Tender For Repair And Maintenance Work Of Womens Toilets At Pts Thekra Alwar (Remaining Work) Based On Pwd Integrated Bsr 2022 And Electrical Bsr 2022 Rajasthan
Tender Value
7.09 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
9 days left
EMD
14180
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Alwar → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Work Of Womens Toilets At Pts Thekra Alwar (Remaining Work) Based On Pwd Integrated Bsr 2022 And Electrical Bsr 2022 Rajasthan
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 3 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 4 | Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 5 | Supplying and fixing stone lintels/bed plates of approved arry rough dressed in cement mortar 1:4 :Upto 15 cm. thick. |
| 6 | Random rubble dry stone Kharanja under floor. |
| 7 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all Cement mortar 1 : 6 (1 cement : 6 coarse sand)shapes and sizes in |
| 8 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 9 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :12mm thick |
| 10 | Providing and fixing 1st quality standard white, grey, ivory,fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the and pillar) |
| 11 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622colour such as white, grey, ivory, fume red brown, light green,light blue and other light shades in floors, steps, pillars etc.laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4) |
| 12 | P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design.500 litres capacity. |
| 13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes (IS 15778 : 2007 code) having thermal stability for hot 20mm nominal size& cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) |
| 14 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot 25 mm dia nominal bore.& cold water supply including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1 metrespacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. (Internal work Exposedon wall) |
| 15 | P & F Bib Cock (IS:8931 Mark) Superior quality of approved make :C.P. Brass bib cock, 15 mm nominal bore. |
| 16 | P & F European type white glazed vitreous china 1st quality W.C. (IS : 2556 Mark) including cutting and making good the Wall Mounting (syphonic) |
| 17 | P & F Flush Cock / Flush Valve (IS : 9758Mark) for WC of approved quality make :(-do-)exposed 25mm nominal bore. |
| 18 | Construction of manhole in all type of soil inner size 90 X 60 Cm. thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring,making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C.flooring , 25 Kg. CI cover with frame of 40mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth upto 0.5mtr |
| 19 | Construction of chamber in all type of soil with 300 mm thick masonry in Cm 1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 300x300mm depth upto 0.5m & 5Kg C.I. cover with frame |
| 20 | -do- size 450 x 450mm upto depth of 0.5m & 15Kg CI cover with frame |
| 21 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall :Size 510 mm x 400 mm |
| 22 | P&F Beveled edge mirror of special glass of appd make (Atul/equivalent) complet with 6mm thick asbestos cemetn sheet ground fixed to wooden scrwes & washers.Size 600 x 450mm x 4mm thick |
| 23 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. with 37 Cm. long pipe and nut. |
| 24 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 25 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 26 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 27 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 28 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Hot rolled deformed bars (IS : 1139). |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 30 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 31 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 32 | P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant 75mm dia |
| 33 | P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant110mm dia |
| 34 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:A) 110 mm dia |
| 35 | B) 75mm dia |
| 36 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Plain Tee A) 110 mm dia |
| 37 | B) 75mm dia |
| 38 | P&F Grating of approved quality/ make Stainless steel sheet size 125mm dia |
| 39 | Providing and Fixing Unplasticized Poly Vinyl Chloride(UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Nahni Trap without Jali 4” 110mm di |
| 40 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 41 | P & F Square-mouth gully trap `A` grade (IS :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type.Trap size 150 X 100mm, 7.2 Kg. C.I. cover with frame, Internal Chamber size 300 X 300mm. |
| 42 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Vent Cowel 110 mm thick |
| 43 | providing ,lowering laying and jointing in trenches, standard length HDPE ISI marked pipes as per IS 4984 (amended upto date) with necessary jointing material like mechanical connctors, i.e. thread/insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges inspection charges loading / unloading charges stacking of pipe including cost of labour and matierial specials (Tee, bend etc.) Satisfactory hydraulic testing disinfection,m commissioning etc. complete as per techincal specifications and direction of Engineer-in-charge of following class and diameter. (Excluding earth work) Note: Providing and fixing of all requisite specials as per drawing design and layout are inclusive in RM Measurenment of the item and shall not be paid seprately Supply may be in coil or straight length in 6M/12M |
| 44 | P & F water closet Seat Covers with brass hinges complete :do- White. |
| 45 | P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. |
| 46 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure 'A' attached with this BSR |
| 47 | 20 mm |
| 48 | 25 mm |
| 49 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet's &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR |
| 50 | Short point (up to 3 mtr.) |
| 51 | Medium point (up to 6 mtr.) |
| 52 | Long point (up to 10 mtr..) |
| 53 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexiblecopper earth conductor 1.1 kV grade(IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thickwith earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket,Modular face plate with grid plate, screws, making connections, testingetc. as required. For specification of copper Conductor, PhenolicLaminated sheet's & Electrical/ Wiring accessories referChapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work referAnnexure 'A' attached with this BSR |
| 54 | On board |
| 55 | Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances ofoxidization, insulation PVC type A/C/D , flame retardant as per IS10810-53, better amperage rating as per IS:3961 part 5, in existingsurface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitablesize,Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR |
| 56 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 57 | Providing & Fixing of Recessed/surface mounting heavy dutyhorizontal type Double Door ( Metal / Glazed )Distribution boardwith Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and din bar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR |
| 58 | Double door (single phase) |
| 59 | 6 Way |
| 60 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure'A' attached with this BSR |
| 61 | Single pole MCB |
| 62 | 6 A to 32 A rating |
| 63 | Double pole MCB |
| 64 | 6 A to 32 A rating |
| 65 | Four pole MCB |
| 66 | 6 A to 32 A rating |
| 67 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %,round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cabletray(with cable tie) including testing etc. as required of following size. OEM musthave it's own in house NABL accrediated Laboratory for testing procedure as perIS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 68 | 6.0 Sq.mm |
| 69 | 4 core |
| 70 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixturemade of powder coated single piece pressure die cast aluminum material with heat dissipation fins onhousing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125m/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with Highvoltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85%,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrswith Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4KV internal and min 10 KV external inside driver compartment. driver should be Phase to phaseprotection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housingto allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its ownin house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report withliable warranty of product/accessories from OEM shall besubmitted. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached withthis BSR |
| 71 | LED Street Light fixture with Minimum lumen output 5600 lm |
| 72 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I.Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty poleclamp, Saddles suitable fastners etc. asrequired. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR . |
| 73 | 32 mm Dia. |
| 74 | Supply & Laying following size earth wire in horizontal or vertical run inground/surface/recess including riveting, soldering, saddles, makingconnection with GI/Cu purity purity >95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 75 | 8 SWG G.I. ( Hot Dipped ) Wire |
| 76 | Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 77 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 78 | (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts |
| 79 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 80 | (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. |
| 81 | (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. |
| 82 | (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 83 | 25 mm thick and 3 Mtr. Long |
| 84 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb inexisting holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating andFixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . foradditional technical parameters of product/ work, refer Annexure \\"A\\"attacheded with thisBSR. |
| 85 | 9 Watt |
| 86 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD MidPower LED Downlight with power coated die-cast aluminum housing with UV Stabilizednon yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, withShort & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with ,70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more thanthe specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 87 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures.(LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approvedby Engineer in charge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR . |
| 88 | Surface Mounting (with extruded alumn. Housing ) |
| 89 | Minimum lumen output 1300 lm |
| 90 | Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work referAnnexure 'A' attached with this BSR Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysJul 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender