Tender For Iei Work In Proposed Cafeteria Lighting, Covered Corridor, Drop Out Point At Hanuman Mandir Complex, Bks Marg, New Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Jul 2026
0 days left
EMD
34330
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Iei Work In Proposed Cafeteria Lighting, Covered Corridor, Drop Out Point At Hanuman Mandir Complex, Bks Marg, New Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group - C, (Light point-64,fanpoint-38,Exhaust fan point-2) |
| 2 | Wiring for light / power plug with 2X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copperconductor single core cable for loop earthing as required. |
| 3 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. make- BAJAJ/ORIENT/CROMPTON/ HAVELLS, (a)1200mm, service value ≥ 6.0CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 4 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall beignored) |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessedsteel conduit as required.(a)4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 6 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessedmedium class PVC conduit as required.(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 7 | (b)2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 8 | (c)2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). (Note - The DB shall include proper ferruling for all incoming and outgoing wires, including MCB numbering using printed PVC ferrules, DB number marking on the front door, and circuit schedule sheet pasted inside the DB with corresponding MCB circuit details. All wires shall be tagged appropriately with ferrule numbers matching the circuit designation for easy identification and maintenance. Neutral and earth link bars shall be clearly differentiated using colored ferrules e.g., black for neutral, green for earth for each connected wire to ensure easy identification and compliance with standards.) Note: i) Surface or flush mounted DB's shall be provided with suitable size frame work and neatly grouted on to wall and DB shall be fixed on to the frame work using bolts & nuts and other fixing accessories.ii) DB's concealed in wall shall include cut of necessarycivil works and other fixing accessories. iii) The DB's shall be horizontal / vertical type as per configuration of incoming/outgoing feeders. iv) The DB's shall be factory made of approved make and necessary available higher size configured DB's shall be used using approved makes such as Havells, Schneider, Legrand or L&T. (v)The DB shall be minimum IP-42 protection indoor type and conforming to IS/IEC 61439-3. 12 way , Double door |
| 10 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (a) 12 way (4 + 36), Double door |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole, makes such as Havells, Schneider, Legrand OR L&T |
| 12 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.makes such as Havells, Schneider, Legrand (a) 63 Amps |
| 13 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 A |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Make:- Schneider Electric/ Legrand /Anchor /Havells(a) 5/6 A switch |
| 15 | (b) 3 pin 5/6 A socket outlet |
| 16 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 17 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. asrequired. |
| 18 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 19 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required |
| 20 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm),18-22 Watt. Make:- Philips / Havells / Bajaj / Crompton |
| 21 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) (a) 22 watt |
| 22 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium .Make:- Philips / Havells / Bajaj / Crompton (a) 12 -15 watt |
| 23 | Supply, installation, testing, and commissioning of a heavy-duty exhaust fan suitable for continuous ventilation (size as mentioned below). The fan shall operate on 230V AC, 50 Hz, equipped with a copper-wound motor having thermal overload protection and sealed ball bearings for long life. The fan shall deliver a minimum air delivery of 900–1350 m³/hr with low noise operation. The body and front guard shall be made of powder-coated metal or high-strength ABS polymer depending on the model, with three aerodynamically balanced blades ensuring smooth, vibration-free running. The exhaust fan shall also include a factory-fitted louvers/shutter mechanism for preventing reverse airflow, insects, and dust ingress. Installation includes fixing of fan frame using anchor fasteners, providing necessary supports, and sealing gaps around the fan with cement mortar/PU sealant for dust-free installation. The exhaust fan s should have IS 2312 and minimum IPX4 protection or better suitable for ventilation application. Thefan shall be of approved make such as Crompton / Havells / Usha /Orient / Bajaj or equivalent, complete with all accessories with 02years warranty. (a) 450 mm (18 inch) |
| 24 | SITC of Yellow COB LED Strip complete with high-density Chip-on-Board LEDs, operating on 12V/24V DC supply, having uniform dot-free illumination, suitable wattage, lumen output, CRI ≥80, and color temperature as per approved specifications and drawings. The LED strip shall be supplied with compatible driver/power supply, connectors, mounting accessories, and all necessary hardware required for proper installation and commissioning. The strip shall have minimum IP20 for indoor use or IP65/IP67 for damp/outdoor locations as specified, ensuring protection against dust and moisture ingress. The work shall include testing, commissioning, and compliance with relevant IEC/BIS standards.MAKE- philips /wipro / havells |
| 25 | Supplying and laying of DWC HDPE Pipe of size 38/50 mm ISI marked along with all accessories like socket, bend , couplers etc confirming to IS 14930 complete with fitting and cutting, jointing etc direct in ground complete asrequired at site |
| 26 | Cutting of existing marble flooring in required alignment for laying of DWC (Double Wall Corrugated) pipe of size 38 mm / 50 mm dia/Heavy Duty PVC Pipe of size 25mm, including marking, cutting with suitable mechanical cutter without damaging adjacent flooring / tiles, and removal of malba etc, complete as required. The cutting shall be carried out to a uniform width of 75 mm and depth of 75 mm to accommodate the pipe along with necessary bedding. The scope shall include proper positioning of DWC pipe, followed by refilling of the trench with cement mortar (as required) in layers, properly compacted to ensure stability and protection of the pipe. The top surface shall be finished with the surrounding floor using appropriate mortar, making it ready for final floor restoration. The item includes all labour, tools, tackles, cutting equipment, disposal of debris within site premises, and all incidental works required for proper execution, complete asdirected by the Engineer-in-Charge. |
| 27 | Supplying and laying of Heavy Duty /C-Class PVC Pipe of size 25mm ISI marked along with all accessories like socket , bend , couplers etc. confirming to IS 14930 complete with Fitting and cutting, jointing etc. direct in ground / concealed complete as required as per site requirements. Make : Finolex, AKG, BEC |
| 28 | SITC of heavy-duty pole mounted fan for corridor, having 900 mm (36 inch) sweep size, suitable for operation on 230V AC, 50 Hz, single-phase supply, complete with copper- wound TEFC motor, dynamically balanced aluminium/steel blades, safety guard and heavy-duty mounting arrangement. The fan shall have a speed of 700–850 RPM, Class-F insulation, double ball bearings, thermal Overload protection and minimum IP55 protection for motor and electrical components. The work shall include installation on pole/support with all necessary accessories such as MS clamps, brackets, nuts, bolts, washers, anchor fasteners, saddles and mounting hardware, complete with proper electrical termination, interconnections, earthing, testing and commissioning for satisfactory operation. Make : - Phillips/ Usha /orient/ Havells/Bajaj Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayJul 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender