Tender For Repair/Maint Of Various Dg Sets, Panels And Connected Items At Ralawas Under Ge Banar
Tender Value
15 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
13 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Various Dg Sets, Panels And Connected Items At Ralawas Under Ge Banar
BOQ
| Sl. No. | Item Description |
| 1 | Materials and labour for maintenance and servicing of DG Sets of capacity 500 KVA to 750 KVA complete all as specified and as directed.NOTE: (a) One service of DG Set is termed as ‘EACH JOB’.(b) Minor Spare parts like as rubber gasket,pin,seal etc shall be replaced under servicing without any cost and major parts like as oil filter, diesel filter,air filter & engine oil shall be measured & paid sepratelly under respective items of the schedule as supply only and fixing charge shall be deemed to be inculded in the unit rate of this scedule complete all as specified. |
| 2 | All as per ser item no 1 above but DG set of 125 KVA to 320 KVA |
| 3 | All as per ser item no 1 above but DG set of 30 KVA to 63 KVA |
| 4 | M & L for replacement of Fuel injector pump kit of DG Set of capacity 500 to 750 KVA including strip opening and refixing of plunger, washer manifold, injection nozzles etc. all as required and testing after re-fixing on engine and setting the rated RPM complete all as specified. |
| 5 | All as per ser item no 4 above but DG set of 125 KVA to 320 KVA |
| 6 | All as per ser item no 4 above but DG set of 30 KVA to 63 KVA |
| 7 | M & L in replacement of injector nozzles of DG sets of Capacity 500 to 750 KVA including strip opening and refixing of nozzles, washers, etc. and pressure setting as required for DG Sets of following capacities and replacement of timing shaft with coupling complete all as specified. |
| 8 | All item as per Ser No 8.00 above but DG set of 125 KVA to 320 KVA |
| 9 | All item as per Ser No 8.00 above but DG set of 30 to 63 KVA |
| 10 | Repair of self starter including strip opening and rewinding of armature coil & field coil,for the DG set of capacity 500 to 750 KVA complete all as specified. |
| 11 | All item as per Ser No 10.00 above but DG set of 125 KVA to 320 KVA |
| 12 | All item as per Ser No 10.00 above but DG set of 30 to 63 KVA |
| 13 | M & L for repair of Dynamo including strip opening and rewinding of of armature coil,field coil, bearing etc and other related items as required and re-fixing the same on mountings and testing complete for DG set of capacity 500 to 750 KVA complete all as specified. |
| 14 | All item as per Ser No 14.00 above but DG set of 125 to 320 KVA |
| 15 | All item as per Ser No 14.00 above but DG set of 30 to 63 KVA |
| 16 | M & L for repairing of Automatic voltage regulator, including Diode forward and reverse, rotating rectifier accessories complete to the DG set of capacity 500-750 KVA complete all as specified. |
| 17 | All as per ser item no 12 above but DG set of 125-320KVA |
| 18 | All as per ser item no 12 above but DG set of 30 to 63 KVA |
| 19 | M & L for Strip opening of radiator and cleaning the same by water jet completely and detect the leakage/breakage and repair the radiator by soldering/brazing and testing complete all as specified and as directed for DG set of capacity 500 to 750 KVA complete all as specified. |
| 20 | All item as per Ser No 19.00 above but DG Set of capacity - 125 to 320KVA |
| 21 | All item as per Ser No 19.00 above but DG Set of capacity - 30 to 63 KVA |
| 22 | M and L for taking out burnt out winding and rewinding the alternator main field coil, rotor, exicitor coil, armature with copper enameled wire including other minor repairs, and testing and re-fixing the alternator after repair with alignment rotor with shaft and coupling with all required accessories for 320/250 KVA capacity DG set including necessary electrical and earthing connections complete all as specified. |
| 23 | M and L for taking out burnt out winding and rewinding the alternator main field coil, rotor, exicitor coil, armature with copper enameled wire including other minor repairs, and testing and re-fixing the alternator after repair with alignment rotor with shaft and coupling with all required accessories for 125 KVA capacity DG set including necessary electrical and earthing connections complete all as specified. |
| 24 | M and L for taking out burnt out winding and rewinding the alternator main field coil, rotor, exicitor coil, armature with copper enameled wire including other minor repairs, and testing and re-fixing the alternator after repair with alignment rotor with shaft and coupling with all required accessories for 63/30/40 KVA capacity DG set including necessary electrical and earthing connections complete all as specified. |
| 25 | M & L for coolant including taking out old water/coolent from the tank complete all as specified. |
| 26 | M & L for engine oil of suitable grade including drain out existing used oil complete all as specified. |
| 27 | Supply only Diesel filter of DG set of capacity 500-750 KVA |
| 28 | Supply only Diesel filter of DG set of capacity 125 to 320 KVA |
| 29 | Supply only Diesel filter of DG set of capacity 30 to 63 KVA |
| 30 | Supply only oil filter of DG set of capacity 500-750KVA |
| 31 | Supply only oil filter of DG set of capacity 125 to 320 KVA |
| 32 | Supply only oil filter of DG set of capacity 30 to 63 KVA |
| 33 | M & L for water pump assy for DG Set of capacity 125 to 320 KVA |
| 34 | M & L for water pump assy for DG Set of capacity 30 to 63 KVA |
| 35 | M & L for Radiator hose pipe for DG Set of capacity 125 to 320 KVA |
| 36 | M & L fo Radiator hose pipe for DG Set of capacity 30 to 63 KVA |
| 37 | M & L for Safety control valve DG Set of capacity 500-750 KVA |
| 38 | M & L for Safety control valve DG Set of capacity 125 to 320 KVA |
| 39 | M & L for Safety control valve DG Set of capacity 30 to 63 KVA |
| 40 | M & L for flexible pipe for fuel pump to PT pump incl banjo washer for DG Set |
| 41 | M & L for Air cleaner Filter for DG Set of capacity 500-750 KVA |
| 42 | M & L for Air cleaner Filter for DG Set of capacity 125 to 320 KVA |
| 43 | M & L for Air cleaner Filter for DG Set of capacity 30 to 63 KVA |
| 44 | M & L in replacement for Automatic voltage regulator for DG Set of capacity 125 to 320 KVA |
| 45 | M & L in replacement for Automatic voltage regulator for DG Set of capacity 30 to 63 KVA |
| 46 | M & L in replacement of Self starter for DG set of capacity 125 to 320 KVA as per existing make and cat part no- |
| 47 | M & L in replacement of Self starter for DG set of capacity 30 to 63 KVA as per existing make and cat part no- |
| 48 | M & L in replacement of Dynamo for DG Set of capacity 500 to 750 KVA as per existing make. |
| 49 | M & L in replacement of Dynamo for DG Set of capacity 125 to 320 KVA as per existing make. |
| 50 | M & L in replacement of Dynamo for DG Set of capacity 30 to 63 KVA as per existing make. |
| 51 | M & L for calibration of fuel injector pump on machine complete of capacity 500 to 750 KVA DG set as per existing make. |
| 52 | M & L for calibration of fuel injector pump on machine complete of capacity 125 to 320 KVA DG set as per existing make. |
| 53 | M & L for calibration of fuel injector pump on machine complete of capacity 30 to 63 KVA DG set as per existing make. |
| 54 | Supply and fixing Engine stop solined switch for DG Set of capacity 500 to 750 KVA as per existing make. |
| 55 | Supply and fixing Engine stop solined switch for DG Set of capacity 125 to 320 KVA as per existing make. |
| 56 | Supply and fixing Engine stop solined switch for DG Set of capacity 30 to 63 KVA as per existing make. |
| 57 | Supply and fixing Alternator Fly wheel ring gear for DG Set 125/100/63 as per existing make . |
| 58 | S&F for battery lead with terminal cable of copper conductor size of 19 SWG and 90cmm long as in repair complete all as specified. |
| 59 | M&L for power contactor 4 pole suitable for 125/63 KVA DG set |
| 60 | M&L for power contactor 4 pole for 30/35/40 KVA DG set |
| 61 | M&L for SMPS for 320/250 KVA DG Set AMF panel |
| 62 | M&L for SMPS for 125 KVA DG Set |
| 63 | M&L for SMPS for 30/35/40 KVA DG Set |
| 64 | M&L for current transformer 200/5 A set of three for 750-125 KVA DG set |
| 65 | M&L for current transformer 200/5 A set of three for 63/40/30 KVA Dg set |
| 66 | M&L for selector switch two way for 320/250/125 KVA DG AMF Panel . |
| 67 | M&L for selector switch two way for 63 KVA DG Set |
| 68 | M&L for selector switch two way for 30/35/45 KVA DG set . |
| 69 | M&L for power fuse link with breaking capacity 80 KA for 320/250 KVA DG AMF Panel . |
| 70 | M&L for power fuse link with breaking capacity 80 KA for 63 KVA DG AMF Panel . |
| 71 | M&L for relay with board for 500/750 KVA DG AMF Panel . |
| 72 | M&L for relay with board for 320/250 KVA DG AMF Panel . |
| 73 | M&L for relay with board for 63 KVA DG set |
| 74 | M&L for relay with board for 30/40 KVA DG Set |
| 75 | M&L for controller circuit for 500/750 KVA DG AMF Panel . |
| 76 | M&L for controller circuit for 320/250 KVA DG AMF Panel . |
| 77 | M&L for controller circuit for 30 to 63 KVA DG Set |
| 78 | Supply and fix battery of capacity 180 AH 12V all as specified. Make :- EXIDE/Luminous/Amaron |
| 79 | Supply and fix battery of capacity 150 AH 12V all as specified. Make :- EXIDE/Luminous/Amaron |
| 80 | Supply and fix battery of capacity 120 AH 12V all as specified. Make :- EXIDE/Luminous/Amaron |
| 81 | Supply and fix battery of capacity 100 AH 12V all as specified. Make :- EXIDE/Luminous/Amaron |
| 82 | Supply and fixing in replacement change over (Off Load/On Load type) switch 4 pole, 415 V, 250 Amp complete all as specified. |
| 83 | Supply and fixing in replacement change over (Off Load/On Load type) switch 4 pole, 415 V, 630 Amp complete all as specified. |
| 84 | M & L for repairing of Turbo charger complete for DG Set cap 125 to 320 KVA as per existing make. |
| 85 | M & Lfor repairing of Turbo charger for DG Set cap 30 to 63 KVA as per existing make. |
| 86 | Supply and fixing Amper meter for DG set as per existing make. |
| 87 | Supply and fixing Water temp meter for DG Set as per existing make. |
| 88 | Supply and fixing frequency meter for DG Set as per existing make. |
| 89 | Supply and fixing Volt meter for DG set as per existing make. |
| 90 | M & L for building earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron strip 32x6mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed by Engr-in-Charge |
| 91 | S&F in repair PVC insulated copper conductor multicore FRLS 3 core 4 sqmm for 1100V conforming to IS-694:2010 complete all as specified. |
| 92 | Shifting of existing Diesel Generator (DG) Set of capacity ranging from 40 KVA to 125 KVA from one location to another location within a radius of 3 km, including disconnecting and dismantling all electrical connections, power and control cables, earthing connections, exhaust piping, fuel piping and associated accessories, loading, transportation, unloading, positioning at new location, alignment, refixing on existing/new foundation, reconnecting all cables, earthing and accessories, testing and commissioning complete for satisfactory operation, including all labour, tools & plants, lifting equipment/crane, transportation charges and incidental works complete all as specified. |
| 93 | Supply and fixing of heavy-duty lock and key set for Diesel Generator (DG) Set canopy/ door, including removal of the existing damaged or unserviceable lock, providing new approved quality lock complete with keys, necessary drilling, cutting, fitting, alignment, testing for smooth operation and all labour, tools and incidental materials required for proper installation complete all as specified. |
| 94 | Dismentlling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 95 | S & F Rolled mild steel section as in framing for cladding, glazing & the like fixed with angle cleates & connecting plated etc. fe 410 -W ( gde-E-250) quality -A at height of 8 to 12 mtr complete all as specified. |
| 96 | Dismentling of Plain or Corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof covering complete all as specified. |
| 97 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with hot dip galvanised self drilling fastners with EPDM washers (one fastner on each crest ) complete all as specified. |
| 98 | m & l for Preparation of new ateel surface of any description over 10 cm in width or grith and applying two coat of synthetic enamel paint over priming with redoxide complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender