Tender For Repair/ Maintenance /Replacement Of Electric Appliances And Water Supply Pipe Line Etc At Zangli, Drugmulla, Chakkigam Under The Aor Of Ge 874 Ews.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Jul 2026
11 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kupwara → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair/ Maintenance /Replacement Of Electric Appliances And Water Supply Pipe Line Etc At Zangli, Drugmulla, Chakkigam Under The Aor Of Ge 874 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | M & L for point wiring with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, drawn through PVC casing caping/PVC conduit 20mm dia including accessories and provision of PVC boxes for mounting switches, switch socket, fan regulator, provision of modular Teressa plate Irene stripes, No of modules as required on site or as directed including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) earth wire and connected to earth dolly for one light /one fan/one bell point controlled by one switch complete all as specified and directed. |
| 2 | All as per item No 1 here in before but for one socket outlet 5 pins 5 amps controlled by one switch on same board. |
| 3 | All as per item No 1 here in before but for one socket outlet 5 pins 5 amps controlled by one switch on independent board. |
| 4 | All as per item No 1 here in before but for one wiring with 2.5 sqmm copper wire (FRLSH) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board complete all as specified and directed. |
| 5 | S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed. |
| 6 | S&F socket outlet multi 5 pins 5 amp, complete all as specified and directed. |
| 7 | S & F switch socket combination 2 in 1, 5A flush type complete all as specified and directed. |
| 8 | S&F switch piano flush button single pole, one way 15amps complete all as specified and directed. |
| 9 | S&F socket outlet 2 in 1, 6 pins 15 amp, complete all as specified and directed. |
| 10 | S & F switch socket combination 3 pin 16A, flush type complete all as specified and directed. |
| 11 | S&F ceiling rose, PVC/poly carbonate, isolated body three terminal complete all as specified and directed. |
| 12 | S&F Modular switch 1way 6A, 1 module complete all as specified and directed. |
| 13 | S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed. |
| 14 | S&F Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 15 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed. |
| 16 | S&F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting including 7 watt LED Lamp complete all as specified and directed. |
| 17 | S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 4 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. |
| 18 | S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 8 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. |
| 19 | S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 12 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. |
| 20 | S&F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 amp complete all as specified and directed. |
| 21 | S&F in repair RCBOs double pole for earth leakage, overload & Short-Circuit protection 40 Amps, 100mA complete all as specified and directed. |
| 22 | MCB single pole & neutral 40 to 63 Amps 230 Volts 'C' series, 10 KA complete all as specified and directed. |
| 23 | S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' series, complete all as specified and directed. |
| 24 | Supply and fixing in replacement Exhaust fan AC single phase, 1200 rpm 230/240V of size 250mm sweep with louvre heavy duty complete all as specified and directed. |
| 25 | Supply and fix water heater storage type, electric capacity 25 ltr along with all accessories BEE 5 star rated, complete all specified and directed. |
| 26 | Supply and fix water heater storage type, electric capacity 10 ltr along with all accessories BEE 5 star rated, complete all specified and directed. |
| 27 | M & L for sub main wiring with two single core 6 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLSH ISI marked drawn into & including medium grade PVC conduit/ casing caping 25 mm dia with all fittings and accessories and one continuous run of 4 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surface including taking down old unserviceable submain wiring and making good disturbed surface complete all as specified and directed. |
| 28 | M & L for sub main wiring with two single core 4 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor (FRLSH) ISI marked drawn into & including medium grade PVC conduit/ casing caping 25 mm dia with all fittings and accessories and one continuous run of 2.5 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surface including taking down old unserviceable submain wiring and making good disturbed surface complete all as specified and directed. |
| 29 | S & F in replacement LED light fitting 1x9W/1X10Wbulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 30 | Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 31 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 32 | Supply and fixing of VILLA 1 W 5700 K Solar Gate/Pillar Light IP65 protection with built-in Solar panel, LED Light and Lithium battery with charge controller with driver and lamp complete all as specified and directed. |
| 33 | Supply and fixing of 7 Watt Outdoor type BRILLANTE ROUND WALL WASHER Crafted from Aluminium die Cast with Four-Directional Beam. Its integrated LED ensures long-lasting and energy-efficient with IP65 Protected complete all as specified and directed. |
| 34 | Supply and fixing in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 35 | Supply and fixing in replacement LED luminaire 600 mm x 600 mm 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 36 | Supply and fix rechargeable/inverter LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 37 | Supply and fix Rechargeable/inverter LED Lamp 9 Watt & complete all as specified and directed. |
| 38 | S&F bed side designer light 7 watts with LED inverter type, including all wiring and switches required, with terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 39 | Supply and fix in replacement Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED 20W B22 base with 1x20 watt LED lamp complete all specified and directed. |
| 40 | Supply and fix in replacement unique LED flood/focus light 70 W LED 6500 K with IP 65 protection complete all specified and directed. |
| 41 | Supply and fix in replacement focus light 12/15 W LED (as per sample) with IP 65 protection complete all specified and directed. |
| 42 | M&L rewinding of ceiling fan with super copper enamelled wire with suitable gauge, varnishing, oiling and greasing of any make of size 1200 /1400 mm sweep by dismantling its parts, capacitor by replacing petty items such as split pins, clamps, nuts & bolts, bearing & washer both end of down rod, cleaning of fan body and its blade by cleaning agent, assembling and connecting testing complete all as specified and directed. |
| 43 | M&L for rewinding of exhaust fan with super copper enamelled wire with suitable gauge, varnishing, oiling and greasing of any make of size 450 mm sweep by dismantling its parts, capacitor 4 Mfd by replacing petty items such as nuts & bolts, bearing & washers, cleaning of exhaust fan body and its blade by cleaning agent, assembling and connecting and testing complete all as specified and directed. |
| 44 | Supply and fixing ball bearing suitable for Ceiling and exhaust fan of any sweep and make complete all as specified and directed. |
| 45 | Supply and fixing gun metal bush suitable for any sweep fan of any complete all as specified and directed. |
| 46 | Supply and fixing of Capacitor 2.5/3/4 mfd complete all as specified and directed. |
| 47 | Supply and fix in replacement heating element of capacity of 1500 Watts (triangle type) for 25 Ltr capacity geysers complete all as specified and directed. |
| 48 | Supply and fix in replacement heating element of capacity of 2000 Watts for 25 Ltr geyser (triangle type). complete all as specified and directed. |
| 49 | Supply and fix of unserviceable heating element of capacity of 3000 watts for 225 Ltr geyser complete all as specified and directed. |
| 50 | S&F in repair/replacement of thermostat 7''/9\\" suitable for 25/50 ltrs capacity water geyser with automatic thermal cut out fixed in repair and including testing, complete all as specified and directed. |
| 51 | Supply and fixing in repair of copper Geyser Assembly with rubber packing for 25/50 ltrs capacity water geyser with automatic thermal cut out and including testing, complete all as specified and directed. |
| 52 | S & F and testing of compressor (Non-Inverter/Inverter) for split type air conditioner of capacity 1.5/2 ton and taking down of unserviceable compressor complete all as specified and directed. |
| 53 | S & F and testing of thermistor (temperature Sensor) for split type air conditioner of capacity 1.5/2 ton and taking down unserviceable blower complete all as specified and directed. |
| 54 | S & F and testing of PCB (Indoor/outdoor) for split type air conditioner of capacity 1.5/ 2 ton and taking down unserviceable PCB, complete all as specified and directed. |
| 55 | S & F and testing of Blower motor (Indoor fan motor /Outdoor fan Motor) for split type air conditioner of capacity 1.5/2 ton and taking down unserviceable blower complete all as specified and directed. |
| 56 | S & F and testing of Voltage Stabilizer 5 KVA for split type air conditioner of capacity 1.5/2 ton and taking down unserviceable Voltage stabilizer deposited to MES Store complete all as specified and directed. |
| 57 | S & F and testing of outdoor unit motor for split type air conditioner of capacity 2/ 1.5 ton and taking down unserviceable motor complete all as specified and directed. |
| 58 | S & F and testing of outer unit fan of split type air conditioner of capacity 1.5/2 ton and taking down of unserviceable fan complete all as specified and directed. |
| 59 | S & F and testing of 2 Way Valve Assembly of split type air conditioner of capacity 1.5/2 ton and taking down of unserviceable fan, complete all as specified and directed. |
| 60 | Supply and fixing of Capacitor 50 MFD for 1.5 / 2 ton AC complete all as specified and directed. |
| 61 | Supply and refilling of gas R-22/ R-410/R32/ R134a for split/ window/ central package type Air conditioners and Refrigerators including checking and fixing leakage complete all as specified and directed. |
| 62 | S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminium stranded conductor served with PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension ire one twin core flat cable of circular of size 10 sqmm complete all as specified and directed. |
| 63 | S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminium stranded conductor served with PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension ire one twin core flat cable of circular of size 16 sqmm complete all as specified and directed. |
| 64 | M&L earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed. |
| 65 | Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for laying of pipes as in hard soil and getting out, complete all as specified and directed. |
| 66 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed. |
| 67 | Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed. |
| 68 | Supply and laying Cast iron pipes with spigot and sockets ends centrifugally, Class LA in 150 mm size laid in trenches & including taking down old one complete all as specified and directed. |
| 69 | Supply and laying Cast iron pipes with spigot and sockets ends centrifugally, Class LA in 100 mm size laid in trenches & including taking down old one complete all as specified. |
| 70 | Supply and laying Cast iron pipes with spigot and sockets ends centrifugally, Class LA in 80 mm size laid in trenches & including taking down old one complete all as specified and directed. |
| 71 | Supply & fixing bends (any type radius and angle tapers any type (straight, bend, increasing decreasing or double sockets etc) Tee pieces single branch 'Y' Junction, double branch, cross (all sockets or sockets and spigot) collars caps and plugs upto 150mm bore complete all as specified and directed. |
| 72 | M&L for run lead joint for CI pipe spigot and socket pipes and fittings of 80 mm bore complete all as specified and directed. |
| 73 | M&L for run lead joint for CI pipe spigot and socket pipes and fittings of 100 mm bore complete all as specified and directed. |
| 74 | M&L for run lead joint for CI pipe spigot and socket pipes and fittings of 150 mm bore complete all as specified and directed. |
| 75 | S&F GI water tubing 15mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches including taking down old one complete all as specified and directed. |
| 76 | All as per description of srl item No.75 above but 20mm. |
| 77 | All as per description of srl item No-75 above but 25mm. |
| 78 | All as per description of srl item No-75 above but 40mm. |
| 79 | All as per description of srl item No-75 above but 50mm. |
| 80 | All as per description of srl item No-75 above but 80mm. |
| 81 | S&F gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of bore of 15mm complete all as specified and directed.. |
| 82 | All as per description of srl item No-81 above but 20mm. |
| 83 | All as per description of srl item No-81 above but 25mm. |
| 84 | All as per description of srl item No-81 above but 40mm. |
| 85 | All as per description of srl item No-81 above but 50mm. |
| 86 | Taking down old unserviceable old sluice valve and supply and fixing ball valve having SS ball with both CI end flanged, ISI marked, with nuts, bolts and washer and rubber gasket with stainless steel handle over PVC coating complete all as specified and directed for 80 mm bore pipe complete all as specified and directed. |
| 87 | Taking down old unserviceable old sluice valve and supply and fixing sluice valve cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation, packing rings, jointing materials nuts, bolts washer, gasket and packings material etc all as specified and directed for 100 mm dia complete all as specified and directed. |
| 88 | Taking down old unserviceable old sluice valve and supply and fixing sluice valve cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrangement such as rubber insulation, packing rings, jointing materials nuts, bolts washer, gasket and packings material etc all as specified and directed for 150 mm dia complete all as specified and directed. |
| 89 | Supply and fixing in replacement CI Non return valve of size 100mm bore without bypass arrangement swing type confirming to IS 5312-1 flanged end, pressure rating PN 1.6 complete all as specified and directed. |
| 90 | Supply and fixing in replacement CI Non return valve of size 80mm bore without bypass arrangement swing type confirming to IS 5312 flanged end pressure rating PN 1.6 complete all as specified and directed. |
| 91 | M&L for lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed and covering the mineral wool with POP and ‘SNAP ON’ pipe sections of tin sheet conforming to IS 9842 for 20 mm dia pipeline complete all as specified and directed. |
| 92 | M&L for lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed and covering the mineral wool with POP and ‘SNAP ON’ pipe sections of tin sheet conforming to IS 9842 for 25 mm dia pipeline complete all as specified and directed. |
| 93 | Supply and replacement of 10 Sqmm 3 Core submersible copper conductor flat type for submersible pump complete all as specified and directed. |
| 94 | Dewatering and taking out sludge from tank of size and capacity (10000 to 40000Gln), removing the same to a distance not exceeding 50m with & including, cleaning the sump by wire brushing including ,including brooming down complete including white washing internally complete all as specified and directed. |
| 95 | Supply & Fixing in replacement (after testing at site) fully automatic star delta starter for 40 HP/32 KW (over load relay range 22 Amps to 32 Amps) Centrifugal pump motor /submersible pump provide with protection degree IP 54, confirming to IS/IEC-60947-4-1, contractor size 32, Extended wide band coil, Starter type Air Break, FRLS internal Wiring complete all as specified and directed. |
| 96 | Supply & Fixing in replacement (after testing at site) fully automatic star delta starter for 20 HP/16 KW (over load relay range 15 Amps to 22 Amps) Centrifugal pump motor /submersible pump provide with protection degree IP 54, confirming to IS/IEC-60947-4-1, contractor size 25, Extended wide band coil, Starter type Air Break, FRLS internal wiring complete all as specified and directed. |
| 97 | Supply & fixing in replacement (after testing at site) fully automatic star delta starter for 15 HP/12 KW (over load relay range 12 Amps to 18 Amps) Centrifugal pump motor /submersible pump (as Per site requirement) provide with protection degree IP 54, confirming to IS/IEC-60947-4-1, contractor size 22, Extended wide band coil, Starter type Air Break, FRLS internal wiring complete all as specified and directed. |
| 98 | Material and labour for repair of centrifugal motor pump set 40 HP (Rewinding job will be measured separately), including removing the motor pump from the foundation, disconnecting from the motor and transporting to the work shop for repair including replacement of worn out impellers-01 set with bronze impellers, replacing bearing No 6312-02 Nos, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers and bringing back the pump to the pump house and coupling the pump with motor and fixing on foundation and testing complete all as specified and directed. |
| 99 | Material and labour for repair of centrifugal motor pump set 20/ 25 HP (Rewinding job will be measured separately), including removing the motor pump from the foundation, disconnecting from the motor and transporting to the work shop for repair including replacement of worn out impellers-01 set with bronze impellers, replacing bearing No 6307-02 Nos, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers and bringing back the pump to the pump house and coupling the pump with motor and fixing on foundation and testing complete all as specified and directed. |
| 100 | Material and labour for rewinding of 40HP centrifugal motor by uncoupling the motor from the pump, removing the motor from the foundation and transportation of the motor to the workshop, opening the motor , taking out burnt out winding, preparing the slot for winding and rewinding of motor with super enamelled copper winding wire of appropriate size and gauge as existing to make the same cap of motor, varnishing and heat drying including scrapping of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and testing complete all as specified and directed. |
| 101 | Material and labour for rewinding of 20/25HP centrifugal motor by uncoupling the motor from the pump, removing the motor from the foundation and transportation of the motor to the workshop, opening the motor, taking out burnt out winding, preparing the slot for winding and rewinding of motor with super enamelled copper winding wire of appropriate size and gauge as existing to make the same cap of motor, varnishing and heat drying including scrapping of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and testing complete all as specified and directed. |
| 102 | Material and labour for rewinding of 7.5 HP to 10 HP centrifugal motor by uncoupling the motor from the pump, removing the motor from the foundation and transportation of the motor to the workshop, opening the motor , taking out burnt out winding, preparing the slot for winding and rewinding of motor with super enamelled copper winding wire of appropriate size and gauge as existing to make the same cap of motor, varnishing and heat drying including scrapping of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and testing complete all as specified and directed . |
| 103 | Material and labour for taking out the submersible pump set and motor assembly of capacity 5 HP to 25 HP from the borewell, by taking out the column pipes with chain pulley block and tripod stand, complete using skilled and experienced labour and transporting the same to workshop for repair and replacement of worn impellers -01 set , replacement of worn out bushings and bearings and transport back repaired pump set back to site after repair and Lowering the same in the bore well after testing complete all as specified and directed. |
| 104 | Material and labour for rewinding of submersible motor 25 HP by taking out the burnt out winding from the starter with PVC insulated copper winding wire of same gauge and size as per existing, replacement of thrust bearing and bushes and testing complete all as specified and directed . |
| 105 | Material and labour for rewinding of submersible motor 7.5 HP by taking out the burnt out winding from the stator with PVC insulated copper winding wire of same gauge and size as per existing, replacement of thrust bearing and bushes and testing complete all as specified and directed . |
| 106 | M& L for pipe line leakage repairing work of any size or specification after disconnecting the near by joint and replacing the GI fitting, short pieces as required and refixing the same, complete all as specified and directed. Note: required fitting/short pieces will be paid and measured under relevant items as here in after |
| 107 | Supply and fix GI Union 50 mm dia complete all as specified and directed. |
| 108 | Supply and fix GI Union 15 mm dia complete all as specified and directed. |
| 109 | Supply and fix GI Union 20 mm dia complete all as specified and directed. |
| 110 | Supply and fix GI Union 25 mm dia complete all as specified and directed. |
| 111 | Supply and fix GI Union 40 mm dia complete all as specified and directed. |
| 112 | Supply and fix GI Union 80 mm dia complete all as specified and directed. |
| 113 | Supply and fix GI Union 100 mm dia complete all as specified and directed. |
| 114 | Supply and fix GI socket 15 mm dia complete all as specified and directed. |
| 115 | Supply and fix GI socket 20 mm dia complete all as specified and directed. |
| 116 | Supply and fix GI socket 25 mm dia complete all as specified and directed. |
| 117 | Supply and fix GI socket 40 mm dia complete all as specified and directed. |
| 118 | Supply and fix GI Nipple150mm long, 15 mm dia complete all as specified and directed. |
| 119 | Supply and fix GI Nipple150mm long, 20 mm dia complete all as specified and directed. |
| 120 | Supply and fix GI Nipple150mm long, 25 mm dia complete all as specified and directed. |
| 121 | Supply and fix GI Nipple150mm long, 40 mm dia complete all as specified and directed. |
| 122 | Supply and fix GI Tee equal 20mm bore ISI marked complete all as specified and directed. |
| 123 | Supply and fix GI Tee equal 25mm bore ISI marked complete all as specified and directed. |
| 124 | Supply and fix GI Tee equal 40mm bore ISI marked complete all as specified and directed. |
| 125 | Supply and fix GI Tee equal 50mm bore ISI marked complete all as specified and directed. |
| 126 | Supply and fix GI Elbow 20 mm bore ISI marked complete all as specified and directed. |
| 127 | Supply and fix GI Elbow 25 mm bore ISI marked complete all as specified and directed. |
| 128 | Supply and fix GI Elbow 40 mm bore ISI marked complete all as specified and directed. |
| 129 | Supply and fix GI Elbow 50 mm bore ISI marked complete all as specified and directed. |
| 130 | S&F in replacement gland packing of suitable size for 20/40/60 HP pump complete all as specified and directed. |
| 131 | S&F in replacement bearing of suitable size for 20/40/60 HP pump complete all as specified and directed. |
| 132 | S&F in replacement leather gasket suitable for 80/100 mm dia pipe complete all as specified and directed. |
| 133 | S&F in replacement CI flange for 80/100 mm dia pipe tape complete all as specified and directed. |
| 134 | S&F in replacement Nut & Bolts 20x50 mm, 20x75mm, 20x100mm complete all as specified and directed. |
| 135 | S&F in replacement Nut & Bolts 15x50 mm, 15x75mm, 15x100mm complete all as specified and directed. |
| 136 | Supply and fix calcium hypochlorite granules (65% to 70%) disinfectant for water treatment, more stable than Chlorine Gas and Stronger than bleaching powder and solidum Hypochlorite) Packing in 45 Kg in plastic Drums complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysJul 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender