Tender For Repair/ Maint/ Of Ht Distribution System,Serving Of Ht Breakers,Vcb And Rmus ,Replacement Ht Ug Cable, Lighting Arrester,God And Repair Of Tranformers At Range Hills Area Under Ge(Mh & Rh) Khadki.

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
24.97 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
5 days left
EMD
49940
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maint/ Of Ht Distribution System,Serving Of Ht Breakers,Vcb And Rmus ,Replacement Ht Ug Cable, Lighting Arrester,God And Repair Of Tranformers At Range Hills Area Under Ge(Mh & Rh) Khadki.

BOQ

Name of Work:- REPAIR/ MAINT/ OF HT DISTRIBUTION SYSTEM,SERVING OF HT BREAKERS,VCB AND RMUS ,REPLACEMENT HT UG CABLE, LIGHTING ARRESTER,GOD AND REPAIR OF TRANFORMERS AT RANGE HILLS AREA UNDER GE(MH & RH) KHADKI.
Sl. No. Item Description
1S&F in replacement Switch Air break Gang operated HT 22 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based 9 insulator and fitted on steel frame horizontally mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete all as specified and directed by engineer-in-Charge.
2Supplying, installing, fixing, connecting and testing of Polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame 200 Amps capacity, siutable for 22 KV, HT system, out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete all as specified and directed by engineer-in-Charge.
3M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 22000 Volts supply including taking down old lightning arresters complete all as specified and directed by engineer-in-Charge.
4M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 11000 Volts supply including taking down old lightning arresters complete all as specified and directed by engineer-in-Charge.
5Taking down unsv/damaged HT cable of 11KV/22 KV, of size 95 Sqmm and 120 Sqmm from the trench /pole/wall complete all as specified and directed by engineer-in-Charge. Note:- Earth work shall be measured and paid seprately under relevent item of schedule.
6Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and directed by engineer-in-Charge.
7Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 120 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and directed by engineer-in-Charge.
8Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 300 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and directed by engineer-in-Charge.
9Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 11000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and directed by engineer-in-Charge.
10M & L for cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size and voltage grade including taking down old cable joint kit complete all as specified and directed by engineer-in-Charge.
11All as per Item No 10 above but of Size 95 sqmm x 3 core
12All as per Item No 10 above but of Size 120 sqmm x 3 core to 185 Sqmm x 3 Core
13All as per Item No 10 above but of Size 240 Sqmm 3 Core to 300 sqmm x 3 core
14M & L for cable jointing kit for 22 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size including taking down old cable joint kit complete all as specified and directed by engineer-in-Charge.
15All as per item No 11 above but of Size 95 sqmm x 3 core
16All as per item No 11 above but of Size 120 sqmm x 3 core to 185 Sqmm x 3 Core
17All as per item No 11 above but of Size 240 Sqmm 3 Core to 300 sqmm x 3 core
18M & L for heat shrinkable HT 22 KV (earthed) outdoor type straight through joint cable kit suitable for aluminium conductor cable of following size including taking down old cable joint kit complete all as specified and directed by engineer-in-Charge.
19All as per Iten No 12 above but of size Size 95 sqmm x 3 core
20All as per Iten No 12 above but of Size 120 sqmm x 3 core to 185 Sqmm x 3 Core
21M & L for cable jointing kit raych 22 KV Touch proof kit for HT 22 KV (Earthed) grade cable for indoor type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm to 300 Sqmm including taking down old cable joint kit complete all as specified and directed by Engineer-in-charge.
22M & L for cable jointing kit for HT 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down old cable joint kit charge complete all as specified and directed by Engineer-in-charge.
23M & L for cable jointing kit for 11 KV of Size upto 3 core 95 sqmm (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm including taking down old cable joint kit complete all as specified and directed by Engineer-in-charge.
24M & L for heat shrinkable HT 11 KV (earthed) straight through joint of size upto 95 Sqmm cable kit suitable for aluminium conductor cable of size upto 95 sqmm 3 core including taking down old cable joint kit complete all as specified and directed by Engineer-in-charge.
25M&L for cable route indicator made out of Cast iron of dia 100 mm embrosed with HT cable with 25mm x 5 mm GI flat of length 1 mtr including painting with two coats of synthetic enamel red colour paint over a coat of primer to exposed surfaces complete all as specified and directed by the Engineer-in-charge.
26M & L for detect HT 11 KV/22 KV cable fault for various size of cable with technician around the clock at HT sub stations and area under AOR of GE (MH & RH) khadki detect the cable fault and necessary excavation of soil and refilling the soil, joint the faulty cable with new straight through joint kit, after jointing, testing, and charging of HT cable all as specified and directed by Engineer-in-Charge. Note: (i) Cable joint required size measured and paid separately (ii) Each job considered cable fault locator use in one day
27M&L for errecting in repair steel tubular swaged poles in true vertical position ( or to be fixed in an inclined positon as strut pole) steel tublar swaged poles complete with MS base plate of 6 mm thick of size 450x450 mm finial taper plug , pole cap,bolts ,nuts and washer and screwd pole made out of ERW MS tubing confirming to IS -2713 (part-II) 1980 type 410 SP-55 (11 meters long) pole including drilling of holes of required size for fixing of cross arms, painting with one coat of red oxide primer and two copat of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete , etc complete all as specified and directed by the Engineer-in-charge.
28M&L in repair for cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washer, welding,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and one finishing coat of coat of paint complete all as specified and directed by the Engineer-in-charge.
29M&L cement concrete 1 : 4 :8 type D2 , using 40 mm graded stone aggregate for PCC pole/struts, stay assembly, foundation filling and mass complete all as specified and directed by the Engineer-in-charge.
30M&L cement concrete 1 : 3 : 6 type C1, using 20 mm graded stone aggregate as in coping of pole etc complete all as specified and directed by the Engineer-in-charge.
31M&L for Painting the Transformers of capacity upto 500 KVA with two coat of synthetic enamel paint heat proof of same colour including preparation of old surfaces complete includuing writing the MES No, SM No & capacity of transformer in bold letter complete all as specified and directed by the Engineer-in-charge.
32M&L for Painting on two pole structure along with connected MS stays, bracings, C- channels complete at height upto 11 mtrs with two coat of aluminum paint over red oxide paint after preparation of old surfaces complete as existing and complete all as specified and directed by the Engineer-in-charge.
33M&L for Painting on four pole structure with connected MS stays, bracings, C- channels complete at height upto 11 mtrs two coat of aluminum paint over red oxide paint after preparation of old surfaces , complete as existing complete all as specified and directed by Engineer- in -charge .
34M&L for spray painting to exposed surface of steel tubular pole HT pole 11 Mtr long with two coats of synthetic enamel aluminium paint(as per existing color) over a coat of red oxide primer including preparation of old painted surface by scrapping or complete removal of old paint, filling cavities with filler complete all as specified and directed by Engineer- in -charge
35Disconnecting the HV side 22 KV & LV side 0.415KV of transformer and removing electrical connections including neutral earth strip of existing step down transformer, drain out the complete oil of transformer and store carefully in clean container. Cleaning of all HV/LV windings terminals, cleaning of conservator tank, cooling fins/tubes, tank, etc. Thuroughly inspecting of core and winding complete, reinsert the core coil assembly into the transformer tank, replacing 5/3 mm thick rubberised corksheet gasket of top cover complete and refilled with filtered transformer oil upto the desired level marked in conservator tank and record the insulation resistance of the winding both HV/LV side between earth and HV/LV winding, reconnecting the HV/LV side electric cables complete of following capacity of stepdown transformer complete all as specified and directed by Engineer- in -chargeNote - Transformer oil filtration and top up shall be measured and paid seperately under the relevant item of schedule
36Transformer capacity 100KVA to 250 KVA
37Transformer capacity 300KVA to 500 KVA
38Disconnecting the HV(22KV) & LV(11KV) side electrical connections including neutral earth strip of existing Power transformer, drain out the complete oil of transformer and store carefully in clean container. Cleaning of all HV/LV windings terminals, cleaning of conservator tank, cooling fins/tubes, tank, etc. Thuroughly inspecting of core and winding complete, and refill the filtered transformer oil upto the desired level marked in conservator tank and record the insulation resistance of the winding both HV/LV side between earth and HV/LV winding, reconnecting the HV/LV side electric cables complete of following capacity of stepdown transformer complete all as specified and directed by Engineer- in -chargeNote - Transformer oil filtration and top up shall be measured and paid seperately under the relevant item of schedule
39M&L for dehydration of transformer oil with mobile stream line transformer oil filteration plant at site with all accessories connected to transformer and carrying out filterartion of oil to desired dielectric strenght to achieve electric strength of 60 KV for 1 minute at 2.5 mm gap as per relevant IS for transformer installed at various locations out door/in door type, complete all as specified and directed by Engineer- in -chargeNote : Test certificate shall be submitted for before and after filteration for dielectric strenght on the proper format. (ii) Transformer oil used for top up will be measured and paid seprately under relevant item.
40Supply and topping up new transformer oil confirming to IS-335 of 1993 into the conservator tank/body tank of the transformer at various location complete all as specified and directed by Engineer- in -charge.Note : The transformer oil for topping up shall be with di-electric strength of 60KV
41Disconnecting all in coming and outdoor cables removing the transformer from the platform/two pole structure and floor and loading it in the vechicle carefully using the crane and transporting it to the workshop for repairs and transformer transport back to site , reinstall it, reconnecting all incoming and outgoing cable by properly crimping using lugs of suitable size taping the bushes/busbar, using insulation tape and testing of capacity 200 KVA to 500 KVA complete all as specified and directed by Engineer- in -charge .Note :LT/HT side ceramic busing, brass spindle for HT/LT side , Rewinding , Dehydration of oil shall be measured and paid seprately in respective Items
42M&L for rewinding of HT /LT windings of transformer , winding the defective coils with approved quality copper wire as per IS of same gauge and existing size together with new insulation materials, bracings the terminals before placing into the tranformer and assembling the HT / LT coil with new insulation between core and LT coil all as required and fitting the coils in the chamber, testing and commisioning the transformer after providing necessary connections complete all as specified and directed by Engineer- in -charge Please Enable Macros to View BoQ information
43M&L for rewinding of HT /LT windings of transformer , winding the defective coils with approved quality copper wire as per IS of same gauge and existing size together with new insulation materials, bracings the terminals before placing into the tranformer and assembling the HT / LT coil with new insulation between core and LT coil all as required and fitting the coils in the chamber, testing and commisioning the transformer after providing necessary connections complete all as specified and directed by Engineer- in -charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56299029
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24.97 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maint/ Of Ht Distribution System,Serving Of Ht Breakers,Vcb And Rmus ,Replacement Ht Ug Cable, Lighting Arrester,God And Repair Of Tranformers At Range Hills Area Under Ge(Mh & Rh) Khadki.
Basic Detail
Tender No CWE/KKE/TOKEN- 18 OF 2026-27
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 03 Jul 2026
Submission Date 28 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value 24.97 Lakhs
Tender Fee 500
EMD 49940
Exemption Available
Document List
af765072-e830-4438-ad89-68a8163a5182.html
BOQ_869381.xls
TENDER.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

af765072-e830-4438-ad89-68a8163a5182.html

xls

BOQ_869381.xls

pdf

TENDER.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders