Science and Technology Statutory Bodies & Commissions/Committees Closing in 7 days TDR #56296193

Tender For Contruction Of Temporary Shed For Welding Cabins At Istc Workshop Building, Csio Chandigarh.

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
16.97 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
7 days left
EMD
33957
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Contruction Of Temporary Shed For Welding Cabins At Istc Workshop Building, Csio Chandigarh.

BOQ

Name of Work:- Contruction of temporary shed for welding cabins at ISTC Workshop Building, CSIO Chandigarh.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within CSIO. All kinds of soil
2Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas,lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
6Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete Foundations, footings, bases of columns, etc. for mass concrete
7Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers Lintels, beams, plinth beams, girders, bressumers and cantilevers
8Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts Columns, Pillars, Piers, Abutments, Posts and Struts
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 12 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4(1 cement : 4 coarse sand)
11Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete - Sandhu/ Grace and Dorma or equivalent make .
12Providing and fixing powder coated aluminium sliding door bolts, with nuts and screws etc. complete 250x16 mm - Make classic or equivalent.
13Providing and fixing powder coated aluminium tower bolts, dyed to required colour or shade, with necessary screws etc. complete :200x10 mm- Make classic or equivalent.
14Providing and fixing powder coated aluminium tower bolts, dyed to required colour or shade, with necessary screws etc. complete150x10 mm - Make classic or equivalent.
15Providing and fixing powder coated alumnium handles,dyed to required colour otr shade, with necessary screws etc. complete: 100mm - Make classic or equivalent.
16Providing and fixing powder coated alumnium hanging floor door stopper,powder coated required colour otr shade, with necessary screws etc. twin rubber stopper - Make classic or equivalent.
17Providing and fixing powder coated alumnium casement stays, powder coated required colour otr shade, with necessary screws etc - Make classic or equivalent.
18Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, tube section including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete - Tata or sale or equivalent make.
19Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. double charge Size of tile 600x600 mm - Kajaria or equivalent make.
20Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. double charge Size 600x600mm - Kajaria or equivalent make.
21Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required - Tata, jindal or equivalent make.
2212 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
2315 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)
2420 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
25Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre - Make asian paint/dulux/nerolac or equalent make .
26Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. Make Asian paint/ Dulux/Nerolac or equivalent make.
27Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface per bag to prepare the surface even and smooth complete. J.K Wall Putty / Birla White Putty/Asian Paint Wall Putty or equivalent make .
28Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour : Old work (one or more coats) - Make asian paint/ Dulux/Nerolac or equalent make .
29Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
30Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content : With water thinnable cement primer on wall surface havingVOC content less than 50 grams/litre - Make Asian paint/dulux/nerolac or equivalent make . .
31Demolishing cement concrete manually/ by mechanical means including disposal of material within(CSIO)as per direction of Engineer - in - charge: Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
32Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within(CSIO) as per direction of Engineer-in-charge : In cement mortar
33Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
34Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
35Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimumthickness of powder coating 50 micron)
36Providing and fixing (average) 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides Nova ply/ Action tesa or equalent make
37Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not lessthan 12.50 kg/sqm) - Saint gobain or equivalent
38Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width
39Providing and fixing mineral fibre false ceiling tiles at all heights of 595X595 mm of approved texture, design and pattern. The tiles shouldhave Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60) - Armstrong or equivalent make.
40Providing & fixing vertical blinds of louvers fabric woven of approved shades.The head rail should be powder coated aluminium alloy section with tilt gear hub delrinacetal louer carriers including any other fixtures to make the blind oprational and fixing in position all complete of Make - Vista Levelor or equivalent as approved by Engineer in charge before fixing..
41Carrying out petty job of welding works with necessary tools welding set & rods etc for petty works at different location which can not be measured as per direction of engineer -in-charge .
42Electrical Disconnection and Dismantling of some old electrical acessories like MCBs, cabling size upto 35 sqmm, and shifting of material from site to store. Make provision for fixing of four Pole MCB in existing electrical panel as directed by Engineer-In-Charge.Note:- Before Quoting the rates, please visit the site foe assessment of the work.
43Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (i) Group-C(Note- Moduler box used for switches should have 25% extra space as required)
44Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
45Wiring for circuit/ submain wiring alongwith earth wire with the 2X2.5 sq mm + 1X2.5 sq mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note- Minimum size of 25mm medium class PVC conduit must be used )
46Wiring for circuit/ submain wiring alongwith earth wire with the 2X4 sq mm + 1X4 sq mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note-Minimum size of 25mm medium class PVC conduit must be used)
47Supplying and fixing 3 Module (100mmX75mm) modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
48Supplying and fixing 6 Module (200mmX75mm) modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
49Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
50Supplying and fixing 5/6 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Note: Suitable for fixing on PVC modular box for PVC trunking)
51Supplying and fixing 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
52Supplying and fixing modular 3 pin 5/6 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Note: Suitable for fixing on PVC modular box for PVC trunking)
53Supplying and fixing modular 6 pin 15/16 A socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
54Supplying and fixing of phenolic laminated sheet of 3 mm thick , ISI marked with cutting etc. anyone of make Heylem/Super Heylem.
55LED Panel light 2x2 ft. (System lumen efficacy ≥105<120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 36 watt
56LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) . 18-22 watt
57Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
58Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
59Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TPN MCB complete with connections, testing and commissioning etc. as required.
60Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
61Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
62Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
63Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
64Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
65Supply, Installation, Testing and Commissioning of 600 mm sweep,3 Blade , metallic Body wall fan , Air delivery minimum 250CMM, 1440 RPM, including all accessories , low noise level, suitable for 230 V, 50 Hz, single phase AC Supply, complete as required.
66Supply of Metallic Body Exhaust Fan of size 300 mm sweep, with G.I. sheet louver shutter, Grey in color, RPM: 900-950, four number blades, Air delivery (minimum) 1145 m3/h, low noise level, suitable for 230V, 50 Hz, single phase AC Supply, complete as required.
67Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450mm sweep
68Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
69Making the opening of suitable size in the Brick wall/window for installation of Exhaust Fan of Size 450mm sweep, including making good the damage, complete as required at site.
70Supplying and fixing of 25mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
71Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
72Supply and testing of aluminium conductor XLPE. insulated PVC sheathed armoured Cable conforming to IS 7098 Part- 1 ammended upto date complete as per equirement at the site of work upto entire satisfaction of the Eingeer-in- charge. Size: 4 Core x 10 Sqmm XLPE cable
73Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 10 sq. mm (25mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
74Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
75Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm in the existing masonry open duct as required.
76Supplying and fixing of u-PVC adaptable trunking system of size 100mm X 50mm complete with trunking cover,end cap etc. for housing the electrical modular box for fixing modular switch sockets, telephone socket etc, on the wall/tables/pillars etc. as required.
77Supply and fixing of PVC 6 module conversation frame for CMS trunking with cover plate and blanking plate suitable for fixing in 100mmx50mm DLP U-PVC trunking for fixing the modular switch and socket 5amp./15amp. Complete as required at site.
78Supply and fixing of RJ45 CAT6 Computer Jack with PVC modular box/conversation frame, base and cover plate suitable for fixing in 100mm x 50mm U-PVC trunking complete as required at site. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56296193
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 16.97 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Contruction Of Temporary Shed For Welding Cabins At Istc Workshop Building, Csio Chandigarh.
Basic Detail
Tender No CSIO/1580/25-26/ESD
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 03 Jul 2026
Submission Date 13 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 16.97 Lakhs
Tender Fee Ref. Documents
EMD 33957
Exemption Not Available
Document List
3d1a99b4-aed7-4001-ba1e-b293eac001f0.html
BOQ_329961.xls
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

3d1a99b4-aed7-4001-ba1e-b293eac001f0.html

xls

BOQ_329961.xls

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders