Tender For Renovation Of Electrical Installation Work Including Laying Of Incoming Power Cable At Pwd Tent.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Jul 2026
4 days left
EMD
14649
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Electrical Installation Work Including Laying Of Incoming Power Cable At Pwd Tent.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S&F 3nos. DIN type HRC fuse as per rating. Make-L&T. |
| 2 | Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting. |
| 3 | 200/250A |
| 4 | Supply and drawing incl. necy. connection of multistranded single core copper cable/wire leads with necessary conections incl screws/ washers/ saddles etc. (Make: Polycab/Gloster/RR Kabel) |
| 5 | 4X70 sqmm + 2X16 sqmm |
| 6 | Finishing of the PVC insulated wire/cable ends by socketting with ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 7 | 4X70 sqmm + 2X16 sqmm |
| 8 | Supply & Delivery of 4C x 95Sqmm. 1.1KV.Gr. Al. Ar. PVC./ XLPE. High tensile galvanized steel wire/strip armour for mechanical protection and PVC/ FRPVC outer sheathing Power Cable ( Make- Polycab/Gloster/ RR Kabel) |
| 9 | Laying of one No. 4core 95sqmm cable through micro tunneling with 80 mm OD HD PVC ( 5 mm Thick ) pipe at suitable depth (3 meter below the ground ) and laying the cable through the pipe by cutting entry prockets at both ends a depth of 1 mtr and 0.3 mtr width and making masonary pit at both ends by brick, sand , cement etc incl. top cover as required as per direction of EIC. |
| 10 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. |
| 11 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moistureproof entry of XLPE/PVC armoured cables as below : |
| 12 | 4core 95 sqmm |
| 13 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. |
| 14 | 4core 95 sqmm |
| 15 | Disconnection form bus bar and Dismantling the existing old 250A SDF/ Main Switch from feeder pillar and deposit the same to sectional store. |
| 16 | Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. Make- L&T |
| 17 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) -4 bars 415 V, 315 A,Dimension of Cu. bars[300mm long] 4 x 40x5mm Dimension of Sheet Metal Box 500x150mm |
| 18 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil. |
| 19 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe |
| 20 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 21 | Digging out of soil and dismantling the existing muffing of 02 nos. feeder pillar box to facilitate the entry of 4core 95sqmm armoured cable and mending good the damages after completion of cable connection work. |
| 22 | The defect liability period of the work will be treated as Five years from the date of completion of work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender