Tender For special Repairs To Bldg No T-60, T-62, T-67 At Furniture Yard Of Bso And Provn And Fixing Of Veranda Railing In The Ground Floor Of Officer Qtrs At Dgqa Residential Complex Under Age B/R I/Ii And Age E/M (S) Of Ge (S) Secunderabad
Tender Value
47.98 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
16 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repairs To Bldg No T-60, T-62, T-67 At Furniture Yard Of Bso And Provn And Fixing Of Veranda Railing In The Ground Floor Of Officer Qtrs At Dgqa Residential Complex Under Age B/R I/Ii And Age E/M (S) Of Ge (S) Secunderabad
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in sunken floor, roof incl tarfelt etc and removing from site to a distance n.exc 500 Mtr complete all as specified and as directed. |
| 2 | Demolition of Precast cement concrete block walling built in CM or Cement lime Mortar complete all as specified and as directed. |
| 3 | Dismantling AC corrugated or semi corrugated etc sheets in roof coverings complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description complete all as specified and as directed. |
| 5 | M&L for PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundation filling complete all as specified and as directed. |
| 6 | M&L for PCC 100 mm thick using 1:2:4 type B2 (40 mm graded crushed stone aggregate) as in flooring complete all as specified and as directed. |
| 7 | M & L for cement concrete 1:3:6 type C-1, 75 mm thick using 20mm graded crushed stone aggregates as in plinth protection finished fair and even with using extra cement complete all as specified and as directed. |
| 8 | M&L for precast cement concrete solid block masonry with solid blocks using PCC 1:3:6, type C1 (using 20mm graded crushed stone aggregate), exc. 10cm in width, set in CM 1:4 complete all as specified and as directed. |
| 9 | M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed. |
| 10 | M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed. |
| 11 | S & F Rolled sections as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates complete all as specified and as directed |
| 12 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc and fixed by riveting or welding or with nut and bolts (including nuts and bolts) conforming to Fe-410-W grade E 251 Quality B complete all as specified and as directed. |
| 13 | S&F Mild steel bolts exc 12mm dia and n exc 20mm dia purpose made with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and as directed. |
| 14 | M&L for Painting to new steel and iron surfaces of exc. 10cm wide or girth by two coat of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and as directed. |
| 15 | M&L for Painting to new steel and iron surfaces of n exc. 10cm wide or girth by two coat of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and as directed. |
| 16 | M&L for Preparing old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 17 | S&F 0.50 mm thick prepainted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self taping screws as specified. |
| 18 | S&F 0.56 mm thick plain aluminium sheeting Alloy 31000H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) sheet of any colour fixed with self taping screws complete all as specified and directed. |
| 19 | S &F MS work in wind ties for roof including securing bolts complete all as specified and as directed. |
| 20 | S&F in repairs 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent complete all as specified and as directed. |
| 21 | S&F PVC (SWR) bends 110 mm complete all as specified and directed. |
| 22 | M&L for 75 mm thick plain cement concrete 1:4:8 type D-2 (40 mm using graded crushed stone aggregate ) as in subbase of floor complete all as specified and directed. |
| 23 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footpath, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method usingPU mould, laid in required colour & patternover and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 24 | M&L for Prepration of surface and applying two coat of cement based paint over a coat of primer on wall surfacescomplete all as specified and directed. |
| 25 | Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise n exc 100 sq cm complete all as specified and directed. |
| 26 | S&F Framed work such as grills,gratings, etc.. with ends of barsshouldered and/or riveted, or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings framework of water tanks and similar work conforming to Fe.290.Gde-E 165 complete all as specified and directed |
| 27 | S&F 250mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed |
| 28 | M&L for PCC 1:2:4 type B-0 mix (using 12 mm graded stone aggregate) for back filling of hold fasts to wall complete all as specified and directed |
| 29 | M & L for taking down copper/aluminium point wiring (light, fan, socket, power, security lights or bulkhead) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed |
| 30 | M & L for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FR-LSH unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories surface in wall / ceiling including continous earth wire 1.5 Sqmm PVC insulated FR-LSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in walls and modular white plate covers with frame for mounting of modular switches/sockets etc complete including making good of disturbed surfaces of wall / ceiling / floor all complete all as specified and directed(a) onelight point/ ceiling /exhaust fan point/bell point |
| 31 | (b) One three pin switch socket 6 Amps outlet on independent board complete all as specified and directed. |
| 32 | (c) One three pin switch socket 6 Amps outlet on same board complete all as specified and directed |
| 33 | All as per item No 30 here in above, but with cable 2.5 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 2.5 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed |
| 34 | S & F in repair Modular switch 1 way 6A , 1-module complete all as specified and directed. |
| 35 | S & F in repair Modular switch 1 way 16A with indicator, 1-module complete all as specified and directed. |
| 36 | S & F in repair Modular socket, shuttered type, 6A - 3 pin 2 -module complete all as specified and directed |
| 37 | S & F in repair Modular socket, shuttered type, 6/16A - combined 2-module complete all as specified and directed |
| 38 | S & F in repair 3 pin, 6 A, 250 V ceiling rose having terminal capacity 3 X 1.5 mm² IP 20 protection complete all as specified and directed |
| 39 | S & F in repalcement 20 W surface / wall mounted LED batten light fitting aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated life 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cupper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and as directed |
| 40 | S & F in repalcement LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cupper conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coat of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in complete all as specified and as directed |
| 41 | S & F in repair single pole & neutral, double door, metallic distribution board 8 ways conforming to IEC 61439-3, suitable for flush / surface mounting complete all as specified and directed |
| 42 | S&F in repair of MCB single phase and neutral (SPN), 40 Amps, 230 Volts, connecting with lugs, complete all as specified and directed |
| 43 | S&F in repair of MCB SP 6 to 32 Amps 'C' series complete all specified and directed |
| 44 | M & L for submain wiring using 3 runs of 6 Sq mm 1100 V grade single core FR-LSH flexible cable conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade PVC recessed conduits, conforming to IS 9537 (Part- 3): 1983, of size not less than 25 mm NB, including taking down old submain wire and making good of disturbed surfaces of wall / ceiling / floor all complete all as specified and directed |
| 45 | Supply and laying in trenches, LT underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 10 Sqmm, 4 core multistranded including cable connecting lugs, glands,jointing materials etc, laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall incl taking down existing unserviceable service wire complete all as specified and directed |
| 46 | Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation etc in Hard and Dence soil & getting out for laying of cable complete all as specified & directed. |
| 47 | Returning filling in including spreading leveling watering & well ramming in layers n exc. 25cm thick. |
| 48 | Removing of surplus excavated soil to a distance n.exe 50 Mtr and depositing where directed at a level n.exe 1.5 mtr above the starting point complete all as specified and directed |
| 49 | M & L for sand in trenches as in cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose complete all as specified and directed. |
| 50 | Supply and laying reinforced pre cast concrete cable cover class LV type I flat size 250x150x40mm complete all as specified and as directed. |
| 51 | S&F GI tubing 50mm dia \\"light grade\\" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc, complete all as directed. |
| 52 | M & L for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less' than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES 2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection complete incl taking down old one complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysJul 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender