Tender For Repair/Maintenance Of Dg Set With Amf Panel, Eot Crane, Lightning Arrestors/ Conductors, Solar Water Heaters, Air Conditioners, Refrigerators, Water Coolers And Walk-In-Refrigerator And Connected Accessories & Allied Works At Naa Including
Tender Overview
Project Description
Tender for Repair/Maintenance Of Dg Set With Amf Panel, Eot Crane, Lightning Arrestors/ Conductors, Solar Water Heaters, Air Conditioners, Refrigerators, Water Coolers And Walk-In-Refrigerator And Connected Accessories & Allied Works At Naa Including Holeswar Area Under Ge (N) Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR/MAINTENANCE OF DG SET WITH AMF PANEL, EOT CRANE, LIGHTNING ARRESTORS/ CONDUCTORS, SOLAR WATER HEATERS, AIR CONDITIONERS, REFRIGERATORS, WATER COOLERS AND WALK-IN-REFRIGERATOR AND CONNECTED ACCESSORIES & ALLIED WORKS AT NAA INCLUDING HOLESWAR AREA UNDER GE (N) TEZPUR Contract No : GE(N)/TEZ/ OF 2026-2027 (8283) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | Servicing & Maintenance for DG set of capacity 100 KVA by replacing the following accessories to ensure its satisfactory performance complete all as specified and directed by Engnr-in-charge : (a) Replacement of suitable grade Engine Oil and coolant(b) Replacement for Oil filter, fuel filter and Air filter(c) Replacement for water separator(d) Radiator cleaning with chemical(e) Replacement for change of fuel pipe(f) Replacement for change of fan belt size (g) Replacement for change of hose pipe with clamp Note :- (i) 'B' checks shall be carried out by OEM of company. Certification of the same shall be submitted to Engnr-in-charge.(ii) BLANK(iii) Labour & transportation shall be arranged by contractor at his/her own cost.(iv) Serviceable drain out engine oil and fuel of DG set shall be reused after cleaning.(v) Make of DG set to be repaired : KIRLOSKAR/ CUMMINS /GREAVES/ASHOK LEYLAND or any other make. (vi) Maintenance of DG set to be carried out as per manufacturers instructions and by qualified service engineer of DG set service center. (vii) Materials/Spare parts/Lub oil required for above maintenance shall be measured and paid seperately under repective items as \\"Supply only Materials\\". |
| 3 | Description all as per items No 01 here-in-before but DG set of capacity 62.5 KVA complete all as specified and directed by Engnr-in-charge. |
| 4 | Description all as per items No 01 here-in-before but DG set of capacity 15 KVA complete all as specified and directed by Engnr-in-charge. |
| 5 | Supply only of Lub Oil of specific grade (20W40 or Eqv.) for carrying maintenance under serial item No-1 above complete all as specified and directed by Engnr-in-charge. Make-Kirloskar/ Servo pride(IOC)/Castrol/Veedol or Equivalent. |
| 6 | Supply only of Premix Coolent of radiater water for carrying maintenance under serial item No-1 above complete all as specified and directed by Engnr-in-charge. Make-Kirloskar/ Servo pride(IOC)/Castrol/Veedol or Equivalent. |
| 7 | Supply only of Lub Oil filter element with 'O' ring, for carrying maintenance for the DG set capacities 100 KVA DG set complete all as specified and directed by Engnr-in-charge. |
| 8 | Supply only of Lub Oil filter element with 'O' ring, for carrying maintenance for the DG set capacities 62.5 KVA DG set complete all as specified and directed by Engnr-in-charge. |
| 9 | Supply only of Lub Oil filter element with 'O' ring, for carrying maintenance for the DG set capacities 15 KVA DG set complete all as specified and directed by Engnr-in-charge. |
| 10 | Supply only of Fuel filter element with 'O' ring, for carrying maintenance for the DG set of capacities 100 KVA complete all as specified and directed by Engnr-in-charge. |
| 11 | Supply only of Fuel filter element with 'O' ring, for carrying maintenance for the DG set of capacities 62.5 KVA complete all as specified and directed by Engnr-in-charge. |
| 12 | Supply only of Fuel filter element with 'O' ring, for carrying maintenance for the DG set of capacities 15 KVA complete all as specified and directed by Engnr-in-charge. |
| 13 | Supply only of Air filter element and Vaccutator Valve for air cleaner for maintenance for the DG set capacity 100 KVA as complete all as specified and directed by Engnr-in-charge. |
| 14 | Supply only of Air filter element and Vaccutator Valve for air cleaner for maintenance for the DG set capacity 62.50 KVA as complete all as specified and directed by Engnr-in-charge. |
| 15 | Supply only of Air filter element and Vaccutator Valve for air cleaner for maintenance for the DG set capacity 15 KVA as complete all as specified and directed by Engnr-in-charge. |
| 16 | S&F in repair for Fan Belt for dynamo for 100 KVA DG set complete all as specified and directed by Engnr-in-charge. |
| 17 | S&F in repair for Fan Belt for dynamo for 62.5 KVA DG set complete all as specified and directed by Engnr-in-charge. |
| 18 | S&F in repair for Radiator Fan Belt of DG 100KVA complete all as specified and directed by Engnr-in-charge. |
| 19 | S&F in repair for Water Pump for DG set( 100KVA kirloskar Bliss) Including replacement of complete assembly as Gasket, Bearing,Hose pipe, rubber seal & clamp for any capacity DG setcomplete all as specified and directed by Engnr-in-charge. |
| 20 | Supply only for filling of Distilled Water for Batttery complete all as specified and directed by Engnr-in-charge. |
| 21 | M&L for takingout and replacement of Indicator lamp for R-Y-B phase complete all as specified and directed by Engnr-in-charge. |
| 22 | M&L for Takingout and repalcement of oil presure meter for 62.5/100 KVA DG set complete all as specified and directed by Engnr-in-charge. |
| 23 | M&L for Taking down and replacement of Water temperature meter (as per sample) for 100 KVA DG Set complete all as specified and directed by Engnr-in-charge. |
| 24 | S&F in repair for Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush etc for the DG set of capacity 100 KVA complete all as specified and directed by Engnr-in-charge. |
| 25 | As per item no 19 but for the DG set of capacity 62.5 KVA complete all as specified and directed by Engnr-in-charge. |
| 26 | S&F in repair for alternator assembly,transporting to authorised workshop for rewinding and refixing after repair and testing incl replacement of Main stator coil winding,rotor winding, axuilary coil winding and carbon brush etc for the DG set of capacity 100 KVA complete all as specified and directed by Engnr-in-charge. |
| 27 | As per item above but for the DG set of capacity 62.5 KVA complete all as specified and directed by Engnr-in-charge. |
| 28 | S&F in repair for complete self starter assembly of DG set of capacity 100 KVA complete all as specified and directed by Engnr-in-charge. |
| 29 | S&F in repair for complete self starter assembly of DG set of capacity 62.5 KVA complete all as specified and directed by Engnr-in-charge. |
| 30 | M&L for fixing the asbestos rope on silencer of DG set of various capacity including cladding with asbestos powder over wire mesh complete all as specified and directed by Engnr-in-charge. |
| 31 | M&L for cleaning of the fuel tank by vacating the tank, replacement of fuel level indicator and spray painting of tank by scraping the existing paint using enamel paint of two coat with matching the existing clour complete all as specified and directed by Engnr-in-charge. |
| 32 | M&L for Replacement of Automatic Voltage regulator Device (AVR) for the DG set of capacity 62.5 to 100 KVA of Make- Kirloskar Bliss/Kirloskar Green or Equivalent |
| 33 | Reparing/Overhauling & calibration FIP with injection of 100 KVA all as specified and directed by EIC and manufacturer instruction. |
| 34 | Reparing/Overhauling & calibration FIP with injection of 62.5 KVA all as specified and directed by EIC and manufacturer instruction. |
| 35 | M&L for fixing of 120 AH,12 Volt lead acid battery of Make: Exide New Express or equivelet. |
| 36 | M&L for fixing of 180 AH,12 Volt lead acid battery of Make: Exide New Express or equivelet. |
| 37 | Supply & Fix manual change over switch system 3 phase ,415 volt , AC , 200 Amp with sheet steel enclouser extended handle all as specified and directed by EIC. |
| 38 | M & L for replacement of voltmeter(LED/Digital) 50-500 volt range as per sample. |
| 39 | M&L for AMF panel troubleshooting& repairing of wiring,relays,switches and phase terminals with voltage corrections of DG sets capacity 62.5-100 KVA all complete as specified and directed. Note: The spare parts required for repairing is deemed included in the quoted rate. |
| 40 | M & L in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long icluding necessary fixing arrangement using MS clamps,nuts & bolts complete all as specified and directed. |
| 41 | S & F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed |
| 42 | M & L Alluminium strip 25 x 3.15 mm with procelain saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 43 | S & F in repairs Galvanised iron strip 32 x 6mm buried in ground or fixed to Roof, Walls by using appropriate insulating Boxes with screws complete all as specified and directed. |
| 44 | S&F in repair solar water heating tube suitable for 200LPD heating capacity all as specified and directed. |
| 45 | M&L for Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore all complete as specified . |
| 46 | M&L Carry out load test on (Deflection) EOT Crane under 100% of full load capacity of crane on hoisting, long & cross travel, micro checking in performance including loading, unloading, Transportation, handling and returning the test load obtained from concerned unit for EOT crane capacity 2 Ton EOT Crane (Mobile Crane, Truck & Trailer arranged by contractor) all as specified and directed by Engr-in-chargeNotes:- (i) The required load is to be arranged by the contractor under his own arrangements including transporting to and from the site without any extra cost to the department.(ii) Crane testing is to be carried out by the authorised inspector as per factories act. |
| 47 | Periodical Examination, normal and routine maintenance/repairs and renewals of spares of EOT cranes of any make and model as available on site for 2 Ton capacity all as specified and directed by Engr-in-charge. :-Notes:- (i) Supply Only sapres shall be measured and paid for seperately under relevant items of this schedule A. The unit rate shall deemed to include the cost of labour for fixing the spares. (ii) Any miniors repairs required other than specified in the schedule is deemed to be included (iii) The rate is deemed to be included one crane mechanic and helper for attending complaints normal routine maintenance and minor repairs whenever breakdown occurs. |
| 48 | Discconecting and taking down electromagnetic thruster/ Hydraulic Brake unit from the crane, Shifting to the workshop, Dismantiling all parts, replacement of unserviceable parts like bearings, Brake coil, Thruster oil,assembling, shifting to existing location and fixing in a same position complete testing the system all as directed by Engineer-in-charge. |
| 49 | Supply only relay PCB Board high capacity,flux protection NO contact form rated coil volatage 110V AC to 12 V AC supply single pole 10Amps Suitable up to 2 Ton Crane complete all as directed by Engineer-in-charge. |
| 50 | Material & Labour for rewinding of electromagnetic brake super enamelled copper of existing gauge and No of turns, with proper insulation, varnishing, bailing and testing on completion work all as directed by Engineer-in-charge, |
| 51 | Supply only power contractor upto 32 Amps with 2 NO and 2 NC for EOT Cranes of 2 Ton capacity complete all as specified and directed by Engineer-in-charge. Make : Siemens /L&T or as equivalent make as in approved list of makes. |
| 52 | Supply only Long liver type 2 way limit switches suitable for CT & LT operation fo EOT Cranes of 2 Ton capacity complete all as specified and directed by Engineer-in-charge. Make: SOC or as equivalent make as in approved list of makes. |
| 53 | Supply only of PVC flexible copper Cable size 19 Core 1.5 sqmm, 2 mm dia steel wires,insulation class 2/3 operational volage 300V/500V, operating temperature 5 to 70 ⁰ C, Flame resistance including cable gland, termination and testing etc complete all as specified and directed by Engineer-in-chargeMake : Polycab/Havells/Finolex |
| 54 | Supply only of PVC flexible copper Cable size 4 Core 4 sqmm, nsulation class 2/3 operational volage 300V/500V, operating temperature 5 to 70 ⁰ C, Flame resistance including cable gland, termination and testing etc complete all as specified and directed by Engineer-in-chargeMake : Polycab/Havells/Finolex or as equivalent make as in approved list of makes. |
| 55 | Supply only Gear oil Servo 120, Kinematic viscosity cst @ 40 ⁰ C 220 -250, flash point (COC) 250 complete all as specified and directed by Engineer-in-charge Make: Servo/Castrol or as equivalent make as in approved list of makes. |
| 56 | Supply and toping up of silicon Transformer oil dielectric strength, viscosity 50 cst (Cent Stokes) complete all as specified and directed by Engineer-in-charge Make : Power oil or as equivalent make as in approved list of makes. |
| 57 | Supply only Transformer 500V for EOT crane capacity 02Ton all complete as specified and directed. |
| 58 | Supply only Steel wire rope 10mm dia complete all as specified and directed by Engineer-in-charge. Make : Usha Martin or as equivalent make as in approved list of makes. |
| 59 | Supply only VVVFD (Variable voltage variable frequency Drive) with DBR slip resistance and required electrical cables, lugs, ferule numbers etc.for Capacity 2 TON EOT Crane for Main Hoist application including taking down VVVFD complete all as specified and directed by Engineer-in-charge . |
| 60 | Supply only pendent Push button 10 way suitable for 02 Ton EOT crane all complete as specified and directed. |
| 61 | S&F Crane Wheel of suitable for 2 Ton capacity complete all as specified and directed by Engineer-in-charge. |
| 62 | M&L for control panel rewiring with suitable material for EOT crane 02 Ton capacity .Note: The cost of minor spare parts will be included in the quoted rate all complete as speicifed and directed. |
| 63 | M&L for Magnetic Coil 415V of EOT crane of capacity 02 TON all as specified and directed. |
| 64 | S&F Gear Coupling for EOT crane suitable for 2TON capacity. |
| 65 | M&L for pneumatic brake drum dia 200mm for EOT crane suitable for 02Ton Capacity all complete as specified. |
| 66 | S&F in repair pressure switch universal type complete all as specified and directed. |
| 67 | M & L for preparing and painting of EOT crane capcity 02 Ton including Platform ,rails bars , and panel etc with one coats of red oxide primer over cleaned surface by sand paper and including two coat of yellow synthetic enamel paint over existing painted surface complete all as specified and as directed. |
| 68 | Taking down old u/s LT UG Cables of any size from trenches/poles/walls complete after disconnection all as specified and directed |
| 69 | M&L for Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of 25sqmm 4core complete all as specified laid in trenches / laid under floor for EOT crane and connected equipment complete all as specified and directed. |
| 70 | M&L for Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of 150sqmm 3.5core complete all as specified laid in trenches / laid under floor for main panels complete all as specified and directed. |
| 71 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe /Cables etc complete all as specified. |
| 72 | Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified and directed. |
| 73 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified and directed. |
| 74 | M&L for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed. |
| 75 | M&L laying well burnt old size bricks, sub calss \\"B\\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed. |
| 76 | M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed. |
| 77 | M&L for fixing the asbestos rope on silencer of DG set of various capacity including cladding with asbestos powder over wire mesh. |
| 78 | M&L for PCC in Foundations with B0 type 1:2:4 12.5mm graded aggreagate, including rafts, footings, foundation beams ,plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all complete as directed. |
| 79 | M & L for Earthing in replacement with galvanised steel pipe electrode, 40 mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4 mm dia galvanised iron wire all as shown in Plate No. 2 ( SSR Part-1) to the earthing test point all as specified and indicated , necessary excavation any type of soil, CI chamber cover 10 mm with 6 mm rod , wire mess, funnel, test point, 40 mm dia GI protection pipe medium grade etc complete and testing on completion all as specified and directed by Engr-in-charge . (Note :-(i) Fresh agriculture soil / black dirt or soil with a high organic conten will be used for filling the dug as required when rocky /sandy soil found at site to achieve the desired resistance from out side without any extra cost.(ii) Painting of earthing pit cover with synthetic enamel paint incl writing the earth resistance value on the same.) |
| 80 | S & F in repair automatic transfer switch pre wired with upto 200 Amp current rating , UV/OV protection , phase sequence & single phasing protection , 415 volt AC complete all as specified and directed. |
| 81 | M&L for replacement of MCCB 4 pole,125Amp 25KA of make Legrand/L&T/HPL or as per site all complete as specified and directed. |
| 82 | M&L for replacement of MCCB 4 pole,315 Amp 25KA of make Legrand/L&T/HPL or as per site all complete as specified and directed. |
| 83 | M&L for replacement of MCCB 4 pole,250 Amp 25KA of make Legrand/L&T/HPL or as per site all complete as specified and directed. |
| 84 | M&L for replacement of MCCB 4 pole,400 Amp 25KA of make Legrand/L&T/HPL or as per site all complete as specified and directed. |
| 85 | M&L for replacement of battery charger suitable for 12/24 Volt battery for DG set as per sample and depositing unserviceable one to AGE E/M store yard all complete as specified and directed. |
| 86 | S&F in repair Battery 12 Volts, 150 AH Battery including depositing existing unserviceable one to AGE E/M store yard complete all as directed. Make :- Exide, Amco, Nicco, Amaron or any other equivalent make as approved by GE |
| 87 | S&F, in repair, compressor unit of water cooler, storage type 40/80 litres capacity including necessary cutting, welding complete with all fixing accessories as required and as directed. Note - Leakage testing, flushing of system and charging of gas shall be measured and paid separately under relevant items here in after. |
| 88 | M&L for Leakage testing of compressor of water cooler 40/80 ltr capacity by dry nitrogen complete all as specified and directed. |
| 89 | M&L for flushing of the refrigerator system of water cooler 40/80 ltr capacity with dry nitrogen , replacement of capillary tube, strainer and drier of required size and , assembling the system, after applying appropiate vacuum upto (-) 75cm column of mercury, complete all as specified and as directed . |
| 90 | M&L for recharging of gas in compressor of water cooler 40/80 ltr capacity with refrigerant gas R- 22/134 (a) as required and testing the water cooler with satisfactory cooling effects after installing at indicated location complete all as specified and as directed . |
| 91 | S&F, in repair, thermostate ISI marked for water coolers of 40/80 ltrs capacity complete all as specified and directed. |
| 92 | S&F, in repair, Over load relay (OLR) for water coolers of 40/80 ltrs capacity complete all as specified and directed. |
| 93 | S&F, in repair, starting capacitor (SC) 40/60 Mfd for water cooler 40/80 ltr capacity complete all as specified and directed. |
| 94 | S&F, in repair, PVC float valve assembly 15mm dia for water cooler 40/80 ltrs capacity complete all as specified and directed. |
| 95 | S&F, in repair, push tap assembly 15 mm dia chromium plated for water cooler 40/80 ltr capacity complete all as specified and directed. |
| 96 | S&F, in repair, blower fan motor of water cooler of capacity 40/80 Litres complete all as specified and directed |
| 97 | M&L for Preparation of old painted surfaces of water cooler of 40/80 Litres capacity including compressor and applying one coat of approved synthetic enamel paint to body of water cooler and one coat of black paint to compressor, by using spray painting machine, complete all as specified and directed. |
| 98 | S&F, in repair, compressor unit of refrigerator 180 to 310 litres capacity including necessary cutting welding complete with all fixing accessories as required and as directed. Note - Leakage testing, flushing of system and charging of gas shall be measured and paid separately under relevant items here in after. |
| 99 | M&L for recharging of gas in compresssor of refrigerator 180 to 310 litres capacity with refrigerant gas 134 (A) as required and testing the refrigerator with satisfactory cooling effects after installing complete all as specified and directed. |
| 100 | S&F, in repair, thermostate (defrost type), ISI marked for refrigerators 180 to 310 litres capacity complete all as specified and directed |
| 101 | S&F, in repair, Lamp, (screw/pin type) as required suitable for refrigerator of 180 to 310 litres capacity complete all as specified and directed |
| 102 | S&F, in repair, cooling chamber as per existing model for refrigerator of 165 to 310 litres capacity complete all as specified and directed |
| 103 | S&F, in repair, magnetic door Gasket suitable for refrigerator 180 to 310 litres capacity complete all as specified and directed |
| 104 | S&F, in repair, chiiler door suitable for regrigerator 180 to 310 litres capacity complete all as specified and directed |
| 105 | S&F, in repair, chiller tray suitable for regrigerator 180 to 310 litres capacity complete all as specified and directed |
| 106 | S&F, in repair, vegetable/fruit tray suitable for refrigerator 180 to 310 litres capacity complete all as specified and directed |
| 107 | S&F, in repair, Over load relay (OLR) for refrigerators 180 to 310 litres capacity complete all as specified and directed. |
| 108 | S&F, in repair, blower fan motor of 180 to 310 litres capacity Refrigerator complete all as specified and directed . |
| 109 | Servicing on site of complete out door /indoor unit of Split type AC 1.5 to 2 TR capacity after removing electric connection by cleaning of condensor coil, evaporator coil, blower & motor, air filter, louver, other connected accessories and replacemement of unserviceable screws, nuts,bolts, washers from the body of the ACs by providing new one and making the same perfectly tight and noiseless during operation complete all as specified and directed. Note. Spare/parts, components required will be measured and paid separately under relevant items here-in-after as supply only. |
| 110 | Supply only room sensor suitable for Split type /Window type AC of capacity 1.5 TR to 2 TR ,complete all as specified. |
| 111 | Supply only coil sensor suitable for Split/window type AC of capacity 1.5 TR to 2 TR ,complete all as specified. |
| 112 | Supply only air filter suitable for split type AC of capacity 1.5 TR to 2 TR ,complete all as specified. |
| 113 | S&F, in repair, blower fan motor of Split type AC of capacity 1.5 TR to 2 TR complete all as specified and directed |
| 114 | S&F, in repair, Power Control board (PCB) Inverter type or as per site complete for 1.5 TR to 2 TR split type AC complete all as specified and directed. |
| 115 | S&F, in repair, Outdoor unit condenser coil (copper) complete for 1.5 TR split type AC complete all as specified and directed. |
| 116 | S&F, in repair, Indoor unit cooling coil (copper) complete for 1.5 TR split type AC complete all as specified and directed. |
| 117 | S&F, in repair, sealed compressor unit for Split type AC 1.5 TR capacity including necessary cutting, welding with all fixing accessories as required Complete all as specified and directed. Note - Leakage testing, flushing of system and charging of gas shall be measured and paid separately under relevant items here in after. |
| 118 | S&F, in repair, sealed compressor unit for Split type AC 2 TR capacity including necessary cutting, welding with all fixing accessories as required Complete all as specified and directed. Note - Leakage testing , flushing of system and charging of gas shall be measured and paid separately under relevant items here in after . |
| 119 | M&L Leakage testing of compressor of Split type AC 1.5 to 2 TR capacity by dry nitrogen complete all as specified and directed . |
| 120 | M&L for flushing of the refrigerator system ie refrigerant coil of evaporator, condensor and interconnecting copper tube of Split type AC 1.5 TR to 2 TR capacity with dry nitrogen flushing upto vacuum (- 75 cm) column of mercury & replacement of old strainer /drier by new one as per existing size, complete all as specified and directed . |
| 121 | M&L Re-Charging of gas refrigerant R-22 to split type AC of 1.5TR to 2.00 TR capacity on full load, checking automatic cut-out, setting of room temperature and testing complete all as specified and directed . |
| 122 | Servicing in situ of complete window type air conditioner 1.5 TR to 2 TR capacity after removing electric connection by cleaning of condensor coil, evaporator coil, blower & motor ,air filter , louver ,other connected accessories and replacemement of unserviceable screws, nuts,bolts, washers from the body of the ACs by providing new one and making the same perfectly tight and noiseless during operation complete all as specified and directed. Note - Spare/parts components required will be measured and paid separately under relevant items here-in-after as supply only. |
| 123 | Supply only Multi Capacitor upto 65 Mfd for Split / window type AC capacity 1.5 TR to 2.00 TR, complete all as specified. |
| 124 | S&F, in repair, Power control board ( remote circuit)complete for 1.5 TR to 2 TR window type AC complete all as specified and directed. |
| 125 | Supply only thermostate ISI marked suitable for window type AC capacity 1.5 TR to 2 TR ,complete all as specified. |
| 126 | Supply only air filter suitable for window type AC of capacity 1.5 TR to 2 TR ,complete all as specified. |
| 127 | S&F, in repair, blower fan motor for window type AC of capacity 1.5 TR to 2 TR ,complete all as specified and directed. |
| 128 | S&F, in repair, condenser coil (copper) complete for 1.5 TR Window AC complete all as specified and directed. |
| 129 | S&F, in repair, Cooling coil (copper) complete for 1.5 TR Window type AC complete all as specified and directed. |
| 130 | S&F, in repair, sealed compressor unit for Window type AC 1.5 TR capacity including necessary cutting, welding with all fixing accessories as required Complete all as specified and directed. Note - Leakage testing, flushing of refregerator system and charging of gas shall be measured and paid separately under relevant items here in after . |
| 131 | S&F, in repair, sealed compressor unit for Window type AC 2 TR capacity including necessary cutting, welding with all fixing accessories as required Complete all as specified and directed. Note - Leakage testing, flushing of refregerator system and charging of gas shall be measured and paid separately under relevant items here in after . |
| 132 | M&L Leakage testing of compressor of Window type AC 1.5 to 2 TR capacity by dry nitrogen complete all as required and directed. |
| 133 | M&L for flushing of the refrigerator system ie refrigerant coil of evaporator, condensor and interconnecting copper tube of Window type AC 1.5 TR to2 TR capacity with dry nitrogen flushing upto vacuum (-) 75 cm column of mercury & replacement of old strainer or drier by new one as per existing size, complete all as specified and directed . |
| 134 | M&L for Preparation of old painted external surfaces of window type AC 1.5TR to 2 TR capacity including compressor and applying one coat of approved synthetic enamel spray paint to body of window AC and one coat of black paint to compressor, by using spray painting machine, complete all as specified and directed. |
| 135 | M&L Re-Charging of gas refrigerant R-22 to 1.5TR to 2.00 TR capacity Window type AC on full load, checking automatic cut-out and setting of room temp and testing complete all as specified and directed . |
| 136 | S&F, in repair, compressor unit for Deep Freezer capacity 320 Ltr including necessary cutting welding complete with all fixing accessories as required and as directed. Note. Leakage testing , flushing of refregerator system and charging of gas shall be measured and paid separately under relevant items here in after. |
| 137 | M&L for Leakage testing of compressor of deep freezer 320 ltr capacity by dry nitrogen complete all as specified and directed. |
| 138 | M&L for flushing of the refrigerator system of deep freezer 320 ltr capacity with dry nitrogen and replacement of old capillary tube strainer and drier by new one of required size, assembling the system, after applying appropiate vacuum upto (-) 75cm column of mercury complete all as specified and as directed . |
| 139 | M&L for recharging of gas in compresssor of Deep freezer 320 litre capacity with refrigerant gas R-22 as required and testing the deep freezer with satisfactory cooling effects after installing at indicated location complete all as required and directed . |
| 140 | S&F, in repair, over load relay (OLR) for Deep Freezer of 320 Ltrs capacity complete all as specified and directed. |
| 141 | S&F, in repair, starting capacitor 100/120 Mfd for Deep Freezer of 320 Ltrs capacity complete all as specified and directed. |
| 142 | S&F, in repair, thermostate suitable for Deep Freezer of 320 Ltrs capacity, complete all as specified and directed. |
| 143 | S&F, in repair, blower fan motor of Deep Freezer of 320 Litres capacity complete all as specified and directed. |
| 144 | M&L for complete servicing of walk in freezer refrigeration unit (Cold storage) air cooled with semi hermatic condensing units of capacity 25643 BTU/Hr of make blue star complete all as specified and directed. |
| 145 | Supply and filling of refrigerant gas R-404R for walk in freezer(Cold Storage) refrigeration unit air cooled with semi hermatic condensing unit complete all as specified and directed. |
| 146 | Supply and fixing in replacement three phase relay (as per existing model/make in control/display panel of walk in freezer) complete all as specified and directed. |
| 147 | Supply and fixing in replacement 3/4 phase power contactor (as per existing model/make L&T NC1 1801 in control/display panel of walk in freezer) complete all as specified and directed. |
| 148 | S&F, in repair, voltage stabilizer of capacity 4 KVA ,220 V for water coolers and deep freezers etc. complete all as specified and directed. |
| 149 | S&F, in repair, voltage stabilizer of capacity 5 KVA ,220 V for window ac and split ac complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender