Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56298976

Tender For Repair/Maint Of Old Rusted Ci/Gi Water Pipeline And Allied Work At Domestic And Tech Area (Including Repair/Maint To Various Swts/Borewells) To Include Cleaning Of Oht/Ug Sumps/Swts And Repairs/Servicing/Rewinding Of Pump & Electric Motors

Issued by Statutory Bodies & Commissions/Committees · Jodhpur, Rajasthan
Tender Value
45 Lakhs
Estimated cost
Bid Submission
25 Jul 2026
15 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Old Rusted Ci/Gi Water Pipeline And Allied Work At Domestic And Tech Area (Including Repair/Maint To Various Swts/Borewells) To Include Cleaning Of Oht/Ug Sumps/Swts And Repairs/Servicing/Rewinding Of Pump & Electric Motors And Allied E/M Works To Water Supply Installations Including Repair/Maint Of Fountains And Old/Rusted Gi/Ci Pipeline Work Under Aor Of Age E/M Ge (Af) No 2 At Af Stn Jodhpur Under Age E/M, Ge (Af) No 2 Jodhpur

BOQ

Name of Work:- REPAIR/MAINT OF OLD RUSTED CI/GI WATER PIPELINE AND ALLIED WORK AT DOMESTIC AND TECH AREA (INCLUDING REPAIR/MAINT TO VARIOUS SWTS/BOREWELLS) TO INCLUDE CLEANING OF OHT/UG SUMPS/SWTS AND REPAIRS/SERVICING/REWINDING OF PUMP & ELECTRIC MOTORS AND ALLIED E/M WORKS TO WATER SUPPLY INSTALLATIONS INCLUDING REPAIR/MAINT OF FOUNTAINS AND OLD/RUSTED GI/CI PIPELINE WORK UNDER AOR OF AGE E/M GE (AF) NO 2 AT AF STN JODHPUR UNDER AGE E/M, GE (AF) NO 2 JODHPUR
Sl. No. Item Description
1Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, pier holes, for foundations of poles, struts, stays etc. or laying underground cable and water supply pipe lines etc. in hard/dense soil/rocks, & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
2Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil/\ complete all as specified and directed by Engineer-in-charge.
3Removal of excavated soil material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
4Taking up or down 15mm bore galvanised steel water tubing including connections, fixed in walls, ceiling or laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge. Note :-Excavation and earthwork shall be measured and paid for separately.
5All as per Srl item No 4 above but 20 mm dia bore.
6All as per Srl item No 4 above but 25 mm dia bore.
7All as per Srl item No 4 above but 40 mm dia bore.
8All as per Srl item No 4 above but 50 mm dia bore.
9Taking up or down 80 mm bore CI/DI/GI water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead, laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge. Note :-Excavation and earthwork shall be measured and paid for separately.
10All as per Srl item No 09 above but 100 mm dia bore.
11All as per Srl item No 99 above but 150 mm dia bore.
12S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
13All as per Srl item No 12 above but 20 mm dia bore.
14All as per Srl item No 12 above but 25 mm dia bore.
15All as per Srl item No 12 above but 40 mm dia bore.
16S&F 50mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge.
17All as per Srl item No 16 above but 80 mm dia bore.
18Supplying, laying, jointing, commissioning and testing 100mm bore centrifugally cast (Spun) ductile iron pressure pipe with spigot and socketed ends class K-7, confirming to IS : 8329/2000 blast furnace slag cement with portland cement properties suitable for rubber gasket jointing / tyton joints with inside cement mortar lining and black bitumen external coating, duly (ISI marked) laid in trenches complete all as specified and directed by Engineer-in-Charge. Note :- (i) DI fittings shall be measured and paid separately under respective items (ii) Pipes shall be laid in trenches already excavated for taking out old GI pipe line. Extra excavation / earthwork shall not be paid.
19All as per Srl item No 18 above but 150 mm dia bore.
20S&F in replacement gun metal globe or gate valve 15mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
21All as per Srl item No 20 above but 20 mm dia bore.
22All as per Srl item No 20 above but 25 mm dia bore.
23All as per Srl item No 20 above but 40 mm dia bore.
24All as per Srl item No 20 above but 50 mm dia bore.
25Supplying, fixing and testing in replacement of 80mm bore cast iron sluice valve with flanged ends drilled ISI marked conforming Class PN 1.6 to IS 14846-2000 with stainless steel spindle with iron wheel, CI gate with brass nut, bolts, washers and rubber packing for connecting pieces etc complete all as specified and as directed by Engineer-in-Charge.
26All as per Srl item No 25 above but 100 mm dia bore.
27All as per Srl item No 25 above but 150 mm dia bore.
28All as per Srl item No. 25 above but size of 200mm
29S&F Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 80mm bore pipe, ISI marked, conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc complete all as specified and directed by Engineer-in-charge.
30All as per Srl item No 29 above but 100 mm dia bore.
31All as per Srl item No 29 above but 150 mm dia bore.
32Supply and fix Foot Valve conforming to IS 4038, 80 mm (4”) dia complete all as specified and directed by Engineer-in-charge.
33All as per Srl item No. 32 abov but size of 100mm
34All as per Srl item No. 32 abov but size of 150mm
35S&F in replacement 80mm dia butterfly valve complete all as specified and directed by Engineer-in-charge.
36All as per Srl item No 35 above but 100 mm dia bore.
37All as per Srl item No 35 above but 150 mm dia bore.
38S & F in repair 15mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed all as specified and directed.
39All as per Srl item No 38 above but 20 mm dia bore.
40All as per Srl item No 38 above but 25 mm dia bore.
41Supplying & fixing DI fittings confirming to IS-9523-2000 suitable for spigot & socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc),tee pieces, single branch, 'Y' junction, double branch, cross collar, caps and plugs etc. suitable for spigot and socketed pipes upto 150 mm bore, complete, all as specified and directed by Engineer-in-charge.
42M&L for Construction of brick masonry valve pit, in repair, of internal size 60cm x 60cm x 60cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock , complete all as specified and directed by Engineer - in - Charge Note :- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds.(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit.(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation
43All as per Srl item No 42 above but internal size 90cm x 90cm x 90cm
44All as per Srl item No 42 above but internal size 150cm x 150cm x 90cm
45M&L for 'D' Joint suitable for DI /CI/GI pipe sizes 50 mm dia bore including excavation work and other fittings as required including testing at site complete all as specified and directed by the Engineer-in-Charge.
46All as per Srl item No 45 above but 80 mm dia bore.
47All as per Srl item No 45 above but 100 mm dia bore.
48All as per Srl item No 45 above but 150 mm dia bore.
49M&L for Cleaning of RCC overhead reservoir upto 25000 gallon capacity at 60 feet staging by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge with and including writing capacity of tank , date of cleaning of tank with synthetic enamel paint on outer surface of the tank complete all as specified and as directed by Engineer-in-Charge.
50All as per Srl item No 49 above but RCC overhead reservoir of capacity exceeding 25000 gallon and not exceeding 0.5 Lakh gallon capacity at 60 feet
51All as per Srl item No 49 above but RCC overhead reservoir of capacity exceeding 50000 gallon and not exceeding 1.5 Lakh gallon capacity at 60 feet
52M&L for Cleaning of RCC underground sump upto 50000 gallon capacity at 20 feet depth by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge with and including writing capacity of tank , date of cleaning of tank with synthetic enamel paint on outer surface of the tank complete all as specified and as directed by Engineer-in-Charge.
53All as per Srl item No 52 above but RCC underground sump of capacity exceeding 0.5 lakh gallon and not exceeding 1 Lakh gallon capacity at 20 feet depth
54All as per Srl item No 52 above but RCC underground sump of capacity exceeding 1 lakh gallon and not exceeding 2.5 Lakh gallon capacity at 20 feet depth
55M&L for Cleaning of clarifloculator of Cap 100000 Glns by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and Greasing all components by replacing the worn nut bolts of non clogging pump motor, and removing all the sludge dirt and deposits of any foreign materials etc. , painting of all the steel member channels, angles of the scrappers and mixers with two coats of bituminous based paint after preparation of old painted surface all as specified and directed by Engr-in-Charge.
56M&L Cleaning of RCC raw water (back wash) sumps cap 25000 gln by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge
57M&L Cleaning of RCC raw water (back wash) sumps cap upto 10000 gln by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge
58M&L Cleaning of RCC sedimentation sumps cap 50000 gln by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge
59Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
60Cleaning of SWTs upto 15000 GLN capacity by continues dewatering till the complete cleaning of SWTs by using suitable capacity non clog diesel engine pump set and removing all the accumulated sediments, foreign particles etc including scrubbing, brushing and removing all the dirt/sludge accumulated on the walls/floor etc as required all as directed by Engr In Charge.
61Supply only Water treatment Calcium hypo Chloride 65%-70% chlorine content (calcium based granular disinfectant for water treatment, packed in 45 kg drum complete.
62Supply only Water treatmentbleaching Powder 25 Kg bag complete all as specified and as directed.
63M&L for taking out defictive submersible pump set of capacity 5 / 7.5 HP Capacity from bore well after disconnecting electrical connections, transportation to workshop for repair, dismantling the pump set for detection of repair such as rewinding of motor, replacement of iron stainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key, thrust bearing, replacement of unserviceable nut-bolts, washer, lugs, terminal plate, reassembling, lowering in well in its original position, making proper electrical connections, commissioning & testing complete all as specified and directed by Engineer-in-charge Note : - (i) Cost for transportaion to workshop and carry back to site after repair is inlcuded in the unit rate of item nothing extra shall be paid on this acount. (ii) Rewinding of submersible motor, Iron stainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key and thrust bearing if required for replacement shall be paid separetly against respective items of BOQ as \\"Supply only\\". (iii) Lathe work and grinding of shaft if required shall be paid separately against respective items of BOQ. (iv) Cost of new nuts, bolts, washers, lugs and terminal plate required to be replaced is included in the unit rate of this item nothing extra shall be paid on this account.
64All as per serial item No. 63 here-in-above but submersible pump set of capacity 10 / 12.5 HP
65M&L for rewiding of submersible pump set of capacity 5 / 7.5 HP with PVC insulated copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts complete all as specified and as directed by Engineer –in-charge
66All as per serial item No. 65 here-in-above but submersible pump set of capacity 10 / 12.5 HP
67Supply only Iron stainer suitable for submersible pump of capacity 5 /7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
68Supply only Iron stainer suitable for submersible pump of capacity 10/ 12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
69Supply only Gun metal Bush suitable for submersible pump of capacity 5 / 7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
70Supply only Gun metal Bush suitable for submersible pump of capacity 10 /12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
71M&L for taking out of Elect Motor 75 HP Capacity installed as motor from foundation after disconnecting electrical connections, dismantling motor and rewiding the same with super enamelled copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts, reassembling and fixing the same in its original position including replacement of unserviceable nut-bolts, washer, lugs, terminal plate and making proper electrical connection complete all as specified and directed by Engineer-in-charge. Note : - (i) Bearing if required for replacement shall be paid seprately (ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account
72All as per serial item No. 71 here-in-above but motor of capacity 50 HP
73All as per serial item No. 71 here-in-above but motor of capacity 20 HP
74All as per serial item No. 71 here-in-above but motor of capacity 15 HP
75All as per serial item No. 71 here-in-above but motor of capacity 10/12.5 HP
76All as per serial item No. 71 here-in-above but motor of capacity 7.5 HP
77All as per serial item No. 71 here-in-above but motor of capacity 5 HP
78All as per serial item No. 71 here-in-above but motor of capacity 3 HP
79All as per serial item No. 71 here-in-above but motor of capacity 2 /1 HP
80Taking out centrifugal motor of any capacity from foundation, dismantling the motor, taking out rotor and filling the material by welding work, finishing by lathe machine, replacement of unserviceable bearing, reassembling the motor and fixed in its original position complete all as specified and directed by Engineer-in-charge. Note: - (i) Bearing shall be measured and paid for separately as “Supply only” (ii) New Nuts, bolts and washers if required for refixing the motor shall be provided by the contractor, nothing extra shall be paid on this account.
81Supply only Ball Bearing of suitable size for rotor of motor 75 HP installed complete all as specified and directed by Engineer-in-charge.
82All as per serial item No 80 here-in-above but for motor of 50 HP.
83All as per serial item No 80 here-in-above but for motor of 20 HP.
84All as per serial item No 80 here-in-above but for motor of 15 HP.
85All as per serial item No 80 here-in-above but for motor of 10 /12.5 HP.
86All as per serial item No 80 here-in-above but for motor of 7.5 HP.
87All as per serial item No 80 here-in-above but for motor of 5 HP.
88All as per serial item No 80 here-in-above but for motor of 3 HP.
89All as per serial item No 80 here-in-above but for motor of 1/ 2 HP.
90Taking out defective centrifugal pump set , assembled with 75 HP elelctric motor, dismantling the pump set for carrying out repair / replacement of unserviceable parts such as CI impeller, Bush, ball bearing etc. reassembling, installing, commissioning and testing complete all as specified and directed by Engineer-in-charge. Note :(i) CI impeller, Bush & ball bearing required to replace shall be measured and paid for separately under respective items of BOQ as “Supply only”.(ii) The cost of transportation is included in the unit rate of this item nothing extra shall be paid on this account
91All as per serial item No 90 here-in-above but pump set assembled with 50 HP elelctric motor
92All as per serial item No 90 here-in-above but pump set assembled with 20 HP elelctric motor
93All as per serial item No 90 here-in-above but pump set assembled with 15 HP elelctric motor
94All as per serial item No 90 here-in-above but pump set assembled with 10 /12.5 HP elelctric motor
95All as per serial item No 90 here-in-above but pump set assembled with 7.5 HP elelctric motor
96All as per serial item No 90 here-in-above but pump set assembled with 5 HP elelctric motor
97All as per serial item No 90 here-in-above but pump set assembled with 2 /3 HP elelctric motor
98Supply only ball bearing suitable for centrifugal Pump set assembled with 75 HP motor complete all as specified and directed by Engineer-in-charge.
99All as per serial item No 98 here-in-above but assembled with 50 HP Motor
100All as per serial item No 98 here-in-above but assembled with 20 HP Motor
101All as per serial item No 98 here-in-above but assembled with 15 HP Motor
102All as per serial item No 98 here-in-above but assembled with 10 /12.5 HP Motor
103All as per serial item No 98 here-in-above but assembled with 7 .5 HP Motor
104All as per serial item No 98 here-in-above but assembled with 5 HP Motor
105All as per serial item No 98 here-in-above but assembled with 3 HP Motor
106Supply only stainless steel Bush suitable for pump set assembled with 75 HP motor complete all as specified and directed by Engineer-in-charge.
107All as per serial item No 106 here-in-above but assembled with 50 HP Motor
108All as per serial item No 106 here-in-above but assembled with 20 HP Motor
109All as per serial item No 106 here-in-above but assembled with 10 / 12.5 HP Motor
110All as per serial item No 106 here-in-above but assembled with 7.5 HP Motor
111All as per serial item No 106 here-in-above but assembled with 5 HP Motor
112Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 16 Sqmm 3 core complete all as specified & as directed by Engineer –in-charge.
113All as per serial item No.112 here-in-above but 10 Sqmm 3 core.
114All as per serial item No.112 here-in-above but 6 Sqmm 3 core.
115All as per serial item No.112 here-in-above but 4 Sqmm 3 core.
116S&F as in replacement coupling assembly as per existing model & make suitable for centrifugal pump set assembled with 75 HP motor complete all as specified & as directed by Engineer –in-charge.
117All as per serial item No. 116 here-in-above but assembled with 50 HP motor
118All as per serial item No. 116 here-in-above but assembled with 20 HP motor
119All as per serial item No. 116 here-in-above but assembled with 15 HP motor
120S&F in replacement rubber coupling as per existing model & make suitable for centrifugal pump set assembled with 75 HP motor complete all as specified & as directed by Engineer –in-charge.
121All as per serial item No. 120 here-in-above but assembled with 50HP motor
122All as per serial item No. 120 here-in-above but assembled with 20/30HP motor
123All as per serial item No. 120 here-in-above but assembled with 15/10/7.5 HP motor
124All as per serial item No. 120 here-in-above but assembled with 5 HP motor
125S&F in replacement bakelite sheet of connection plate with cable connector suitable for 75 / 50 HP motor complete all as specified & as directed by Engineer –in-charge.
126All as per serial item No. 125 here-in-above but suitable for 20 / 12.5 /10 HP motor
127S&F in replacement cooling fan with locking aluminum cast type screw, as per existing type, suitable for 75 / 50 HP motor complete all as specified & as directed by Engineer –in-charge.
128All as per serial item No. 127 here-in-above but suitable for 25 / 20 / 12.5 HP motor
129All as per serial item No. 127 here-in-above but suitable for 10 / 7.5 HP motor
130All as per serial item No. 127 here-in-above but suitable for 5 HP motor
131S&F gland rope of size 10 sqmm or as required complete all as specified & as directed by Engineer –in-charge
132S&F in replacement contactor ML-2, 3 phase 415 volts having auxillary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 110 Amps complete all as specified and as directed by Engineer –in-charge.
133S&F in replacement contactor ML-3, 3 phase 415 volts having auxillary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 110 Amps complete all as specified and as directed by Engineer –in-charge.
134S&F in replacement contactor MNX80, 3 phase 415 volts having auxillary contracts suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge.
135S&F in replacement contactor MNX110, 3 phase 415 volts having auxillary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge.
136S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
137S&F in replacement Digital type Ammeter 96mm x 96 mm, single phase,as suitable range, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
138S&F in replacement oveload relay, suitable for 10 HP to 40 HP motor, 3 phase, 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge
139S&F in replacement oveload relay, suitable for 50HP to 75 HP , motor 3, phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
140S&F in soft starter, suitable for 15 HP pumpset ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
141S&F in soft starter, suitable for 50 HP pumpset ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
142S&F in replacement fully automatic star delta starter type ML2 FASD having relay of range 20 - 32 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
143S&F in replacement fully automatic star delta starter type for 10 HP having relay of range 08 - 12 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
144S&F in replacement DOL starter range 13 - 22 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
145S&F in replacement DOL Starter range 28 - 42 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
146S&F in replacement single phase preventer type SDz5, SPPR + Timer, 415 V including necessary copper connection, lugs etc complete all as specified & as directed by Engineer-in-charge
147S&F in replacement electronic timer type ET100, 110 / 240V, 50 HZ including necessary electric connection complete all as specified & as directed by Engineer-in-charge
148S&F in replacement on / off switch (push button) complete all as specified & as directed by Engineer-in-charge
149S&F in replacement indicating lamp with holder and cover as per existing complete all as specified & as directed by Engineer-in-charge
150S&F in replacement of Aviation obstruction light, LED type, AC 220 Volts as per existing complete all as specified & as directed by Engineer-in-charge
151S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge.
152All as per item No. 151 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt
153All as per item No. 151 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 25 KA, 415 Volt
154All as per item No. 151 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt
155All as per item No. 87 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt
156Preparation of old painted steel surfaces of panel body of any size incl scrapping old paint, denting and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
157M&L for complete removal of existing paint of Elect motor with pump including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
158M&L for complete removal of existing paint of pipeline of dia 80mm to 150mm, including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
159M&L for complete removal of existing paint of pipeline of dia 200mm to 350mm, including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
160Repair/remarking to existing scale and indicator (water level indicator of RCC UG reservoir or over head reservoir) with & connecting wire & synthetic enamel paint as per colour code and as directed by Engr-in-Charge.
161Material and labour in repair for over hauling/ lubrication emtork actuator valves Model No : M1/030/A and M0/030/E including replacement of unserviceable spare parts. complete entire satisfaction of Engr in charge.
162S&F in repair fan belt B-32 of air compressor.The fan belt B-32 shall be ISI marked best quality and shall be approved by GE before incorporation in the work complete all as specified and directed by Engineer-in-charge.
163Supply and fix pressure gauge air water meter of pressure range 0-10 kg/Sqcm complete all as specified and directed by Engineer-in-charge.
164M & L for Earthing complete with copper plate 60×60cm.× 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
165S&F XLPE insulated, armoured heavy duty electric cable withaluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3 1/2 core. complete all as specified & as directed by Engineer –in-charge. S&F in repair fan belt B-32 of air compressor.The fan belt B-32 shall be ISI marked best quality and shall be approved by GE before incorporation in the work complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56298976
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 25-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Old Rusted Ci/Gi Water Pipeline And Allied Work At Domestic And Tech Area (Including Repair/Maint To Various Swts/Borewells) To Include Cleaning Of Oht/Ug Sumps/Swts And Repairs/Servicing/Rewinding Of Pump & Electric Motors And Allied E/M Works To Water Supply Installations Including Repair/Maint Of Fountains And Old/Rusted Gi/Ci Pipeline Work Under Aor Of Age E/M Ge (Af) No 2 At Af Stn Jodhpur Under Age E/M, Ge (Af) No 2 Jodhpur
Basic Detail
Tender No 8609/E8
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 03 Jul 2026
Submission Date 25 Jul 2026
Open Date 27 Jul 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
0e374368-daa9-45e9-aa99-db98e63a8f3c.html
BOQ_869246.xls
tenderdocument.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

0e374368-daa9-45e9-aa99-db98e63a8f3c.html

xls

BOQ_869246.xls

pdf

tenderdocument.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders