Tender For Repair Maintenance Street Lights, Flood Lights, Timer Panel, Earthing And Fault Detection Allied Works In Zone B Of Age E/M Extension (Elect) Under Ge E/M Lucknow
Tender Value
49 Lakhs
Estimated cost
Bid Submission
25 Jul 2026
18 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Maintenance Street Lights, Flood Lights, Timer Panel, Earthing And Fault Detection Allied Works In Zone B Of Age E/M Extension (Elect) Under Ge E/M Lucknow
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 metre deep in soft / loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in-Charge. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and as directed. |
| 3 | Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 4 | M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed.Note: Punned thickness (18 cm) shall be consider for measurement purpose |
| 5 | M&L laying well burnt old size bricks, sub class \\"B\\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge. |
| 6 | Deployment of tools & manpower for Boring /drilling (Horizontal) manually / mechanically under existing road max 10 M in width) suitable for passing pipe of any description of dia 40 to 100 mm complete all as specified and directed by Engineer in Charge |
| 7 | Material & Laying, jointing and testing in replacement of LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 6 sqmm cross sectional area, 2 core, complete all as specified laid in trenches / laid under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. with and including MS Clamps, nuts, bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items. |
| 8 | All as per item No 07 above but LT under ground cable of size 10 Sqmm 2 core |
| 9 | All as per item No 07 above but LT under ground cable of size 10 Sqmm 4 core |
| 10 | All as per item No 07 above but LT under ground cable of size 16 Sqmm 2 core |
| 11 | All as per item No 07 above but LT under ground cable of size 16 Sqmm 4 core |
| 12 | All as per item No 07 above but LT under ground cable of size 25 Sqmm 3.5 core |
| 13 | All as per item No 07 above but LT under ground cable of size 35 Sqmm 3.5 core |
| 14 | All as per item No 07 above but LT under ground cable of size 50 Sqmm 3.5 core |
| 15 | All as per item No 07 above but LT under ground cable of size 70 Sqmm 3.5 core |
| 16 | All as per item No 07 above but LT under ground cable of size 95 Sqmm 3.5 core |
| 17 | All as per item No 07 above but LT under ground cable of size 120 Sqmm 3.5 core |
| 18 | All as per item No 07 above but LT under ground cable of size 185 Sqmm 3.5 core |
| 19 | All as per item No 07 above but LT under ground cable of size 240 Sqmm 3.5 core |
| 20 | M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old cable complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old cable complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old cable complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for 100 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable including taking down old cable complete all as specified and directed by Engr-in-Charge. |
| 24 | M&L for cutting of PCC / Hard standing / WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e PCC (1:3:6) type C-1 complete all as specified and directed . |
| 25 | Supply, fixing, connecting and testing in replacement MCCB 63 Amp 3 pole 25 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. |
| 26 | Supply, fixing, connecting and testing in replacement MCCB 100 Amp 4 pole 25 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. |
| 27 | Supply, fixing, connecting and testing in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. |
| 28 | Supply, fixing, connecting and testing in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. |
| 29 | Supply, fixing, connecting and testing in replacement MCCB 200 Amp 4 pole 36 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. |
| 30 | Supply, fixing, connecting and testing in replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. |
| 31 | Supply, fixing, connecting and testing in replacement MCCB 400 Amp 4 pole 36 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. |
| 32 | Supply, fixing, connecting and testing in replacement MCCB 630 Amp 4 pole 36 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. Please Enable Macros to View BoQ information |
| 33 | Supply, fixing, connecting and testing in replacement MCCB 630 Amp 4 pole 36 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader, MCCB shall have either double make double break with Arc Chute per pole or single break independent cassette type design, including taking down old existing unserviceable MCCB complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender