Tender For S : - Repair & Maintenance Of Dg Sets And Allied Works And Repair/Maint Of Vcbs, Lt Panels, Ht/Lt Switchgear And Cable And Allied Works Under Ge (West) Jabalpur
Tender Value
93.80 Lakhs
Estimated cost
Bid Submission
24 Jul 2026
3 days left
EMD
1.66 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for S : - Repair & Maintenance Of Dg Sets And Allied Works And Repair/Maint Of Vcbs, Lt Panels, Ht/Lt Switchgear And Cable And Allied Works Under Ge (West) Jabalpur
BOQ
| Sl. No. | Item Description |
| 1 | Comprehensive/periodical maintenance of DG Set on quarterly basis including checking, cleaning, adjusting/tightening, oiling, greasing and resetting of existing part decarbonising of battery terminals of DG Set at different location of installation and keep ready to set for proper functioning of valve 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbon brushes, vibration dampers, coupling, alternator terminals, springs, AVR's, exhaust pipes etc of following capacity of DG Sets :-Note:- Spares part shall be measured and paid separately under respective item of Sch A. |
| 2 | (a) 1010 KVA capacity |
| 3 | (b) 600 KVA capacity |
| 4 | (c) 320 KVA capacity |
| 5 | (d) 250 KVA capacity |
| 6 | (e) 100 KVA to 160 KVA capacity |
| 7 | (f) 60 KVA to 82.5 KVA capacity |
| 8 | (g) 40 KVA capacity |
| 9 | (h) 20 to 30 KVA capacity |
| 10 | (j) 4.2 KVA capacity |
| 11 | Opening the nut bolts and taking out the engine head assembly/ FIP / Engine assembly of 20/30 KVA of any make other connected items and taking out u/s item to with transporting the Engine assembly to workshop and return back after repair, assembling the items and testing commissioning to entire satisfaction of suitable make & model complete all as specified & directed. Note:- Items required to be repair are paid seperately |
| 12 | Replacement of following unserviceable parts / items from the engine / alternator of diesel engine driven generating set of 20 KVA to 30 KVA capacity, 4-cyllinder of following items all as specified & directed. Note:- Items required to be paid under supply only |
| 13 | (a) Complete exhaust silencer (absorption type) |
| 14 | (b) Adopter for absorption type silencer |
| 15 | (c) Fuel pipe for feed pump to filter |
| 16 | (d) Fuel pipe for diesel tank to feed pump |
| 17 | (e) Fuel pipe for filter to fuel pump |
| 18 | (f) Banjo bolt with washers for fuel pipe |
| 19 | (g) Oil filter element complete (MICO, BOSCH or equivalent) |
| 20 | (h) Diesel filter elements complete (MICO, BOSCH or equivalent) |
| 21 | (j) Flexible pipe (filter to lub oil cooler) |
| 22 | (k) Exhaust valve |
| 23 | (l) Inlet Valve |
| 24 | (m) Guide head spring |
| 25 | (n) Piston with ring set complete |
| 26 | (o) Packing kit with O ring |
| 27 | (p) Complete radiator suitable for upto 30 KVA DG set |
| 28 | (q) Water lifting pump for 20/30 KVA DG set single phase |
| 29 | (r) Battery Charger for Alternator 12 volts complete. |
| 30 | (s) V belt of suitable size make: Fanner or equivalent as approved by GE. |
| 31 | (t) Rocker cover assembly 20 to 30 KVA |
| 32 | (u) Front and rear oil seal 20 to 30 KVA |
| 33 | (v) High coolant temperature sensor 20 to 30 KVA |
| 34 | (w) Low lube oil pressure sensor 20 to 30 KVA |
| 35 | (x) Low lube oil pump 20 to 30 KVA |
| 36 | Opening the nut bolts and taking out the engine head assembly / FIP / Engine assembly of 40 / 62.5 KVA of any make other connected items and taking out u/s item to with transporting the Engine assembly to workshop and return back after repair assembling the items and testing commissioning to entire satisfaction of suitable make & model complete all as specified & directed. Note:- Items required to be repair are paid seperately |
| 37 | Replacement of following unserviceable parts / items from the engine / alternator of diesel engine driven generating set of 40/62.5 KVA capacity, 4-cyllinder of following item all as specified & directed.Note:- Items required to be paid under supply only |
| 38 | (a) Complete exhaust silencer (absorption type) |
| 39 | (b) Adopter for absorption type silencer |
| 40 | (c) Fuel pipe for feed pump to filter |
| 41 | (d) Fuel pipe for diesel tank to feed pump |
| 42 | (e) Fuel pipe for filter to fuel pump |
| 43 | (f) Banjo bolt with washers for fuel pipe |
| 44 | (g) Oil filter element complete (MICO, BOSCH or equivalent) |
| 45 | (h) Diesel filter elements complete (MICO, BOSCH or equivalent) |
| 46 | (j) Flexible pipe (filter to lub oil cooler) |
| 47 | (k) Exhaust valve |
| 48 | (l) Inlet Valve |
| 49 | (m) Guide head spring |
| 50 | (n) Piston with ring set complete |
| 51 | (o) Packing kit with O ring |
| 52 | (p) Complete radiator suitable for upto 62.5 KVA DG set |
| 53 | (q) Water lifting pump for 40/ 62.5KVA DG set single phase |
| 54 | (r) Battery Charger for Alternator 12 volts complete. |
| 55 | (s) V belt of suitable size make: Fanner or equivalent as approved by GE. |
| 56 | (t) Rocker cover assembly 40 to 62.5 KVA |
| 57 | (u) Front and rear oil seal 40 to 62.5 KVA |
| 58 | (v) High coolant temperature sensor 40 to 62.5 KVA |
| 59 | (w) Low lube oil pressure sensor 40 to 62.5 KVA |
| 60 | (x) Low lube oil pump 40 to 62.5 KVA |
| 61 | Opening the nut bolts and taking out the engine head assembly/ FIP / Engine assembly of 82.5 / 125/160 KVA of any make other connected items and taking out u/s item to with transporting the Engine assembly to workshop and return back after repair assembling the items and testing commisioning to entire satisfaction of suitable make & model complete all as specified & directed. note Items required to be repair are paid seperately |
| 62 | Replacement of following unserviceable parts / items from the engine / alternator of diesel engine driven generating set of 82.5 / 125/160 KVA capacity, 4-cyllinder of following item all as specified & directed.Note :Items required to be paid under supply only |
| 63 | (a) Fuel pipe for feed pump to filter |
| 64 | (b) Fuel pipe for diesel tank to feed pump |
| 65 | (c) Fuel pipe for filter to fuel pump |
| 66 | (d) Banjo bolt with washers for fuel pipe |
| 67 | (e) Oil filter element complete (MICO, Bosch or equivalent) |
| 68 | (f) Diesel filter elements complete (MICO, Bosch or equivalent) |
| 69 | (g) Flexible pipe (filter to lub oil cooler) |
| 70 | (h) Exhaust valve |
| 71 | (j) Inlet Valve |
| 72 | (k) Guide head spring |
| 73 | (l) Piston with ring set complete |
| 74 | (m) Packing kit with O ring |
| 75 | (n) Water lifting pump for DG set single phase |
| 76 | (o) Battery Charger for Alternator 12 volts complete make: Lucas /TVS /BOSCH |
| 77 | (p) V belt of suitable size make: Fanner or equivalent as approved by GE. |
| 78 | (t) Rocker cover assembly 82.5 to 250 KVA |
| 79 | (u) Front and rear oil seal 82.5 to 250 KVA |
| 80 | (v) High coolant temperature sensor 82.5 to 250 KVA |
| 81 | (w) Low lube oil pressure sensor 82.5 to 250 KVA |
| 82 | (x) Low lube oil pump 82.5 to 250 KVA |
| 83 | Opening the nut bolts and taking out the engine head assembly/ FIP / Engine assembly of 320 KVA of any make other connected items and taking out u/s item to with transporting the Engine assembly to workshop and return back after repair assembling the items and testing commisioning to entire satisfaction of suitable make & model complete all as specified & directed.Note: Items required to be repair are paid seperately |
| 84 | Replacement of following unserviceable parts / items from the engine / alternator of diesel engine driven generating set of 320 KVA capacity, 4-cyllinder of following item all as specified & directed.Note :Items required to be paid under supply only |
| 85 | (a) Fuel pipe for feed pump to filter |
| 86 | (b) Fuel pipe for diesel tank to feed pump |
| 87 | (c) Fuel pipe for filter to fuel pump |
| 88 | (d) Valve sheet |
| 89 | (e) Oil filter element complete (MICO, Bosch or equivalent) |
| 90 | (f) Diesel filter elements complete (MICO, Bosch or equivalent) |
| 91 | (g) Flexible pipe (filter to lube oil cooler) |
| 92 | (h) Exhaust valve |
| 93 | (j) Inlet valve. |
| 94 | (k) Guide head spring |
| 95 | (l) Packing kit with O ring |
| 96 | (m) Water lifting pump for DG set single phase |
| 97 | (n) Battery Charger for Alternator 24 volts complete make: Lucas /TVS /BOSCH |
| 98 | (o) V belt of suitable size make: Fanner or equivalent as approved by GE. |
| 99 | (p) Hose pipe set complete. |
| 100 | (t) Piston Ring |
| 101 | (t) Rocker cover assembly 320 to 1010 KVA |
| 102 | (u) Front and rear oil seal 320 to 1010 KVA |
| 103 | (v) High coolant temperature sensor 320 to 1010 KVA |
| 104 | (w) Low lube oil pressure sensor 320 to 1010 KVA |
| 105 | (x) Low lube oil pump 320 to 1010 KVA |
| 106 | Repair and replacement of complete wiring of existing panel board including replacement of Ammeter, temperature meters, oil pressure gauge and ignition switch complete etc all as directed for 40 KVA to 62.5 KVA DG set |
| 107 | Repair and replacement of complete wiring of existing panel board including replacement of Ameter, temprature meters,oil pressure gauge and ignition switch complete etc all as directed.for 82.5 KVA to 250 KVA DG set |
| 108 | Repair and replacement of complete wiring of existing panel board including replacement of Ameter, temprature meters,oil pressure gauge and ignition switch complete etc all as directed.for 320 KVA DG set . |
| 109 | Supply & Fixing in repair Panel board assembly tray type including complete wiring of existing panel board including replacement of Ameter, temperature meters, oil pressure meter and ignition switch complete etc all as specified & directed for 20 to 30 KVA. |
| 110 | Supply & Fixing in repair Alternator for battery charging 12/24 volts complete etc all as specified and directed. |
| 111 | Supply & Fixing in repair of blower type (fan blade) for radiator complete of DG set 20 to 30 KVA capacity complete etc all as specified and directed. |
| 112 | Taking down carefully and repairing of Alternator of DG set of 40 KVA capacity and transportation to authorised workshop for rewinding with super enameled copper wire including boosted coil and replacement of bearings / slip rings as per existing size & make including commissioning & testing complete etc all as specified & directed. |
| 113 | Taking down carefully and repairing of Alternator of DG set of 62.5 / 82.5 KVA capacity and transportation to authorised workshop for rewinding with super enameled copper wire including boosted coil and replacement of bearings / slip rings as per existing size & make including commissioning & testing complete etc all as specified & directed. |
| 114 | Taking down carefully and repairing of Alternator of DG set of 20 / 30 KVA capacity of any make and transportation to authorised workshop for rewinding with super enameled copper wire including boosted coil and replacement of bearings / slip rings as per existing size & make including commissioning & testing complete etc all as specified & directed. |
| 115 | Taking out carefully and repairing of fuel injection pump assembly complete from the engines of following capacity of DG sets including maintenance, servicing, replacement of valves, washers etc re-assembling calibration, setting for proper function, refixing and testing complete all as specified & directed:- |
| 116 | (a) 20 /30 KVA capacity |
| 117 | (b) 40 KVA capacity |
| 118 | (c) 62.5 to 82.5 KVA capacity |
| 119 | (d) 100/125/160 KVA capacity |
| 120 | (e) 320 KVA capacity (PT Pump) including barrel sleeves, spring, gear, pump etc complete all as specified and directed. |
| 121 | (f) 600 KVA capacity (PT Pump) including barrel sleeves, spring, gear, pump etc complete all as specified and directed. |
| 122 | (g) 1000 KVA capacity (Gear Pump) including barrel sleeves, spring, gear, pump etc complete all as specified and directed. |
| 123 | (g) S&F in repair of primary fuel Pump 1010 KVA DG Set complete all as specified and directed. |
| 124 | Calibration of nozzles (fuel injector) of fuel injection pump assembly complete of following capacity DG sets, setting for proper functioning, refixing and testing complete etc all as specified & directed. |
| 125 | (a) 20/30 KVA capacity |
| 126 | (b) 40 KVA capacity |
| 127 | (c) 62.5 KVA capacity |
| 128 | (d) 82.5 KVA capacity |
| 129 | (e) 100/125/160 KVA capacity |
| 130 | (f) 320 KVA capacity (Barrel, plunger, cup, screen filter, oriface and non stop zero less type fuel injector) complete all as specified and directed. |
| 131 | (g) 600 KVA capacity (Barrel, plunger, cup, screen filter, oriface and non stop zero less type fuel injector) complete all as specified and directed. |
| 132 | (h) 1000 KVA capacity (ECM operated electric fuel injector and pressure testing) |
| 133 | Supply & fixing in repair ECM operated electric fuel injector nozzle complete all as required & as directed for 1010 KVA capacity DG SET. |
| 134 | Supply & fixing in repair of Brass Nozzle with ring suitable size for fixing complete etc all as required & as directed for 20 to 250 KVA capacity DG SET. |
| 135 | Dismantling & taking out carefully, reparing and removing the alternator / dynamo from the engine of following capacity of DG sets with opening up, cleaning / servicing and replacement of carbon brushes with holder and assembling back, refixing and testing complete etc all as specified & directed. |
| 136 | (a) 40 KVA capacity |
| 137 | (b) 62.5 / 82.5 KVA capacity |
| 138 | (c) 100/125/160 KVA capacity |
| 139 | (d) 320 KVA capacity |
| 140 | (e) 20/30 KVA capacity |
| 141 | (f) 600 KVA capacity |
| 142 | (g) 1010 KVA capacity |
| 143 | Taking out carefully for repairing the radiator assembly from the engine of following capacity of DG sets by disconnecting of inlet and outlet and over-hauling / servicing the radiator cleaning / removing blockage arresting leakage with necessary welding / brazzing as required and fixing back in its position for testing complete etc all as specified & directed. |
| 144 | (a) 40 KVA capacity |
| 145 | (b) 62.5 /82.5 KVA capacity |
| 146 | (c) 125/160 KVA capacity |
| 147 | (e) 20/30 KVA capacity |
| 148 | Dismantling and taking out the necessary connection carefully from MS fuel tank of any size / type of DG set by disconnecting of fuel pipes connections, draining out of fuel from the tank, cleaning & removing sediments, dirt etc from fuel tank and replacement of fuel pipe line with highly transparent PVC flexible threaded pipes of suitable size including painting of outer surface of fuel tank with synthetic enamel paint of one coat after cleaning, scrubbing the surfaces and writing the capacity of fuel tank and marking fuel level position with synthetic enamel paint for the following DG sets:- |
| 149 | (a) 40 KVA capacity |
| 150 | (b) 62.5 KVA capacity |
| 151 | (c) 82.5 KVA capacity |
| 152 | (d) 125/160 KVA capacity |
| 153 | (e) 320 KVA capacity |
| 154 | (f) 20 / 30 KVA capacity |
| 155 | (g) 600 KVA capacity |
| 156 | (h) 1010 KVA capacity |
| 157 | Repair / maintenance of exhaust system including replacement of exhaust pipe, bracket with clamps, nut bolt and washer, exhaust manifold packing etc of any capcity of DG Set, all as specified and directed by Engr-in-Charge. |
| 158 | Painting of DG Sets of following capacities, comprising Engine, Alternator, LT Panel board as per standard/approved colour code with one coat of synthetic enamel paint after cleaning, scrubbing of all surfaces incl writing SM and MES Number etc all as specified and directed for:- |
| 159 | (a) 125/160 KVA Capacity |
| 160 | (b) 62.5 KVA Capacity |
| 161 | (c) 82.5 KVA Capacity |
| 162 | (d) 40 KVA capacity |
| 163 | (e) 20/30 KVA capacity |
| 164 | S & F in replacement battery cables of following sizes complete etc all as specified and directed. |
| 165 | (a) Copper cable suitable for DG set 1010 KVA |
| 166 | (b) Copper cable suitable for DG set 600 KVA |
| 167 | (c) Copper cable suitable for DG set 320 KVA |
| 168 | (d) Copper cable suitable for DG set 40 to 160 KVA |
| 169 | (e) Copper cable suitable for DG set 20 to 30 KVA |
| 170 | S & F in replacement battery terminal brass heavy duty complete etc all as specified and directed. |
| 171 | Supply & fixing in replacement of self starter motor suitable for 40 KVA to 62.5 KVA DG set 12 Volt DC of same capacity / model / make / type and connection up of make as approved. |
| 172 | Supply & fixing in replacement of self starter motor suitable for 20 KVA to 30 KVA DG set 12 Volt DC of same capacity / model / make / type and connection up of make as approved. |
| 173 | Supply & Fixing in repair neon Indicator lamp for 230 volt, 50 Hz for indication to incoming and out going supply complete all as specified & directed. |
| 174 | Supply & fixing in replacement of MCCB triple pole 200 Amps 36 KA, 415 volts, adjustable type, complete etc all as specified & directed.. |
| 175 | Supply & fixing in replacement of MCCB triple pole 400 Amps 50 KA, 415 volts, adjustable type, complete etc all as specified & directed.. |
| 176 | S&F in repair MCCB triple pole, 160 Amps, ultimate breaking cap 25 KA complete with motor break protection etc all as specified and directed. . |
| 177 | S&F in repair MCCB four pole, 125 Amps, ultimate breaking cap 16 KA complete with motor break protection etc all as specified and directed. . |
| 178 | S&F in repair MCCB four pole, 63 Amps, ultimate breaking cap 16 KA complete with motor break protection etc all as specified and directed. . |
| 179 | S&F in repair MCCB four pole, 400 Amps, ultimate breaking cap 50 KA complete with motor break protection etc all as specified and directed. . |
| 180 | BLANK |
| 181 | S & F in replacement over load relay 25 A, 24 Volt and 250 volt and 250 ohms complete etc all as specified and directed. |
| 182 | S & F in replacement digital amp meter size 96 x 96 mm to display 4 digit reading for DG set complete etc all as specified and directed. |
| 183 | S & F in replacement digital volt meter size 96 x 96 mm to display 4 digit reading for DG set complete etc all as specified and directed. |
| 184 | S & F in repair / replacement of winding exciter assembly for DG Set of any capacity / Make all as manufacturer design including connection and testing complete etc all as specified and directed. |
| 185 | S & F in repair diesel fuel flexible pipe for DG Set of any capacity / Make complete etc all as specified and directed. |
| 186 | S&F in replacement of oil pressure pipe for DG Set of any capacity complete etc all as specified and directed. |
| 187 | S &F in replacement changer over switch 4 pole, 160 Amp rating, 415 Volts, with steel enclosure and front handle type including connection lugs and testing complete etc all as specified and directed. |
| 188 | S & F in replacement changer over switch 4 pole, 100 Amp rating, 415 Volts, with steel enclosure and front handle type including connection with lugs and testing complete etc all as specified and directed. . |
| 189 | S & F in replacement Manual changer over switch 4 pole, 200 Amp rating, 415 Volts, with steel enclosure and Side handle operated type including connection with Lugs and testing complete etc all as specified and directed. . |
| 190 | S & F in replacement Manual changer over switch 4 pole, 250 Amp rating, 415 Volts, with steel enclosure and Side handle operated type including connection with Lugs and testing complete etc all as specified and directed. . |
| 191 | S & F in replacement Manual changer over switch 4 pole, 1000 Amp rating, 415 Volts, with steel enclosure and Side handle operated type including connection with Lugs and testing complete with fixing the clamps and necessry nut bolts etc all as specified and directed. . |
| 192 | Supply, laying or fixing or passing through pipe commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:- |
| 193 | (a) 240 Sqmm 3.5 core |
| 194 | (b) 95 Sqmm 3.5 core |
| 195 | (c) 25 sqmm 4 core |
| 196 | (d) 16 sqmm 4 core |
| 197 | Replacement of old/UNSV Engine oil 20W 40, multi grade 2904C servo super for DG sets all type complete etc all as specified and directed. |
| 198 | Supply and filling coolant for radiator in suitable container capacity complete etc all as specified and directed. |
| 199 | Supply and filling distilled water in suitable container capacity complete etc all as specified and directed. |
| 200 | S & F in replacement of electric shock treatment chart coloured of size approximately 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete etc all as specified and directed. |
| 201 | S & F in replacement of machinery maintenance chart coloured of size approximately 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete etc all as specified and directed. |
| 202 | Repairing of electrical ON LOAD AMF panel of DG set of Capacity up to 20/30 KVA with repairing and replacement of minor parts of contractor, coil, timmer or other parts to smooth fuctioning of panel etc all as required and directed at site |
| 203 | Repairing of electrical ON LOAD AMF panel of DG set of Capacity up to 82.5/ 125/160 KVA with repairing and replacement of minor parts of contractor, coil, timmer or other parts to smooth fuctioning of panel etc all as required and directed at site |
| 204 | Repairing of electrical ON LOAD AMF panel of DG set of Capacity 320 KVA with repairing and replacement of minor parts of contractor, coil, timmer or other parts to smooth fuctioning of panel etc all as required and directed at site |
| 205 | Dismantling / taking down of unserviceable turbo charger from following DG sets and transportation to authorised workshop of respective make / brand for repair / maintenance / balancing including replacement of required parts and make the same serviceable / functional complete etc all as specified & directed.(a) 40 KVA to 62.5 KVA Capacity |
| 206 | Supply & Fixing in repair shut down valve assembly complete of following DG sets. |
| 207 | (a) 20 KVA to 62.5 KVA capacity |
| 208 | (b) 320 KVA to 600 KVA capacity |
| 209 | Blank |
| 210 | Supply & Fixing in replacement of coupling hub of alternator of existing size and make of capacity 82.5/125 KVA DG set complete etc all as specified & directed. |
| 211 | Supply & Fixing in replacement of coupling hub of alternator of existing size and make of capacity 20/30 KVA DG set complete etc all as specified & directed. |
| 212 | Supply & Fixing in repair of maintenance free starting battery 12 volts, 88 AH etc all as specified and directed MAKE : EXIDE/ AMARON / LUCAS |
| 213 | Supply & Fixing in repair of maintenance free starting battery 12 volts,150 AH etc all as specified and directed MAKE : EXIDE/ AMARON / LUCAS |
| 214 | Supply & Fixing in repair of maintenance free starting battery 12 volts,180 AH etc all as specified and directed MAKE : EXIDE/ AMARON / LUCAS |
| 215 | Repair / maintenance of battery charger of existing capacity 12 to 24 volts DC including replacement of unserviceable parts such as diodes, rotory switches, transformers etc of the same make & model complete etc all as directed. |
| 216 | Supply & Fixing in repair of hose pipe set complete with clamps of following DG sets:- |
| 217 | (a) 40 KVA capacity |
| 218 | (b) 62.5 KVA capacity |
| 219 | (c) 82.5 KVA capacity |
| 220 | (d) 125/160 KVA capacity |
| 221 | (e) 320 KVA capacity |
| 222 | (f) 600 KVA capacity |
| 223 | (g) 1010 KVA capacity |
| 224 | (h) 20/30 KVA capacity |
| 225 | Supply & fixing in repair Automatic voltage Regulator suitable for 1000 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 226 | Supply & fixing in repair Automatic voltage Regulator suitable for 600 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 227 | Supply & fixing in repair Automatic voltage Regulator suitable for 320 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 228 | Supply & fixing in repair Automatic voltage Regulator suitable for 125/160 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 229 | Supply & fixing in repair Automatic voltage Regulator suitable for 82.5/62.5 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 230 | Supply & fixing in repair Automatic voltage Regulator suitable for 40 KVA & 62.5 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 231 | Supply & fixing in repair self starter, opening and repair to commutator replacement of carbon brush rewinding of stator coil and fixing self starter for 320 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 232 | Supply & fixing in repair self starter, opening and repair to commutator replacement of carbon brush rewinding of stator coil and fixing self starter for 600 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 233 | Supply & fixing in repair self starter, opening and repair to commutator replacement of carbon brush rewinding of stator coil and fixing self starter for 1010 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 234 | Supply & fixing in repair self starter, opening and repair to commutator replacement of carbon brush rewinding of stator coil and fixing self starter for 20 / 30 / 40 / 62.5 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 235 | Supply & fixing in repair self starter, opening and repair to commutator replacement of carbon brush rewinding of stator coil and fixing self starter for 82.5 / 125/160 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 236 | Supply & fixing in repair thermostat assembly for 600/1010 KVA DG Sets complete all as specified & directed by Engr-in-Charge |
| 237 | Supply & fixing in repair thermostat assembly for 320/125/82.5/62.5 KVA DG Sets complete all as specified & directed by Engr-in-Charge |
| 238 | Blank |
| 239 | Supply & fixing in repair super by pass filter for 600 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 240 | Supply & fixing in repair super by pass filter for 320 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 241 | Supply & fixing in repair super by pass filter for 125 to 250 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 242 | Taking out old asbestos rope from exhaust silencer system, cleaning silencer pipe exhaust system wrapping up new asbestos rope on exhaust silencer system applying plaster of paris on complete exhaust system upto 125 KVA DG Set complete etc all as specified & directed by Engr-in-Charge |
| 243 | Repairing of radiator assembly for cleaning all chocked tubes of water cooler radiator assembly by applying suitable chemical for cleaning of chocked tubes & re-assembling after cleaning or brazing of tubes if required for 320/600/1010 KVA capacity complete etc all as specified & directed by Engr-in-Charge |
| 244 | S & F in repair of digital display panel board of AMF PANEL with complete connecting accessories for Capacity 62.5 to 160 KVA Dg set all as specified and directed. |
| 245 | S & F in repair of power Contactor ML5/6 of L&T or equivalent stemford for Incoming/outgoing of AMF panel with complete accessories for capacity 125 to 320 KVA DG set of existing size complete and all as specified and directed. |
| 246 | Replacement of following unserviceable parts / items from the engine / alternator of diesel engine driven generating set of 1010/600/320 KVA capacity, 4-cyllinder of following item all as specified & directed.Note :Items required to be paid under supply only |
| 247 | (a) Oil filter element complete (MICO, Bosch or equivalent) 1010 KVA DG Set |
| 248 | (b) Oil filter element complete (MICO, Bosch or equivalent) 600/320 KVA DG Set |
| 249 | (c) Diesel filter element complete (MICO, Bosch or equivalent) 1010 KVA DG Se |
| 250 | (d) Diesel filter element complete (MICO, Bosch or equivalent) 600/320 KVA DG Set DG Set |
| 251 | (e) Diesel filter element complete (MICO, Bosch or equivalent) 1010 KVA DG Se |
| 252 | (f) Diesel filter element complete (MICO, Bosch or equivalent) 600/320 KVA DG Set DG Set |
| 253 | Blank |
| 254 | Opening the Cam shaft with connected nut bolts and remetaling and grinding and necessary lathe work for smooth functioning of any capacity of DG set, complete all as required and directed at site |
| 255 | Taking out the crank shaft assembly from DG set shifting to Workshop and return back and remetaling and necessary lathe work for any capacity all as required and directed |
| 256 | Opening the shadow less light ceiling mounted /movable with repair and replacement of lamps 12 volts-4 nos of suitable existing capacity and fixing and repair to minor part if required all as required and directed at site |
| 257 | S & F in replacement the insulating rubber mat 2x1 mtr, 19 mm thick, suitable for electrical supply laid at various installations complete etc all as required and directed at site |
| 258 | Opening the water assembly from DG set and taking out and repair to water pump with replacement of water seal, other related part and making good the water assembly complete of any capacity with fixing etc all as required and directed at site |
| 259 | Supply and fixing in replacement of PVC insulated, copper conductor 1100 volts cable of size 16sqmm, single core, unarmoured with suitable size copper lugs complete all as specifed and directed. |
| 260 | M&L for excavation in trenches for laying of under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in hard/dense soil complete all as specified and directed by Engr–in–charge. |
| 261 | S & F in repair door hinges (Right/Left handle) of suitable size for existing DG Set of any capacity complete all as specified and directed. |
| 262 | S & F in Replacement of Line Voltage Monitors (LVMS) of existing make of DG set of 100 KVA to 250 KVA capacity listed parameters including testing, complete all as specified and directed by Engr-in-Charge. |
| 263 | S & F in Replacement of Line Voltage Monitors (LVMS) of existing make of DG set capacity up to100 KVA capacity listed parameters including testing, complete all as specified and directed by Engr-in-Charge. |
| 264 | Overhauling of Turbo Charger Assembly duly disconnecting the mechanical and electrical connections of DG sets capacity upto 1010 KVA, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the same after repair to its original position and reconnecting the same including testing, complete all as specified and directed by Engr-in-Charge. |
| 265 | Earthing complete with GI earth plate electrode 60cm x 60cm x 3mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Aluminium earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion, complete all as specified and directed by Engr-in-Charge. Note:- Item of earthing includes cost of 7.5m long aluminium strip of 32 x 6mm size and protection pipe of 40 mm bore GI medium. |
| 266 | S & F in Replacement of controller display suitable to DG set controls/commands of 10 KVA to 62.5 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified |
| 267 | S & F in Replacement of controller display suitable to DG set controls/commands of 100 KVA to 250 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified |
| 268 | S & F in Replacement of controller display suitable to DG set controls/commands of following capacity with all listed parameters as per OEM recommendation including testing, complete all as specified |
| 269 | (a) 320 KVA capacity |
| 270 | (b) 600 KVA capacity |
| 271 | (c) 1010 KVA capacity |
| 272 | Blank |
| 273 | S & F in Replacement of Actuator suitable to DG set controls/commands of 62.5 KVA to 250 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 274 | S & F in Replacement of Actuator suitable to DG set controls/commands of 320 KVA to 600 KVA capacity with all listed parameters as per OEM recommendation including testing, complete all as specified and directed by Engr-in-Charge. |
| 275 | Supply and fixing in replacement of Governor Card complete all as specified and directed by Engr-in-Charge |
| 276 | Supply and mounting AVM (anti vibration) pads for Engine, radiator and alternator of DG set of any capacity including labour charges for proper mounting and all necessary misc accessories complete all as specified and directed by Engr-in-Charge |
| 277 | Supply and fix fuel tank lock and key suitable for existing DG set including removing old un serviceable one, complete all as specified and directed by Engr-in-Charge. |
| 278 | Supply and fix Door lock and key with door rod assy in side the door suitable for existing DG set including removing old un serviceable one, complete all as specified and directed by Engr-in-Charge. |
| 279 | S & F in replacemnt of voltage monitoring relay for existing DG set AMF panel of capacity up to 250 KVA including removing old un seviceable one, complete all as specified and directed by Engr-in-Charge. |
| 280 | S & F in replacement of voltage monitoring relay for existing DG set AMF panel of capacity 320 to 1010 KVA including removing old un serviceable one, complete all as specified and directed by Engr-in-Charge. |
| 281 | Taking down the U/S primary diesel feeder pump assy from DG set Supply, install, test & commissioning of primary diesel feeder pump assy inclusive of all spare and parts system for following DG set, complete all as specified and directed by Engr-in-Charge.Note :- Calibration shall be performed before erection of pump.(a) 10 KVA to 160 KVA |
| 282 | Taking down the U/S primary diesel feeder pump assy from DG set Supply, install, test & commissioning of primary diesel feeder pump assy inclusive of all spare and parts system for following DG set, complete all as specified and directed by Engr-in-Charge.Note :- Calibration shall be performed before erection of pump.(a) 250 KVA to 1010 KVA |
| 283 | S & F in repair Shutdown coil suitable for DG Set up to 600 KVA capacity as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 284 | S & F in repair Conversion Kit for DG Set any capacity as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 285 | S & F in repair Magnetic Pickup suitable for DG Set up to 125 to 600 KVA capacity as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 286 | Blank |
| 287 | S & F in repair Control Card DG Set up to 320 KVA capacity as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 288 | S & F in repair Solonoid coil suitable for DG Set 250 to 320 KVA capacity as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 289 | S & F in repair Solonoid coil suitable for DG Set upto 160 KVA capacity as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 290 | M & L Taking down water pump assembly of DG sets upto125 KVA capacity from its existing position, opening into parts, overhauling the same at workshop with replacement of water pump repair kit, ball bearing (1No) (Make SKF/NBC), gasket seal, oil seal and re-assembling and re-fixing on the base including to and fro conveyance charge from site to workshop and back, complete all as specified and directed by Engr-in-Charge. |
| 291 | Description all as per item No 14.00 here-in-before but water pump assembly of DG sets 250 to 320 KVA capacity, complete all as specified and directed by Engr-in-Charge. |
| 292 | S & F in replacement Residential type silencer suitable for 250 to 320 KVA capacity DG Set as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 293 | S & F in replacement Water temperature gauge as per existing type and make, complete all as specified and directed by Engr-in-Charge. |
| 294 | S & F in replacement Oil temperature gauge as per existing type and make, complete all as specified and directed by Engr-in-Charge. |
| 295 | S & F in replacement Exhaust bellow as per existing type and make, complete all as specified and directed by Engr-in-Charge. |
| 296 | S & F in replacement Radiator cap as per existing type and make, complete all as specified and directed by Engr-in-Charge. |
| 297 | S & F in replacement MPU Sensor suitable for DG Set up to 320 KVA capacity as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 298 | S & F in replacement CT 1000 Sensor suitable for DG Set any capacity as per existing type and model, complete all as specified and directed by Engr-in-Charge. |
| 299 | S&F in repair cam flower roller of capacity 320/600/1010 KVA DG set |
| 300 | S&F in repair push rod valve/injector of capacity 320/600/1010 KVA DG set |
| 301 | Excavation in trenches for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr–in–charge. |
| 302 | M&L for Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. |
| 303 | Supply and laying Precast concrete cable cover (ISI marked ) class HV in replacement, Type 1 with flat size 300mm x 180mm x 40mm all as specifed & directed by Engineer in charge. |
| 304 | Removing surplus excavated material to a distance not exceeding 5 0meter above the starting point complete all as specified and directed by Engr in charge. |
| 305 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr in charge. |
| 306 | Supply, laying, testing and commissioning of cable end termination joint in replacement indoor type cold shrinkable type suitable for stranded aluminium conductor 3 core, 11 KV, earthed, XLPE 50 -95 Sq mm cross sectional area complete all as specified and directed by Engr in charge |
| 307 | Supply, laying, testing and commissioning of cable end termination joint in replacement outdoor type cold shrinkable type suitable for stranded aluminium conductor 3 core, 11 KV, earthed, XLPE 50-95 Sq mm cross sectional area complete all as specified and directed by Engr in charge |
| 308 | Supply, laying, testing and commissioning of cable end termination joint in replacement indoor type cold shrinkable type suitable for stranded aluminium conductor 3 core, 11 KV, earthed, XLPE 120 -185 Sq mm cross sectional area complete all as specified and directed by Engr in charge |
| 309 | Supply, laying, testing and commissioning of cable end termination joint in replacement outdoor type cold shrinkable type suitable for stranded aluminium conductor 3 core, 11 KV, earthed, XLPE 120 -185 Sq mm cross sectional area complete all as specified and directed by Engr in charge |
| 310 | Supply, laying, testing and commissioning of Cable jointing kit in replacement for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr in charge |
| 311 | Supply, laying, testing and commissioning of Cable jointing kit in replacement for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr in charge. |
| 312 | M&L in repair earthing complete with copper earth plate electrode 60 cm x60 cm x 3.15 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including copper strip 20 X 3 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991)(a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 313 | Supply & laying (in replacement) galvanized steel tubing \\"light grade\\" with GI fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & directed by EIC for the following size:- |
| 314 | (a) 50mm bore |
| 315 | (b) 80mm bore |
| 316 | Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed. |
| 317 | Supply, laying, testing and commissioning of new XLPE insulated screened PVCbedded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11 KV (E) grade cross sectional area 120 sqmm 3 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 318 | Supply, laying, testing and commissioning of new XLPE insulated screened PVCbedded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11 KV (E) grade cross sectional area 95 sqmm 3 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 319 | Supply, laying, testing and commissioning of new XLPE insulated screened PVCbedded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11 KV (E) grade cross sectional area 185 sqmm 3 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 320 | Supply, laying, testing and commissioning of new XLPE insulated screened PVCbedded galvanised steel strip or wire armoured electric power cable with aluminium conductor 1100 V grade cross sectional area 16 sqmm 4 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 321 | Supply, laying, testing and commissioning of new XLPE insulated screened PVCbedded galvanised steel strip or wire armoured electric power cable with aluminium conductor 1100 V grade cross sectional area 35 sqmm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 322 | Supply, laying, testing and commissioning of new XLPE insulated screened PVCbedded galvanised steel strip or wire armoured electric power cable with aluminium conductor 1100 V grade cross sectional area 50 sqmm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 323 | Supply, laying, testing and commissioning of new XLPE insulated screened PVCbedded galvanised steel strip or wire armoured electric power cable with aluminium conductor 1100 V grade cross sectional area 120 sqmm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge. |
| 324 | Taking down old UNSV cable any size any type |
| 325 | Repairs/overhauling to 11KV/33 KV HT control Panels complete in and including the following repair works :- (a) Taking out 11KV High Tension VCB of 300 Amps to 800 Amps rating trolley from High Tension control Panel after switching off electric supply.Checking of mechanical system for proper functioning of upward/downward movement of High Tension Vacume Circuit Breakers trolley including opening the VCB & checking the quality of vacume bottles/links , & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB including connection to HT panel complete. (b). Taking out Digital Micom 122 relay set from high tension, 11KV, VCB control panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibration the relay by giving the primary and secondry injection and checking the tripping system by relay testing kit for over current and earth fault & proper plug setting as per reqd load & time delay and fixing the relay set in High Tension control panels complete all as specified and directed by EIC. (b) Spare parts to be replaced shall be measured & paid separately under the relevent items as supply only. |
| 326 | Supply and fixing in replacement shunt trip coil assembly suitable for High Tension ,VCB control panels, operating on 30/110 volt system and testing complete all as specified and directed by EIC. (Make Crompton/GEC/Areva) |
| 327 | Supply and fixing in replacement closing coil operated on 110 / 30 volt AC/DCsystem |
| 328 | Supply and fixing in replacement under voltage coil assembly suitable for HT VCB operated on 110/30 volt system and testing complete all as specified and directed by EIC. |
| 329 | Supply and fixing in replacement charging motor for high tension, 11 KV, VCB panels, 400 Amps, operated on 230 volts AC or 30 Volts DC as per sample complete all as specified and directed by EIC. |
| 330 | Taking out the old U/S indoor type VCB/OCB incomming/outgoing/bus coupler 400/800 Amps capacity from main after dissconnecting the electric connection and making the arrrangements to feed the supply with to other available feeder taking out the VCB /OCB and Opening the Vaccum Circuit breaker 400/800 amps capacity and dismentaling ,repair, overhauling the VCB with making the required lathe works if required and reassembling its on original position with making alignment for smooth functioning the VCB complete with replacement of following items all as required and directed at site |
| 331 | (a) Trip shaft as per sample - 1 no |
| 332 | (b) Link shaft |
| 333 | (c) Closing spring lever |
| 334 | (d) Main shaft |
| 335 | (e) Roller |
| 336 | (f) Bearing |
| 337 | (g) Cam |
| 338 | M&L in replacement for Vaccum interrupter 11 KV as per IS 13118-1991/IEC 56-1987 of 400 amps rating and fixing testing all as required and directed at site |
| 339 | Taking out the upper spout from existing panel and replacement of spout HT 11 KV VCB as per sample and fixing on panel all as required at site |
| 340 | Taking down and replacement of the Male contact made of tinned copper VCB panel 11 KV made of brass as per sample and fixing testing all as required and directed at site |
| 341 | Supply and spreading the stone aggregate of 40 mm size spreading in the substation/ as where directed at site |
| 342 | S&F Resin/Epoxy casted air cooled high tension current transformer of dual ratio of 150-50/5 Amps, 10 VA burden out put, accuracy class - 0.5, suitable for rated voltage system of 11 KV conforming to IS 2705/IEC 60044-1for metering/protection of breakers complete all as specified and directed. including taking down old. |
| 343 | Supply and fixing in replacement charging gear of 11 KV, VCB, 400-800 Amps complete all as specified and directed by EIC. |
| 344 | Supply and fixing in replacement, Over current and earth fault relay having auxilary voltage 24-110 volts, + 15% AC/DCcomplete all as specified and directed, Make :- Model No MC 61 of L&T or equivalent make as approved by the GE including taking down old |
| 345 | Supply and fixing in replacement panel lighting lamp with holder with on/off toggle switch |
| 346 | Supply and fixing in replacement bakelite HRC fuses in control/VCB panels |
| 347 | Repair/maintenance of 33 KV remote control panel/ capacitor panel by providing of 2.5 sqmm, twisted type copper wire, PVC insulated with bottle neck lugs and duly marking and bunching of wire to provide neat wiring of control panel, connector and bakelite fuses and making the tripping system and remote panel functional and testing after carrying out the repair work in and including disconnecting of existing unserviceable wire complete all as specified and directed by the Engr-in-charge at site. |
| 348 | Supply only breaker control switch suitable for 33 KV control panel and outdoor VCBs complete all as specified and directed including taking down old |
| 349 | Supply and fixing in replacement, power factor meter Model No ELF 3234 of emercon as per existing or as approved by the GE |
| 350 | Supply and fixing in replacement, Digital multifunctional meter Model No EM 6459, 0.5RS of Enercon as per existing or as approved by the GE |
| 351 | Supply and fixing in replacement, Push type on/off switch red or green for fixing in Remote control panel of 33/11 KV control panels complete as per existing or as approved by the GE |
| 352 | Supply and fixing in replacement selector switch for various type of control panels, technical specs as per existing selector switches installed on control panels. |
| 353 | Supply and fixing in replacement R,Y,B,W colour indicator lamps with holder for various control panels/ VCB panels complete all as specified and directed |
| 354 | Supply, install, testing and commissioning 33 KV oil immeresed current transformer for deterring and protection single phase outdoor type mounted on fabricated steel structure and fixing bolts, nuts, check nuts, washers etc complete all as directed for system rated nominal voltage 33 KV and system rated highest voltage 36 KV, 50Hz, CT ratio 50-25-5 amps, rated burden 50 VA accuracy class 0.5, and aaccuracy class, 5P, first filling of transformer insulation oil confirming to IS-336 and of dielectric strength 60 KV as IS-1866 and complete with all accessories in and including taking down of existing unserviceable current transformer complete all as specified and directed. |
| 355 | Supply & installation of 33 KV single phase outdoor oil cooled PT of ratio 11KV/rt3/110V/rt3, class 0.5-3 burden 50-50 VA including taking down of existing unserviceable current transformer complete all as specified and directed including taking down old |
| 356 | Supply, laying, fixing in cable duct, connecting and testing control cable, XLPE insulated, PVC inner sheath, galvanised wire/strip armoured, solid copper conductor, 1100 volts grade in and including taking down of old unserviceable control cables by opening of duct of any type and size and making good of follwing sizes including taking down old |
| 357 | (a) 2.5sqmm, 4 core |
| 358 | (b) 2.5sqmm, 8 core |
| 359 | M & L for duct cover Mild steel plates, chequered, of any thickness as required in replacement of RCC/PCC cover at site in Fe 410-W (Gde-E-250) quality-A with welding including lifting arrengment of duct cover complet in and incl taking out of existing rusted/unserviceable plates all as specified and directed by Engineer in charge. |
| 360 | M&L for dismantling of existing VCBs by disconnecting HT incoming and outgoing cables, disconnecting of earthings, and complete accories including providing transportation from one sub station to another substation and fixing, connecting, commissioning and testing the VCB at new location as directed by making all arrangements at new location and connecting the imcoming and outgoing cables as required and connecting the earthings etc and connecting the DC supply as well as AC supply for functioing of VCBs including overhauling of VCBs and making functional complete all as specified and directed by Engr-in-charge at site. Note : Spare parts required for making functional the VCBs if required shall be measured and paid seperately under relevant item of CA |
| 361 | Repairs/overhauling to 11KV RMU complete in and including the following repair works :- (a)Taking out top cover control Panel after switching off electric supply.Checking of mechanical system for proper functioning of upward/downward movement of moving contacts including opening the RMU & checking the quality of connections & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the RMU including connection to HT panel complete. (b). Above repair shall include checking proper functioning of Load Break Switch (LBS), VCB inside RMU and DO fuse link and make them serviceable if found unserviceable. |
| 362 | Supply and fixing in replacement shunt tripping coil of 11 KV RMU any number of ways as per existing one at site and testing on completion complete all as specified and as directed. |
| 363 | Supply and fixing , in replacement, load break switch mechanism assembly installed at 11 KV RMU any number of ways having two position spring assisted, Integrated line earthing switch making capacity and testing on completion complete all as specified and as directed. |
| 364 | Supply and fixing in repair/replacement CEF HV Back-up fuse link, striker 80N (Medium) as per IEC 60282-1, indoor type suitable of ABB make RMU of capacity IN = 40 Amps, Un-12 KV, I3 -105 Amps, I1=63 kA, the fuse link shall be strictly as per sample available at 33 KV main power house or as directed by Engr-in-charge at site complete all as specified and directed. |
| 365 | Supply and fixing repair/replacement CEF HV Back-up fuse link, striker 80N (Medium) as per IEC 60282-1, indoor type suitable of ABB make RMU of capacity IN = 80 Amps, Un-12 KV, I3 -105 Amps, I1=63 kA, the fuse link shall be strictly as per sample available at 33 KV main power house or as directed by Engr-in-charge at site complete all as specified and directed. |
| 366 | Supply and fixing, in replacement, motor cut off for spring charging motor of VCB trolly of Make & specifications as per existing one at site and testing on completion complete all as specified and as directed. |
| 367 | Supply and fixing, in replacement, spring charging gear assembly for VCB trolly of Make & specifications as per existing one at site complete all as specified and as directed. |
| 368 | S&F in replacement ammeter digital type, 96 mm x 96 mm, 0 - 200 Amps with built- in- selector switch complete for VCB 11 KV complete all as specified and directed |
| 369 | S&F in replacement voltmeter digital type, 96 mm x 96 mm, 0- 12 KV with built- in selector switch complete for VCB 11 KV & RMU's complete all as specified and directed |
| 370 | Supply and fixing of new LED indicator lamp with holder for various control panels/ VCB panels as per existing make/ as per manufacturer's instructions duly approved by Engr-in-Charge after taking out the old unserviceable switch and testing on completion complete all as directed. |
| 371 | Supply and fixing in replacement ZZ switch, trip circuit healthy of VCB and testing on completion complete all as specified and as directed. |
| 372 | Checking and testing of 33 KV CTs for VCBs by secondary injection current on primary side complete all as specified and directed. |
| 373 | Calibration of voltmeter 33 KV ( 04 Nos), 11 KV ( 4 Nos) and Ammeter 33 KV(03 Nos), 11 KV( 12 Nos) with present system load complete all as specified and directed. |
| 374 | Surface dressing and leveling by surface excavation and removal of debris to out side MD land where directed for the purpose of routine and periodical cleaning of inside area of 11 KV Sub Stations including cutting and removal/ uprouting of unwanted grass/ bushes, small trees near all around sub station. Note : Cleaning to be done by outsourcing staff or DEL. |
| 375 | S&F,in replacement, PVC insulation tap 25 mm width, 10 mtr long complete all as specified and as directed. |
| 376 | S&F,in replacement, HT insulation tap 25 mm width, 5 mtr long complete all as specified and as directed ( Make : 3M Birla or Equivalent Make as approved by GE). |
| 377 | Supply and Fixing in replacement copper fuse wire 100 Amps complete all as specified and as directed . |
| 378 | Supply and Fixing in replacement copper fuse wire 50 Amps complete all as specified and as directed . |
| 379 | Supply and Fixing in replacement copper fuse wire 5 Amps complete all as specified and as directed . |
| 380 | M&L for cable route indicator in replacement for HT cable with 11000 Volts embossed in MS sheet 5mm mounted in 50mm angle iron duly painted in red , with one coat of red oxide over two coats of sunthetic emanel paint with height 300mm above GL with PCC foundation all as per required and directed by Engg in Charge. Note: Rate quoted by contractor shall deemed to be included of excavation and earth work. |
| 381 | Supply and fixing in replacement MCCB 4 pole 160 Amps rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar complete all as specified and directed. |
| 382 | Supply and fixing in replacement MCCB 4 pole 200 Amps rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar complete all as specified and directed. |
| 383 | Supply and fixing in replacement MCCB 4 pole 250 Amps rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar complete all as specified and directed. |
| 384 | Taking down old UNSV MCCB any size any type |
| 385 | S&F in repair fuel pressure sensor for command bar to control fuel pressure and signal generator for ECM of 1010 KVA DG set complete. |
| 386 | S&F in repair ECM engine control module of 1010 KVA DG set complete. |
| 387 | S&F in repair transducer of any capacity complete |
| 388 | S&F in repair diode rectifier set complete. |
| 389 | Removing carbon deposit from the combustion chamber, piston crown and head assembly to restore the engine/efficiency by shutting down cooling, dismantling the cylinder head assembly and cleaning components by using specialized chemicals or mechanical scraping, checking for wear and tear and reassemble the same of following capacity of DG set complete |
| 390 | 20 to 40 KVA capacity |
| 391 | 62.5 to 250 KVA capacity |
| 392 | 320 KVA capacity |
| 393 | 600 KVA capacity |
| 394 | 1010 KVA capacity |
| 395 | Cutting the tar macadam roaf/hard standing for layinf cable and excavating not exc. 1.5m wide and 1.5m in depth and getting out all as directed incl filling back and finishing it with PCC complete matching with surroundings. |
| 396 | M&L for sub class B bricks as cable protection cover laid dry, flat, transversely along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed. |
| 397 | Schedule of credit amount of Rs. 2,28,111.56 to be deducted during AOC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender