Housing Urban and Rular Development Government Departments Closing in 2 days TDR #56299574

Tender For Minor Construction Work Of Armorer Workshop At Rpl Bhilwara

Issued by Government Departments · Bhilwara, Rajasthan
Tender Value
38.95 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
2 days left
EMD
77900
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhilwara → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Minor Construction Work Of Armorer Workshop At Rpl Bhilwara

BOQ

Name of Work:- Minor Construction work of Armorer Workshop at RPL Bhilwara
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
2Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
3Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).
4Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
5Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
6Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix
7Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix
8Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix.
9Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
10Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
11Columns, pillars, posts and struts etc.
12Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code)
13Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
14Random rubble dry stone Kharanja under floor.
15Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand)
16Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 4 (1 cement : 4 coarse sand)
17Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry .
18Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Kota stone minimum 30mm thick.
19Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge
20Window fixed.
21Extra for additional shutter in pipe section windows with wire gauge 14 mesh x 24 gauge
22Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
23Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :
2425 mm thick
2520mm thick.
2612mm thick.
276 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand)
28Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm
29Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab from 2001 to 5000 Sqcm
30Providing & fixing precast cement concrete coping 1 : 2 :4 mix 50mm thick complete as per specification :
31Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
32Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
33Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
34Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles.
35Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size.
36Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :Commercial Veneer both side 35 mm thick .
37Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13.
38Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area of the shutter to be measured).
39Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint
40Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
41Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete.
42Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats)
43New Plastered Surface (three or more coats)
44Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
45Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work
46Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood.
47Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
48Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
49Crazy marble stone flooring 20mm thick marble stone with black or of specified colour topping including filling the gaps with cement marble chips mix in proportion of 4 : 7 (4cement : 7 white black or white or black marble chips) size from 1mm to 4mm by volume and under layer of 25mm thick cement concrete [1:2:4, graded stone aggregate 12.5mm nominal size] rubbing and polishing and cement slurry etc. complete :In ordinary cement.
50Making of hole in R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cutting machine complete as per direction of EI From diameter 100mm to 150mm
51P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.
52110 mm dia
53P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:
54Coupler (socket) 110mm dia
55Bend 87 .5 110mm dia
56Pipe Clip 110 mm dia
57P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm.
58P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor
59P & F water closet Seat Covers with brass hinges complete : Solid PVC (IS 2548 marked) grade-I Black for EWC.
60P & F C.P. lugs for toilet seat cover.
61P & F Jet spray for water closet with C.P. Copper Tube flange of approved make.
62P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 550 mm x 400 mm dia for counter top
63P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 750 litres capacity.
64Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)
6520 mm nominal outer dia pipes
6625 mm nominal outer dia pipes
6732mm nominal outer dia pipes
68Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)
6920mm nominal size
7025 mm nominal size
7132mm nominal size
72P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make :CP brass push type concealed 32mm nominal bore.
73P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :
74Gun-metal 32mm nominal bore.
75Gun-metal 25mm nominal bore.
76Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make
7775 mm dia
78110 mm dia
79Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make
80Coupler
8175mm dia
82110mm dia
83Door Bend 87.5 Dg.
8475mm dia
85110mm dia
86Pipe Clip
8775mm dia
88110mm dia
89Single Tee with Door
9075mm dia
91110mm dia
92Nahni Trap with Jali 4”110mm dia
93Vent Cowel
94110mm dia
95P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:
96C.P. Brass bib cock,15mm nominal bore.
97C.P. Brass Long body, 15mm nominal bore weight not less than 690 gm
98P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked)with 37 cm long pipe and nut.
99Providing & fixing C.P.flange for 15mm dia taps.
100P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm.
101Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 M
102Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.
103Inside size 450 X 450mm depth upto 0.5 M Cement cover with frame.
104Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-
105Size 200 x100 x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
106Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 300 Cm. dia outside & 300 Cm. depth .
107Carriage of Earth, Sand, Lime, Morrum manure or sludge for 10km
108Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet's &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR
109Short point (up to 3 mtr.)
110Medium point (up to 6 mtr.)
111Long point (Above 6 mtr.)
112Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
113On board
114Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure 'A' attached with this BSR
115P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A'attached with this BSR
116Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.
1171200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5
118Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
1191170mm(+/-10%) LED batten with min. lumen output 2200 lm
120Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilizednon yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with ,70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more thanthe specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approvedby Engineer in charge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR .
121Minimum lumen output 1300 lm
122Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and dinbar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR
1238 Way (8+2)
124Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure'A' attached with this BSR
125Double pole MCB(With B/C curve tripping Characteristics)
1266 A to 32 A rating
127Single pole MCB (With B/C curve tripping Characteristics)
1286 A to 32 A rating
129Providing & Fixing of 240/415 V factory fitted RCBO with overload,short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provisionfor pad lock, min. Electrical operation 10,000 upto 63 A rating ,minimum phase termination capacity of 35sq.mm. , IP 20 contactprotection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL/ CPRI / ERDA accrediated lab type test reports & All as per preapproved by Engineer in charge. For additional technicalparameters of product / work refer Annexure 'A' attached with thisBSR
130Two pole 100/300mA sensitivity
1316A-32 A rating
132Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR
1332 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
1342 x 2.5 sq. mm. + 1x1.5sqmm
135S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure 'A' attached with this BSR
13620 mm
13725 mm
138Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the groundlevel with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessorieslike nut, bolts, reducer, nipple, wire meshed funnel, and Heavy dutyweather proof poly-propylene earth pit chamber with lockable Jam freelid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. andembodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less asrequired & must record by engineer in charge during site visit and ensureto enter in measurment book.All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR
139Supply & Laying following size earth wire in horizontal or vertical run inground/surface/recess including riveting, soldering, saddles, makingconnection with GI/Cu purity purity >95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with thisBSR .
1408 SWG G.I. ( Hot Dipped ) Wire
141Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-ArrmouredAluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %,Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware /PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testingetc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additionaltechnical parameters of product / work refer Annexure 'A' attached with this BSR
1426.0 Sq. Mm
1433 core
144Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb inexisting holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . foradditional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR
1459 Watt
146Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
147Medium point (up to 6 mtr.)
148Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
1495 step fan regulator 2 Module 360 dgree rotating
150Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
151P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
152P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 100 mm dia.
153Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
154300 mm sweep(900/1400 RPM) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56299574
AUTHORITY Government Departments
TENDER VALUE 38.95 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Rajasthan Police Housing & Construction Corporation Limited
Work Description Tender for Minor Construction Work Of Armorer Workshop At Rpl Bhilwara
Basic Detail
Tender No RPIDCL/NIT-11/2026-27/D-1836 Dt. 29.06.2026
Bidding Type Tender
Location
City Bhilwara
State Rajasthan
Key Dates
Publish Date 04 Jul 2026
Submission Date 14 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 38.95 Lakhs
Tender Fee 1180
EMD 77900
Exemption Available
Document List
15.pdf
77901c81-e638-4afc-87e9-9be3a7b06fab.html
BOQ_1019365.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
pdf

15.pdf

html

77901c81-e638-4afc-87e9-9be3a7b06fab.html

xls

BOQ_1019365.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders