Tender For Demolition Of T-6 (Guard House, Armoury And Saa Store) And Construction Of Guard House And Station Armoury At Air Force Station Jaipur
Tender Overview
Project Description
Tender for Demolition Of T-6 (Guard House, Armoury And Saa Store) And Construction Of Guard House And Station Armoury At Air Force Station Jaipur
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Jul-2026 | critical date extension | Date | 22-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | NOTE: Schedule ‘A’ Part I to XII are under Ser No. 2.00 to 13.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I. |
| 3 | Lump sum price worked out for Demolition/ Excavation / Earthwork & Site Clearance as listed in Sch `A’ Part II |
| 4 | Lump sum price worked out for Internal Electric Supply as listed in Sch `A’ Part III |
| 5 | Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part IV |
| 6 | Lump sum price worked out for Fire Fighting System as listed in Sch `A’ Part V |
| 7 | Lump sum price worked out for Lightening Protection as listed in Sch `A’ Part VI |
| 8 | Lump sum price worked out for Air Conditioning as listed in Sch `A’ Part VII |
| 9 | Lump sum price worked out for External Electric Supply as listed in Sch `A’ Part VIII |
| 10 | Lump sum price worked out for External Water Supply as listed in Sch `A’ Part IX |
| 11 | Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part X |
| 12 | Lump sum price worked out for Area Drainage as listed in Sch `A’ Part XI |
| 13 | Lump sum price worked out for Fencing & Gate as listed in Sch `A’ Part XII |
| 14 | SCHEDULE 'A' PART - XIII Misc Items is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6. |
| 15 | Taking down carefully copper/ aluminium Sub main wiring of any size from surface/ concealed /existing conduit of any height and removing materials at site complete all as specified and directed. |
| 16 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and carrying to MES store yard complete all as specified and directed. |
| 17 | Taking out/down u/s LT UG cable of size 3.5 core x 50 sqmm size from trenches/ pipe/ ducts/ pole complete all as specified and directed. |
| 18 | S & F for Flame proof brass unions suitable for 20 mm ERW conduit duly certified by CMRI complete all as specified.. |
| 19 | S & F for Flame proof brass bends suitable for 20 mm ERW conduit duly certified by CMRI complete all as specified. |
| 20 | S & F for Flame proof closing plugs suitable for ERW 20 mm dia conduit duly certified by CMRI complete all as specified. |
| 21 | S&F flame proof /Weatherproof 4 way junction box with 4 Nos terminal for looping in and looping out connections, duly certified by CMRI Dhanbad complete all as directed |
| 22 | Supply and fix flame proof/weather proof exhaust fan of 300 mm (12\\") sweep with 0.25HP motor, 230 volts single phase, 50 Hz, with provn pf louvers and bolts nuts and washers including flame proof flexible metallic conduit with necesary electrical connections complete all as specified and as directed. |
| 23 | S&F flame proof Sheet steel metal enclosure with distribution box ,SPN 4 Way 240 Volts with MCB 2 Pole, 25 Amps-1 No, Outgoing MCB SPN, 240 Volts 5-32 Amps- 01 Nos complete with internal Bus Bar & wiring upto terminal, duly certified by CMRI Dhanbad complete all as directed |
| 24 | S & F for Forged Brass Air Release Valve of size 25 mm dia confirming IS 554, with polypropylene float, forged brass seat and chamber, stainless steel spring, nitrile rubber ring complete all as specified and as dircted . |
| 25 | S & F for LT XLPE insulated armoured copper conductor cable conforming to IS 7098-1: 1988, having stranded aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete of size 4 core x 6 Sq mm complete all as specified and directed. |
| 26 | M&L for control console complete all as specified and directed. |
| 27 | M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable of size 2 core x 1.5 Sq mm, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 Volts, drawn through and including concealed MS ERW conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by the engineer-in-charge. |
| 28 | (C) SIGN BOARDSS & F of the following AUTO GLOW signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board for following, complete with mirror fasteners complete all as specified and as directed.(a) Fire lift of size- 4\\" X 12\\" |
| 29 | (b) Emergency Exit of size- 4\\" X 12\\" |
| 30 | (c) \\"DCP\\" Fire Extinguisher of size- 8\\" X 4\\" |
| 31 | (d) \\"CO2\\"Fire Extinguisher of size- 8\\" x 4\\" |
| 32 | (e) In case of Fire, do not use lift, use staircase of size- 8\\" x 8\\" |
| 33 | (f) Flow Arrow Directions Sign |
| 34 | (g) Other Sign Board as per fire Noms |
| 35 | (D) FIRE EXTINGUISHERS & F of 4.50 kgs light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and as directed. |
| 36 | S & F 4.50 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc.complete all as specified and as directed. |
| 37 | S & F for 9 litre Mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed. |
| 38 | S & F for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and as directed. |
| 39 | S & F Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket complete all as specified and as directed. |
| 40 | S & F for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colour complete all as specified and as directed. |
| 41 | S & F Galvanized mild steel Fire breater bracket with 3 mtr bamboo handle painted with red colour complete all as specified and as directed. |
| 42 | M & L for Fire point construted with angle iron frame mounted on PCC platform with PCC 1:3:6 and covered with GI Sheet painted with red colour and letter \\"FIRE\\" in top of shed complete all as specified and as directed. |
| 43 | Supply and Installation, commissioning of Flame proof wall mounted split AC unit outdoor/ indoor complete with flame proof control unit of capacity 1.50 TR working with non CFC refrigirent (R407C), single phase oprating voltage supply 230 Volts, 50 Hz, Dust protection zone 21 & 22 duly certified by CIMFR Dhanbad suitable for clasification Area Zone-I,& II, Gas Groups IIA, IIB, IIC complete all as specified. |
| 44 | Supply and installation for Desert cooler electric driven (single phase), having nominal air flow capacity of 5000 CuM per hour made of steel body complete with all accessories. |
| 45 | Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out 3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) . All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-IN COMING:-a) Copper strip busbar of 200 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nosb) 4 pole MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 25 KA including all fixing accessories with both ends spreader links - 01 No.(c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) Make :- Legrand/L&T/Schneider.(d) Digital multifunctional meter square type with selector switch – 01 NoOUTGOING:-(a) 4 Pole MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 18 KA breaking capacity including all fixing accessories with both ends spreader links - 02 Nos (for Bldg supply & Spare)(b) 4 Pole MCCB 40 Amps with rotary handle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 18 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos (for SMQ accn Bldg supply- 1 No (c) MCB TPN 5-32 Amps, 240 Volts, 10 KA breaking capacity, 'C' series including all fixing accessories with both ends spreader links - 01 No(d) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. |
| 46 | M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii) Test Results of earthing to be submitted by the contractor for all earthings.(iii) The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv) Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v) Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. Please Enable Macros to View BoQ information |
| 47 | M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii) Test Results of earthing to be submitted by the contractor for all earthings.(iii) The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv) Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v) Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 32 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 32 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 34 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender