Hfo Filter Dp (With Capillary) Unit: Kpa Measuring Range: -500 To 500 User Range/Calibration Range: -100 To 100 , Dpt Lo Filter Dp (With Capillary) Unit: Kpa Measuring Range: -160 To 160 User Range/Calibration Range: 0 To 100 , Dpt Mill Separator Inlet/Outlet Dp Unit: Kpa Measuring Range: 0 To 40 User Range/Calibration Range: 0 To 20 , Dpt Scanner Fan Dp Unit: Kpa Measuring Range: 0 To 8 User Range/Calibration Range: 0 To 6.2 , Pt Scanner Fan Press., Mill Separator Outlet Pressure, Mill Seal Air Pressure, Mill Pa Pressure Unit: Kpa Measuring Range: -100 To 400 User Range/Calibration Range: 0 To 30 , Pt Mill Lube Oil Pressure Line Unit :Mpa Measuring Range :-0 To 0.5 User/Calibration Range :-0 To 0.2
Basic Detail
Tender No TN-1310
Bidding Type Tender
Location
City Jhalawar
State Rajasthan
Key Dates
Publish Date 04 Jul 2026
Submission Date 21 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value 54.28 Lakhs
Tender Fee 1180
EMD 1.08 Lakhs
Exemption Not Available
Document List
8da9a88e-7a27-4ba5-856c-22ba4ec1ed39.html
BOQ_1018083.xls
Tendernotice_1.pdf
TN1310.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

8da9a88e-7a27-4ba5-856c-22ba4ec1ed39.html

xls

BOQ_1018083.xls

pdf

Tendernotice_1.pdf

pdf

TN1310.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders