Tender For For Running Contract Of Various Elcectrification Related Work In Full Deposite Head Under Edd-Chinor, Under Edc Shahjahanpur (Mvvnl)
Tender Overview
Project Description
Tender for For Running Contract Of Various Elcectrification Related Work In Full Deposite Head Under Edd-Chinor, Under Edc Shahjahanpur (Mvvnl)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Jul-2026 | ten 15 | Date | 13-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | The work of safe carriage of the following material from Byebagh store center to work site under the jurisdiction of EDD-First, Shajahanpur. Approx. distance upto 80 KM. Including safe loading and unloading. |
| 2 | PCC Ple 8.5 meter Long. |
| 3 | PCC Ple 9/11 meter Long. |
| 4 | STP 9/11/13 Meter Long. |
| 5 | Line material i.e, Cross arm/ Conductor / Pininsulater / stay/earthing rod / Disc Fitting / Disc Insulators / 11 kv XLPE Cable etc. |
| 6 | 11/0.4 KV 3 Phase 16/ 25 kva T/F |
| 7 | 11/0.4 KV 3 Phase 63 kva T/F |
| 8 | 11/0.4 KV 3 Phase 100 kva T/F |
| 9 | 11/0.4 KV 3 Phase 250/400 kva T/F |
| 10 | 11 kv CT PT Unit. |
| 11 | 11/33 KV VCB incoming/outgoing |
| 12 | 11 /33 KV Bus Coupler |
| 13 | 11 kv Pilfer Proof Metering Cubical |
| 14 | Erection of new PCC Single/Double Pole in H.T/L.T Line Including fitting of all accessories as per RESSPO Norms. |
| 15 | PCC Ple 8.5/ 9meter Long single |
| 16 | PCC Ple 8.5/ 9 meter Long double pole |
| 17 | PCC Ple 11 meter Long single pole |
| 18 | PCC Ple 11 meter Long double pole |
| 19 | ST Pole 9/11/13 Meter Long Single Pole. |
| 20 | ST Pole 9/11 Meter Long Double Pole. |
| 21 | Grouting with 1:4:8 mixture In Size(450x450x1500mm) Including cost of cement/BB & sand required as per RESSPO Norms |
| 22 | PCC Ple 8.5/ 9meter Long single |
| 23 | PCC Ple 8.5/ 9 meter Long double pole |
| 24 | PCC Ple 11 meter Long single pole |
| 25 | PCC Ple 11 meter Long double pole |
| 26 | ST Pole 9/11/13 Meter Long Single Pole. |
| 27 | ST Pole 9/11 Meter Long Double Pole. |
| 28 | The work of Driving the earthing electrode and making connections with 6 S.W.G GI Wire as per RESSPO Norms. |
| 29 | Laying stringing & sagging of Following Conductor Complete in all respect |
| 30 | ACSR Weasal Conductor |
| 31 | ACSR rabit/Dog |
| 32 | 3 Phase arial Bunched Conductor |
| 33 | 1 Phase Arial Bunched Conductor |
| 34 | Mounting of CT PT unit on double Pole. |
| 35 | UNDER GROUND LAYING OF FOLLOWING CABLE IN SINGLE CIRCUIT ON RIVER SAND TO DOUBLE POLE SITUATED AT BOTH SIDES OF ROAD COMPLETE IN ALL RESPECT. MINIMUM DEPTH SHOULD BE 0.50 METER AND CABLE FILLING OF 04 NOS. CABLE JOININGKITES. |
| 36 | 11 KV XLPE Cable Size 3x70 SQMM |
| 37 | 11 KV XLPE Cable Size 3x120 SQMM |
| 38 | 11 KV XLPE Cable Size 3x185 SQMM |
| 39 | 33 KV XLPE Cable Size 3x300 SQMM |
| 40 | Construction of Plinth |
| 41 | Fencing of Plinth |
| 42 | ERECTION AND GROUTING OF STAY SET GROUTING MATERIAL PROVIDING BY THE CONTRCTOR |
| 43 | INSTALLATION OF X ARM |
| 44 | Installation of 11 kv Pilfer Proof metering Cubicle in metering room complete in all respect. |
| 45 | Mounting of Following Capacity Transformers as per norms complete in all respect. |
| 46 | 16/ 25 KVA T/F |
| 47 | 63 KVA T/F |
| 48 | 100 KVA T/F |
| 49 | 250/400 KVA T/F |
| 50 | Fixing of Distribution Box complete in all respect |
| 51 | Guarding at road crossing complete in all respect |
| 52 | Dismantling of Lines |
| 53 | Safe back carriage of scrap (if any) from work site to bye bagh stroe shahjahanpur approx distance upto 80 KM including safe loading and unloading. |
| 54 | Fabrication works |
| 55 | Dismantling of 16/25/63/100 kva/ kva transformer |
| 56 | Dismantling of 250 kva/400kva/630 kva transformer with back carraige site to store |
| 57 | removing of connection |
| 58 | Fixing and Providing of x-ARM Clamp. |
| 59 | Fixing and Providing of Stay Clamp. |
| 60 | Fixing and Providing of top Channel Clamp. |
| 61 | Fixing and Providing of TEE OFF CHANNEL Clamp. |
| 62 | Fixing and Providing of LT CLAMP FOR PCC/ STP . |
| 63 | Fixing and Providing of DED AND CLAMP FOR PCC/STP. |
| 64 | Fixing and Providing of SUSPENSION CLAMP FOR PCC/STP. |
| 65 | Fixing and Providing of ALLU. LUGS 70 SQ MM FOR PCC/STP. |
| 66 | Fixing and Providing of ALLU. LUGS 95 SQ MM FOR PCC/STP. |
| 67 | Fixing and Providing of ALLU. LUGS 120 SQ MM FOR PCC/STP. |
| 68 | Fixing and Providing of ALLU. LUGS 185 SQ MMFOR PCC/STP. |
| 69 | Fixing and Providing of ALLU. LUGS 240 SQ MM FOR PCC/STP. |
| 70 | Fixing Of Lt xlpe led difrent size |
| 71 | Fixing and Providing of tailis unit 400 amp WITH CLAMP AND NUT BOLT AND INSTALATION |
| 72 | Fixing and Providing of tailis unit 600 amp WITH CLAMP AND NUT BOLT AND INSTALATION |
| 73 | Fixing and Providing of HT FUSE SET ON DOUBLE POLE STP/PCC WITH CLMP |
| 74 | Fixing and Providing of gi pipe 4 ' dia |
| 75 | Fixing and Providing of gi pipe 6' dia |
| 76 | Fixing and Providing of GI HOOK FOR PCC/STP. |
| 77 | FILLING OF . CABLE JOINING KITES. |
| 78 | Fixing and Providing of NUT AND BOLT OFF Size. |
| 79 | DANGER PLATE |
| 80 | Fixing 11/33 KV VCB outgoing / incoming in all respect as per RESPO norm. |
| 81 | Dismantling of 11 KV VCB outgoing / incoming store loading and unloading both side. |
| 82 | fixing of busbar |
| 83 | pipe erthing of vcb and transformer etc |
| 84 | PG CLAMP FOR ACSR/DOG CONDUCTOR Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender