Tender For Supply, Installation, Laying, Testing & Commissioning Including All Accessories Work Of 220Kv Double Circuit Single Core 1000 Sq. Mm Copper Xlpe Cable & 2 Nos. Monopole For Lilo Transmission Line At Talcher Fertilizers Limited Talcher, Odi
Tender Overview
Project Description
Tender for Supply, Installation, Laying, Testing & Commissioning Including All Accessories Work Of 220Kv Double Circuit Single Core 1000 Sq. Mm Copper Xlpe Cable & 2 Nos. Monopole For Lilo Transmission Line At Talcher Fertilizers Limited Talcher, Odisha.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-Jul-2026 | Amendment I | Technical Bid | 24-Jul-2026 |
| 2 | 17-Jul-2026 | AMENDMENTII | Date | 06-Aug-2026 |
| 3 | 07-Jul-2026 | Amendment I | Technical Bid | 06-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Electrical WorksSupply (Monopole Tower) |
| 2 | SUPPLY including design approval of Following tested Monopole (tubular) type Galvanized steel tangent / Angle monopole tower (pole shaft,Base plate,anchor bolt, cross arm,connection bolt, ladder, anti climbing device etc ) as per the Technical specification with special type cross arms for Double Circuit Cable Termination arrangement.MATERIAL SPECIFICATIONS: for Shaft & Base Plate• Pole Shaft ASTM A572-65 or Equivalent• Arm & Arm Bracket ASTM A572-65 or Equivalent• Base Plate ASTM A572-50 or Equivalent• Bolts and Nuts:Material for anchor bolts shall conform to grade 6.8 or 8.8 as per the requirement. Exposed portion of the Anchor bolts shall be galvanized in accordance with ASTM A 153.Material for headed bolts shall be of grade 6.8 or 8.8 and shall be galvanized in accordance with ASTM A 153. When inch size bolts are used, they shall conform to: ASTM A307, ASTM A325, ASTM A490 or ASTM A449 when bolt diameter exceeds 38.1 mm (1.5 in.) Threaded rod shall be of grade 6.8 or 8.8. When inch size threaded rods are used, they shall conform to ASTM A36, ASTM A354, ASTM A449, ASTM A588 or ASTM A687.Note: All tower shall be Suitable for 220 KV (HSV:245 KV) voltage class TENSION TYPE MONOPOLE TOWERS INCLUDING ALL ACCESSORIES |
| 3 | Erection (Monopole Tower) |
| 4 | ERECTION,TESTING & COMMISSIONING of Double Circuit Cable Termination type of Following type tested Monopole (tubular) type Galvanized steel tangent / Angle monopole tower (pole shaft,Base plate,anchor bolt, cross arm,connection bolt, ladder, anti climbing device etc ) as per the Technical specification with special type cross arms for Double Circuit Cable Termination arrangement.MATERIAL SPECIFICATIONS: for Shaft & Base Plate• Pole Shaft ASTM A572-65 or Equivalent• Arm & Arm Bracket ASTM A572-65 or Equivalent• Base Plate ASTM A572-50 or Equivalent• Bolts and Nuts:Material for anchor bolts shall conform to grade 6.8 or 8.8 as per the requirement. Exposed portion of the Anchor bolts shall be galvanized in accordance with ASTM A 153.Material for headed bolts shall be of grade 6.8 or 8.8 and shall be galvanized in accordance with ASTM A 153. When inch size bolts are used, they shall conform to: ASTM A307, ASTM A325, ASTM A490 or ASTM A449 when bolt diameter exceeds 38.1 mm (1.5 in.) Threaded rod shall be of grade 6.8 or 8.8. When inch size threaded rods are used, they shall conform to ASTM A36, ASTM A354, ASTM A449, ASTM A588 or ASTM A687.Note: All tower shall be Suitable for 220 KV (HSV:245 KV) voltage class TENSION TYPE MONOPOLE TOWERS INCLUDING ALL ACCESSORIES |
| 5 | SUPPLY(Cable with all accessories) |
| 6 | SUPPLY OF 220 KV GRADE Single CORE, 1000 SQ.MM.XLPE INSULATED COPPER CABLE AS PER TECHNICAL SPECIFICATION INCLUDING ONE SPARE CABLE AS PER TECHNICAL SPECIFICATION (Six run,One Spare for Each Circuit to be handed over to OPTCL). |
| 7 | SUPPLY OF 220 KV XLPE CABLE STRAIGHT THROUGH JOINT KIT/CROSS BONDING JOINT KIT IN COMPLETESUITABLE FOR 220 KV 1000 SQMM WITH LINK BOXES with and without SLV as per site requirements and technical specification.(6 Nos JOINT KIT To be Handed Over to OPTCL) |
| 8 | 220KV Cable Termination kit outdoor type for 220KV volatege level suitable for 1C X 1000 Sq. mm copper cable including accessorries and all consumables.(04 Nos to be Handed Over To OPTCL) |
| 9 | Metal oxide polymer housed surge arrrestor for 220 kV system. Station Class Medium Duty (SM) type In, Ur, Uc, Wth & Qrs as per technical specification/Latest IEC complete with insulating base and Surge monitor (AIS). - As per TS |
| 10 | 6.6KV, 300 Sq.MM Single core Bonding cable including connection/termination as required to make the system complete in all respect. |
| 11 | MISCELLANEUOS INSTALLATION MATERIALS FOR CABLE LAYING, JOINTING AND BONDING INCLUDING LINK BOXES, SHEATH VOLTAGE LIMITERS, EARTH CONTINUITY CABLE, EARTHING MATERIAL, CABLES ROUTE MARKERS,WARNING TAPES, TREFOIL CLAMPS (at 1 Mtr Apart) AND ALL OTHER MATERIALS ETC REQUIRED AS PER TECHANICALSPECIFICATIONS AND AS PER STATUTARY REQUIREMENTS |
| 12 | 48 Fibre Optic Approach Cable(DWSM) |
| 13 | Installation hardware set((HDPE Duct,HDPE couplingetc) for 48 Fibre FOAC. |
| 14 | Joint Box (Splice enclosure),48 Fibre |
| 15 | Earthing Material for 220 kV Cable, Joint box and at Termination End as per Technical Specification. |
| 16 | Insallation and Commisiong ( Cable with all accessories) |
| 17 | Laying of 220 kV grade, Single core, 1000sq.mm.XLPE insulated copper cable WITH FIXING OF CLAMPS AND FILLING OF THERMAL BACKFILL(cement,sand and fly ashas per specification) as per technical specification.This also includes transportation from the nearest store to the working site,storing safely at the site,pre erection and commissioning testing as per technical specification and any other additional requiremnts for completion of the work. |
| 18 | Erection OF 220 KV 1Cx1000 Sq Mm XLPE CABLE STRAIGHT THROUGH JOINT/Cross Bonding Joint KIT COMPLETE SUITABLE FOR 220 KV 1000 SQMM WITH LINK BOXES. This also includes construction of temporary water proof tent shed for Cable Jointing Bay, including arrangement of all the necessary tools and plants, including Air Conditioner, temporary power supply etc. at the jointing bay site not limiting to the above and any other requirements for completion of the work as per specification. |
| 19 | Erection of 220 KV 1Cx1000 Sq Mm XLPE Cable end termination(s) kits on Cable Termination Tower Structure as per technical specification.This also includes construction of temporary water proof tent shed for Cable Jointing Bay, including arrangement of all the necessary tools and plants, including Air Conditioner, temporary power supply etc. at the termination bay site not limiting to the above and any other requirements for completion of the work as per specification. |
| 20 | Erection of 216 kV Surge arrestor with clamp & connectors on Cable Termination Tower Structure |
| 21 | Installation of miscellaneous materials for Cable laying, Jointing and bonding including link boxes, sheath Voltage limiters, earth continuity cable, earthing material , ground mat, cables makers, warning tapes, and all other materials etc, required as per techanical specifications and as per statutory requirements |
| 22 | Civil Works |
| 23 | Soil Testing including Soil resistivity in complete shape along with submission of report etc. up to the depth of 15.0 Mtrs. |
| 24 | Excavation in all depths for following type of soil and rocks and back filling (back filling shall be done in layers of 500mm sprinkling of water and compaction thereafter and disposed of excess quantity of excavated soil at suitable place after back filling), & if required for filling the foundation, borrowed earth/morrum/sand shall be brought for filling and compaction, including supply of sand, all T&P, labour as required. |
| 25 | Dense/Compact soil |
| 26 | FOUNDATION MATERIALS: Supply of all materials like cement, steel, all coarse aggregates, fine aggregates and making foundations of the required above mentioned type towers as per the direction laid down in the technical specification and the direction of the site- in charge |
| 27 | Design, Engineering, Providing and laying of plain cement concrete (PCC 1:3:6) of grade M10 with approved quality coarse aggregates (Nominal size 12mm to 20mm) , fine aggregates, cement in tower foundation as blind layer inclusive of labour charges for concrete mixing & curing. This includes supply of all labourers, T&P and dewatering wherever required as per Technical specification and instruction of Engineer In charge. |
| 28 | Design, Engineering and laying of reinforced cement concrete (RCC1:1:2) of grade M25 for open cast foundation as per specification and approved drawings with supply of approved quality coarse aggregates(Nominal size 12mm to 20mm), fine aggregates, cement and steel of different size(as per design) with cutting, bending, binding of M.S.Rod (FE-500) including supply of binding wire in tower foundation and inclusive of labour charges for concrete mixing, supply and fixing of form boxes, curing, shoring, shuttering, testing of sample cement concrete cubes as per IS. The height of the coping shall be 350mm above the finished concrete level. The surrounding area shall be clear from materials. Damage of land if any by the contractor shall be repaired before measurement. This includes supply of all labourers, T&P and dewatering wherever required as per Technical specification and instruction of Engineer In charge. |
| 29 | Cutting bending hooking ,fixing and binding in poisition of MS bars for rainforcement of foundation concrete of towers including supply of wire for binding (With supply of steel rod(TATA/RINL/SAIL Make). |
| 30 | PILE FOUNDATION (UNDER-REAM PILE) BORING &CONCRETE WORKS |
| 31 | Boring for under ream cast-in-Situ piling, with Manual Auger method or by using Motor driven Machinery ,including supply of Bentonite required for as per required procedure depending on the length of the bore stabilization bore of required diameter bore holes as per required design length of the bore. |
| 32 | 500MM DIA |
| 33 | Supply of all materials like cement, coarse aggregates (Nominal size 12mm to 20mm), fine aggregates and making Under-reamed pile foundations (after pile boring as per required depth, basing on design) as per requirement, including supply of all equipment with labours,proper curing of the foundations and T&P as per specification in the concrete ratio 1:1:2 (Grade M-25) and disposal of excess earth as per the direction of Engineer In Charge. This includes supply of all labourers, T&P, head loading of all type of Civil materials and dewatering (including Supply of all T&P, Fuel, Lubricant & electricity etc.) as per Technical specification and instruction of Engineer In charge. |
| 34 | Supply of Steel of different size (as per design) with cutting, bending, welding and binding in position of M.S.Rod for reinfocement of foundation concrete of Piles(Under reem Pile) including supply of binding wire With supply of steel rod ( TATA/RINL/SAIL/JINDAL make) and head loading. |
| 35 | PILE RISER,CAPPING,PEDESTAL & TIE-BEAM CONCRETE WORKS |
| 36 | Design, Engineering, Providing and laying of plain cement concrete (PCC 1:3:6) of grade M10 with approved quality coarse aggregates (Nominal size 12mm to 20mm) , fine aggregates, cement in tower foundation as blind layer inclusive of labour charges for concrete mixing, shoring,shuttering & curing. This includes supply of all labourers, T&P wherever required as per Technical specification and instruction of Engineer In charge. |
| 37 | Pile riser (if required),capping, tie beams etc, required for foundation of columns, equipment etc. with approved quality coarse aggregates (Nominal size 12mm to 20mm) , fine aggregates including supply of cement, different gradient for concrete ratio 1:1:2 (Grade M-25.) including concrete mixing,shoring,shuttering soils and back filling etc and disposal of excess earth as per the direction of Engineer In charge.This includes supply of all labourers, T&P, head loading of all type of Civil materials and dewatering (including Supply of all T&P, Fuel, Lubricant & electricity etc.) as per Technical specification and instruction of Engineer In charge. |
| 38 | Supply of Steel of different size (as per design ) with cutting, bending, welding,binding in position of M.S.Rod for reinfocement of foundation concrete of Pile Risers including supply of binding wire With supply of steel rod ( TATA/RINL/SAIL/JINDAL make only) and head loading. No other make steel shall be accepted. |
| 39 | Excavation in any type of soil or rocks and back filling and disposal of excess quantity of excavated soil at suitable place after back filling, & if required for filling the foundation, borrowed earth/morrum/sand shall be brought for filling and compaction, including supply of sand, all T&P, labour as required. |
| 40 | Supply and putting of MS liner including all asociated works Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender