Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56299035

Tender For Provn Of Cctv Monitoring Room And Associated Works And Arboriculture Work In Hq Ops Complex Of Pts At Af Stn Agra

Issued by Statutory Bodies & Commissions/Committees · Agra, Uttar Pradesh
Tender Value
37 Lakhs
Estimated cost
Bid Submission
25 Jul 2026
18 days left
EMD
74000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Cctv Monitoring Room And Associated Works And Arboriculture Work In Hq Ops Complex Of Pts At Af Stn Agra

BOQ

Name of Work:- PROVN OF CCTV MONITORING ROOM AND ASSOCIATED WORKS AND ARBORICULTURE WORK IN HQ OPS COMPLEX OF PTS AT AF STN AGRA
Sl. No. Item Description
1Surface excavation n.exc. 30 cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed
2Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, including forming bottom surface for laying of pipes/ cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
3Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but not exc 3.0M in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, including forming bottom surface for laying of pipes/ cable etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.
4M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
5Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
6Removing excavated material (soil) exc 1.5KM and n exc. 5 KM and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
7M&L Treating bottom and sides of excavation at the arte of 5 litres of emulsion per square metre of surface area complete all as specified
8M&L Treating the backfills in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface ( area of the structure in contact with backfill to be measured) complete all as specified
9M&L Treating the top surface of filled earth at the rate of 5 lires of emulsion per square metre of surfacecomplete all as specified.
10M&L for reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregates) as in footings, foundation, beam, plinth beams, bases for columns etc complete all as specified and directed.
11M&L for reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregates) as in columns ,pillars, post and strut etc complete all as specified and directed.
12M&L for use & waste of form work to sides of concrete foundations ,footings,bases of columns ,raft beams ,sides and sofit ( if any) of foundation and plinth beams and similar work or to better rough finished surface of concrete etc complete all as specified and directed.
13M&L for use & waste form work to sides of pillars, posts, strut, piers, columns and stanchions, square or rectangular on plan, finished the surface rough of concrete etc complete all as specified and directed.
14S&F mild steel TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns hooking ends and binding with mild steel wire anealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
15S&F mild steel TMT bars 5mm dia and over upto and including 10 mm dia in stirrups, cut to length bent to shape required, including cranking, bending, spirally for hooping for columns hooking ends and binding with mild steel wire anealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
16M&L for reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed.
17M&L for reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregates) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
18M&L for reinforced cement concrete M-25 Design Mix (using 20mm graded stone aggregates) as in chajjas and the like complete all as specified and directed.
19M&L for use & waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.etc complete all as specified and directed.
20M&L for use & waste form work to to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
21M&L for brick work with sub class 'B' bricks (using old size bricks), straight or curved on plan, exc 6M mean radius, built in CM 1:6 complete all as specified and directed .
22M&L for brick work with sub class 'B' bricks (using old size bricks), straight or curved on plan to any radius, built in CM 1:4 as in half brick thick walls complete all as specified and directed .
23M&L for 40mm thick cement concrete 1:2:4, type B-0 (using 12.5mm graded stone aggregates ) as in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified.
24M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick work or concrete surfaces, finished the surface even and smooth (without using extra cement) complete all as specified and directed.
25M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces, mixed with water proofing compound @ 200 Ml per bag of cement or as per manufacturer's instructions and finished the surface even and smooth (without using extra cement) complete all as specified and directed.
26M&L for 5mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces in ceilings, finished the surface even and smooth (without using extra cement) complete all as specified and directed.
27Supply only Liquid water proofing compound complete all as specified and directed.
28M&L for 100 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in flooring etc, finished the surafce fair and even complete all as specified and directed
29M&L for Hardcore of broken stone or broken boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
30M&L for PCC 1:3:6 type C-2 ( 40mm graded stone aggregates), 75mm thick as in plinth protection, path, hard standing etc, laid in alternate by etc complete all as specified and as directed.
31M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base of floor, hard standing etc, finished the surafce fair and even complete all as specified and directed
32M&L Dark Shade/Double charged/ ultracharged Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile exc 0.42 Sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 20 mm thick screed bed or bedding layer in CM(1:6) etc complete all as specified and directed.
33Description all as per item No 33 above but on vertical surfaces such as in skirting incl 10 mm thick plaster in CM (1:3) etc complete all as specified and directed.
34M&L for sand cushioning / filiing under floor or laid dry to the profile under interlocking block including watering and consolidation complete all as specified and as directed.
35M&L for machine pressed precast concrete interlocking paver block of approved shape and size conforming to IS: 15658-2006 of 60mm thickness, with minimum compressive strength of 35N/sqmm (M-35 grade) without correction factor for chamfering, with grey cement and pigment complete all as specified and directed.
36S&F Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall of any height, fixed with self tapping screw, washers etc complete all as specified & directed.
37M&L for providing and fixing factory made UPVC any colour casement (Openable) Door made of extruded profile with wall thickness of 2.3mm ( + 0.2mm). Window profile with hollow section with multi chambered, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + 0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 8mm thick toughened glass etc complete all as specified and directed by Engr in Charge. Note- rate quoted by contractor shall include, the cost of 8 mm thick toughened glass and other connected accesseories.
38Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
39M&L framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
40S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
41S & F venetian blinds in double layers roller type of approved colour including all accessories,fittings/fixtures required for fixing the same in window complete all as specified and directed.
42M&L two coats of distemper oil emulsion on newly plastered surfaces over a coat of primer over 3mm thick wall putty as on wall including preparation of surfaces, complete all as specified and directed.
43M&L for preparation of newly plastered surfaces and applying two coats of apex paint over a coat of primer etc complete all as specified and directed.
44M&L for Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS at 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 5x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 tiles fully center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in charge.
45M & L for cement concrete 1:2:4 type B1 ( using 20 mm graded stone aggregate) (average 50 mm thickness) in roof for padding to achieve the slope requires including applying bonding coat of Dr Fixit pidicret MPB & cement in the ratio of 1:2 on the slab surfaces before laying PCC roof slab all as directed
46M&L for rendering or bedding layer 15mm thick in CM (1:4) including water proofing compounnd @ 200 ml per bag of cement or as per manufacturer instrurction complete all as specified and directed.Note :- WPC shall be measured and paid seprately.
47M&L for Priming surface and applying evently a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/sqm including cleaning surface complete all as specified and directed.
48M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non wave fabric(wt not less than 150 gms/sqm) land on primed surface by torch application complete all as specified
49M&L Preparation of surface any description, over 10cm in width or girth not otherwise described applying two coats of aluminium paint over a coat of aluminium red oxide primer complete all as specified and directed.
50M&L for 12mm thick perforated medium density fibre sound absorber wall, paneling, exterior grade, colour and pattern as decided by GE, fixed with GI frame with screw incliding back filling with 50mm thick acoustic glass wool sound observing material and to make Auditorium echo free complete all as directed. Note: Work will be executed through specialized firm and certifacte of Echo free will be furnished from certified agency before completion of work.
51M&L for 5mm thick PVC cover fillet of standard hard board, 40mm wide and fixing with screw complete all as specified and directed.
52Dismantling iron fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
53Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
54S&F Steel work in trusses fabricated with rectangular / Square hollow section, including special shaped, washers etc including cutting welding, bending in shape etc using tube of YST 310 grade confirming to to IS-4923 complete all as specified & directed.
55M&L for submain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm FR and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in PVC conduit 20mm dia including concealed ISI marked cutting chases to walls for laying conduit and making good the disturbed wall surfaces complete all as specified and directed. Note:- Two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
56M&L for Concealed Point wiring complete with 1.5 sqmm 1100 graded PVC FRLS (Multistrand) insulated unsheathed copper conductor single core multi strand flexible cable maintaining colour coding (Phase- Red/yellow/Blue, Neutral- Black), PVC conduit not less than 20mm dia concealed, including cutting chases in brick wall including CI/MS sunken box as required size on site with PVC white cover plate of suitable size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, and touching with three coats of existing colour of wall complete all as specified and directed.with all accessories including single core multistranded copper conductor 1.5 sqmm size cable (green colour) as earth continuity wire connected to common earth dolly to modular concealed box for housing switches, sockets etc for one light / fan/ bell point controlled by one switch one way complete all as specified and directed.
57All as per srl item No 56 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
58All as per srl item No 56 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
59All as per srl item No 56 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
60Supply & fixing switch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed.
61Supply & fixing for socket outlet 2 in 1, 3 Pin 5 amps flush type, universal 230 volts complete all as specified and directed.
62Supply & fixing switch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed.
63Supply & fixing for socket outlets 3 pin 15 amps flush type, universal 230 volts complete all as specified and directed.
64Supply and fixing steped type electronic fan regulator flush type . AC, 230 volts, duly ISI marked with and including connector complete all as specified
65Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge.
66S&F decorative ultra slim linear LED 20 Watt 4' long lighting fixture with extruded at heat sink, environment friendly, energy efficient ready to use pack including LED tube complete with inbuilt electronic driver, PCB, connector block etc. including connecting up three copper flexible cable from ceiling rose to fittings including connecting up and fixed on including two nos PVC square box of required size complete all as specified & directed.
67Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt( White/ Warm White) , 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in- Charge .
68Supply and fixing in repair/replacement ceiling fan complete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC) including down rod not less than 300 mm and connection with three core copper wire etc, complete Please Enable Macros to View BoQ information SCHEDULE OF CREDIT 1. All worn out/unserviceable materials/items which will be obtained from different items of Sch `A’/ BOQ (as mentioned above) during replacement work, shall become contractor’s property and amount of credit shall be recovered from the contractor's RAR & final bill as and when payments are submitted. These materials shall be allowed to be removed from works site only after credit amount for the same is recovered from the contractor’s payment. Items not covered under this Schedule shall become the property of department and the same shall be returned/ deposited by the contractor at MES store yard without any extra cost to department/ government and all materials which are credited to the contractor, shall be recorded in MB 2. The contractor shall have no claim regarding fixation of credit rates in this schedule and no rebate on \\"Schedule of credit\\" rates/ amount shall be accepted. However contractor can offer more credit rates/ amount. 3. The total credit amount may vary as per execution of work above different items involved in this credit schedule. 4. The quantities given in column 4 are provisional and same shall be measured and paid based on actual quantities obtained against relevant items of Schedule ‘A’/ BOQ. These materials shall not be reused/ reincorporated in the work except where specified. 5. The measurements of dismantled materials shall be the gross quantity obtained and not the net quantity considered for payment in schedule. The old and unserviceable materials to be retrieved from taking down/demolition/dismantling etc are considered in schedule of credit. No claim of contractor with regard to quality/position of old materials shall be entertained Srl No Description of item Qty Unit Assessed rate by department Remarks Rate in (Rs) Amount in (Rs)
69Supply and fixing in repair/replacement ceiling fan complete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC) including down rod not less than 300 mm and connection with three core copper wire etc, complete Please Enable Macros to View BoQ information SCHEDULE OF CREDIT 1. All worn out/unserviceable materials/items which will be obtained from different items of Sch `A’/ BOQ (as mentioned above) during replacement work, shall become contractor’s property and amount of credit shall be recovered from the contractor's RAR & final bill as and when payments are submitted. These materials shall be allowed to be removed from works site only after credit amount for the same is recovered from the contractor’s payment. Items not covered under this Schedule shall become the property of department and the same shall be returned/ deposited by the contractor at MES store yard without any extra cost to department/ government and all materials which are credited to the contractor, shall be recorded in MB 2. The contractor shall have no claim regarding fixation of credit rates in this schedule and no rebate on \\"Schedule of credit\\" rates/ amount shall be accepted. However contractor can offer more credit rates/ amount. 3. The total credit amount may vary as per execution of work above different items involved in this credit schedule. 4. The quantities given in column 4 are provisional and same shall be measured and paid based on actual quantities obtained against relevant items of Schedule ‘A’/ BOQ. These materials shall not be reused/ reincorporated in the work except where specified. 5. The measurements of dismantled materials shall be the gross quantity obtained and not the net quantity considered for payment in schedule. The old and unserviceable materials to be retrieved from taking down/demolition/dismantling etc are considered in schedule of credit. No claim of contractor with regard to quality/position of old materials shall be entertained Srl No Description of item Qty Unit Assessed rate by department Remarks Rate in (Rs) Amount in (Rs)
70Old iron scrap (obtained from demolition of slab, grill,grating, guardbar, curtain rod, bracket, etc.)
71Old steel sheeting Total amount of credit schedule 5500.0 Signature of contractor AGE (Contracts) For ACCEPTING OFFICER

AI Tender Summary

OUR REF NO 56299035
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 37 Lakhs
LAST DATE 25-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Cctv Monitoring Room And Associated Works And Arboriculture Work In Hq Ops Complex Of Pts At Af Stn Agra
Basic Detail
Tender No 8200-1830/E8
Bidding Type Tender
Location
City Agra
State Uttar Pradesh
Key Dates
Publish Date 03 Jul 2026
Submission Date 25 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value 37 Lakhs
Tender Fee 500
EMD 74000
Exemption Available
Document List
1830Tender.pdf
b72660a5-068c-4030-aad1-92d77aafbd4b.html
BOQ_869400.xls
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
pdf

1830Tender.pdf

html

b72660a5-068c-4030-aad1-92d77aafbd4b.html

xls

BOQ_869400.xls

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders