Tender For Addition / Alteration Of Room No 142 & 143 Of Admin Building For Provision Of Molecular Research Centre At Hemrl, Pune
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Jul 2026
18 days left
EMD
83000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition / Alteration Of Room No 142 & 143 Of Admin Building For Provision Of Molecular Research Centre At Hemrl, Pune
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling boarding or false ceiling, any description, fixed in any position with nails / screws complete all as specified and directed. |
| 2 | Providing and fixing false ceiling 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Boards with BIS certification marks) at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge. |
| 3 | Dismantling tile work in floors and dado/skirting laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10mm to 25mm comlpete all as specified and directed. |
| 4 | Providing and laying double charged Vitrified tile polished finish of size 800mm x 800mm in floor (Thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick screed bed in cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 5 | Providing and laying Vitrified tiles in 800 x 800mm sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick backing coat of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed. |
| 6 | Dismantling doors, windows and clerestory window of area 3 sq. metres and below (steel or wood) shutters including chowkhats, architrave, holdfasts etc.complete and stacking within 50 metres lead complete all as specified and directed. |
| 7 | Providing and fixing aluminium frame work for windows (three track), ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be powder coated (minimum thickness of powder coating 50 micron) smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, CP brass / stainless steel screws, all complete as per architecutral drawings and the directions of Engineer-in-charge.(Glazing, panelling and dash fasteners to be paid for separately). |
| 8 | Providing and fixing fly proof stainless steel with aluminium beading grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.50 mm complete all as specified and directed. |
| 9 | Providing and fixing glazing with float glass panes of 4mm thickness (weight not less than 12.50 kg/sqm) in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. |
| 10 | Providing and fixing 18 mm thick Granite stone slab with area exceeding 0.50 sqm of colour black, saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding , rounding to edges and polishing to edges to give high gloss finish etc. complete all as specified and directed. |
| 11 | Providing edge moulding to 18mm thick granite work counters, vanities etc, including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 12 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 13 | Material and labour for 12mm internal plaster in cm (1:6) on fair faces of brick work or concrete surfaces and finish even and smooth without using extra cement complete all as specified and directed. |
| 14 | Providing of newly plaster surface wall and applying two coat of distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete as per manufacture's specification over a coat of primer and 1mm thick plaster of paris putty on surface of walls complete all as specified and directed. |
| 15 | Material and Labour for Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs and Providing and plastered surface to prepare the surface even and smooth to scratches and apply two coat of Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/litre of approved brand and manufacture to give an even shade over a coat of primer including 1mm thick wall care putty on wall as per manufacturer's instruction and complete all as specified and directed. |
| 16 | Providing and supplying 'Optra Acoustical Wall Panelling with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for fire reaction class A as per ASTM E-84, fabric with an option of colors - Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut & Shell as per the choice of the Architect of size 600 x 600 mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using wall panel imalers over and including necessary frame work fibre cement board and construction adhesives as per the instructions laid down by the manufacturer complete all as specified and directed. |
| 17 | Providing and fixing 35 mm thick second class hard wood panelled shutters for doors, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, panel of 12mm thick marine plywood conforming to IS : 710 all as per direction of Engineer-in-charge. (Note : Butt hinges and necessary screws shall be paid separately) complete all as specified and directed. |
| 18 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 125x75x4 mm size as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc complete all as specified and directed. |
| 19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 size of 150x10 mm as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete all as specified and directed. |
| 20 | Providing and fixing bright finished brass 100mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc complete all as specified and directed. |
| 21 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 size of 125 mm as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete all as specified and directed. |
| 22 | Providing and fixing wooden 'L' Jam made out of 11mm thick MDF & covered with 3.5mm MDF and finish with melamine polish etc complete all as specifed and directed by Engineer-in-Charge. |
| 23 | Demolishing brick work in cement mortar manually / by mechanical means including stacking of serviceable materail and disposal of unserviceable material withing 50 metres lead as per direction of Engineer-in-Charge. |
| 24 | Supply and fixing 12mm toughen fixed glass & door work. Modiguard & Assie Glass, Aluminium ionised coated profile section and PVC gasket and weather sealant of DOW SIL 688 & 789. Door fitting make ozone wall mounted over panel top patch with pivot or bottom patch and over side panel connector, 445mm x 25mm SS 'H' type handle, 450 x 32 mm, 120 Kg, floor spring, lock including necessary accessories scaffloding and testing etc as per manufacturere's instructions. |
| 25 | Supply and fixing 10mm toughen glass door work, with motion sensor (automatic stops the operation of prodcut during closing / opening, auto glass door- model SGML 189 auto door set with 1 controller, 1 motor 6.2m meter belt, 1 tension pully device, 1 power switch, 2 stoppers 4.2 meter cover 4.2 meter track complete all as specified and directed. |
| 26 | Taking down copper/aluminimum point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fitting etc removing materials to store for keeeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces for walls, floors, etc complete all as specified and directed. |
| 27 | Dismantling of exhaust fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required including pasting soft stickers indicating MES No of 25mm size of each letter with black synthetic enamel paint etc. complete all as specified and directed. |
| 28 | Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc. for credit schedule complete all as specified and directed. |
| 29 | Taking down unserviceable distribution, boardsheet metal enclosures of any size with RCBOs/MCBs/MCCBs any type for taking schedule of credit complete all as specified and directed. |
| 30 | Taking down unserviceabl submain any type wiring alongwith complete accessories at any height and making good the disturbed surfaces all as specified and directed by Engineer-in-charge. |
| 31 | Group C wiring for light point / socket point / fan point / call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core multistrand copper conductor FRLS cable drawn into & including concealed PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc, complete all as specified and directed.(a) For one light point controlled by one, one way switch. |
| 32 | (b) All as per item No 31 above but for one exhaust fan point controlled by one, one way switch all as specified and directed. |
| 33 | Wiring with copper conductor cables, FRLS, multistranded, unsheathed for one 3 pin socket outlet, 5/15 Amps, independent, with cables 3 Nos single core, 2.5 Sqmm size in concealed conduit complete all as specified and directed. |
| 34 | Supply and fixing 15/16 Amp switch, 1 module on the existing modular plate & switch box including connection but excluding modular plate etc. complete all as specified and directed. |
| 35 | All as per item No 31 above but 6 Pin 15/16 A socket, 2 module |
| 36 | S&F in repairs ceiling rose 3 terminal 240 volts, 5 Amps |
| 37 | Supply and fixing in 3 module (100 mm x 75 mm) size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc complete all as specified and directed. |
| 38 | Supply and fixing 63 Amps triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB complete all as specified and directed. |
| 39 | Material and labour for Sub main wiring comprising single core, 2 runs of 6 Sqmm nominal cross sectional area multistranded FLRS copper conductor cable, PVC insulated unsheathed cable 1100 V grade drawing in and including PVC rigid non metallic concealed conduit/surface conduit with necessary civil works for making good the disturbed surface with PVC conduits and conduit fittings complete including 1 x 6 Sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade each wire complete all as specified and directed.Note : 02 runs 6 Sqmm cable and 1 run of 6 Sqmm cable for earth wire shall be measured as one unit for the purpose of payment. |
| 40 | Material and labour for Sub main wiring comprising single core, 4 runs of 10 Sqmm nominal cross sectinal area multistranded FLRS copper conductor cable, PVC insulated unsheathed cable 1100 V grade drawing in and including PVC rigid non metallic concealed conduit/surface conduit with necessary civil works for making good the disturbed surface with PVC conduits and conduit fittings complete including 2 x 6 Sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade each wire complete all as specified and directed.Note : 04 runs 10 Sqmm cable and 2 run of 6 Sqmm cable for earth wire shall be measured as one unit for the purpose of payment (for 3 phase industrial socket). |
| 41 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 42 | Supply, installation, testing and commissioning of 1200mm sweep, BEE, 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) motor, class of insulation: B, 3 Nos, blades, 30 cm long down rod, 2 Nos, canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, Service value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (Tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise equal to 75⁰C (Max), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC etc complete all as specified and directed. |
| 43 | Supply and fix air circulator fans 230 volts single phase oscillating 450mm sweep suitable ofr wall mounting complete all as specified and directed. |
| 44 | Supply and fix exhaust fan, steel body AC single phase, 230V of size 300mm sweep with, blades, frame and louvers as required complete all as specified and directed. |
| 45 | Supply and fixing in 4 way (4+12), double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc (without MCB/RCCB/Isolator) including taking down old distribution board complete all as required. |
| 46 | Supply and fixing in 12 way (4+36), double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc (without MCB/RCCB/Isolator) including taking down old distribution board complete all as required. |
| 47 | Supply and fixing single pole blanking plate in the existing MCB DB complete all as specified and required. |
| 48 | Supply and fixing 5A to 32A rating, 240V, 10kA, \\"C\\" curve, miniature, circuit breaker suitable for inductive load of single pole in the MCB DB complete with connection, testing and commissioning etc as required including taking down old one complete all as directed. |
| 49 | Supply and fixing 415V 10KA 'C' curve 63 Amps, miniature, circuit breaker (MCB) triple pole and neutral pole and current carrying capacity 63 Amps in the DB complete with connection, testing and commissioning (in TPN DB 12 Way) etc as required including taking down old one complete all as directed. |
| 50 | Supply and fixing MCCB 63 A rating, four pole (Three phase and neutral), 415V, braking capacity 16 KA, adjustable and thermal magnetic release type in the existing MCB DB complete with connection, testing and commissioning etc. complete all as directed. |
| 51 | Supply and fixing MCCB 160 A rating, four pole (Three phase and neutral), 415V, breaking capacity 36 KA, adjustable and thermal magnetic release type in the existing MCB DB complete with connection, testing and commissioning etc. complete all as directed (Main /C for 12 way TPN DB) |
| 52 | Material and Labour for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab GI funnel with GI watering pipe 20mm dia med grade, wire mesh, protection pipe 20mm dia GI pipe light grade for earth lead upto 7.50 m long complete all as specified and directed by Engineer-in-Charge. |
| 53 | Providing and laying earth connection from earth electrode with 6 SWG dia GI wire in 15mm dia GI Pipe from earth electrode including connection with GI thimble excavation and re-filling as required complete all as specified and as directed. |
| 54 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core including taking down complete all as specified and directed. Please Enable Macros to View BoQ information |
| 55 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core including taking down complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender